ML20058K745
| ML20058K745 | |
| Person / Time | |
|---|---|
| Site: | Monticello |
| Issue date: | 01/29/1975 |
| From: | Anthony D, Mayer L NORTHERN STATES POWER CO. |
| To: | Anthony Giambusso NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| LER-LER-750129, NUDOCS 9102130564 | |
| Download: ML20058K745 (2) | |
Text
.
NSID NORTHERN STATES POWER COMPANY M 8 N N E A PO Li m. M 6 N N E SOTA 55401 January J3, 1975 Q:-
^'
Mr. A. Giambusso, Director Division of Reactor Licensing U S Nucicar Regulatory Commission Wasnington, DC 20555 Licensee Event Report to the 1;RC Failure of Refueling interlock Limit Switch
Dear Mr. Giambusso:
Die 1icensee Event Report for this occurrence is reproduced on :he back of this letter.
Yours very truly, i)')[1 /)4
'/'l Al, [/
/
7 M
ra t
//
L 0 Mayer, PE Manager of ::uclear Support Services LOM/MHV/yb cc:
J G Reppler G Charnon Minnesota Pollution Control Agency Attn:
E A Prvnina 1
1
- over -
9102130564 750129 CF ADDCK 05000263 CF
i 2,9*75 LICENSEE EVENT REPORT CONTROL BLOCK }
l l
l l
l l
[PLE'.CE W. INT ALL GEQUIRED CFD;MATmN) 1 6
ocf N5t tVENT UCf NLEf UCINSE NUVfi!L Typ[
TYPE h lM lN lM lI; l P l 1 ;
I0l0l-IOl0l010 01 - 10 10 !
I I, i l l 1 11 l 1 l
}0 l1 l NAVf 25 26 3D 31 32 7 89 14 15 Ssf PDPT Ml PO W AIPOV OATI CATIGONY 7vF4 SDUHCE DOCtil 'AIVffL
( VE f47 D4 7 f lOlilCON'T !n l0 j lLl l0 l5 lo l-l 0 l 2 I 6 l 3 l l0 11 l1 l9 l7 l5 l l 0 l 1l 21 9l 71 5l 7 6 57 56 59 60 61 SE 69 74 75 80 EVENT DESC AIPTION switch did not actuate preventine roq
$ ! Durine Su veillance test, refueline briage lirait 80 h ! block with aridee over core and reacCor mode switch in startup. I;c redundant l
' E go screv j
$ l interlock I;o previous event.
Limit switch adjusted and actuating arm set 7 8E e_
lb l retichtened usine Loc-Tite on threads. (AO 263/75-02) i go 7 89 l
7 89 COMPONE Y Cpypoggy P S1f U CAUSL C00t CODE C OMPONE N T CODI SUP W MANuf ACTuso vopo+.
l Il E l W l C l K l T l E! ill Fl IN l lGl0l6l0l lY l 0
7 89 10 11 12 17 43 44 47 as CAUSE DESCRIPTION Actuating arm set l
switch failed to actuate due to loose actuating am.
$l Limit 80 GE limit switch l
7 8b loosened folloVing reDeated actuations durinc refueling.
screr gg 3I MMC vr '.15n107 Limit suitch ad iusted and set screw retichtened using Loc-Tit 2.
l 7 89 7 89 ut.1 soc os
$7A7c5
% POWf P OTHip STATU5 DISCOVf Av DISCOVE RY DE SC AIPTION F ACuiv j
l0 ! O! 0l l NA l
lB l l
NA gg ca 45 a g.
7 8 9
1c 12 13
'z$f, ?
0 7,m,;
HELLASEC DE Pbf ASL AMouN' Dr A-~
.,5 ne NA l
l I;A j
g3 7 6 b
10 1'
45 PEASONNEL EXPOSURES NovBE A TvFT DI SC A Plot fO! O! d l
N/
BC 7
89 11 13 PERSONNEL INJ UR!E E l
NUMtsF A' CLEEwl<
l Ol O! b l
NA B0
' 8F
'1 OFFSITE CONSEQUENCES J
3!
FA 80 7 89 LOSS OP OAMACE TD F4Ct'W f
T vDi DE SCRiPTION NA 60 7 89 to PUBLICfTY l
NE l IUs 80 7 89 ADDITIONAL FACTDAS l
NA 60
- B9 I
_ 19U}!
80 6e 612-295-5151 Naug; D. D. Antoriy PHONE GPO 899 667