Text
'
j Re:
St. Lucie Unit Nos.
I & 2 Docket Nos. 50-335 & 50-389 Conformance to Regulatory Guide l.97 II *I I 0
(
[
I I
"0 I
(
I(IT.
LUCIE PLANT UNIT NO. I ENGINEERING EVALUATION OFiINSTRUMENTATIONSYSTEM FOR REGULATORY'GUIDEil.97, REV; 3 I
I I
I 'l DATE:
Revision I
October l 985 8511210179 851118 PDR ADOCK 05000'335 E
PDR rmX@OR~ Wl.llzriKNC
J
~ II ll-
St. Lucie Unit 1 Revision 1 SECTION TABLE OF CONTENTS DESCRIPTION PAGE NO.
IV.
V.
VI.
VII.
VIII.
Regulatory Guide 1.97, Rev. 3 Requirements Evaluation Criteria Methodology of Equipment Evaluation Type A Variable List of Parameters List of Systems Requiring Additions, Modifications or Analysis References Conclusions Parameter Listing Summary Sheets 2f 3 4,5 10 1-53
St. Lucie Unit 1 Revision 1 SECTION I REGULATORY GUIDE 1.97, REV. 3 REQUIREMENTS
k
~ vs
~
r.
1
St. Lucie Unit 1 Revision 1
Regulatory Guide 1.97, Rev. 3, titled "Instrumentation for Light-Water-Cooled Nuclear Power Plants to Assess Plant and Environs Conditions During and Pollowing an Accident", divides all instrumentation used for Post Accident Monitoring into five functional types as shown below:
Type A Variables: those variables to be monitored that provide the primary information required to permit the control room operator to take specific manually controlled actions for which no automatic control is provided and that are required for safety systems to accomplish their safety function for design basis accident events.
Primary information is information that is essential for the direct accomplishment of the specified safety functions; it does not include those variables that are associated with contingency actions that may also be identified in written procedures.
Type B Variables: those variables that provide information to indicate whether plant safety functions are being accomplished.
Plant safety functions are (1) reactivity control, (2) core
- cooling, (3) maintaining reactor coolant system integrity, and (4) maintaining containment integrity (including radioactive effluent control).
Type C Variables:
those variables that provide information to indicate the potential for being breached or the actual breach of the barriers to fission product releases.
The barriers are (1) fuel cladding, (2) primary coolant pressure boundary, and (3) containment.
Type D Variables:
those variables that provide information to indicate the operation of individual safety systems and other systems important to safety.
These variables are to help the operator make appropriate decisions in using the individual systems important to safety in mitigating the consequences of an accident.
Type E Variables:
those variables to be monitored as required for use in determining the magnitude of the release of radioactive materials and continually assessing such releases.
Post Accident Monitoring Instrumentation is divided into three categories based on the degree of equipment qualification requirements, redundancy, power
- sources, channel availability, quality assurance, and display and recording requirements.
In general, Category 1 provides for fullqualification, redundancy, and continuous real-time display and requires on-site (standby) power.
Category 2 provides for qualification but is less stringent in that it does not (of itself) include seismic qualification, redundancy, or continuous display and requires only a
high-reliability power source (not necessarily standby power).
Category 3 is the least stringent.
It provides for high-quality commercial grade equipment that requires only offsite power.
h I
h I,
II I
h It
St. Lucie Unit 1 Revision 1 SECTION II EVALUATIONCRITERIA
li,
St. Lucie Unit 1 Revision 1 Our review of RG 1.97, Rev. 3 requirements applicable to operating plants shows that the requirements of this guide cover the requirements of 10 CFR 50.49 and NUREG 0737 and its subsequent clarification and generic letter 82-33.
The following is the evaluation criteria used in this report for the three different categories as defined in the Regulatory Guide 1.97, Rev. 3, Table 1.
1.
ENVIRONMENTALQUALIFICATIONCRITERIA a.
Cate or 1 Instrumentation (a).
Instrumentation located in harsh environment should comply with 10 CFR 50.49 requirements and NUREG 0588 Category 1
(II?EE-323, 1974).
(b).
Instrumentation located in mild environments do not have to be up-graded if they withstand their service location conditions under normal and emergency conditions.
b.
Cate or 2 Instrumentation (a).
For safety related instrumentation, follow the same criteria used for category 1 instrumentation.
(b).
Non-nuclear safety related instrumentation located in harsh environment has to be qualified per NUREG 0588 category 1.
(c).
Instrumentation located in mild environment should follow the same criteria used for category 1 instrumentation.
c.
Cate or 3 Instrumentation Nonnuclear safety related instrumentation has to withstand its service location conditions.
2.
SEISMIC UALIFICATIONCRITERIA Category 1 and Safety Related Category 2 instrumentation:
The equipment shall comply with IEEE-344, 1975.
(Reg.
Guide 1.100)
Category 3 and non safety related related category 2 instrumentation:
No specific provision required.
3.
REDUNDANCY Only category 1 instrumentation should be provided with redundant or diverse channels, electrically independent, and physically separated from each other, and from non~fety equipment, in accordance with Reg. Guide 1.75 "Physical independence of electric systems",
up to and including any isolation device.
Category 2
and 3 instrumentation do not require redun ance.
r C
N
(
ft H
M I
St. Lucie Unit 1 Revision 1 4.
POWER SOURCES a.
cateaCor r 1 Instrumentation to be supplied from 120 VAC uninterruptible power
- source, or from 120 VAC Offsite Power supply, backed up by an Emergency Diesel Generator if momentary interruption of power is acceptable.
b.
~Cate or 2
Instrumentation to be supplied from high reliability power source which can be either from:
1.
2.
3.
4, 120 VAC uninterruptible, or 120 VAC Offsite Power backed by an Emergency Diesel Generator, or 125 VDC safety-related battery, or 125 VDC non-safety related battery o.
~Cate or 3
No specific provisions required.
5.
UALITY ASSURANCE Qualified equipment (category 1
and safety related category 2
should comply with the Regulatory Guides listed in Table 1 of Reg. Guide 1.97 Rev.3.
6.
DISPLAY AND RECORDING Category 1 Instrumentation should be displayed on a real-time display.
The indicator may be on a dial, digital display, CRT or strip chart recorder.
Recording of instrumentation readout should be provided for at least one redundant channel.
Where dedicated strip chart recorder is not provided, recording should be updated and stored in computer memory and displayed on demand.
Category 2 Instrumentation should be displayed on an individual instrument or it may be processed for display on demand.
Signal from effluent radioactivity and area monitors should be recorded.
Category 3 Instrumentation.
(Same as Category 2).
Signal from effluent radioactivity, area and meteorology monitors should be recorded.
0 A
R
St. Lucie Unit 1 Revision 1 SECTION III METHODOLOGY OP EQUIPMENT EVALUATION
St. Lucie Unit 1 Revision 1
We have evaluated existing system arrangements and identified components for variables Types A thru E and their conformance to Reg. Guide 1.97, Rev.
3 requirements applicable to existing plant.
Based on our interpretation of Reg.
Guide 1.97, Rev. 3 all Post Accident Monitoring instrumentation can be divided into three groups as shown below:
1.
ORIGINALSAFETY RELATED INSTRUMENTATION The original, safety related instruments located in harsh environment has been or will be replaced by qualified instruments per our commitment in response to bulletin 79-01B, 10CFR 50.49 or by this report.
The instruments located in mild environment do not require specific qualification until revision of the Regulatory Guide 1.89 is published.
The original safety related instrumentation generaDy comply with the seismic qualification program which was the basis for plant licensing.
2.
ADDED OR REPLACED SAFETY RELATED INSTRUMENTATION The added or replaced safety related instrumentaton generally comply with the requirements of 10 CFR 50.49 or the latest IEEE standards.
3.
NON SAFETY INSTRUMENTATION These instruments are high quality commercial grade equipment that require no specific qualification, however if the instrument is category 2
located in harsh environment, should be environmentally qualified.
Once the evaluation of all the instrumentation has been completed, a schedule for the implementation of the required modification to comply with the Reg.
Guide requirements has been included.
Section VIII of this report is the Parameter Listing Summary Sheets which includes all the plant instrumentation by tag numbers, grouped in the same order as the Reg. Guide 1.97, by type and categories.
The listing summarizes all the required information to perform the evalution and the results of the evaluation are shown on the column justification/schedule.
If this column is blank, it means that the instrument complies with the requirements of the Reg. Guide 1.97.
The Parameter Listing Summmary Sheets provide the following information:
Item, tag number, variable description, type and category, instrument existing and required
- ranges, Q.
A.
requirements, environmental and seismic qualification, redundance, power
- supply, display
- location, schedule for implementation or justifications.
Variable description
- column, described the variable as listed in the Reg.
Guide 1.97, Rev. 3.
Ih r
h 1
St. Lucie Unit 1 Revision 1 The tag number column, lists all the sensors, indicators, displays and recorders associated with variable described.
In the column "Display Locations, Control Room C.R.", Yes, means that the indicator is located in the control room; SAS means that the data is available in Safety Assessment System (SAS); SPDS means that the data is used for Safety Parameter Display Subsystem (SPDS).
In the Column "Display Location TSC and EOF", Yes, means that the data is available on the computer display in the TSC and EOF.
Finally, section V, lists all systems requiring modification, additions or analysis to comply with the Regulatory requirements.
~
~
l II
St. Lueie Unit 1 Revision 1 SECTION IV TYPE A VARIABLELIST OP PARAMETERS
St. Lucie Unit 1 Revision 1 The type A variable list of parameters, the basis for which is given in Reg. 1.97, Rev.
3, was established.
The following Emergency Operational Procedures (EOPS) were reviewed:
a.
b.
Ce d.
Immediate Action and Diagnostics (E-1)
Loss of Reactor Coolant (E-1)
Loss of Secondary Coolant (E-2)
Steam Generator Tube Rupture (E-3)
As a result of these reviews the following parameters were designated as Type A variables:
1.
2.
3.
4, 5.
Pressurizer Pressure RCS Hot Leg Temperature RCS Cold Leg Temperature Steam Generator Level Narrow Range Containment Hydrogen Concentration
St. Lucie Unit 1 Revision 1 SECTION V LIST OF SYSTEMS REQUIRING ADDITIONS, MODIFICATIONS OR ANALYSIS
I Vk
,'il s
Itl g I
IL
),'ly I
"t
St. Lucie Unit 1 Revision 1 The following is a list of the St. Lucie Unit 81 instrument system, which as a result of this evaluation, requires addition, modification or analysis.
1.
Item B-14 Containment Isolation Valve Position The following valves will be equipped with qualified limit switches and valve position indication will be provided in the control room prior to startup for cycle 7 scheduled for January, 1986:
I-FCV-03-1E I-FCV-03-1F 2.
Item D-6 HPSI Flow The following transmitter will be recalibrated to 400 gpm prior to startup for cycle 7 scheduled for January, 1986:
FT-3311 FT-3313 FT-3321 FT-3323 FT-3331 FT-3333 FT-3341 FT-3343 3.
Item D-32 Decay Tank Gas Pressure Existing pressure gauge ranges willbe changed to 300 psig prior to startup for cycle 7 scheduled for Janaury, 1986:
PI-6650 PI-6651 PI-6652 4.
Item D-33 Emergency Ventilation Damper Position Position indication for the following damper willbe provided in the control room prior to startup for cycle 7 scheduled for January, 1986:
Dl, D2, D3, D4, D7A, D7B, D8A, D8B, D11A, D11B 5.
Item B-13, B-15, C-5 and C-11 Containment Pressure Mid Range and Wide Range f
The transmitters PT-07-4B willbe replaced with Rosemount model prior to startup for cycle 7 scheduled for January, 1986:
6.
Item B-1 Neutron Flux Two redundant safety grade channels willbe installed prior to startup for cycle 7 to comply with the R.G. 1.97 requirements.
I I
II
'1 ll d
St. Lucie Unit 1 Revision 1 7.
All SPDS signals (see Section VII of this report) will be available prior to startup for cycle 7 scheduled for January, 1986.
8.
Information available through the Safety Assessment System (SAS) willbe provided when SAS is fullyimplemented.
St. Lueie Unit 1 Revision 1 SECTION VI REP ERE NCES
P'
St. Lueie Unit 1 Revision 1
REFERENCES Regulatory Guide 1.97, Rev. 3 10 CFR 50.49 Regulatory Guide 1.89 Regulatory Guide 1.100 NUREG 0737, Supplement 1
NUREG 0588 IEEE-323, 1974 IEEE-344, 1975
A
~
5
~
4
~
0 I
St. Lucie Unit 1 Revision 1 SECTION VII CONCLUSIONS
St. Lucie Unit 1 Revision 1 CONCLUSIONS 1.
Based on the information presented in this report, St. Lucie Plant Unit $ 1 will conform with the requirements of Reg. Guide 1.97, Rev.
3 prior to startup for cycle 7.
2.
For instrumentation which does not fully comply with the requirements of Reg. Guide 1.97, Rev. 3, a justification has been provided (Section VIII).
