Category:Letter
MONTHYEARL-2024-175, Cycle 34 Core Operating Report2024-10-24024 October 2024 Cycle 34 Core Operating Report ML24291A2882024-10-24024 October 2024 Westinghouse Topical Report - Request for Withholding Information from Public Disclosure L-2024-177, Revised Response to Requests for Additional Information Regarding Turkey Point License Amendment Request 277, Updated Spent Fuel Pool Criticality Analysis2024-10-22022 October 2024 Revised Response to Requests for Additional Information Regarding Turkey Point License Amendment Request 277, Updated Spent Fuel Pool Criticality Analysis ML24276A2302024-10-16016 October 2024 Westinghouse Topical Report – Request for Withholding Information from Public Disclosure ML24289A2372024-10-15015 October 2024 Transmittal of Revision 1 Additional Errata Pages for WCAP-18830-P (Proprietary) and WCAP-18830-NP (Non-Proprietary), Turkey Point Fuel Storage Criticality Analysis for 24 Month Cycles L-2024-118, Fleet License Amendment Request to Relocate Staff Qualifications from Technical Specifications to the Quality Assurance Topical Report (FPL-1)2024-10-0808 October 2024 Fleet License Amendment Request to Relocate Staff Qualifications from Technical Specifications to the Quality Assurance Topical Report (FPL-1) L-2024-157, Response to Requests for Additional Information Regarding License Amendment Request (278) to Facilitate a Transition to 24-Month Fuel Cycles2024-10-0303 October 2024 Response to Requests for Additional Information Regarding License Amendment Request (278) to Facilitate a Transition to 24-Month Fuel Cycles IR 05000250/20243012024-10-0303 October 2024 NRC Operator License Examination Report 05000250/2024301 and 05000251/2024301 L-2024-147, Submission of Periodic Reports2024-10-0101 October 2024 Submission of Periodic Reports L-2024-158, Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes2024-09-25025 September 2024 Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes ML24269A1292024-09-24024 September 2024 Response to Requests for Additional Information Regarding Turkey Point License Amendment Request 277, Updated Spent Fuel Pool Criticality Analysis ML24260A2262024-09-18018 September 2024 NRC Examination Results Summary - Examination Reports: 05000250/2024301 and 05000251/2024301 ML24262A2272024-09-18018 September 2024 Transmittal of Additional Errata Pages for WCAP-18830-P (Proprietary) and WCAP-18830-NP (Non-Proprietary), Turkey Point Fuel Storage Criticality Analysis for 24 Month Cycles ML24158A0052024-09-17017 September 2024 Completion of Subsequent License Renewal Site Specific Environmental Review and Modification to Subsequent Renewed Facility Operating Licenses L-2024-136, Supplement to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes2024-09-16016 September 2024 Supplement to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes ML24256A1132024-09-13013 September 2024 Regulatory Audit Summary Related to the Review of Regarding the Updated Spent Fuel Pool Criticality Safety Analysis License Amendment Request ML24207A0342024-09-13013 September 2024 – Exemption from Certain Requirements of 10 CFR 50.46 for Use of Axiom Fuel Rod Cladding – Letter IR 05000250/20240052024-08-23023 August 2024 Updated Inspection Plan for Turkey Point Units 3 & 4 - Report 05000250/2024005 and 05000251/2024005 ML24234A0062024-08-22022 August 2024 Project Manager Assignment L-2024-106, Fifth and Sixth 10-Year Inservice Testing Interval Relief Request No. VR-022024-08-12012 August 2024 Fifth and Sixth 10-Year Inservice Testing Interval Relief Request No. VR-02 L-2024-122, Core Operating Limits Report2024-08-12012 August 2024 Core Operating Limits Report IR 05000250/20240112024-08-0606 August 2024 Comprehensive Engineering Team Inspection (CETI) Inspection Report 05000250/2024011 and 05000251/2024011 ML24163A0012024-08-0505 August 2024 LTR-24-0119-1-1 Response to Nh Letter Regarding Review of NextEras Emergency Preparedness Amendment Review L-2024-089, Notification of Deviation from Pressurized Water Owners Group (PWROG) Report WCAP- 17 451-P. Revision 1. Reactor Internals Guide Tube Wear - Westinghouse Domestic Fleet Operational Projections2024-07-25025 July 2024 Notification of Deviation from Pressurized Water Owners Group (PWROG) Report WCAP- 17 451-P. Revision 1. Reactor Internals Guide Tube Wear - Westinghouse Domestic Fleet Operational Projections L-2024-125, Notice of Intent to Provide Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes2024-07-24024 July 2024 Notice of Intent to Provide Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes ML24184B2822024-07-16016 July 2024 – Request to Use a Later Code Edition and Addenda of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI ML24193A2432024-07-12012 July 2024 – Interim Audit Summary Report in Support of Review of License Amendment Requests Regarding Fleet Emergency Plan L-2024-114, Quality Assurance Topical Report (FPL-1 Revision 31 Annual Submittal2024-07-10010 July 2024 Quality Assurance Topical Report (FPL-1 Revision 31 Annual Submittal 05000250/LER-2024-002-01, Condition Prohibited by Technical Specifications2024-07-10010 July 2024 Condition Prohibited by Technical Specifications ML24173A1902024-06-28028 June 2024 Withdrawal of an Amendment Request ML24159A2652024-06-26026 June 2024 Correction of Safety Evaluation for Issuance of Amendment Nos. 298 & 291 Regarding Revising the Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project L-2024-102, Official Service List Update2024-06-19019 June 2024 Official Service List Update L-2024-100, Withdrawal of License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement Project2024-06-19019 June 2024 Withdrawal of License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement Project ML24149A2862024-06-12012 June 2024 NextEra Fleet - Proposed Alternative Frr 23-01 to Use ASME Code Case N-752-1, Risk-Informed Categorization and Treatment for Repair/Replacement Activities in Class 2 and 3 Systems Section X1, Division 1 (EPID L-2023-LLR-0009) - Letter IR 05000250/20244012024-06-0505 June 2024 – Security Baseline Inspection Report 05000250-2024401, 05000251-2024401 and 07200062-2024401 L-2024-076, Reply to Notice of Violation; NOV 05000250, 05000251/2024010-052024-05-29029 May 2024 Reply to Notice of Violation; NOV 05000250, 05000251/2024010-05 L-2024-082, 2023 Annual Radiological Environmental Operating Report2024-05-15015 May 2024 2023 Annual Radiological Environmental Operating Report IR 05000250/20240012024-05-10010 May 2024 Integrated Inspection Report 05000250/2024001 and 05000251/2024001 ML24127A1862024-05-0909 May 2024 Request for Withholding Information from Public Disclosure ML24135A0942024-05-0909 May 2024 Periodic Update to the Updated Final Safety Analysis Report L-2024-060, 10 CFR 50.59(d)(2) Evaluation and 10 CFR 50.71(e)(2) Technical Specification Bases Summaries Report2024-05-0909 May 2024 10 CFR 50.59(d)(2) Evaluation and 10 CFR 50.71(e)(2) Technical Specification Bases Summaries Report ML24127A0632024-05-0606 May 2024 Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes L-2024-072, Cycle 33 Core Operating Limits Report2024-05-0101 May 2024 Cycle 33 Core Operating Limits Report IR 05000250/20240102024-05-0101 May 2024 Design Basis Assurance Inspection Programs Inspection Report 05000250/2024010 and 05000251/2024010 and Notice of Violation L-2024-073, Cycle 34 Core Operating Limits Report2024-05-0101 May 2024 Cycle 34 Core Operating Limits Report L-2024-048, Divider Plate Assemblies Bounding Analysis Evaluation for Subsequent License Renewal Commitment Revision2024-04-30030 April 2024 Divider Plate Assemblies Bounding Analysis Evaluation for Subsequent License Renewal Commitment Revision L-2024-069, Radiological Emergency Plan Revision 762024-04-22022 April 2024 Radiological Emergency Plan Revision 76 L-2024-066, Sixth 10-Year Inservice Testing Interval Relief Request No. PR-022024-04-17017 April 2024 Sixth 10-Year Inservice Testing Interval Relief Request No. PR-02 05000250/LER-2024-002, 0 for Turkey Point, Unit 3 - Condition Prohibited by Technical Specifications2024-04-11011 April 2024 0 for Turkey Point, Unit 3 - Condition Prohibited by Technical Specifications ML24096A2142024-04-0505 April 2024 Ltr. to David Hill, Principal Chief, the Muscogee (Creek) Nation, Re., Section 106 Letters for Turkey Point 2024-09-25
