ML20058L079

From kanterella
Jump to navigation Jump to search
Ler.On 750913,while Performing Local Leak Rate Tests,Core Spray Check Valves AO 14-13A & AO 14-13B Found Leaking in Excess of Acceptance Criteria.Caused by Accumulation of Scale on Seating Surfaces.Cleaned Valve Seats
ML20058L079
Person / Time
Site: Monticello 
Issue date: 11/11/1975
From: Iverson O
NORTHERN STATES POWER CO.
To:
Shared Package
ML20058L058 List:
References
LER-LER-751111-04, LER-LER-751111-4, NUDOCS 9105070382
Download: ML20058L079 (1)


Text

?

1 LICENSEE EVENT REPORT CONTROL BLOCK l l

l l l

l l

(PLEASE PRINT ALL REQUIRED INFORMATION) 1 6

M f NSE E L E I NSE i vf NT NAVI LIC E N5t Novtil k T v pf t

  • Pi lM N lM ! Nl Pl1 l l 0 l 0l-l0 l 0 l 0l 0l 0l-l 0l 0l l4 l 1 l1 l 1l 1l l0l1l 7 E9 14 15 25 PE 30 31 32 Tyk s"$Mt CA't G?n*

DUt.i? NevH n a6 INT Lair ofPom tan

[ CON'T lP l 0 l W

lL l l 0l 5l 0l-l 0 l 2l 6l 3l l 0 } 9l 1l 3l 7 l 5 l l1 l1 l lj 1l 7l 5l 7 6 57 56 59 60 61 68 69 74 75 80 EVENT DESC AiPliCN

@ lkhile perfoming local leak rate tests both core spray check valves A014-13A l

7 89 g3 IEE land A014-13L we re found leaking in excess of the acceptance criteria.

The re-l 7 89 gg Q ldundant isolation valves were operable.

Similar previous events.

Cleaned valve j

7 89 go 0

l seats.(A0 263/75-17-4) l 7 89 gg l

7 09 80 men s v 5'i v CAaSE covew e couw *et e

_ s "C DE cori CDuPCNi v CODI sop 5't o M A'u cis e n vme'c l S l p l [_E,j l VIA l1 ! V l El X]

lKl lR l3 l4 l 0 l W

0 7 89 10 11 12 17 43 44 47 40 CAUSE DESCAIPTION RE l Failed leak test due to accumulation of scale on seating surfaces.

8" tilting disc!

7 89 80

@ l check valve, Rockwell Mfg. Co. Fig 770 (CF8M) 2 M Y. Cleaned valve seats and re-l 7 89 80 3 l tested satisfactory.

l 7 89 80 saa +,

vt uco or S'L'i f

% PDAfA c'ai; $'4 wh C$CC i( Av UISCO+fLV Dl 5 ' ki ON 1 11 d

l0l0l0l lNA l [

l NA l

7 8 9

iD 12 13 44 45 46 60 s;pv er ACT v T' COVIN' DEc!AL!:

D& Pfif 4LE AMDe*.' Cr Ac t.

's LOCAt 'N c5 kt, g tsg d

[Z_j l NA l

l KA l

1 7 8 9

10 11 44 45 80 PERSONNEL ExPOSUPES NavM c DE S;8ac T CN O! O! Q y' PE [A l

1 7 b9 11 12 i3 8;

PERSONNEL INJUAiES N; vet o or s;mioN 1

l 0l0 l 0 l lNA l

7 89 11 12 eo OrrS,TE CONSEOUENCES l NA l

1 5 7 89 BD LCSS DA DAM AGE TO F ACruT V t

  • Pr of f.;wTc N 1 F3 b l SA l

7 89 10 eg PUBUC;T Y

$ l NA l

7 e9 en 91050703B2 751111

~

ado m.At FACiCas CF ADOCK 05000263

] l NA C

I 7 69 go 9[

I w

7 89 eg 0*

I' rs ~

G2 295-5152

'E pm

&PC get.gg7