| 05000220/LER-1976-001, :on 760117,RV-30 a & B Core Spray Delta P Instrumentation Indicated Out of Normal Range.Caused by Setpoint Drift in Conservative Direction |
- on 760117,RV-30 a & B Core Spray Delta P Instrumentation Indicated Out of Normal Range.Caused by Setpoint Drift in Conservative Direction
| |
| 05000220/LER-1976-002, :on 760204,MAPHLGR Kw/Ft Vs Exposure Curve Points Discovered in Error by No More than 0.1 Kw/Ft Nominal Maphlgr Limit 8.52 Kw/Ft.Caused by Interpolation of Tech Specs W/O Grid or Breakpoints |
- on 760204,MAPHLGR Kw/Ft Vs Exposure Curve Points Discovered in Error by No More than 0.1 Kw/Ft Nominal Maphlgr Limit 8.52 Kw/Ft.Caused by Interpolation of Tech Specs W/O Grid or Breakpoints
| |
| 05000220/LER-1976-003, :on 760207,high Drywell Pressure Indicator Tripped Low.Caused by Setpoint Drift |
- on 760207,high Drywell Pressure Indicator Tripped Low.Caused by Setpoint Drift
| |
| 05000220/LER-1976-004, :on 760207,reactor lo-lo-lo Level Indicator Actuated High.Caused by Setpoint Drift |
- on 760207,reactor lo-lo-lo Level Indicator Actuated High.Caused by Setpoint Drift
| |
| 05000220/LER-1976-005, :on 760210,refuel Platform High Range Monitor Calibr Indicated Response of 350 M/R Rather than 800 M/R. Caused by Failed Detector.Detector Replaced |
- on 760210,refuel Platform High Range Monitor Calibr Indicated Response of 350 M/R Rather than 800 M/R. Caused by Failed Detector.Detector Replaced
| |
| 05000220/LER-1976-006, :on 760215,loss of HPCI Component Occurred Due to Apparent Failure of Pump Suction Pressure Switch.Caused by Disconnected Linkage Arm on Mercoid.Arm Reconnected |
- on 760215,loss of HPCI Component Occurred Due to Apparent Failure of Pump Suction Pressure Switch.Caused by Disconnected Linkage Arm on Mercoid.Arm Reconnected
| |
| 05000220/LER-1976-014, :on 760420,fish Impingement on Traveling Screens Found in Excess of ETS Limits of 20,000/24 H.Caused by Annual Migration |
- on 760420,fish Impingement on Traveling Screens Found in Excess of ETS Limits of 20,000/24 H.Caused by Annual Migration
| |
| 05000220/LER-1976-015, :on 760424,fish Impingement Found Increasing. Caused by Annual Migration |
- on 760424,fish Impingement Found Increasing. Caused by Annual Migration
| |
| 05000220/LER-1976-016, :on 760427,fish Impingement on Traveling Screens Found in Excess of ETS Limits of 20,000 Per 24 H.Caused by Annual Migration |
- on 760427,fish Impingement on Traveling Screens Found in Excess of ETS Limits of 20,000 Per 24 H.Caused by Annual Migration
| |
| 05000220/LER-1976-017, :on 760428,fish Impingement Upon Traveling Screens Found in Excess of ETS Limits of 20,000 Per 24 H.Caused by Annual Migration |
- on 760428,fish Impingement Upon Traveling Screens Found in Excess of ETS Limits of 20,000 Per 24 H.Caused by Annual Migration
| |
| 05000220/LER-1976-017-01, :on 760428,fish Impingement on Traveling Screens Found in Excess of ETS Limits of 20,000 Per 24 H.Caused by Annual Migration |
- on 760428,fish Impingement on Traveling Screens Found in Excess of ETS Limits of 20,000 Per 24 H.Caused by Annual Migration
| |
| 05000220/LER-1976-018, :on 760508,fish Impingement on Traveling Screens Determined to Be in Excess of 20,000 Per 24 H.Cause Unknown. Influx of Alewives & Rainbow Smelt Occurs Annually |
- on 760508,fish Impingement on Traveling Screens Determined to Be in Excess of 20,000 Per 24 H.Cause Unknown. Influx of Alewives & Rainbow Smelt Occurs Annually
| |
| 05000220/LER-1976-019, :on 760423,turbine Anticipatory Trip Bypass Reactor Scram Switch Actuated Higher than Required Psig During Surveillance Testing.Caused by Setpoint Drift.Switch Recalibr & Returned to Svc |
- on 760423,turbine Anticipatory Trip Bypass Reactor Scram Switch Actuated Higher than Required Psig During Surveillance Testing.Caused by Setpoint Drift.Switch Recalibr & Returned to Svc
