LICENSEE EVENT REPORT CONTROL BLOCK l l
l l
l l
l (pLEASE PRINT ALL REQUIRED INFO! MOTION) 1 6
vr1 i[hi E
T FE UCE Nit NUVBfC h lM lN l Ml Nl Pl 1}
l0 l0 l-l 0l 0l 0l Ol0 l-l 0 l 0 l l 4l 1 l1l 1l 1l l 0l 1l 7 89 14 15 25 26 30 31 32
?P DOCLET NUVBEP E VE NT DATE REPOQT DATE C AT E GDP' S
h CONT lp h l l Tl lL l l0 !5 lO!- ! O! 2l 64 3l l0 l5 l0 l 5 l 7l 5l l 0l511 l5 l 7 l 5 l 7 6 57 SS 59 60 61 68 09 74 75 80 EVENT DESCRIPTION O
l DPPTNr NrvyAt OPrvATTON CONTR0T CIRCUIT FOR FCIC TURBINE STEAM SUPPT.Y VALVE MO 2078 l
80 7 89
$ l DISCOVERED DEE' ERCTZED DUE TO OPE': UNDERVOLTAGE REIAY COIL.HPCI AVAIIABLE AND l
80 7 89 Twr nr nrrrroNrF TWO PPr"1OUS SIMLAR OCCURRE!CES "0T REPORTABLE.
l 0
lnurpf.yTrAm 80 7 89 M l AFFECTED PART REPLACED IN RIND.
A0 263/75-08.
l 80 7 89 l
hl 80 7 89 pau; S YSTE M CAUSE COMPONENT CouPONENT CODE CODE COMPONENT CCDE SUPPL E E VANUFACTUREA voLATON O
l rlr l l rl l R l B l Ll Al Yl X l lAl l Gl Ol 810l l Yl 7 89 10 11 12 17 43 44 47 48 CAUSE DESCAlPTION O
l A GE7 ERAT FT ECTRIC MODEL 393B20962 250/275 VDC l'NDERVOLTAGE RELAY COIL OPE' ED l
80 7 89 E l CAUSING RET.AY TO DROP OUT AND DEENERCIZE MOTOR CONTROL CIRCUIT.
INVESTIGATION OF l
80 7 89 10 l CAPSE OF COIT FATLURE CO'!TINUES SO THAT RDIEDIAL ACTI ONS MAY BE DETERMINED.
l 80 7 89 FACtiv METHOD OF ETATUS
% POWE A OTHEA STAvUS D!SCOVE A*
DrSCOVE RY DE scars'T ION 3
W l1 l 0l 0 l l N/A l
lBl l N/A l
7 8 9
10 12 13 44 45 46 80 ACirvriv CONT E NT AELEASED OF AELEASE AMOUNT C5 ACTVT v LOCATION CF AELE ASE 12 l Zl d
lN/A l
l N/A l
7 8 9
10 11 44 45 80 r
r PERSONNEL EXPOSURES NUMBE A T Y PE DESCATPTION i
f W l 0l0 l 0 l d lN/A l
80 l
7 89 11 12 13 l
PERSONNEL INJURIES NuvBE R DE SC A1PTION 81010 l 01 I N /A l
l 7 89 11 12 80 I,
OFFSITE CONSEQUENCES gg l N/A
[
80 l 4 7 89 j
LOSS OR DAMAGE TO FACILITY l
T Y PE DESCA* T N d
lN/A l
f 1
80 l
7 89 10 PUBLICITY 1
lN/A l
7 89 9102130483 750515 Bo CF ADOCK 05000263 4
ADDITIONAL FACTORS CF 1B l N/A l
l 7 89 80 l
l\\
@l l
80 P P 612/295-5151 NAME; BYRON D.
DA.
pggy,.
f.P 0 est.ss?
'^
r 6
\\
May 15, 1975
\\
~
.~
Mr.
Giambusso, Director Division of Reactor Licensing U. S. Nuclear Regulatory Co=nission
'~
~
Washington, D. C.
20555
Dear Mr. Giambusso:
MONTICELLO NUCLEAR GE"ERATING PLANT Docket No.
50-263 License No. DPR-22 Licensee Event Report to the NRC Inoperable RCIC Steam Supply Valve The Licensee Event Report for this occurrence is reproduced on the back of this letter.
Yours very truly, M A' l L. O. Mayer, PE Manager, Nuclear Support Services cc:
J. G. Kepper G. Charnof f Minnesota Pollution Control Agency Attn:
E. A. Pryzina r'og U
-over-
- -