Pages that link to "ML20058K581"
Jump to navigation
Jump to search
The following pages link to ML20058K581:
Displayed 50 items.
- ML20062G257 (← links)
- ML20062G242 (← links)
- ML20062D494 (← links)
- ML20058L228 (← links)
- ML20058L214 (← links)
- ML20058L203 (← links)
- ML20058L122 (← links)
- ML20058L116 (← links)
- ML20058L105 (← links)
- ML20058L079 (← links)
- ML20058L074 (← links)
- ML20058L067 (← links)
- ML20058L059 (← links)
- ML20058L045 (← links)
- ML20058L031 (← links)
- ML20058L029 (← links)
- ML20058K954 (← links)
- ML20058K952 (← links)
- ML20058K745 (← links)
- ML20058K735 (← links)
- ML20058K714 (← links)
- ML20058K707 (← links)
- ML20058K694 (← links)
- ML20058K621 (← links)
- ML20058K595 (← links)
- ML20127P254 (← links)
- ML20127L320 (← links)
- ML20127L289 (← links)
- 05000263/LER-1998-002-02, :on 980415,main Steam Isolation Valve Position Setpoint Outside Allowed Range,Was Found.Caused by Previous Testing Technique & Use of Particular Switch Model.Eight New Position Switches W/Less Deadband Installed (← links)
- 05000263/LER-1986-024, :on 861003,reactor Scram Occurred During Venting of Condensate Pump 11.Caused by Lack of Procedures & Two Pumps Sharing Common Vent Line.Procedure Prepared. Individual Vent Lines Will Be Installed (← links)
- 05000263/LER-1986-026, :on 861014,portions of Group II Primary Containment Isolation Sys & Standby Gas Treatment Sys Started W/O Valid Initiation Signal.Caused by Blown Fuse. Fuse Replaced (← links)
- 05000263/LER-1986-025, :on 861014,during Performance of Scram Discharge Vol Level Instrument Surveillace Test,Reactor Scrammed.Caused by Personnel Error.Improved Lighting Will Be Provided in Work Area (← links)
- 05000263/LER-1986-029, :on 861225,reactor Bldg Ventilation Isolation & Standby Gas Treatment Sys Initiation Occurred During Routine Power Operation.Caused by Spurious hi-hi Trip.Monitor & Reactor Bldg Ventilation Isolation Reset (← links)
- 05000263/LER-1986-028, :on 861219 & 870109,emergency Filtration Train Sys Transferred to Toxic Chemical Mode.Caused by Defective Lamp Holder,Leading to Chlorine Monitor Optics Light Source Failure.Lamp Holder Replaced (← links)
- 05000263/LER-1997-011, :on 970908,failure to Transfer HPCI & RCIC Suctions to Suppression Pool After Making Condensate Storage Tank Level Instrument Inoperable Occurred.Caused by Cognitive Personnel Errors.Procedures Reviewed (← links)
- 05000263/LER-1997-010-01, :on 970916,failure to Include Some Supports on Reactor Head Vent Line in ISI Program in 2nd 10 Year Interval Occurred.Caused by Original Plant Drawings Incomplete.Controlled Drawings Will Be Revised (← links)
- 05000263/LER-1986-021, :on 860620,during Refueling Operations,Reactor Bldg Ventilation Isolations & Standby Gas Treatment Sys Initiations Occurred.Caused by Loss of Sample Flow from Channel a Vent as Result of Failed Flow Sensor (← links)
- 05000263/LER-1986-018, :on 860616,during Refueling,Voltage Transient Experienced,Causing Protective Fuses in All intermediate- Range Monitors on Reactor Protection Sys B to Blow.Caused by Design Flaw.Mods Under Investigation (← links)
- 05000263/LER-1986-019, :on 860617,during Surveillance Testing,Noise Spike on intermediate-range Monitor 16 Tripped Channel a, Resulting in Initiation of Reactor Protection Sys.Caused by Inadvertent Manipulation of Detector Cables (← links)
- 05000263/LER-1986-022, :on 860623,reactor Protection MG Set 11 Tripped Causing Reactor Bldg Isolation,Group II Primary Containment Isolation & Initiation of Standby Gas Treatment Sys.Caused by Personnel Error.Operator Counseled (← links)
- 05000263/LER-1986-014, :on 860515,reactor Protection Sys Trip Occurred.Caused by Noise Spike on Intermediate power- Range Monitor 14 Tripping Channel a of Reactor Protection Sys.Channel a Trip Reset (← links)
- 05000263/LER-1986-012, :on 860508 Five Penetrations of Transversing in-core Probe Sys Omitted from double-gasket Seal Testing Procedure.Procedure Revised.Penetrations Tested & Drawings Reviewed (← links)
- 05000263/LER-1986-011, :on 860509,EFT Sys (Control Room HVAC) Automatically Transferred to Toxic Chemical Mode Due to Hydrogen Chloride Monitor Tape Break.Caused by Small Imperfection on Tape (← links)
- 05000263/LER-1986-010, :on 860508,reactor Bldg Ventilation Isolation & Standby Gas Treatment Sys Initiation Occurred.Caused by Reactor Bldg Vent wide-range Gas Monitor Trip Due to Hardware/Software Problems (← links)
- 05000263/LER-1987-003, :on 870112,fire Door Blocked Open & Unattended for 8 H or More During Routine Maint Activities.Caused by Inadequate Training of Personnel.Water Hose Removed & Fire Door Closed.Addl Fire Door Training Initiated (← links)
- 05000263/LER-1986-007, :on 860224,EFT Sys (Control Room HVAC) Transferred to Toxic Chemical Emergency Mode Due to Chlorine Monitor Tape Break,Resulting in Monitor Trip.Caused by Worn Pinch Roller.Roller Replaced & Head Cleaned (← links)
- 05000263/LER-1987-002, :on 870108,trip of RHR Shutdown Cooling Supply High Pressure Interlock Occurred.Caused by Pressure Transient Which Tripped Interlock Pressure Switches.Return Lines & Shutdown Cooling Supply Flushed (← links)
- 05000263/LER-1985-017, :on 851007,spurious Trip of Chlorine Monitor Occurred.Caused by Cassette Running Out of Tape Due to Insufficient Length Supplied by Mfg.On 851031,tape Broke Due to Defect.Mfg Notified (← links)
- 05000263/LER-1999-007, :on 990610,HPCI Test Return Valve Was Unable to Close Against Max Expected Differential Pressure.Caused by Failure to Accurately Predict Valve Performance.Procedure Revised.With (← links)
- 05000263/LER-1999-006-01, :on 990602,during Quarterly Surveillance Hcpi Was Declared Inoperable.Caused by Drain Pot Alarm.Revised HPCI Surveillance Test Procedure.With (← links)