| |
| 05000220/LER-1976-020, :on 760423,switch 1B05C,indicating Emergency Cooling High Flow & Isolating Sys,Actuated Higher than Required 19 Psid.Caused by Setpoint Drift |
- on 760423,switch 1B05C,indicating Emergency Cooling High Flow & Isolating Sys,Actuated Higher than Required 19 Psid.Caused by Setpoint Drift
| |
| 05000220/LER-1976-021, :on 760515,shutdown Cooling Sys dc-operated Instrumentation Valve 38-02 Failed to Function.Caused by Open in in Motor Windings.Motor Rewound |
- on 760515,shutdown Cooling Sys dc-operated Instrumentation Valve 38-02 Failed to Function.Caused by Open in in Motor Windings.Motor Rewound
| |
| 05000220/LER-1976-022, :on 760527,review Revealed That Fish Impinged Exceeded ETS Limits During Routine Sampling on 760519-27. Cause Not Related to Station Operation.Species of Fish Involved Migrate Inshore in Spring |
- on 760527,review Revealed That Fish Impinged Exceeded ETS Limits During Routine Sampling on 760519-27. Cause Not Related to Station Operation.Species of Fish Involved Migrate Inshore in Spring
| |
| 05000220/LER-1976-023, :on 760625,smoke Observed from Relay 4-112 B/40. Caused by Apparently Shorted Coil,Resulting in Blown Fuse. Relay Replaced |
- on 760625,smoke Observed from Relay 4-112 B/40. Caused by Apparently Shorted Coil,Resulting in Blown Fuse. Relay Replaced
| |
| 05000220/LER-1976-024, :on 760613,average Power Range Monitors 17 & 18 Failed to Produce Scram Signal at Required Flow Bias Setpoint.Caused by Setpoint Drift.Instrument Recalibr to Required Specs |
- on 760613,average Power Range Monitors 17 & 18 Failed to Produce Scram Signal at Required Flow Bias Setpoint.Caused by Setpoint Drift.Instrument Recalibr to Required Specs
| |
| 05000220/LER-1976-025, :on 760627,average Power Range Monitors 11 & 15 Failed to Produce Scram Signal at Required Flow Bias Setpoint.Caused by Setpoint Drift.Instruments Calibr to Required Specs |
- on 760627,average Power Range Monitors 11 & 15 Failed to Produce Scram Signal at Required Flow Bias Setpoint.Caused by Setpoint Drift.Instruments Calibr to Required Specs
| |
| 05000220/LER-1976-029, :on 760805,milk Sample Not Analyzed for I-131 within 8 Days of Collection.Caused by Mail Backlog Due to Holiday Weekend |
- on 760805,milk Sample Not Analyzed for I-131 within 8 Days of Collection.Caused by Mail Backlog Due to Holiday Weekend
| |
| 05000220/LER-1976-030, :on 760805,review Revealed That Condenser Delta Temp & Discharge Canal Temp Not Recorded Hourly During 760717-22.Caused by Computer Typers Being Down Due to New Instrumentation Installation.Data Through 760731 Invalid |
- on 760805,review Revealed That Condenser Delta Temp & Discharge Canal Temp Not Recorded Hourly During 760717-22.Caused by Computer Typers Being Down Due to New Instrumentation Installation.Data Through 760731 Invalid
| |
| 05000220/LER-1976-031, :on 760809,feedwater Pump 11 Failed to Start When Manually Initiated.Cause by Agastat Time Delay Model 2462 PD Failure |
- on 760809,feedwater Pump 11 Failed to Start When Manually Initiated.Cause by Agastat Time Delay Model 2462 PD Failure
| |
| 05000220/LER-1976-032, :on 760827,RE-22A Tripped Higher than Required Psig Value During Surveillance Testing of Main Steam Line Break Instrumentation.Caused by Setpoint drift.RE-22A Recalibr |
- on 760827,RE-22A Tripped Higher than Required Psig Value During Surveillance Testing of Main Steam Line Break Instrumentation.Caused by Setpoint drift.RE-22A Recalibr
| |
| 05000220/LER-1976-033, :on 760908,Tech Spec Required Surveillance on Vacuum Breaker Exercising Following Relief Valve Discharge to Torus Not Performed Following Scrams on 760806 & 23. Caused by Not Posting Requirements on Checkoff Sheets |