3.
Information available through SAS supplements R.G. 1.97 requirements and willbe provided at the Control Room, TSC, and FPF on Computer Display when SAS is fullyimplemented.
WP/DISCOSL0001/RG 1.97/0685/L St. Lucie Unit 1 Revision 1 SECTION VIII PARAMETER LISTING
SUMMARY
SHEETS
w
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE A V 97 REV 3 SHEET" ES OCTOBER 85 VARIABLE I
REQUIRE IEHVIROHMENTAL CATE-I ITEM TAG NO.
DESCRIPTION TYPE GORY I EXISTING RE UIRED I
MENT UALIFICATION SEISMIC UALIFICATION I
POWER I
REDUNDANCEI SUPPLYI DISPLAY LOCATION I
SCHEDULE/
Al IPT-1107 I
I IPT-1108 Icc IDisplay A I
I I
I lcc IDisplay B Pressur-izer Pressure A
1 I
I I
IO to 3000 IPlant I Comply lpsia ISpecific I
I I
I Note 16 Note 16 Note 11 Note 11 Note 17 Note 17 Note 17I Note 17I I PT-1108 I
I I PT-1107 I
I I Icc I Display B I
I Icc I'Display A I
I INote 1
ISA I
INote 1
ISB I
INote 1
ISA I
INote 1
I I
SAS I Yesl Yesl SPDS Yes Yes A2 ITE-1112CA I
I I
I I
I Ice I
IDisplay A I
I I
ITE-1112CB I
I I
I I
I lcc IDisplay B
I I
I ITE-1122CA I
I I
I I
I lcc I
IDisplay A I
I I
ITE-1122CB I
I I
Icc I
IDisplay 8 I
I I
RCS Cold Leg Temp Loop 1A2 RCS Cold Leg Temp Loop Al RCS Cold Leg Temp Loop 1B1 RCS Cold Leg Temp Loop 1B2 1
I 212'F to I705 F 1
l212'F to I7050F I
I I
I 1
l212'F to l70s F
I I
I I
1 l212 F to I70s F I
I I
I Iplant I
Comply ISpecific Plant I Comply ISpecific I Plant I
ISpecific Comply Iplant I Comply ISpecific Note 16 Note ll Note 16 Note 11 Note 16 Note 11 Note 16 Note 11 Note 17 Note 17I Note 17 Note 17l Note 17 Note 171 Note 17 Note 17I INote 1
I IMA I
I INote 1
ISA I
I I
INote 1
IMB I
I I
INote 1
ISB I
I I
INote 1
I IMA I
I I
INote 1
IsA I
I I
INote 1
I IMB I
INote 1
ISB I
TE-1122CB I
I I Icc Display B TE-1122CA Icc Display A I TE-1112CB II:
Icc I Display B
I I TE-1112CA I
I I Icc I Display A I
Yes SAS I Yesl Yesl SPDS Yes SAS I
SPDS Yes I
Yesl Yesl SAS I Yesl Yesl SPDS Yes I
SAS I Yesl Yesl SPDS 1150A/0137A
IDA POHER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE A VARIAB 97 REV 3 SHEET" (Cont'd)
OCTOBER 85 ITEM TAG NO.
VARIABLE INSTRUMENT RANGE CATE-I GORY I EXISTING RE HIRED DESCRIPTION TYPE gA REQUIRE I ENVIRONMENTAL UALIFICATION SEISMIC UALIFICATION I
POHER I
REDUNDANCEI SUPPLYI DISPLAY LOCATION CR TSC EOF SCHEDULE/
JUSTIFICATION A3 ITE-1112HA I
I lcc IDisplay A I
ITE-1112HB I
I Ice IDisplay B I
I TE-1122HA I
I Icc IDisplay A I
ITE-1122HB I
I Ice IDisplay B I
RCS Hot Leg Temp Loop 1A RCS Hot Leg Temp Loop 1B 1
I 212'F to IPlant I 705'F ISpecif ic I
I 1
l212'F to IPlant I705'F ISpecific I
I Comply Comply Note 16 Note 11 Note 16 Note 11 Note 16 Note 11 Note 16 Note ll I Note 17 Note 17I Note 17 Note 17I Note 17 Note 17I Note 17
~ Note 17I TE-1112MB I
I Icc I Display B I
I TE-1112HA I
I Icc I Display A I
I TE-1122HB I
I Icc I Display B
I I TE-1122HA I
I Icc I Display A I
INote 1
I IMA I
INote 1
I IsA I
I I
INote 1
IMB I
INote 1
I Isg I
I I
INote 1
I IMA I
INote 1
IsA I
I I
INote 1
I IMB I
INote 1
I ISB I
SAS I YesI YesI SPDS Yes SAS I YesI YesI SPDS I
Yes I
I I
I SAS I YesI YesI I
I I
I SPDS Yes SAS I Yesl YesI SPDS Yes A4 I LT-9013A I
I I LT-9013B I
I I LT-9013C I
I I LT-9013D I
I I LIC-9013A I
I I LICH013 B I
I ILIC-90130 I
I ILIC-9013D I
I I LR-9013A SG 1A1 Level (Narrow Range) 0 to 100X I
Plant Specific Comply Comply Comply Comply Comply I
I I
Comply I
I I Comply I
I I
Comply I
I I Comply I
I Note 16 Note 16 Note 16 Note 16 Note ll" Note 11 Note 11 Note 11 Note 11 Note 17 Note 17 Note 17 Note 17
'Note 12 Note 12 Note 12 Hote 12 Note 12 I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I INote 1
I IMA I
I I
INote 1
I MB I
I I
INote 1
I IMG I
I I
INote 1
IMD I
I I
INote 1
I IMA I
I I
INote 1
IMB I
I I
INote 1
I IMC I
I I
INote 1
I IMD Note MA LT-9013D LT-9013C LT-9013B LT-9013A LIC-9013D LIC-90130 LIC"9013B LIC"9013A SAS I YesI Yesl SPDs I
I I
I I
I SAS I Ye s I Ye s I spDs I
I I
I I
I I
I SAS I Yes YesI SPDS Yes Yes Yes Yes Yes 1150A/0137A
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY G "PARAMETER S TYPE A VARIAB 97 REV 3 SHEET" (Cont'd)
OCTOBER 85 VARIABLE INSTRUMENT RANCE QA ITEM TAG NO.
LT-9023A DESCRIPTION I
SG 1B1 I Level I (Narrow I Range)
I I
I I LT-9023B I
I I LT 90230 LT-9023D LIC-9023A ILIC-9023B I
I I
I LIC"90230 I
I ILIC-9023D I
LR-9023A TYPE I
GORY I EXISTING RE UIRED 0 to 132 IPlant Inches ISpecific IO to 100X I
Comply UALIFICATION Note 16 Comply Note 16.
Comply Note 16 Comply Note 16 Comply 'ote 11:
Comply Note 11 Comply Note 11 Comply Note 11 Comply Note 11 REQUIRE IENVIRONMENTAL SEISMIC UALIFICATION Note 17 Note 17 Note 17 Note 17 Note 12 Note lf Note 12 Note 12 Note 12 I LT-9023D I
I I LT-90230 I
I I LT-9023B I
I I LT-9023A I
I I LIC-9023D I
I I LIC-90230 I
I I LIC-9023B I
I I LIC-9023A INote 1
I IMA I
I I
I Note 1
I IMB I
I I
INote 1
I IMC I
INote 1
IMD I
I INote 1
~ I IMA I
I I
INote 1
I 1MB I
I I
INote 1
I IMC I
I I
INote 1
I IMD I
I I
INote 1
I IMA I
I POWER I
REDUNDANCEI SUPPLYI SAS Yesl Yesl spDs I
I I
I I
SAS I Yes I Yes l I
I I
I Yesl Yesl SPDS SAS SPDS SAS SPDS Yes Yes Yes Yes Yes Yes Yes DISPLAY LOCATION CR TSG EOF SCHEDULE/
JUSTIFICATION I
I I
Hydrogen IContainment
- Sampling, IHydrogen I& AnalyzerlConcentra-ICubicle SAltion I
Hydrogen Sampling I
& Analyzerl ICubicle SBI Hydrogen Analyzer Ind I
Recording I
I Cubicle SAI I
IHydrogen IAnalyzer I Ind IRecording ICubicle SBI I
I 1
IO to 10X I
I (Capable I
lof Oper-I ating l from -5 Ipsig to l44 psig)
I I
I Plant Specific Comply Note 11 Note ll Note 11 Note 11 h
Note 12 Note 12 Note 12 Note 12 IHydrogen ISampling I& Analyzer ICubicle SB I
IHydrogen ISampling I& Analyzer I Cubicle SA I
IHydrogen IAnalyzer IInd &
IRecording ICubicle SB I
IHydrogen IAnalyzer I Ind IRecording I Cubicle SA I
INote 2 I
ISA I
I I
I I
I I
INote 2 I
ISB I
I I
INote 2 I
ISA I
I I
I INote 2 I
ISB I
I I
SAS I Yesl Yesl SPDS Yes Yes 1150A/0137A
0 0
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE B V 97 REV 3 SHEET" BLES OCTOBER 85 VARIABLE INSTRUMENT RANGE QA ITEM TAG NO.
DESCRIPTION CATE-I I REQUIRE-IENVIRONMENTAL SEISMIC TYPE GORY I EXISTING RE UIRED I
MENT I UALIPICATION UALIPICATION I
POWER I DISPLAY LOCATION I
SCHEDULE/
Bl IRE-26-80A INeutron I
IFlux IRE-26-80B I
I RI-26-80All I
RI-26-80Bll I
I IRR-26-80A I
I I
IRR-26-80B I
I I
1 l2x10 I10 to IComply I to 200Z I
llOOZ of I
IReactor I IPull I
I I power I
I power I
I I
I Note
" Note Note Note Note Note is I I I
ls I I I
18 I I I
18 I I I
is II I
i8 II Note 19 Note 19 Note 19 Note 19 Note 19 Note 19 I
I IIRE-26-80B IINote ill I
IMA II IIRE-26-8A IIMB II I
I I I RI-26-SOB 1 I I I
I IRI-26-BOA1 I I I.
I IIRR-26-808 II I
.=
I IIRR-26-80A I
I II I
Yes II I
Yes II I
Yes II I
Yes I I I
IRefer to sec-I Ition V item I
l6 for install-I lation schedulel I
I I
I I
I I
I I
B2 I Control I Control Rod I
B IRod Posi-IPosition I
Ition Limitl ISvitch I(Quantity I
I 61)
I ICEA IDisplay I
IMetroscopel I
I IDDPS 3
IPull in IPull in lor not lor not Ifull in, Ifull in IAnalog Iposition Ifor any ICEA H/A H/A N/A N/A INote 2AI INS INote 2AI IHS I
I I
INote 2AI INs I
I I
INote 2AI INS I
I Yes Yes Yes IYes IYes ISAS displays SAS I"All In" or I"All Not In" I
4 1150A/0137A
0
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY 97 REV 3 "PARAMETER S SHEET" TYPE B VARIABLES (Cont'd)
OCTOBER 85 I
I ITEMI TAG NO.
B3 AT-2203 IRCS Soluble I
B IBoron Con-Icentration IAR-2203 3
lo to 550 lo to 6000l N/A lppm Ippm I500 to I1050 ppm I 1000 to I
I1550 ppm I
ll500 to 12050 ppm I
N/A N/A VARIABLE I
INSTRUMENT RANGE I
QA CATE-I I
REQUIRE IEHVIRONMENTAL I SEISMIC DESCRIPTION TYPE I
GORY I EXISTING REQUIRED I
MENT IQUALIFICATION IQUALIFICATION N/A INote INS I
INote INS I
I I
2AI I
I 2AI SAS I Yes l Yes l Yes I
POWER I DISPLAY LOCATION SCHEDULE/
JUSTIFICATION See Item E17A I
I I
I B4 ITE 1115 I
I ITI-1115 I
I I TR-1115 I
I ITE-1125 I
I I TI-1125 I
I ITR-1125 RCS Cold Legl Temp lA1 IRCS Cold Legl B
ITemp 1Bl I
I 3
lo'F to I6OO'F 3
IOF to I6000F I50'F to I400 F I50'F to I4OO F N/A N/A N/A N/A N/A N/A N/A N/A INote 2AI INS I
INote 2A INS I
INote 2AI INs I
I I
INote 2AI INS I
I I
INote 2AI INS I
I I
INote 2AI INS I
SAS I
Yes Yes SAS I
Yes Yes Yesl Yesl Yesl Yesl B5 ITE-1112HA IRCS Hot Leg I
B I
ITemp Loop 1AI I
I IICC I
IDisplay A I
I I
ITE-1112HB I
ICC Display B
I I
1 l212'F to I50'F to I
I705'F I700'F Comply Note 16 Note 11 Note 16 Note 11 Note 17 I TE-1112HB I
I Note 17 I
I ICC I Display B I
Note 17 I TE"1112HA I
I Note 17 I
I ICC I Display A I
INote 1
IMA I
INote 1
ISA I
INote 1
IMB I
INote 1
ISB I
SAS I Yesl SFDS I
Yes SAS I Yesl spDs I
Yes Yesl I'Below 350 F I
Ithe (SDC)
I Isystem vill be I
I in operation.
