ML20058K707
| ML20058K707 | |
| Person / Time | |
|---|---|
| Site: | Monticello |
| Issue date: | 02/27/1975 |
| From: | Day B, Mayer L NORTHERN STATES POWER CO. |
| To: | Anthony Giambusso NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| LER-LER-750227, NUDOCS 9102130524 | |
| Download: ML20058K707 (2) | |
Text
CONTROL BLOCX:[ l l
l l
l l
[CLEA".E PRINT ALL EE!UIRED INFORMSTION) 1 6
i NAME LCENSE NUMBEA E
TYPE
@ lM lN lM l Ni Pl Il l0 l0 l-l 010l 0l 0l 0l-l0 l0 l l 4 l 1 l1 l1 l 1]
l0l1l 7 89 14 15 25 26 M
31 32 CATEGORY TYP U
DOCKET NUVBE A EVENT DATE AEPORT DATE h CON'T lP l 0 l gj lLl l 0l 5l 0l-l 012 l 6 l 3l l012 l1 l 7 l 7 l 5 l l 0l 2l 2l 7 l 7l 5l 7 8 57 58 59 60 61 68 89 74 75 80 l EVEN'l DESCAIPTION BE I DURING NORMAL OPERATION, SNUEBER LOCATED OUTSIDE DRYWELL ON ISOLAELE SECTION CF l
7 89 BO
[OTil l SHUTDawN COOLING SUCTION LINE DISCOVERED INOPERAELE DUE TO LOSS OF OIL.
ISOI_ATION l
7 89 80 gg l VALVES UPSTREA'10F AFFECTED PIPE ARE CLOSED DURING NORMAL OPERATION. ONE PFH IOUS l
fSIMILARCCCURRENCE. AFFECTED PART REPLACED IN KIND. (A0 263/75-07)8]
O 7 89 80 0
I I
7 89 80 scaug E
CODE COMPONENT CODE UP5'UE MA A JE A VOLATON O
lClF l lAl lHlAl Nl Gl El P]
lAl l Bl 2 l1l 0]
lN l 7 89 10 11 12 17 43 44 47 48 CAUSE DESCRIPTION gg l A BERGEN-PATERSON FDDEL HSSA-10 SNUEEER L9ID OIL DUE TO CUT 0-FING. AREA l
7 89 BD 019 l AROUND 0-RING GALLED.
SNUBBER LAST REBULT 01/17/74. SUBSEQUENT SNUBEER l
7 89 BO
@l MAIhTENANCE EXPERIENCE SHOULD MINIMIZE POSSIBILITY OF RECLERENCE.
l FACiuTv VETHCO Os STATUS
% POWE A DTHER STATUS OlSCOVEAv DtSCOVEAv OE SCAIPTCN tzj l al ol of I xx i
i Cl I
xA I
7 8 9
"D 12 13 44 45 46 80 AELE EO DS i ASE AMOut.T CF ACT VT v LOCATON OF RELEASE 1
iz l LIJ l
KA I
I KA I
7 8 9
10 11 44 45 80 PERSONNEL EXPOSUAES NUMBER TYPE OESCA1PTCN FiTillololof I El l
NA l
7 89 11 12 13 80 PERSONNEL INJUAlE::i NUMBE A OF.SC Aip'CN L0101Ol I KA I
14 7 89 11 12 80 OFFSITE CONSEGLENCES
]l KA l
7 89 BJ LOSS OR DAMAGE TO FACILITY TvPE OESCAIPTON h
! NA l
7 89 10 80 PUBLICITY l NA l
1 7 89 80 ADDITIONAL FACTORS na i NA l
7 89 80 l
l 19 7 89 80 m D. W f.2/295-5151 NAVE mgy7 GPC 801 587 9102130524 750227 CF ADOCK 05000263 CF
fk l
'E NORTHERN STATES POWER COMPANY Minneapolis, Minnesota 55401 February 27, 1975
.3 Mr. A. Giambusso, Director Division of Reactor Licensing U S Nuclear Regulatory Comission Washingten, D. C.
20555
Dear Mr. Giambusso:
mXIICELLO NUCLEAR GEFEFATING PLuT Docket No. 50-263 License No. DPR-22 Licensee Event Report to the NRC Inoperable Hydraulic Shock Suppressor ne Licensee Event Report for this occurrence is reproduced on the back of this letter.
In addition, two suppressors located on the HPCI system were found to be leaking oil.
Inspection of the snubbers indicated that the leaks were caused by cut or defomed seals which apparently occurred during assembly of the suppressors. Also sand was found in the accumulators of the two suppressors which were on the HPCI system. These two suppressors and other suppressors originally purchased for installation associated with the addition of the four relief valves and the PRT System were sandblasted and repaintec prior to ship-ment to the site.
It is believed that the sand entered the accunulator blocks during the sandblasting operation.
Inspections of other snubbers that fit this category to-date, have revealed no detrinental effects.
It is planned to renove a representative sample of this group of snubbers during the next refuel-ing cutage for detailed inspection.
Yours very truly, dz'd. '
L. O. Mayer, PE Manager of Nuclear Support Services II?Vkik I
cc: J G Keppler
[
G Charnoff Minnesota Pollution Control Agency Attn: E A Pry:ina n ; 7n Ls *~