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 245 PEACHTREE CENTER AVENUE NE, SUITE 1200 ATLANTA, GEORGIA 30303
-1257 July 31, 2014 Mr. Michael Kiley Turkey Point Nuclear Plant Vice President Florida Power & Light Company 9760 SW 344 th St. Florida City, FL 33035
SUBJECT:
EXTENSION OF NOTICE OF ENFORCEMENT DISCRETION (NOED) FOR FLORIDA POWER AND LIGHT COMPANY (FPL) REGARDING TURKEY POINT NUCLEAR GENERATING STATION UNITS NOS. 3 AND 4 [NOED NO. 14 001]
Dear Mr. Kiley:
By letter dated July 29, 2014, you requested that the NRC extend the NOED to not enforce compliance with Technical Specification (TS) 3.7.4 that was verbally granted on July 20, 2014 and document ed by letter dated July 23, 2014
. Your letter documented information previously discussed with the NRC in telephone conference s on July 20, and July 29, 2014. The principal NRC staff members who participated in the July 29, 2014, telephone conference are listed in the enclosure. The NRC staff determined that the information in your letter requesting the extension of enforcement discretion was consistent with your verbal request. In your letter dated July 29, 2014, you requested an extension of the expiration date of the NOED from 6:00 p.m. July 30, 2014, to 6:00 p.m. August 9, 2014. You stated the ultimate heat sink (UHS) temperatures have continued to cycle near or above the TS limit of 100°F and are anticipated to stay high during the requested extension period. The extension of an additional ten days is consistent with the additional time required for NRC to complete its review of FPL's license amendment request (LAR), which, if approved, would permanently revise the UHS temperature limit.
In addition, you requested a modification to the actions FPL will take should the UHS temperature exceed 103°F during the remaining period that this NOED is in effect. Specifically, during any time interval where the UHS average supply water temperature exceeds 103°F, FPL will invoke the Action Statement associated with TS 3/4.7.4 to place both units in at least Hot Standby within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in Cold Shutdown within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. This action is the same as the Action Statement associated with the increased UHS temperature in the LAR.
Your extension request states, in part, that FPL continues to remain in a period of high system load demand and the operation of Turkey Point Units 3 and 4 during the summer months is essential for grid voltage stability in southern Florida
. The NRC staff considered this and additional information obtained from the independent entity (Florida Reliability Coordinating Council) in determining if taking Turkey Point Units 3 and 4 offline would challenge the ability to maintain an adequate voltage profile throughout the system and could result in adverse consequences to the health and safety of the public
.
M. Kiley 2 During the telephone conference with the NRC on July 29, 2014, at 4:30 p.m.,
you confirmed that there were no changes to the compensatory actions you committed to in your letter dated July 21, 2014. Your letter dated July 29, 2014 added the additional commitment that during any time interval where the UHS average supply water temperature exceeds 103°F, FPL will invoke the Action Statement associated with TS 3/4.7.4 to place both units in at least Hot Standby within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in Cold Shutdown within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
NRC staff also considered your calculated Incremental Conditional Large Early Release Probability values for Units 3 and 4, and found they did not exceed the threshold guidance provided in Inspection Manual Chapter 0410, "Notices of Enforcement Discretion" and were consistent with values calculated by NRC risk analysts. In addition, the conditions and actions noted above have been, and will be, subject to independent verification by NRC inspectors.