I YeslThen CET's villi Ibe used for I
I for Hot Leg I
Itemperature.
I I
I 1150A/0137A
t 0
0
IDA POWER AND LIGHT UCIE UNIT No+
1 REGULATORY "PARAMETER S TYPE B VARIAB 97 REV 3 SHEET" Cont'd)
OCTOBER 85 ITEM TAG No.
DESCRIPTION TYPE GORY I EXISTING RE UIRED I
MENT UALIFICATION B5 ITE-1122HA I
IRCS Hot Leg I
B ITemp Loop 1BI I
I IICC IDisplay A I
I I
ITE-1122HB I
I I
I ICC IDisplay B I
I I
I 1
l212'F to I50'F to I Comply I705'F I700 F Note 16 Note 11 Note 16; Note ll VARIABLE I
INSTRUMENT RANGE I
QA I
CATE I
I REQUIRE-I ENVIRONMENTAL SEISMIC UALIFICATION Note 17 Note 23I I*I Note.17 I
I I
I I
I REDUNDANCE TE-1122HB ICC Display B
TE-1122HA ICC Display A POWER DISPLAY LOCATION I
SCHEDULE/
SUPPLY CR TSC EOF JUSTIFICATION I
I SAS I Yesl spDs I
I YeslBelov 350 F I
Ithe (SDC)
I Isystem vill be I
lin operation.
I IThen CET's villi Ibe used for Hotl YeslLeg Temperaturel INote 1
IMA I
INote 1
ISA I
INote 1
IMB I
INote 1
ISB I
Yes ITE-1112CB I
I I ICC IDisplay B I
ITE-1122CA I
I I ICC IDisplay A I
ITE-1122CB ICC Display B
IRCS Cold Legl B
ITemp Loop I 1A1 I
I I
IRCS Cold Legl B
ITemp Loop I 1B1 I
I I
I RCS Cold Legl B
I Temp Loop I
I IB2 I
I I
B6 ITE-1112CA I RCS Cold Legl 8
I ITemp Loop I
I 1A2 I ICC I
IDisplay A I
I I
1 l212'F to I50 F to I705'F I700 F I
I I
I I
1 l212'F to I50'F to l7o5'F l7oo'F Comply Comply 1
l212 F to I50'F to l705 F l7oo'F Comply 1
I 2124F to I50'F to I
Comply I7o5'F l7oo'F I
Note 16 Note 11 Note 16 Note ll Note 16 Note 11 Note 16 Note ll Note 17 Note 17I Note 17 Note 17I Note 17 Note 17I Note 17 Note 17l TE-1112CB I
I I
ICC I Display B
I
I TE-1112CA I
I I
ICC I Display A I
TE-1122CB I
I I
ICC I Display B I
I TE-1122CA I
I I
ICC I Display A I
INote 1
I IMA I
I I
INote 1
I ISA I
I I
INote 1
I IMB I
I I
INote 1
I ISB I
I I
INote 1
I IMA I
I I
INote 1
I ISA I
I I
INote 1
I IMB I
I I
INote 1
I ISB I
I I
I Yes I I
I SAS I Yesl SFDS I
I I
Yes YeslBelov 350oF l(SDC) system I
Ivill be in I
loperation.
Thenl ltemperature I
IMeter TR-3351Y I
Ivillbe used I
Ifor cold leg I
Itemperature.
I I
I Yesl B7 IPT-1107 I
I IPT-1108 ICC Display A ICC IDisplay B I
IPressurizer I
IPressure l(RCS IPressure)
I I
I I
I I
I I
1 lo to 3000 lo to 4000I Comply Ipsia Ipsig Note 16 Note,16 Note 11 Note 11 Note 17 Note 17 Note 17l Note 17l PT-1108 I PT-1107 ICC Display B
ICC Display A Note 1
ISA I
INote 1
ISB I
INote 1
ISA I
INote 1
ISB I
SAS SPDS SAS SPDS Yes Yes Yes I
I I Yesl I
I Yes Existing range I
Iconsidered ac-Iceptable pend-Yesl ing ATWS dis" Iposition.
1150A/0137A
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE B VARI 97 REV 3 SHEETu (Cont'd).
OCTOBER 85 ITEM VARIABLE TAG NO.
DESCRIPTION TYPE CATE-I GORY EXISTING RE UIRED I REQUIRE-I ENVIRONMENTAL UALIFICATION INSTRlJMENT RANGE I
QA I
SEISMIC I
I POWER I DISPLAY LOCATION I
SCHEDULE/
B8 I45 Core I Core Exit IExit Ther-ITemp Imocouples I
I I
I Icc I
I Display A I
I I
Icc I
Display B
B I
3 I32'F to I200'F to I
N/A I2300 F I2300 F I
I I
N/A N/A N/A INote 1
INote 1
ISA I
I INote 1
ISB I
I I
I I
I I
I Yes I Yesl Yes SAS I
SPDS I
I I
Yes I Yesl Yes SAS SPDS B9 I 16 Heated I Coolant IJunction I Inventory IThermo-Icouples I
I Icc IDisplay A I
IRLEV-A I
I Icc IDisplay B I
IRLEV-B I
IBottom of IHot Leg Ito Top lof Vessel l32oF to l2300oF IBottom ofl Comply IHot Leg Ito Top I
lof Vessell Note 16l Note 11 Note 11.
Note 17I Note 17I I Icc I Display B
I (RLEV-B)
I I Icc I Display A I (RLEV-A)
Note 17 8SA and I
8SB INote 1
ISA I
I INote 1
I ISB I
I I
I I
I B10 IICC IDegrees of IDisplay A ISubcooling I TMARHEAD-Al ITMARRCS"A I I TMARCET-A TMARUR-A I
I Icc I
Display B
I ITMARHEAD-BI ITMARRCS-B I
TMARCET-B TMARUR"B 2
I700'F l200 F I Comply ISubcool-ISubcool-ling to ling to 12100 F
I35 F ISuperheat ISuperheatl IRefer to EQ I for Al, A2, IA3, B9 and Icl IRefer to EQ I for Al, A2, IA3, B9 and Icl IRefer to ISeismic Quai-l ification for I
IAli A2>
A3>
IB9 and Cl I
I IRefer to ISeismic Quai-l ification for I
IAl> A2> A3, B9 and Cl N/A INote 1
I Yes I Yesl Yesl IsA I
sAs I
I I
I I
SFDS I
I I
I I
I I
I I
I I
I I
I I
I I
I INote 1
I Yes I Yesl Yes ISB SAS SPDS 1150A/0137A
i I
e
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE B VARIAB 97 REV 3 SHEET" (cont'd)
October 85 VARIABLE INSTRUMENT RANGE gA I
POWER DISPLAY LOCATION I
SCHEDULE/
ITEM TAG NO.
DESCRIPTION TYPE GORY I EXISTING RE HIRED I
MENT UALIFICATION I UALIFICATION I REDUNDANCEI SUPPLYI CR TSC EOPI JUSTIFICATION Bll IPT 1107 I
I IPT-1108 I
IIIcc I Display I Icc IDisplay Ipressurizer I
IPressure 1(RCS IPressure)
A I
I I
B I
I I
1 IO to 3000 IO to 4000I Comply Ipsia Ipsig Note 16 Note 16 Note ll Note ll Note 17 Note 17 I I Note.ill
-I I
I I Note i7l I PT-1108 I
I I PT-1107 I
I I Icc I Display.B I.
I Icc I Display A I
INote 1
I IsA I
I I
INote 1
I IsB I
I I
INote 1 I
IsA I
I I
INote 1
I ISB I
SAS I Yesl YeslSee Item B-7.
I sPDs I
I I
I I
I SAS I Yesl Yesl SPDS Yes Yes B12A LT-07-14A Containment Sump Water ILevel (Nar-Irow Ran e)
ILIS-07-14A g
I I
I I
ILR-07-13/
I 14A I
I
-7 ft to INarrow I Comply 0 ft El IRange I (Sump)
Note 16 Note 11 Note 11 Note 17 Note 17 Note 17 N/A INote 2 I
IsA I
I I
INote 2 I
IsA I
I I
INote 2 I
IsA I
I I
sAs I
SPDS Yes Yes Yesl Yesl B12B ILT-07-13A IContainment I
B I
ILevel (Wide I
I IRange)
ILT-07-13B I
LIS-07-13A LIS"07-13BI LR-07-13/
14A I"1 to 26 IWide I Comply Ift El IRange I
l(Plant I
ISpecific) I Note 16 Note 16 Note 11 Note ll Note ll Note 17 Note 17 Note 17 Note 17
~
I Note 17 I LT-07-13B I
I I LT-07-13A INote 2
ISA I
INote 2 ISB I
LIS-07"13BINote 2 IsA I
LIS-07"13AINote 2 ISB I
INote 2 ISA I
SAS SPDS SAS SPDS Yes Yes Yes I Yesl Yesl I
I I
I I
I Yesl Yesl 1150A/0137A
f 0
k I
II 0
IDA POWER AND LIGHT UCIE UHIT NO.
1 REGULATORY GU "PARAMETER S TYPE B VARIA 97 REV 3 NEET" Cont'd)
OCTOBER 85 VARIABLE ITEM TAG NO.
DESCRIPTION INSTRUMENT RANGE CATE I
GORY I EXISTING RE UIRED QA REQUIRE I ENVIRONMENTAL UALIPICATION SEISMIC UALIFICATION POWER I
REDUNDANCEI SUPPLYI DISPLAY LOCATION I
SCHEDULE/
B13 IPT-07&A I
I IPT-07MB I
I IPI-07<A I
I IPR-07KB/
5B IContainment IPressure I
l(Mid Range)
I 1
IO to 60
,Ipsig lo to IDesign Ipressure I Comply I
I Will Comply Comply Comply Note 16 Note 18 Note 11 Note ll Note 17 Note 19 Note 12 Note 12 I PT-0748
,I I
I PT-07-4A I
I I PR-07-4B/
I 5B I
I PI-07&A INote 1
I IMA I
I I
INote 1
I IMB I
I I
INote 1
I IMA I
I I
INote 1
I IMB SPDS Yes Yes I Yesl Yes SPDS I
I I
I SAS I Yesl Yes I
IDesign Pressure I is 44 psig.
IThe trans" I
Imitter for PT-I l07-43 will be I
I installed I
I in accordance I
Iwith the ache-I Idule on Sec-I ltion V item 5 I
B14A IV-2515 ICVCS Letdownl V-2516 B14B IV-5201 IPressurizer I
ISurge Line Sample V-5204 B14C V-5202 IV-5205 I
I IPressurizer I
Steam Space Sample B14 ICONTAINMENT ISOLATION IVALVE POSITION I
I 1
IClosed IClosed/
lor Open INot I Closed I
I I
1 I Closed I Closed/
I or Open INot Closed 1
IClosed IClosed/
lor Open Not Closed Comply Comply Comply Comply I
I I
I Comply I
I Comply Note 16 Note 16 Note 16 Note 16 Note 16 Note 16 Note 17 Note 17 I I Note 12 I
I I I Note 12 I I Note 12 I
I Note 12 I
I Note 9
Note 9
Note 9
Note 9
Note 9
Note 9
I I
INote 3 I
ISA I
I I
INote 3 I
ISB I
I I
INote 3 I
ISA I
I I
INote 3 I
ISB I
I INote 3 I
ISA I
INote 3 ISB I
I SAS I Yes Yes I
SAS I Yesl Yes I
I SAS I Yes Yes I
I SAS I Yes I Yes IPor manual iso-I lation Valves I see Table l6.2-16 in FSAR.
I These valves lare locked Iclosed under IAdministrative IControl.
No CR lindication or linput to SAS Iprovided.
I Yes l I
I Yesl I
I Yesl Yes Yes Yes 1150A/0137A
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE B VARIAB 97 REV 3 SHEET" (Cont'd)
October 85 VARIABLE INSTRlJMEHT RANGE TAG NO.
