Finding | |
---|---|
Title | Failure to Identify a CAQ for Power Shield Catalog #609903-T501N |
Description | The NRC identified an NCV of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Actions, for the licensees failure to identify that a deviation in equipment qualification of power shield relays in 480V switchgear XSW-1DB1 was a condition adverse to quality in their CAP. Specifically, the licensee failed to identify that Power Shield catalog #609903-T501N in purchase order NU-02SR750589 was not qualified to meet its original total integrated dose limit of 100,000 rads as stated in the Asea Brown Boveri 10 CFR Part 21 notification letter. The licensee entered this issue into their CAP as CR-17-05391 and performed an evaluation to determine there was reasonable assurance that the power shield relay in purchase order NU-02SR750589 could perform its intended safety function. The performance deficiency was determined to be more than minor because it was associated with the design control attribute of the mitigating systems cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the failure to identify that Power Shield catalog #609903-T501N in purchase order NU-02SR750589 was not qualified to the 1,350 rad TID specified in the equipment qualification database for zone AB-72 resulted in a reasonable doubt that the qualification requirements over the relays service life would be met. The team determined the finding to be of very low safety significance (Green) because the finding affected the design or qualification of a mitigating SSC and the SSC maintained its operability. The team determined that no crosscutting aspect was applicable because the finding did not reflect current licensee performance. |
Site: | Summer |
---|---|
Report | IR 05000395/2017007 Section 1R21 |
Date counted | Dec 31, 2017 (2017Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | M Riley C Franklin N Morgan D Terry-Ward W Sherbin A Della Grecas Walker |
Violation of: | 10 CFR 21, PART 21-REPORTING OF DEFECTS AND NONCOMPLIANCE 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion XVI |