- on 760908,Tech Spec Required Surveillance on Vacuum Breaker Exercising Following Relief Valve Discharge to Torus Not Performed Following Scrams on 760806 & 23. Caused by Not Posting Requirements on Checkoff Sheets
| |
| 05000220/LER-1976-034, :on 761012,milk Samples Collected on 760920 Not Counted Until 760928-30.Caused by Delay in Shipping.W/ |
- on 761012,milk Samples Collected on 760920 Not Counted Until 760928-30.Caused by Delay in Shipping.W/
| |
| 05000220/LER-1976-035, :on 761012,benthos Bimonthly Collection for Aug 1976 Not Performed Unitl 760904.Caused by Recent OSHA Regulations Imposed on Prof Divers |
- on 761012,benthos Bimonthly Collection for Aug 1976 Not Performed Unitl 760904.Caused by Recent OSHA Regulations Imposed on Prof Divers
| |
| 05000220/LER-1976-036, :on 761015,lo-lo-lo Reactor Water Level Switch RE-18A Failed to Provide Trip at Indicated Inches.Caused by Apparent Setpoint Drift.Switch Inspected & Recalibr.W/ |
- on 761015,lo-lo-lo Reactor Water Level Switch RE-18A Failed to Provide Trip at Indicated Inches.Caused by Apparent Setpoint Drift.Switch Inspected & Recalibr.W/
| |
| 05000220/LER-1976-037, :on 761019,monthly Chemical Proportional Composite for Jul 1976 Inadvertently Discarded Prior to Analyzing Chemical Liquid Waste.Caused by Lack of Prompt Labeling. Procedures Reviewed |
- on 761019,monthly Chemical Proportional Composite for Jul 1976 Inadvertently Discarded Prior to Analyzing Chemical Liquid Waste.Caused by Lack of Prompt Labeling. Procedures Reviewed
| |
| 05000220/LER-1976-039, :on 761116,I-131 Concentration in 761101 Milk Sample Found in Excess of 19 Pci Per Liter.Caused by Chinese Weapon Testing Prior to Sampling |
- on 761116,I-131 Concentration in 761101 Milk Sample Found in Excess of 19 Pci Per Liter.Caused by Chinese Weapon Testing Prior to Sampling
| |
| 05000220/LER-1976-040, :on 761210,lo-lo-lo Reactor Water Level Sensors RE-18A,B & C Did Not Actuate within Required Tolerance Setpoint Band.Caused by Apparent Setpoint Drift |
- on 761210,lo-lo-lo Reactor Water Level Sensors RE-18A,B & C Did Not Actuate within Required Tolerance Setpoint Band.Caused by Apparent Setpoint Drift
| |
| 05000220/LER-1976-041, :on 761210,sensors Actuated Sooner than Required Setpoint During Routine Surveillance Testing on High Drywell Pressure.Caused by Apparent Setpoint Drift |
- on 761210,sensors Actuated Sooner than Required Setpoint During Routine Surveillance Testing on High Drywell Pressure.Caused by Apparent Setpoint Drift
| |
| 05000220/LER-1976-042, :on 761222,reactor Bldg Integrity Disrupted. Caused by Two Doors Being Opened Simultaneously in Reactor Bldg Extension Air Lock.Standing Order Nmpso 12 Issued, Specifying Door Opening Control Procedures |
- on 761222,reactor Bldg Integrity Disrupted. Caused by Two Doors Being Opened Simultaneously in Reactor Bldg Extension Air Lock.Standing Order Nmpso 12 Issued, Specifying Door Opening Control Procedures
| |
| 05000220/LER-1976-043, :on 761025,feedwater Pump 12 Taken Out of Svc. Caused by Repairs Made to Sealwater Strainer & Small Gear Box Leads W/Unit on Load |
- on 761025,feedwater Pump 12 Taken Out of Svc. Caused by Repairs Made to Sealwater Strainer & Small Gear Box Leads W/Unit on Load
| |
| 05000220/LER-1976-044, :on 761116,one Emergency Vent Loop Taken Out of Svc.Caused by Repairs Being Made on Bent Observation Door While Unit on Load |
- on 761116,one Emergency Vent Loop Taken Out of Svc.Caused by Repairs Being Made on Bent Observation Door While Unit on Load
| |
| 05000220/LER-1976-045, :on 761231,sodium Valve for Liquid Effluents Found Above Limits.Caused by Pump Rate Exceeding Allowable Concentration in Makeup Demineralizer Waste Tank. Surveillance Procedure Revised |
- on 761231,sodium Valve for Liquid Effluents Found Above Limits.Caused by Pump Rate Exceeding Allowable Concentration in Makeup Demineralizer Waste Tank. Surveillance Procedure Revised
| |