DESCRIPTION CATE-I TYPE I
GORY I EXISTING RE UIRED REQUIRE-IENVIRONMENTAL MENT I UALIFICATION SEISMIC I
I POWER UALIFICATION I REDUNDANCEI SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULE/
JUSTIFICATION B14DIMV-15-1 I
I I
B14EI V-2505 ISE-01-1 IPrimary Water Isola-I tion Valve IRCP Con-I trolled IBleedoff B14F I FCV-23-3 FCV-23-4 IFCV-23-5 ISteam Gen-leracor I 8 lowdown I
I FCV-23-6 IFCV-23-7 FCV-23>>9 B14GI B14H B14I V-6741 Nitrogen ISupply to I Sa fe ty In-I jection ITanks B14J V-6554 V-6555 Containment Vent Header MV-18-1 IInstrumenc lAir I Supply I
LCV-07-11AIReaccor ICavity Sump I
Ipump Dis-LCV-07-11B I charge 1
IClosed I or Open I
IClosed/
INot IClosed 1
IClosed IClosed/
lor Open IHot I
IClosed I
I 1
IClosed IClosed/
lor Open INot IClosed I
Closed lor Open 1
IClosed or Open Closed/
INot IClosed I
I I
IClosed/
Not Closed 1
IClosed IClosed/
lor Open INot I
IClosed I
I 1
I Closed IClosed/
lor Open IHoc IClosed Comply Comply Comply Comply Comply Comply Comply Comply Comply I
Comply I
I Comply Comply Comply I Comply I
I I Comply I
I Note 16 Note 12 Note 16 Note 12 Note 8
Note 12 Note 16 Note 12 Note 16 Note 17 Note 16 Note 12 Note 16 Note 17 Noce 11.
Note ll Note 16 Note ll Note 11 Note 11 II I
III I
III I
I.III I
'I II I
III I
Noce Note Note Note Note Note 12 12 12 r
12 12 12 III I
I Note Note ll 12 Note 11 II Note
~ Note 9
Note 9
Note 9
Note' Note 9
Note 9
Note 9
Note 9
Note 9
Note 9
Note 9
Note 9
Note 9 Note 9
Note 9
INote 2 ISB I
I INote 3 ISA I
INote 3 ISB I
INote 3 ISA I
INote 3 ISB I
INote 3 ISA I
INote 3 ISB I
INote 3 ISA I
INote 3 ISA I
INote 2
ISA I
I INote 3 ISA I
INote 3 ISB I
INoce 3
ISB I
'AS Yes SAS Yes SAS Yes SAS Yes SAS Yes I
Yesl I
Yes l I Yesl Yesl I
I I
I I
I I Yesl Yesl I
I I
I I
I I
I I
I Yesl Yesl I
I I
I I
I I Yesl Yesl SAS Yes SAS Yes SAS Yes SAS Yes I
I SAS Yes SAS Yes SAS Yes I Yesl Yes I I
I I
I I
I I
I I
I I Yesl Yes I
I I
I I Yesl Yes I
I I
I I Yesl Yes l I
I I
Yesl Yesl I
I I
I I
I I Yesl Yesl I
I I
I I
I I Yesl Yes I I
I I
I I
I' Yesl Yesl I
I I
I I
I I Yesl Yesl I
I I
I I
I I Yesl Yesl 1150A/0137A
IDA POWER AND LIGHT UCIE UNIT No+
1 REGULATORY "PARAMETER S TYPE B VARIAB 97 REV 3 SHEET" (Cont'd)
October 85 ITEM TAG NO.
VARIABLE DESCRIPTION TYPE INSTRUMENT RANGE CATE-I GORY I EXISTING RE UIRED QA REQUIRE IENVIRONMENTAL UALIFICATION sEIBMIC I
I PowER I
UALIFICATION I REDUNDANCEI SUPPLYI DISPLAY LOCATION CR TSC EOF SCHEDULE/
JUSTIFICATION FCV-26-2 FCV-26-3 FCV-26-4 FCV-26-5 FCV-26-6 B14NIFCV-25-1 FCV-25-2 FCV-25-3 FCV-25-4 IFCV-25-5 I
I IFCV-25-6 I
I B14KIV-5200 I
I IV-5203 I
I IV-6302 I
I B14MIFCV-26-1 IReactor Coolant Sample IReactor B
IDrain Tank I Pump S uction I I
I I
IContainment ISample Isolation Valves I Containment Ipurge Air ISupply and IExhaust 1
IClosed lor Open 1
I Closed lor open 1
IClosed lor Open 1
I Closed I or Open IClosed/
INot IClosed I
I I Closed/
INot IClosed I
I I
IClosed/
INot Closed I Closed/
INot I Closed I:,
I III Comply Comply Comply Comply I Comply Comply I Comply Comply Comply Comply Comply Comply Comply Comply Comply Comply Note 16 Note 16 Note 16 Note 16 Note 16 Note 11 Note 16 Note 11 Note 16 Note 11 Note 11 Note 16.
Note 16 Note 16 Note 16 Note ll II
I III I
II I
III II I
III I
III I
I I
I I
~
II I
III I
I Note 12
= Note 12 Note 12 Note 12 Note 17 Note 12 Note 17 Note 12 Note 17 Note 12 Note 12 Note 12 Note 17 Note 17 Note 12 Note 12 Note 9
'ote 9
Note 9
Note 9
Note 9
Note 9
Note 9
Note 9
Note 9
Note 9
Note 9
Note' Note 9
Note 9
Note 9
Note 9
INote 3 I
IsA I
I I
INote 3 I
Iss I
INote 3 I
IsA I
I I
INote 3 I
Iss I
I I
INote 3 I
Iss I
I I
INote 3 I
ISA I
I I
INote 3 I
lsB I
I I
INote 3 I
ISA I
INote 3 ISB I
INote 3 I
IsA I
I I
INote 3 I
ISA I
I I
INote 3 I
IsA I
I I
INote 1
I IsA I
I I
INote 1
I Iss I
I I
INote 3 I
ISB I
I I
INote 3 I
IBB I
I I
SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes Yes Yes Yesl I
Yes Yes Yes Yesl I
I Yesl I Yesl I
I I Yes I
I I Yesl I
I Yesl I
I Yes l Yes Yesl I
I Yes l I
I I
I I Yes Yesl I
I I
I I Yesl Yesl I Yesl Yesl I
I I
I I
I I Yesl Yesl I
I I
I Yesl Yesl I
I I
I I
I I Yesl Yesl I
I I
I I
I I Yesl Yesl I
I I
I I
I I Yesl Yesl 1150A/0137A
II II' 0
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY G "PARAMETER S TYPE B VARIAB 97 REV 3 SHEET" (Cont'd)
OCTOBER 85 VARIABLE ITEM TAG NO DESCRIPTION INSTRUMENT RANGE CATE-I I EXISTING GORY RE UIRED QA I
REQUIRE-IENVIRONMEHTAL UALIPICATION SEISMIC UALIPICATION I
POWER REDUNDANCEI SUPPLY'I DISPLAY LOCATION CR EOF TSC I
SCHEDULE/
JUSTIFICATION B14PII-FSE-27-1IDome Area IE1 213' I
I I-FSE"27-5IDome Area IE1 190' I
B14Q I-FSE-27-2IPressurizer I
ISample Pointl I
I I
I 1A1 Areal B14RII FSE 27-3IRCP I
I I
I I
"I I I-PSE-27-7 I RCP I
I I
II-FSE-27-4IRCP 1B1 Areal B
lA2 Areal B
I I
I 1B2 Areal B
I I I-FSE-27-6 I RCP I
I 148 I-PSE 11 B14T I-PSE-27-9 I Penetration I
151 I
I I-FSE 110 I
B14UII-FCV 11E I
I I-PCV I 1F I Safety IInjection ITanks Samp-lling System I
I I
I I
B14S I-PSE-27-81Penecration I
B IClosed lor Open I
I IClosed lor Open I
I IClosed lor Open I
I IClosed lor Open I
I IClosed lor Open I
I IClosed I or Open I
II Closed lor Open Closed lor Open IClosed lor Open I
INone Ex-listing in IControl IRoom I
IClosed/
INot IClosed I
IClosed/
INot IClosed II Closed/
IHoc IClosed I
IClosed/
INot IClosed I
I Closed/
INot IClosed I
IClosed/
INot IClosed I
IClosed/
INoc IClosed II Closed/
IHot IClosed IClosed/
INoc I Closed IClosed/
INot IClosed I
I I
I I
I I
I I
I Comply Comply Comply Comply Comply Comply Comply Comply Comply Comply Comply Comply Comply Note 16 Note Note 16 Note 12 Note 16 Note 16 Note 16 Note 16 Note 16 III I
I III I
I I
II I
I II I
Hote Note Note Note 12 12 12 12 Note 11 I
Note 12 Note 11 Note 11 Note ll II I
II I
I II Note Note Notch 12 12 12 Note 8 Note 12 Note 8
Note 12 I I Note 12 I
I Note 9
Note 9
Note 9
Note 9
Note 9 Note 9
Note 9
Note 9
Note 9
. Note 9
Note 9
Note 9
Note 9 INote 2 I
ISA I
I I
I I
INote 2 I
ISB I
I I
I I
INote 2 I
ISA I
I I
I I
INote 2 I
ISA I
I I
I I
INote 2 I
ISB I
I I
I I
INote 2 I
ISA I
I I
I I
INote 2
I ISB I
I I
I I
INote 2
I ISA I
I I
INote 2 I
ISA I
I I
INote 2 I
ISB I
I I
INote 2
I ISB I
I I
INote 3 I
ISA I
I I
INote 3 I
ISB Yes Yes Yes Yes I No I
No I
I I
No I
No I
I I
I I No I Ho I
I I
I I
I I
I No I No I
Note 15 Note 15 Yes Yes I
No I No I
I I
I I
I I No I
No I
Note 15 Note 15 Yes Yes Ycs No I
I I
I I
No I
I I No No No No I No I
I I
I Yes I No I
No No No No I
I I
I I
No I
No I
I I
I I
No I
No Note 15 I
Note 15 I
I Note 15 I
I I
Note 15 I
I I
Note 15 I
I ICR indication I
Iwill be pro-Ivided in laccordance Ivith che sch-ledule provi-ded on sec-tion V item 1
I 1150A/0137A
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY 97 REV 3 "PARAMETER S SHEET" TYPE B VARIABL (Cont'd)
OCTOBER 85 ITEM TAG NO.
B 15 PT-07&A IPT 07 4B I
I I PI-07-4A IPR-07-4B/
5B VARIABLE DESCRIPTION TYPE Containment IPressure l(Mid Range)
I I
I I
I I
I INSTRUMENT RANGE QA CATE-I GORY I EXISTING 1
IO to 60
-5 psig I
I I
to Design pslg
)Pressure
(
I I
I I
I I
Comply Note 16 I
Will Comply Note 18 Comply Note 11 Comply Note 11 I REQUIRE-IENVIRONMENTAL RE UIRED I
MENT UALIPICATION SEISMIC UALIPICATION Note 17 Note 19 Note 12 Note 12 REDUNDANCE I PT-07MB INote 1
I I
IMA I
f PT-07HA (Note 1
I IMB I
I I
I PR-07MB/ INote 1
I I
58 IMA I
I I
I I PI-07&A INote 1
I IMB I
I Yesl YesIRange provided I
I Idoes not cover I
Ithe lower end Yesl Yeslof the required Irange (-5 to I44 psig).
IAdditional Ipressure trans-Imitters cover I-5 to 175 psig l(see Item Cll).
IThe trans-I Imitter for PT-I I07-48 will be I
Ireplaced in I
Iaccordance I
lwith schedule I
I in Section V
I I item 5 POWER DISPLAY LOCATION I SCHEDULE/
SUPPLY I JUSTIFICATION 1150A/0137A
RIDA POWER AND LIGHT UCIE UNIT NO 1
REGULATORY G 97 REV 3 "PARAMETER S SHEET" TYPE C LES OCTOBER 85 VARIABLE ITEM TAG NO.
DESCRIPTION TYPE Cl l45 Core ICore Exit IExit Ther"ITemp lmocouplc I
C 1
l32'F to I2300'F I
l200'F to I Comply I23000F I'
I I
I Note 16 I I IlcC IDisplay A I
I I
I I
I Ice I
IDisplay B
I Note 11 Note 11 INSTRUMENT RANGE QA CATE I
I REQUIRE IENVIRONMENTAL CORY I EXISTING RE UIRED I
MENT UALIFICATION SEISMIC UALIFICATION Note. 17 w*
Note 17 Note 17 I
INote 1
I ISA I
ISB I
I IMinimum I four (4)
Ithermocou" I ples per Ichannel Iper core Iquadrant I
II ICC I Display B
I III ICc I Display A INote 1
I ISA I
I I
I I
INote 1
I ISB I
POWER REDUNDANCEI SUPPLY DISPLAY LOCATION CR TSC EOF Yes I Yesl Yes l sAS I
I I
sPDs I
I I
I I
I I Yesl Yesl Yes SAS SPDS SCHEDULE/
JUSTIFICATION I
I I
C2 INone I
I IRadioac-Itivity Con-Icentration lor Rad Levell I in Circula-Iting Primaryl I coolant I 1/2 Tech I
ISpec I
ILimit to I
I 100 timesl ITech Speci
- ILimit, INo instrument-I lation systems I
I available.
I IFuel clouding I
lfailure de-I I tected by PASSI ISee Item E17A I
I I
I 1150A/0137A
IDA POWER AND LIGHT UCIE UNIT NO>
1 REGULATORY 97 REV 3 "PARAMETER S SHEET>>
TYPE C VARIAB (Cont>d)
October 85 ITEM VARIABLE INSTRUMENT RANGE QA CATE-I I REQUIRE-IENVIRONMENTAL TAG NO.
