ML11235A630

From kanterella
Revision as of 11:27, 3 August 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Arkansas Nuclear One-2011-08 DRAFT-Outline Comments
ML11235A630
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 08/26/2011
From:
Office of Nuclear Reactor Regulation
To:
References
50-313/11-08
Download: ML11235A630 (2)


Text

Attachment 6 OBDI 202 - IOLE Process DRAFT OUTLINE COMMENTS Facility: AN1 First Exam Date:

August 26, 2011 Written Exam Outline (Sent June 9, 2011

) Comment Resolution 1 On the ES-401-4 (RO Exam), the second item (062 AA1.05) says that there isn't any procedural guidance on how to address CCW system (ICW at ANO U1) effects/perturbations as a result of loss of Nuclear Service Water. Is there a corrective action document to track resolving this issue?

Discussed, no issue needing a corrective action document.

2 In the SRO outline, there were two items where the K/A topic described didn't match the K/A number provided. The K/A number should be the one randomly selected in the outline building process, and the description should match it.

- Tier 2, Group 1: 007 Pressurizer Relief/Quench Tank, says K/A is A2.01, but one described is A2.02 - Tier 2, Group 2: 045 Main Turbine Generator, says K/A is A2.07, but one described is A2.17 Copy submitted with draft exam corrected these issues.

Administrative JPM Outline (Sent June 9, 2011

) Comment Resolution 1 On the ES-301-1, the descriptions need to provide information that describing the JPM. The K/A is re

-written, but no description to correlate to the K/A statement is provided.

The 2010 exam outlines provide an example.

The licensee expanded the text to provide a description of the JPMs in the ES

-301-1 forms. Control Room / In

-Plant System JPM Outline (Sent June 9, 2011

) Comment Resolution 1 (Editorial) For Simulator JPM a, fill in the Importance Rating for SROs.

Resolved based on revisions made during exam development process.

2 On the ES-301-2, it says that there are 2 Resolved based on revisions made during Attachment 6 OBDI 202 - IOLE Process Emergency or Abnormal In

-Plant JPMs. JPM i is the "E" classified one to meet this. JPM d would not meet this.

exam development proce ss. Simulator Scenario Outline Comments (Sent June 9, 2011

) Comment Resolution 1 2 3 4 5