On the basis of the NRC staff's evaluation of your request, I have concluded that granting this extension to the original NOED period and modification of one exit criterion is consistent with the Enforcement Policy and NRC staff guidance and has no adverse impact on public health and safety or the environment.
This determination was qualitative and based upon balancing the effect on public health and safety of not operating, against the potential radiological or other hazards associated with continued operation (Inspection Manual Chapter 0410, Section 06.02.b, (i.e., natural event NOED)). Therefore, we will extend our intention to exercise discretion to not enforce compliance with TS LCO 3.7.4 from 6:00 p.m., on July 20, 2014 until one of the following end conditions is met: (a) 6:00 p.m. on August 9, 2014, or (b) the UHS peak temperature drops below 96°F for three consecutive days and is on a declining trend; or (
c) an NRC decision on the requested license amendment; or (
d) if the loss of Turkey Point Units 3 and 4 will not result in a North American Electric Reliability Corporation (NERC) Emergency Alert Level (EEA) 3 alert.
It is also noted that your license amendment request is being reviewed by NRC staff and treated as an exigent amendment
. As stated in the Enforcement Policy, action will be taken, to the extent that violations were involved, for the root cause that led to the non
-compliance for which this NOED was necessary.
Sincerely,
/RA/ Victor M. McCree Regional Administrator Docket No s.: 50-250, 50-251 License No s.: DPR-31, DPR-41
Enclosure:
List of Participants cc: Distribution via Listserv
__ ML14213A069
_____ X SUNSI REVIEW COMPLETE FORM 665 ATTACHED OFFICE RII:DRP RII:DRP RII:DRP DORL RII:ORA RII:RA SIGNATURE
/DED/ ?MSL1/ /JTM /VIA E-Mail/ /LXW1/ /VMM/ NAME DDumbacher MLesser JMunday RLantz LWert VMcCree DATE 7/31/2014 7/31/2014 7/31/2014 7/31/2014 7/31/2014 7/31/2014 E-MAIL COPY?
YES NO YES NO YES NO YES NO YES NO YES NO YES NO M. Kiley 3 Letter to Michael Kiley from Victor M. McCree dated July 31, 2014
SUBJECT:
EXTENSION OF NOTICE OF ENFORCEMENT DISCRETION (NOED) FOR FLORIDA POWER AND LIGHT COMPANY (FPL) REGARDING TURKEY POINT NUCLEAR GENERATING STATION UNIT NOS. 3 AND 4 [NOED NO. 14 001] DISTRIBUTION
- L. Douglas, RII EICS OE Mail (email address if applicable)
RIDSNRRDIRS PUBLIC RidsNrrPMTurkeyPoint Resource
Enclosure List of Participants NRC Region II Victor McCree, Regional Administrator Joel Munday, Director, Division of Reactor Projects (DRP)
Mark Lesser, Deputy Director, DRP David Dumbacher
, Acting Chief, Reactor Projects Branch (RPB) 3, DRP Wesley Deschaine, Acting Senior Project Engineer, RPB 3, DRP George McDonald, Senior Risk Analyst, DRP Timothy Hoeg, Turkey Point Senior Resident Inspector, DRP Matthew Endress, Turkey Point Resident Inspector, DRP NRC Headquarters (All Headquarters participants are in the Office of Nuclear Reactor Regulation)
Ryan Lantz, Deputy Director, Division of Operating Reactor Licensing (DORL) Robert Taylor, Deputy Director, Division of Safety Systems (DSS) Lisa Regner, Chief, Plant Licensing Branch II
-2 (LPLII-2), DORL Greg Casto, Chief, Balance-of-Plant Branch (SBPB), DSS Jacob Zimmerman, Chief, Electrical Engineering Branch, Division of Engineering Sheldon Stuchell, Chief, Generic Communications Branch, Division of Policy and Rulemaking See-Meng Wong, Sr. Risk Analyst, PRA Licensing Branch, Division of Risk Assessment Gerald Purciarello, Senior Reactor Systems Engineer, SBPB, DSS Matthew Hamm, Reactor Systems Engineer, Technical Specifications Branch, DSS Audrey Klett, Project Manager, LPLII-2, DORL