DESCRIPTION TYPE I
GORY I EXISTING RE UIRED I
MENT UALIFICATION SEISMIC I
I POWER I DISPLAY LOCATION SCHEDULE/
C3 IPC-I-131 I
I IPC-XE-133 I
I IPC-CO-60 I
I IPC-CS-134 C4 I PT-1107 I
I IPT-1108 I
I I ICC IDisplay A I
I lcC IDisplay B
IAnalysis of I
IPrimary I Coolant l(Gamma ISpectrum)
I IPressurizer I
IPressure I(RCS IPressure) 3 ll to I 10 I uCi/ml I 10 uci/mll I to 10 I Ci/ml lor TID" I14844 Isource ITerm in I Coolant I Volume 1
IO to 3000 IO to 4000I Ipsia Ipsis N/A Comply N/A Note 16 Note 16 Note 11>23ll I
I Note 11,23ll N/A Note 17 Note 17 Note 23I Note 23l N/A PT-1108 I PT-1107 I
I I ICC I Display I
I ICC I Display I Yesl Yesl I
I I
I I
I Yesl Yesl I
I I
I I
I I Yesl Yesl I
I I
I I
I I Yesl Yesl I
I INote 2AI INS I
I INote 2AI INs I
I I
INote 2AI INs I
I I
INS INs I
INote 1
ISA I
INote 1
I ISB I
I I
SAS Yes SAS SPDS SAS I Yesl Yesl SPDS I
I INote 1
I Yes B ISA I
I I
INote 1
I A ISB Yes Yes See Item B-7 I 1150A/0137A
0 d'
r 0
I
RIDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE C VARI 97 REV 3 SHEET" (Cont'd)
OCTOBER 85 VARIABLE INSTRUMENT RANGE I
QA I
CATE-I I REQUIRE-IENVIRONMENTAL I SEISMIC I
I POWER DISPLAY LOCATION I
SCHEDULE/
C5 PT-07<A IPT"07<8 I
I I PI-07<A I
I IPR-07KB/
5B IContainment IPressure l(Mid Range)
I I
I I
I I
I I
ITEM TAG NO DESCRIPTION 1
IO to 60 I-5 psig I Comply Ipsig Ito Designl IPressure I
I I
I I
I I
I I
I I
I I
I, I
Will Comply Comply Comply GORY I EXISTING IRE HIRED I
MENT UALIFICATION Note 16 Note 18I Note 11 Note 11 Note 17 Note 19I Note 12 Note 12 I PT-07KB I
I I PT-07~A I
I I PR-07MB/
I 5B I
I PI-07&A INote 1
IMA I
INote 1
IMB I
INote 1
IMA I
INote 1
IMB UALIPICATION I REDUNDANCEI SUPPLYI SAS SPDS SAS SPDS Yes Yes I
Yesl YeslRange provided I
I Idoes not cover I
I Ithe lower end I Yesl Yeslof the required Irange ("5 to l44 psig).
IAdditional Ipressure trans-lmitters covers l-5 to 175 psig l(see Item Cll).
ITransmit ter I
IPT-07-48 will I Ibe replaced I
lin accordance I
Iwith schedule I
I in Section V
I litem 5.
I C6A ILT 07-14A I
I ILIS-07-14A I
I ILR-07-13/
14A IContainment ISump Water ILevel (Nar-Irow Range)
I I
I I
I 2
I "7 to 0 ftlNarrow I Comply IE1 IRange l(sump)
Note 16 Note 11" Note 11 Note 17 Note 17 Note 17 N/A INote 2 I
IsA I
I I
INote 2 ISA I
I I
INote 2 I
ISA I
SAS I
SPDS Yes Yes Yesl Yes l I
C6B I LT-07"13A I Containment I
ILevel I
I (Wide Range) I I
I ILT-07-138 I
I I
I LIS-07-13AI I
I I LIS-07-13B I I
I LR-07-13/
I 14A I
I I-1 to 26 IWide I Comply Ift El IRange I (Plant I
ISpecific) I Note 16 Note 16 Note ll Note 11 Note 11 Note 17 Note 17.
Note 17 Note 17 Note 17 I LT-07-13B INote ISA I
I I LT"07-13A INote I
ISB I
I I LIS-07-13B INote I
ISA I
I I LIS-07"13AINote ISB I
INote ISA I
2 I
I I
2 I
I I
2 I
I I
2 I
I I
SAS SPDS SAS SPDS Yes Yes Yes I Yesl Yesl I
I I
I Yesl Yesl 1150A/0137A
1 t+
eN
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY G "PARAMETER S TYPE C VARIA 97 REV 3 SHEET" (Cont'd)
October 85 ITEM TAG NO.
VARIABLE INSTRUMENT RANGE QA CATE I
I REQUIRE-I ENVIRONMENTAL DESCRIPTION TYPE GORY I EXISTING RE UIRED I
MENT UALIPICATION SEISMIC UALIFICATION REDUNDANCE POWER I
SUPPLYI DISPLAY LOCATION SCHEDULE/
C7 IRE-26-58 I
I I RE-26-5 9 I
I IRIS"26-58 I
I IRIS"26-59 RR-26-58 IRR-26-59 IContainment I
IArea IRadiation I
I I
I I
I I
C 3
I 1 R/hr to Il R/hr tol N/A I 10 R/hr I 10 R/hr I
N/A N/A N/A INote 2 I
ISA I
I I
INote 2 ISB I
INote 2
ISA I
INote 2 ISB I
INote 2 ISA I
INote 2 ISB I
SAS SPDS SAS SPDS Yes Yes Yes Yes I Yesl I
I I
I I Yesl I
I Yesl I
I Yesl I
C8 IRE-26-35 I
I IRIS-26-35 I
I I RR-26-1 D IEffluent IRadioactiv-I ity - Noble I
IGas Efflu" lent from ICondenser lAir Removal I
System Exhaust I101 to I10"6 3
I 10 CPM I uCi/cc tol Iwhich is I10 2 lequivalentluCi/cc lto yx I10 o to l2x 102 I uCi/cc N/A N/A N/A N/A INote 2AI INs I
I I
INote 2AI INS I
I I
INote 2AI INS SAS I
SPDS Yes Yes Yes l Yesl I
Ipressurirer I
IPressure I(RCS I
IPressure)
C9 IPT-1107 I
I I
IPT-1108 I
I I ICC IDisplay A I
I I
I ICC I
IDisplay B I
I I
I I
ps1a I psig I
I I
I C
1 IO to 3000 IO to 4000I Comply Note 16 Note 16 Note 11 Note 11 Note 17 I PT-1108 I
I I
Note 17 I PT-1107 I
I Note 17 I
I ICC I Display I
Note 17 I
I ICC I Display I
I INote ISA I
I INote ISB I
INote B ISA I
INote A ISB I
I SAS SPDS SAS SPDS Yes Yes Yesl YeslSee Item B-7 I
I I
I I Yesl Yesl 1150A/0137A
4
IDA POWER AND LIGHT UCIE UNIT NO+
1 REGULATORY 97 REV 3 "PARAMETER S SHEET" TYPE C VARIA Cont'd)
OCTOBER 85 VARIABLE I
INSTRUMENT RANCE QA ITEM TAG NO.
DESCRIPTION CATE-I GORY I EXISTING RE UIRED I
REQUIRE IENVIRONMENTAL MENT UALIPICATION SEISMIC UALIPICATION I
I POWER I
REDUNDANCEI SUPPLYI DISPLAY LOCATION I
SCHEDULE/
C10 Hydrogen Containment Sara lin IH dro en p
8 y
g
& AnalyzerlConcentra" Cubicle SAItion I
I Hydrogen '
I Sampling I
I & Analyzer I I Cubicle SB I I
IHydrogen IAnalyzer I Ind IRecording ICubicle SAI II Hydrogen IAnalyzer IInd IRecording I
I Cubicle SB I I
I 1
0 to 10X l(Capable lof Oper" lating Ifrom -5 Ipsig to l44 psig) 0 to 10 IVol - X l(Capable I
lof oper-lating I from "5 Ipsig to Imaximum Idesign Ipressure)l Comply Note 11 Note 11 Note 11 Note 11 Note 12 Note 12 Note 12 Note 12 Hydrogen ISampling I& Analyzer ICubicle SB I
IHydrogen ISampling I& Analyzer I Cubicle SA I
IHydrogen IAnalyzer IInd &
IRecording I Cubicle SB I
IHydrogen IAnalyzer I Ind &
IRecording I Cubicle SA Note 2
ISA I
I I
INote 2
I IBB I
I I
I I
I I
INote 2
I ISA I
I I
I I Note 2 I
ISB I
I I
SAS I
SPDS Yesl Yesl Yes Yes SAS Yes Yes Deszgn Pressure SPDS lis 44 psig.
Cll I PT"07-8A I Containment I
IPressure I
l(Wide Range)I IPT-07-SB IPIS"07-8A I
I I
I IPIS-07"8B I
I I
IPR-07-BA I
I
-5 to 175 I-5 psig psig Ito 4 Itimes IDesign Ipressure I'omply I
I I Comply I
I I Comply I
I I Comply I
I I Comply I
I INote 11 Irefer to the IJustification I
Note 11 Note 11 Note 11 Note 17 PT-07-8B I PT-07-SA I
I I PIS-07-BB I
I-Note 17 Note 17 Note 17 I
I I
I I
Note 17 I PIS-07-8A Note 2
ISA I
INote 2
ISB I
INote 2 ISA I
INote 2 ISB I
INote 2 ISA I
SAS SPDS SAS SPDS Yes Yes Yes I Yes I
I I Yesl lis 44 psig.
ITransmitters Yesl are qualified Iper IEEE l323-1971 and I for thermal I aging by I analysis.
Yes Deszgn Pressure 1150A/0137A
0
IDA POWER AND LIGHT UCIE UHIT NO.
1 REGULATORY "PARAMETER S TYPE C VARIA 97 REV 3 SHEET" (Conc'd)
October 85 I
VARIABLE I
INSTRUMENT RANGE I
QA ITEM TAG NO.
DESCRIPTION GORY I EXISTING RE HIRED I REQUIRE-IENVIRONMENTAL MENT UALIPICATION SEISMIC UALIFICATION REDUNDANCE POWER I DISPLAY LOCATION SCHEDULE/
C12 IRSC-26-L I
I I CT-2 I
I I
IContainment 0
IEffluent IRadioactiv" I ity - Noble I
IGases frosL I Identified I
IRelease IPoincs I
I 2
18 x 10 I10 luci/cc to luci/cc l9 x 10-2 I co 10-2 luCi/cc luCi/cc I
Is I
I N/A Note 11 Note 11 N/A N/A INote 2AI SAS I Yesl Yesl INS I
SPDS I
I I
I INote 2AI Yes IHS I
C13 IRSC-26-1L RSC-26-1M IRSC-26-2L RSC-26-2M IRSC-26-3L I
I IRSC-26-3M I
I IRSC-26-4L RSC-26-4M I
ICT-2 I
I IEffluent C
IRadioactiv" I
licy " Noble I
IGases (fron I
Ibuildings I
lor areas IMhere pene-Itrations land hatches I
lare located,l le.g.,
sec-I londary con-I Itainmenc andi lauxiliary Ibuildings land fuel Ihandling Ibuildings I
I that are in I
Idirecc con-I Itact Mith I
lpriuary con-I Icainnenc I
2 l8 x 10-8 I10-6 luCi/cc to luCi/cc tol l4 x 10 I10 luCi/cc luCi/cc H/A Note 11 Note 11 Hote 11" Note 11 Note 11 Noce ll:
Note 11 Note 11 Note 11 N/A N/A INote 2AI INS I
I I
INote 2AI INS I
INote 2A INS I
INote 2AI INs I
I I
IHote 2AI INS I
INote 2A IHS Note 2A NS INote 2AI IHS I
INote 2A INS I
Yesl I
I Yesl Yes SAS SPDS Yes Yes SAS SPDS SAS I
SPDS Yes Yesl Yesl I
I I
I Yesl Yesl I
I Yesl Yes I
V
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY G 97 REV 3 "PARAMETER S SHEET" TYPE D V LES October 85 VARIABLE INSTRUMENT RANGE QA CATE-I I REQUIRE-I ENVIRONMENTAL TYPE GORY I EXISTING RE UIRED I
MENT I UALIFICATION ITEM TAG NO.
