Finding | |
|---|---|
| Title | Failure to Meet TS Oversight Requirement |
| Description | A Green self-revealing NCV of Technical Specification (TS) 5.1, responsibility, was identified because on February 9, 2010, the control room supervisor (CRS) assigned as having the control room command function, left the control room without designating another senior reactor operator (SRO) qualified individual to assume the control room command function. The CRS promptly returned to the control room shortly after the issue was identified. This issue was entered into Entergy\'s CAP as CR-IP2-201 0-00708. he finding is more than minor because it could be reasonably viewed as a precursor to a significant event. Specifically, the absence of SRO oversight during licensed control room activities increases the likelihood of human performance errors contributing to an initiating event and reduces the effectiveness of event mitigation. The finding is associated with the human performance attribute of the Mitigating Systems cornerstone and affects the cornerstone objective of ensuring the availability, reliability and capability of systems that respond to initiating events to prevent undesirable consequences. The finding was not suitable for quantitative assessment using existing Significance Determination Process guidance. Using IMC 0609, Appendix M, Significance Determination Process Using Qualitative Criteria, NRC management determined the finding to be of very low safety significance (Green) because of the short period the CRS was absent from the control room, and because no initiating events occurred during that time. The finding has a cross-cutting aspect in the area of human performance associated with the work practices attribute because of the ineffective use of shift turnover practices, in that the CRS did not self check or communicate his decision to leave the control room to the rest of the control room staff. |
| Site: | Indian Point |
|---|---|
| Report | IR 05000247/2010005 Section 4OA5 |
| Date counted | Dec 31, 2010 (2010Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | |
| Inspectors (proximate) | T Burns T Hedigan D Caron D Jones J Noggle M Gray M Halter P Cataldo P Prescott R Latta S Barr |
| CCA | H.12, Avoid Complacency |
| INPO aspect | QA.4 |
| ' | |
Finding - Indian Point - IR 05000247/2010005 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Indian Point) @ 2010Q4
Self-Identified List (Indian Point)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||