DESCRIPTION SEISMIC I
I POWER I
UALIFICATION I REDUNDANCE I SUPPLYI DISPLAY LOCATION I SCHEDULE/
Dl FT-3306 IFIC-3306 I
I IFR-3306 IShutdown ICooling IFlow to I RCS 2
IO to 8000 IO to 110XI Comply Igpm IDesign IFlow Note 11 Note 11 Note 11 Note 12 Note 12 Note 12 N/A INote 2
I IsA I
I I
INote 2 I
IsA I
I I
INote 2 I
ISA I
I Yesl YeslDesign Flow is I5920 gpm (Refer Ito Item D22 for Icontainment Ispray flow) ~
D2 ITE-3303X I
I ITI-3303X I
I ITR-3303X I
I ITE-3303Y I
I ITI-3303Y TR-3303Y IShutdown D
ICool HX 1A I
I Outlet Temp 2
IO'F to l400'F l40'F to 1350 F
IShutdown ICool HX 1B IOutlet Temp D
2 IO F to I40'F to 1400'F l350'F N/A N/A Note 16 Note 11 Note 11 Note 16 Note 11 Note 11 N/A N/A N/A N/A INote 2AI I IA
-I I
I INote 2AI I IA I
I I
INote 2AI I IA I
I I
INote 2AI I IB I
I I
INote 2AI I IB I
I I
INote 2AI I IB I
sAs I
SPDS Yes Yes Yesl Yesl Yesl Yesl D3 I LT-3311 LIA 3311 LT-3321 LIA-3321 LT-3331 LIA-3331 ISI Tank 1A1 I
D ILevel (Ac-I cumulator)
I I
I I
I ISI Tank 1A2 I
D ILevel (Ac-I cumulator)
I I
I ISI Tank 1B1 I
D ILevel (Ac-cumulator)
N/A N/A 2
l20 to 602 10 to 90XI N/A IVolume I Volume (approx) 2 l20 to 60X l10 to 90XI I Volume I Volume l(approx)
I I
I I I 2
I20 to 602 I10 to 90XI I Volume I Volume I
l(approx)
Note 16 I Note ll Note 16I Note ll Note 16l Note ll N/A N/A N/A N/A N/A N/A INote 2AI INS I
I I
INote 2AI INs I
I I
INote 2AI INs I
I I
INote 2AI INs I
I I
INote 2AI INs I
I INote 2AI I
I I
I sAs I
Yes sAs I
Yes SAS Yes Yesl Yesl Yes Yes Yesl Yesl 1150A/0137A
I M
0
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE D VARIAB 97 REV 3 SllEET" (Con't 'd)
OCTOBER 85 ITEM TAG NO.
VARIABLE DESCRIPTION TYPE INSTRUMENT RANGE QA I
CATE-I I REQUIRE-IENVIRONMENTAL I SEISMIC I EXISTING RE HIRED I
MENT UALIFICATION UALIPICATION GORY I
POWER REDUNDANCEI SUPPLYI DISPLAY LOCATION I
SCHEDULE/
LT-3341 ILIA-3341 ISI Tank 1B2 I
D ILevel (Ac" I cumulator)
I 2
l20 to 60X I10 to 90XI N/A I Volume I Volume I(approx)
Note 16I Note ll N/A INote 2AI INs I
I I
INote 2AI INS SAS Yes I Yesl Yesl IPT-3311 I
I IPIA-3311 PT-3321 IPIA-3321 PT-3331 IPIA-3331 PT-3341 IPIA-3341 I
I I
D4 IV-3614 I
I IV-3624 I
I ISI Tank 1A1 I
IPressure l(Accumula-I tor)
I I
ISI Tank 1A2 IPressure l(Accumula-I tor)
I I
ISI Tank 181 I
IPressure l(Accumula-I tor)
I I
ISI Tank 1B2 I
IPressure I (Accumula-I tor)
ISI Tank 1A2 I
D IDisch Valve I
I I
ISI Tank 1A1 I
D IDisch Valve I
I I
I I
I I
750 I
N/A IO to 300 IO to Ipsig Ipsig I
I I
I IO to 300 IO to lpsig Ipsig I
I I
I I
I I
I IO to 300 IO to Ipsig Ipsig 750 I
N/A 750 I
N/A 750 I
N/A IClosed lor Open I
I Closed lor Open I
IClosed I Comply I or Open I
I I
IClosed I Comply lor Open I
I I
Note 16I Note 11 Note 16I Note.11 Note 16I Note 11 Note 16l Note 11 Note 8
Note 8
N/A N/A N/A N/A Note 12 Note 12 N/A N/A N/A N/A N/A N/A INote 2AI INS I
I I
INote 2AI INS I
I I
INote 2AI INs I
I I
INote 2AI INs I
I I
INote 2AI INs I
I INote 2AI INs I
I INote 2AI INs I
I INote 2AI INS I
INote 2 I
IsB I
I I
INote 2
I ISA I
I I
SAS Yes SAS Yes SAS Yes SAS Yes I Yesl Yesl Yesl Yes l I Yesl Yesl I
I Yesl Yesl Yes l I
Yes SAS I Yesl Yes I
I I Yes I
I
- 21 1150A/0137A
RIDA POWER AND LIGHT LUCIE UNIT NO.
1 REGULATORY
.97 REV 3 "PARAMETER SHEET" TYPE D VARIA (Cont'd)
OCTOBE 985 ITEM TAG NO.
VARIABLE I
INSTRUHENT RANGE CATE I
DESCRIPTION ITYPE GORY I EXISTINC RE UIRED QA I
I I
REqUIRE-I ENVIRONMENTAL I SEISMIC I
I POWER I
MENT UALIFICATION IQUALIFICATION I REDUNDANCEI SUPPLYI DISPLAY LOCATION CR TSC EOF SCHEDULE/
JUSTIFICATION V-3634 IV-3644 I
I SI Tank 1B1 I
D IDisch Valve I
I I
ISI Tank 1B2 I
D IDisch Valve I
2 I Closed lor Open I
2 I Closed lor Open I
IClosed I or Open I
I Closed lor Open I
Comply Comply Note 8
Note 8
Note 12 Note 12 N/A N/A INote 2
I IsB I
I I
INote 2
I ISA I
I I
I I
I I Yesl Yesl I
I I
I I
I D5 FT-2212 Boric Acid I
I Charging I
IFlov IFIA-2212 D
2 0 to 150 0 to 110X Igpm IDesign I Flow I
N/A Note 16 Note ll N A N A Note 2A INS I
I I
INote 2AI INS I
I I
SAS SPDS Yes Yes Yes Design lov xs I 132 gpm.
D6 IFT-3311 I
I IFT-3313 I
I IFI-3311 I
I IFR-3313 I
I IFT-3321 FT-3323 I F 1-3321 I
I IFR-3323 I
I IFT"3331 I
I IFT-3333 I
I IF I-3331 I
I IHPSI Flov ILoop lA2 IHPSI Flov I Loop lA1 IHPSI Flow I Loop 181 H/A I Comply N/A Comply 2
0 to 110XI Igpm IDesign I
IO to 300 I
IFlow N/A Comply N/A Comply IO to 300 0 to 110XI Igpm IDesign IFlov I
N/A Comply N/A 2
IO to 300 IO to llOZI Igpm IDesign I
I IFlow Note 11 N/A Note 11 Note 12 Note 11 N/A Note 11 Note 12 Note 11 N/A Note 11 Note 12 Note 11 N/A Note 11 Note 12 Note 11 N/A Note 11 Note 12 Note ll I
N/A I
I N/A N/A N/A INote 2AI INS I
I INote 2 I
IsB I
I I
INote 2AI INs I
I I
INote 2 I
IsB I
I I
INote 2AI INs I
I I
INote 2
I ISA I
I I
INote 2AI INS I
I I
INote 2
I ISA I
I I
INote 2AI INS I
I I
INote 2 IsB I
I I
INote 2AI INs I
I I
SAS SAS Yes Yes SAS SAS Yes Yes SAS SAS Yes I Yesl I
I I
I I Yesl I
I I Yesl I
I I
I I Yesl I
I Yesl I
I I
I I Yesl I
II I
I Yes Design flov I
I is 320 gpm I
I Ex is ting I
Yeslrange vill be I
Ichanged 0 to I
Ito 400 gpm in I
laccordance I
Ivith the sch-I ledule in Sec-Ition V item 2 I
I I
Yesl I
I Yes l Yes l I
I Yesl 1150A/0137A
f
'[
I
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY 97 REV 3 "PARAMETER S SHEET,"
TYPE D VARI Cont'd)
OCTOBER 85 VARIABLE ITEM TAG NO.
DESCRIPTION INSTRUMENT RANGE QA CATE-I I REqUIRE-GORY EXISTING RE UIRED I
MENT ENVIRONMENTAL UALIFICATION SEISMIC UALIPICATION REDUNDANCE POWER SUPPLY DISPLAY LOCATION R
TS SCHEDULE/
JUSTIPICATION IFR-3333 I
I IFT-3341 I
I IFT-3343 I
I IFI-3341 I
I IFR-3343 IHPSI Plov ILoop 1B2 I Comply I
I I
IO to 300 10 to 110XI N/A Igpm IDesign I
I Plow I
I I Comply N/A I Comply Note 11 Note ll Note 11 Note 11 Note 11.
Note 12 N/A Note 12 N/A Note 12 N/A INote 2
I ISB I
I I
INote 2AI INs I
I I
INote 2
ISA I
I I
INote 2AI INS I
I I
INote 2 ISA I
I Yes SAS SAS Yes Yes I
I I
I Yesl I
I I
I I Yesl I
I I
I I
I I
I YeslDesign flov lis 320 gpm.
IExis ting Yesl range will be I
lchanged 0 to 1400 gpm in laccordance Iwith the sch-ledule in Sec-Ition V item 2 I
I D7 IPT-3312 I
I IFI-3312 I
I IFT-3322 I
I IFI-3322 I
I IFT-3332 I
I IPI-3332 I
I IFT-3342 I
FI-3342 ILPSI Flov ILoop 1A2 ILPSI Flov ILoop 1A1 I
I I
I ILPSI Plow ILoop 1B1 I
I I
I ILPSI Flow ILoop 1B2 2
IO to 2000 IO to 110XI Igpm IDesign IP low 2
IO to 2000 IO to 110XI Igpm IDesign I
I Flow I Flow I
I I
I 2
IO to 2000 IO to 110X Igpm IDesign IFlow 2
IO to 2000 IO to 110XI Igpm IDesign N/A N/A N/A N/A Note 11 Note 11 Note ll Note 11 Note ll Note 11 Note 11'ote 11 N/A N/A N/A N/A N/A N/A N/A N/A INote 2AI INS I
I I
INote 2AI INs I
I I
INote 2AI INS I
I I
INote 2AI INS I
I I
INote 2AI INs I
I I
INote 2AI INS I
I I
INote 2AI INs I
I I
INote 2AI INs I
I I
SAS Yes SAS Yes SAS Yes SAS Yes Yesl YeslDesrgn flow xs l1763 gpm per lloop.
I Yesl Yesl I Yesl Yesl Yes l Yes l I
I I
I I
I I 1150A/0137A
I I
t I
C"
IDA POWER AND LIGHT s
UCIE UNIT NO.
1 REGULATORY 97 REV 3 "PARAMETER S SHEET" TYPE D VARIA (Cont'd)
October 85 ITEM TAG NO.
VARIABLE REQUIRE-I ENVIRONMENTAL DESCRIPTION TYPE GORY I EXISTING RE UIRED I
MENT UALIPICATION SEISMIC UALIFICATION REDUNDANCE POWER I
SUPPLYI DISPLAY LOCATION I SCHEDULE/
D8 ILT-07-2A I
I ILT"07-2B I
I ILT-07-2C I
I ILT-07-2D I
I ILIS-07-2A I
I ILIS"07-2B I
I I LIS-07-2C I
I ILIS"07-2D I
I ILR-07-2A IRefueling IWater IStorage ITank Level I
2 I
I 0 to 50 ft I Top to I
IBottom I
I Comply Note 11 Note 11 Note 11 Note 11 Note 11 Note 11 Note 11 Note ll Note 11 Note 12 Note 12 Note 12 Note 12 Note.12 Note 12 Note 12 Note 12 Note 12 N/A INote 1
IMA I
INote 1
1MB I
INote 1
IMC I
INote 1
IMD I
!Note 1
IMA I
(Note 1
1MB I
INote 1
IMC I
I I
INote 1
I lMD I
I I
)Note 1
I IMA SAS SPDS SAS SPDS SAS SAS Yes Yes Yes Yes Yes I Yesl I
I I
I I Yesl I
I I
I I Yesl I
I I
I I Yesl I
YeslThe range pro-Ivided covers Ithe useful vol-Yeslume of the tank l(2.62 to 1002 lof total tank Yesl height).
I I
Yesl D9 IAM-101 IAM-105 AM-109 AM-113 IReactor D
ICoolant Pum I
P I 1A1 Status I
I I
IReactor I
D ICoolant Pump l I 1B1 Status I
I I
IReactor I
D (Coolant Pumpl I 1A2 Status I
I I
IReactor I
D ICoolant Pumpl I IB2 Status I
I 3
IO to 800A IMotor I
ICurrent I
I I
I 3
IO to 800A )Motor I
!Current I
I I
I 3
lO to 800A IMotor
!Current I
I 3
lO to 800A IMotor I
ICurrent I
I I
I N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A NS NS NS Yes SAS Yes SAS Yes SAS Yes SAS Yesl Yesl I
I I
I I
I Yesl Yesl I
I I
Yes( Yes)
I I
I I
I I
Yes! Yesl I
I I 1150A/0137A
~
~
qIDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE D VARI 97 REV 3 SHEET" (Cont'd)
OCTOBER 85 ITEM TAG NO.
D10 IFT-1402 I
FT-1404 PORV 2
IO to 100X IClosed/
I Comply I (Closed INot I to Open)
IClosed Note 16 Note 16 IIFI-1402 I
I IFI-1404 I
FT-1200 FT-1201 I
I I
I ISafety IRelief IValves I
I IO to 100X IClosed/
I 2
Comply I (Closed I Not I to Open)
IClosed Note ll Note 11 Note 16 Note 16 FT-1202 Note 16 IFI-1200 I
IIFI-1201 I
I IFI-1202 Note 11 Note 11 Note ll VARIABLE I REQUIRE-IENVIRONMEHTAL DESCRIPTION TYPE GORY I EXISTING RE UIRED I
MENT UALIFICATION SEISMIC UALIFICATION Note 17 Note 17 Note 17 Note 17.
Note 17 Note 17 Note 17 Note 17 Note 17 Note 17 REDUNDANCE N/A N/A POWER I
SUPPLYI INote 2AI Izs I
I I
INote 2AI Izs I
I I
INote 2AI I IB
'I I
I INote 2AI Izs I
I I
INote 2AI Izs I
I I
INote 2AI Izs I
I I
INote 2AI Izs I
I I
INote 2AI Izs I
I I
INote 2AI I zs I
I I
INote 2AI IIB SAS SPDS SAS SPDS Yes Yes SAS SPDS SAS SPDS SAS SPDS Yes Yes Yes I Yesl I
I I
I I Yesl I
I I Yesl I
I I Yes I
I I Yesl I
II I
YesITo achieve a
Ihigh quality Imeasurement Yes l qualified lequipment was lused for this Inonsafety Imeasurement.
I I
I I
Yesl I
I Yes l I
I Yesl DISPLAY LOCATION I SCHEDULE/
Dll LT-1110X ILT-1110Y I
I I LIC-1110X LIC-1110Y ILR-1110 I
I I
Pressurizer ILevel l(Harrow IRange)
I I
I I
I I
1 175" to I 349" WC I
I I
I IO to 100X I
Top to Bottom Comply I Comply I
I I Comply I
I I Comply I
I I Comply Note 16 Note 16 I
I Note 11 I
I I
Note 11 I
I I
Note 11 I
I I
Note 17 Note 17 Note 12 Note 12 Note 12 LT-1110Y I LT-1110X I
I I LIC-1110Y I
I I LIC-1110X Note 2AI I IA I
I INote 2AI Izs I
I INote 2AI IIA I
I I
INote 2AI Izs I
I INote 2AI I IA I
I I
I SAS SPDS SAS SPDS Yes Yes Yes I Yesl YeslNote 26 I
I I
I I
I I Yesl Yesl 1150A/0137A
t
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY 97 REV 3 "PARAMETER S SHEET" TYPE D VAR (Cont'd)
OCTOBER 85 ITEM I
INSTRUMENT RANGE QA CATE-I I
REQUIRE-IENVIRONMENTAL TAG NO.
DESCRIPTION TYPE GORY I EXISTING RE UIRED MENT UALIFICATION SEISMIC UALIFICATION REDUNDANCE POWER SUPPLY DISPLAY LOCATION CR TSC EO SCHEDULE/
JUSTIFICATION D12 AM-943 IPressurizer I
D I Heater AW944 IStatus 2
IO to 150A IElectric I
ICurrent N/A Note 11 Note 11 N/A N/A NS NS SAS SAS Yesl YeslControl Room I
I I indication of I
I Yesl YeslPressurizer Iheater KW is lavailable.
D13 I LT-1116 IQuench Tank Level LIA-1116 3
I 0 to 100Z ITop to IBottom N/A N/A N/A N/A INote 2AI SAS INS I
I I
INote 2AI Yes INS I Yesl YeslThe range rs I
19.5Z to 90.5Z I
I of top to I -" Ibottom of the quench tank.
D14 ITE-1116 IQuench I
ITank I
ITemperature I
ITIA-1116 3
IOF to I350'F l50 F to I750 F N/A N/A N/A I Note 2AI SAS INS I
I I
INote 2AI Yes INS Yesl YeslExisting range I is acceptable Ibased on I rupture disc I setting for Isaturated steam Iconditions.
Quench Tank Pressure D15 IPT-1116 I
I I
IPIA-1116 3
IO to 100 IO to Ipsig IDesign IPressure I
N/A N/A N/A N/A INote 2AI SAS I
INS I
SPDS I
I INote 2AI Yes INS I
Yesl YeslDesign pressure lis 100 psig.
LT-9013B I LT-90130 Range)
LT-9013D D16 ILT-9013A I
SG 1A1.
I I Level I
(Narrov 1
IO to 132 I Inches lwc IFrom Tubel Comply ISheet to I
ISepara-I Itors I Comply I
I I Comply Comply Note 16:
Note 16 Note 16 Note 16
.Note'17 Note 17 Note 17 Note 17 I LT-9013D I
I I LT-9013C I
I I LT-9013B I LT-9013A I
INote 1
I IMA I
I I
INote 1
I MB SAS I Yesl YeslNote 24 SPDs I
I I
I I
SPDS I
I I
-26" 1150A/0137A
t
/
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY G "PARAMETER S TYPE D VARIABL 97 REV 3 SHEET" (Cont'a)
OCTOBER 85 VARIABLE INSTRUMENT RANCE TAG NO.
DESCRIPTION cATE-I TYPE GORY I EXISTING RE UIRED REQUIRE IENVIRONMENTAL I SEISMIC MENT I UALIFICATION I UALIFICATION I
POWER REDUNDANCEI SUPPLYI DISPLAY LOCATION I
SCHEDULE/
EOFI JUSTIFICATION CR Tsc I LIC-9013A I
I I LIC-9013B I
I I LIC"9 01 3C I
I ILIC-9013D I
I I LR-9013A I
I ILT-9023A I
I I LT-90238 I
I ILT-9023C I
I I LT-9023D I
I ILIC-9023A I
I I LIC-9023B I
I ILIC-9023C I
I I LIC-9023D I
I ILR-9023A I
I I
SG 1A1 I Level (Narrow I Range)
SG 1B1 I Level I (Narrow Range)
Comply Comply II.
I Comply I
I Comp ly Comply IO to 132 I
1 Plant llnches Ispecific Comply Comply Comply Comply IO to 1002 I
I I
I I
I Comply Comply Comply Comply Comply I
1 IO to 1002 IFrom Tubel ISheet to ISepara-Itors Note 11 Note 11 Note 11 Note 11 Note ll Note 16 Note 16 Note 16 Note 16 Note 11 Note ll Note 11 Note 11.
Note 11 Note 12 Note 12 Note 12 Note 12 Note 12 Note 17 Note 17 Note 17 Note 17 Note 12 Note" 12 Note 12 Note 12 Note 12 LIC-9013D LIC-90130 LIC-9013B LIC-9013A LT-9023D LT-9023C LT-9023B LT-9023A LIC-9023D LIC-9023C LIC-9023B LIC-9023A I
INote 1
I IMA I
I I
INote 1
I IMB I
I I
INote 1
I IMc I
I I
INote 1
I I MD I
I I
INote 1
I IMA I
I I
INote 1
I IMA I
I I
INote 1
I IMB I
I I
INote 1
I IMc I
I I
INote 1
I IMD I
I I
INote 1
I IMA I
I
=
I INote 1
I IMB I
INote 1
IMC I
INote 1
I IMD I
I I
INote 1
I IMA I
I I
Yes Yes I
I INote 24 I
I Yes Yes Yes Yes Yes Yes Yes SAS I Yesl Yesl sPDs I
I I
I I
I I
I I
I I
I I
I I
I I
I Yes I I I I
I I
I I 1150A/0137A
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY 97 REV 3 "PARAMETER S SHEET" TYPE D VARIAB (Cont'd)
October 85 VARIABLE INSTRUMENT RANCE ITEM D17 IPT-8013A I
I IPT-80138 I
I IPT-8013C I
I I PT"8013D I
I I PI-8013A I
I IPI-8013B I
I I P I-801 3C I
I IPI-8013D I
I IPR-8013A I
I IPT-8023A I
I IPT-8023B I
I IPT-8023C I
I IPT-8023D I
I IPI-8023A I
I IPI-8023B I
ISG 1A IPressure I
I ISO 1B (pressure TAG NO.
DESCRIPTION CATE I
REQUIRE-IENVIRONMENTAL MENT Comply Comply Comply Comply UALIFICATION Note 16'ote 16 Note 16 Note 16 Comply Note ll Comply Note 11 Comply Note 11 Comply Note 11 Comply Note 11 2
I I
0 to 1200 IFrom ATM psia IPressure Comply Note 16 Ito 20X labove thel Comply Note 16 ILowest Igafety I Valve ISetting Comply Comply Note 16 Note 16 Comply Note 11'omply Note 11 TYPE I
GORY I EXISTING RE UIRED 2
lO to 1200 IFrom ATM I Ipsia Ipressure I
I co 20X labove thol ILowest (Safety IValve ISetting SEISMIC UALIFICATION Note 17 Note 17 Note 17 Note 17 Note 12 Note 12 Note 12 Note 12 Note 12 Note 17 Note 17 Note 17 Note 17
'Note.12 Note 12 N/A N/A INote 1
I IMA I
I I
INote 1
I 1MB I
I I
INote 1
I IMC I
I I
)Note 1
IMD I
I I
INote 1
I IMA I
I I
INote 1
I IMB I
I I
!Note 1
I IMC I
I I
INote 1
I IMD I
I I
INote 1
I IMA I
I I
INote 1
I IMA I
I I
INote 1
I IMB I
I I
/Note 1
I IMC I
I I
INote 1
I l>e I
I I
INote 1
I IMA I
I I
INote 1
I
)MB I
I POWER REDUNDANCEI SUPPLY SAS I Yesl SPDS I
I I
I I
I I
I SAS I Yesl Yesl I
I Yesl I
I Yesl Yes Yes Yes Yes Yes Yes I
SAS I
Yes'PDS I
I I
I I
I SAS I Yes)
I I
I, I
I Yesl I
I Yesl I
I Yesl Yes Yes DISPLAY LOCATION CR TSC EOF SCHEDULE/
JUSTIFICATION 1150A/0137A
I 7
i@
RIDA POWER AND LIGHT UCIE UNIT NO+
1 REGULATORY
.97 REV 3 "PARAMETER S SHEET" TYPE D VARI (Cont'd)
OCTOBE 985 I
I ITEMI TAG HO.
I REQUIRE-I EHVIRORKNTAL CORY I EXISTING RE UIRED I
MENT UALIFICATION DESCRIPTION TYPE I
IPI-8023C I SG 1B I
IPressure I
I IPI-8023D I
I IPR-8023A 2
IO to 1200 IProm ATM I Comply Ipsia IPressure I
I Ico 20X I
labove thel Comply ILowest I
ISafecy I
IValve I Comply I Set ting I
Note 11 Note ll Note 11 VARIABLE INSTRUMENT RANGE I
QA I
SEISMIC UALIPICATION Note 12 Note 12 Note 12 I
POWER I
REDUNDANCEI SUPPLYI N/A INote 1
IMC I
INote 1
I MD I
INote 1
IMA I
DISPLAY LOCATION CR TSC EOF Yes Yes Yes SCHEDULE/
JUSTIFICATION D18 IFT-08-1A ISa fety/Re" I lief Valve IPositions FT-08-1B lor Main ISteam Flow I
PI-08-1A IFI-08-1B I
I 2
lo co l6 x 106 I lb/hr I
I I
I Closed-INot I Closed I
I N/A Note 22 Note 22 Note ll Note ll N/A'/A INoce 6
I INs I
I I
INote 6 I
IHs I
I I
INote 6 I
INS I
I I
INote 6 I
I I
Yes Yes YeslThe main steaml Isafety re-I llieve valve Yeslposition in-Idication is lmonitored by Imeasuring mainl I steam flow.
I D19 IFT-9011 ISG 1A Peed-lwater Plow PIC-9011, D
3 I 0 to IO to 110' l6 x 10 IDesign lb/hr Flow N/A N/A N/A N/A INote 6 INS Note 6
NS SAS I
Yes Yes l Yesl Hote 25 1150A/0137A
RIDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE D VARIA 97 REV 3 SHEET" (Cont'd)
October 85 ITEM TAG NO.
VARIABLE DESCRIPTION TYPE GORY EXISTING RE UIRED I
REQUIRE IENVIRONMENTAL MENT UALIFICATION INSTRUMENT RANGE QA SEISMIC I
I POWER I
UALIFICATION I REDUNDANCEI SUPPLY I DISPLAY LOCATION CR TSC EOF SCHEDULE/
JUSTIFICATION FR-8011 9011 I
I IFT-9021 I
II FIG-9021 I
I IFR-8023/
I 9023 I
ISG 1B Feed-lwater Flow 3
IO to IO to 110XI l6 x 10 IDesign I lb/hr IFlow N/A N/A N/A N/A Note INS I
I INote 6 INS I
INote 6 INS I
INote 6 INS I
Yes SAS Yes Yes I Yesl I
I I
Yesl FI-09-2A I
I IFR-09-2A I
I IFT-09-28 I
I IFI-09-2B I
I IFR-09-2B I
I IFT-09-2C I
IIFI-09-2C I
I IFR-09-2C IAuxiliary IFeedwater IFlow HDR 1B I
IAuxiliary IFeedwacer IFlow HDR 1C I
I D20 IFT-09-2A IAuxiliary D
IFeedwater IFlow HDR 1A I
2 I
0 to 400 0 to 110X gpm IDesign IFlow 2
IO to 400 IO to 110XI I gpm IDesign IFlow 2
IO to 600 IO to 110X I Igpm IDesign I
IFlow N/A N/A N/A Note 16 Noce ll Note 11 Note 16 Noce ll Note 11 Note 16 Note 11 Note 11 N/A N/A N/A N/A N/A N/A Note 2A IIA I
I I
INote 2AI I IA I
I I
INote 2AI I IA I
I I
INote 2AI I IB I
I I
INote 2AI I IB I
I I
INote 2AI I IB I
I I
INote 2AI I IAB I
I I
INote 2AI IIAB I
I I
INote 2AI IAB SAS Yes Yes SAS Yes Yes SAS Yes Yes Yes I
I I
I Yesl I
Yesl I
I I
Yes Design flow rs l320 gpm.
I YeslDesign flow is l320 gpm.
Yes Design flow is l500 gpm.
D21 ILT-12-11 ICondensate IStorage I Tank Level LT-12-12 I
I LIS-12-11 1
l0-40 ft IPlant I Comply I Spec ific Note 11 Note 11 Note 11 Note 17 Note 17 Note 17 I LT-12-12 I
I I LT-12-11 I
I I LIS-12-12 I
I INoce 2 I
ISA I
I I
INote 2
I ISB I
I I
INote 2
I ISA I
I I
SAS SPDS SAS SPDS Yes I Yes l I
I I
I I Yesl I
I I
I YeslThe range pro-Ivided covers I3.4Z to more Yeslthan 100X of Ivessel heighc. 1150A/0137A
R 6
t
'I W t
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE D VARIA 97 REV 3 SHEET" (Cont'd).
October 85 VARIABLE ITEM TAG NO.
DESCRIPTION CATE-I TYPE GORY EXISTING RE UIRED I REQUIRE-IEHVIRONMENTAL UALIFICATION SEISMIC UALIFICATION I
POWER I DISPLAY LOCATION SCHEDULE/
JUSTIFICATION ILIS-12-12 I
Note 11 I
Note 17 I LIS"12-11 INote 2 I
Yes ISB I
I I
D22 IFT 07-1A I
I I FR-07-1A I
I IFR-07-1A, I
I IFT-07-1B I
I IFI-07-1B I
I I FR-07-1B I Containment ISpray from IShutdown IHeat Ex" Ichanger 1A IContainment ISpray from IShutdown I Heat Ex-lchanger 18 2
IO to 3500 IO to 110XI N/A Igpm IDesign I
IFlow 2
IO to 3500 IO to 110XI N/A I gpm IDesign I
IFlow Note 16 Note 11 Note ll Note ll Note 16 Hote 11 Note 11 N/A N/A N/A N/A INote 2AI I IA I
I I
INote 2AI I IA I
I I
INote 2AI I IA I
I I
INote 2AI I IB I
I I
INote 2AI I IB I
I I
INote 2AI I IB SAS IYes IYes I
Yes Yes Yes I
I SAS I Yesl Yes I
Yes Design flow is 2970 gpm.
D23 ITE-25-1 I
TE-25-2 ITE-2s-3 TE-25-4 ITE-2s-s TE-25-6 ITE-25-7 I
I ITE-25-8 Heat Removal I D
by the Con-I Itainment Fanl IHeat Removall Isystem 2
IO'F to I300'F I Plant ISpecific N/A IRefer to IJustification I Column I
I I
I N/A N/A NS NS I
NS NS NS NS NS IThe thermo-Icouple assem-I blies have been Ipurchased as Inonsafety lequipment.
IThey do not Iperform a Isafety function Iduring or after lan accident.
IAfter an ac" Icident, all Ifour contain-Iment fan cool-lers are sta~ted land remain op-erational. 1150A/0137A
qIDA POWER AND LIGHT UCIE UNIT NO+
1 REGULATORY G 97 REV 3 "PARAMETER S SHEET" TYPE D VARIA (Cont'd)
October S5 VARIABLE INSTRUMENT RANGE QA ITEM TAG NO.
CATE-I DESCRIPTION TYPE GORY EXISTING RE HIRED I REQUIRE-IENVIRONMENTAL MENT UALIFICATION SEISMIC I
I POWER I
UALIFICATION I REDUNDANCEI SUPPLYI DISPLAY LOCATION CR TSC EOF SCHEDULE/
JUSTIFICATION TR-25"1 Note 11 INote 2AI INS I
~
I I
I I
I Yesl YeslSAS
(
Yes Alarm SAS I
I IPoints only)
I I
I D24 TE-07-3A ITE-07-3B I
I ITI-07-3A I
I ITR-07-3B/
I 5B I
Containment IAtmosphere ITemperature I
I I
I I
I I
I I
I350'F I
I I
2 50 F to I
40'F to 400 F
Comply Note 16 Note 16 I
Note 11 Note 11 Note 12 Note 12 Note 12 Note 12 N A Note 1
IMA I
I I
INote 1
I IMB I
I I
INote 1
I IMA I
I I
INote 1
I IMB I
No No I
I I
I SAS I Yesl Yes SPDS Yes Yes The range pro-Ivided is ade-Iquate because I the maximum IMSLB tempera-Iture is 290'F.
D25 ITE-07-5A I
I ITE-07-5B I
I ITI-07-5A I
I ITR-07-3B/
5B IContainment ISump Water ITemperature I
2 l50'F to I50'F to I Comply l350'F 1250 F Note 16 I
Note 16 I
Note ll Note 11 Note 12 Note 12 Note 12 Note 12 INote 1
I IMA I
I I
INote 1
I IMB I
I I
INote 1
I IMA I
I I
I Note 1
I 1MB I
I No I No I
I I
I I
I I
SAS I Yesl Yesl Yes Yes D26 IFT-2212 IMakeup I
I Flow-In I
IFIA-2212 2
IO to 150 IO to 110XI N/A Igpm IDesign I Flow Note 16 Note 11 N/A N/A INote 2AI INS I
I I
INote 2AI INS I
SAS I
SPDS Yes Yesl YeslDesign Flow is l 132 gpm.
I I
I I
D27 FT-2202 Letdown Flowl D
FIA-2202 2
IO to 140 IO to 110XI Igpm IDesign IFlow N/A Note 11 Note 11 N/A N/A INote 2AI INS I
I I
INote 2AI INS I
I I
SAS I
SPDS Yes Yesl YesIDesign Flow is 132 gpm. 1150A/0137A
l I
I
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY 97 REV 3 "PARAMETER S SHEET" TYPE D VARIAB (Cont'd)
OCTOBER 85 VARIABLE INSTRUMENT RANGE QA ITEM TAG NO.
CATE-I DESCRIPTION TYPE GORY I EXISTING IRE UIRED I
REQUIRE IENVIRONMENTAL I SEISMIC MENT I UALIPICATION I UALIFICATION REDUNDANCE POWER SUPPLY DISPLAY LOCATION CR TS SCHEDULE/
JUSTIPICATION D28 ILT-2226 IVolume Con-I Itrol Tank I
I Level ILIC-2226 I
D 2
IO to ITop to I125" WC IBottom I
I IO to 100X I
N/A Note 20I Note 20I N/A N/A INote 2AI SAS INS I
I I
INote 2AI Yes INS I Yesl Yesl D29 TE-14-3A TE-14-3B ITR-25-1 Component ICooling IWater Temp Ito ESF System 2
O'F to 40'F to I300OF I200'F N/A Note 11 Note 11" Note ll N/A N/A Note 2A INs I
I I
INote 2AI INs I
I I
INote 2AI SAS INS Yes I
Yesl Yes SAS (Alarm I Points only)
I D30 IFT-14-1A I
I I PT-14-1B I
IIFIS-14-lA FIS-14-1B IComponent I Cooling IWater Flow lto ESF ISystem I
I I
I I
D 2
IO to IO to 110XI I15,000 gpmlDesign IPdow N/A Note 11 Note 11 Note 11 Note 11 N/A N/A INote 2AI SAS I IA I
I I
INote 2AI SAS I
IIB I
I I
INote 2AI Yes IIA I
I I
INote 2AI Yes I IB I
Yesl Yes lDesign flow I
I is 8500 gpm.
I I
Yesl Yesl D31 I LT-6607 LT-6608 I High Level D
IRadioactive I
ILiquid I
IHoldup Tank I
I IAs IBAD 1Cs I
I 1D Level 3
IO to 524" ITop to I
IBottom I
N/A N/A N/A N/A INote 2AI SAS INs I
I I
INote 2AI SAS INs I
I I
I Yesl Yes I
I I
I I Yesl Yes I
I I
I 1150A/0137A
t 0
(l I
L I
'1IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY 97 REV 3 "PARAMETER,S SHEET" TYPE D VARIAb Cont'd)
OCTOBER 85 ITEM TAG NO.
VARIABLE DESCRIPTION I
INSTRUMENT RANGE I
QA I
I REQUIRE IENVIRONMENTAL I SEISMIC UALIPICATION MENT UALIFICATION CATE-I TYPE GORY I EXISTING RE UIRED I
I POWER I DISPLAY LOCATION I SCHEDULE/
LT-6609 ILT-6610 I
IILIA-6607 I
I ILIA-6608 I
I ILIA-6609 I
I I LIA-6610 10 to 100Z I
INote 2AI INS I
I I
INote 2AI INS I
I I
INote 2AI INS I
I I
INote 2AI INS I
I I
INote 2AI INS I
I I
INote 2AI INS SAS SAS Yes Yes Yes Yes I
I I Yes I
I I
I Yes l Yesl Yesl D32 PI-6650 IPI-6651 I
I IPI-6652 Decay Tank D
IGas Pressurel 0 to 200 0 to 150Z I psig I Design I
IPressure I
N A N A N A No No No I
No I
I No I
No esrgn ressure lis 200 psig.
10nly local lindication lis provided.
IRange will be I
Ichanged 0 to 1300 psig in laccordance Iwith schedule lin Section V
litem 3.
D33 I EMERGENCY VENTILATION DAMPER POSITION D33AID"1 I
I ID-2 I
I ID-3 D-4 IIAir Supply IDampers to IECCS Pump IRooms A & B I
I I
I INo Indi-10pen/
I cating I Closed ILights IStatus I Will I Comply I
I Will I Comply I
I Will I
Comply I
I Will I Comply I
Note 231 Note 231 Note 231 Note 231 Note 231 Note 231, r
Note 231 Note 231 N/A INote ISA I
INote ISA I
INote ISB I
INote ISB I
21 No I
I 21 No I
I 21 No No I
I I
No I
I No I
No I
No I
I I
I I
No I
No I
I I
I I No I
No INote 23 I
I I
I I
I I
I I
I I
"34-1150A/0137A
~ '
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE D VARIAB 97 REV 3 SHEETu (Cont'd)
October 5
ITEM TAG NO.
VARIABLE TYPE DESCRIPTION INSTRUMENT RANGE CATE-I GORY I EXISTING RE UIRED QA REQUIRE I ENVIRONMENTAL UALIFICATION SEISMIC UALIFICATION I
POWER REDUNDANCEI SUPPLY DISPLAY LOCATION TSC CR EOF SCHEDULE/
JUSTIFICATION D33BID-5A I
I I D-5B I
I I D-6A I
I ID-6B I
I ID-7A D-7B ID-BA I
I ID-SB I
I ID-9A D-9B ID-11A I
I ID-11B I
I D33CID-12A I
I ID-12B I
I D33DID 13 D-14 IECCS Area IIsolation IInlet and IOutlet IDampers I
I IECCS Area I Isolation IInlet and 10utlet IDampers Ipipe Tunnel I
D IDampers to INormal Isystem I
I I ECCS HVE 9Ay I D
l9B Suction I
I6 Discharge I
IDampers lbefore and lafter HEPA 2
IOpcn/
IOpen/
I Closed I Closed IStatus IStatus 2
I No Indi-IOpen/
Icating Closed ILights Status IOpen/
Closed Status INo Indi-cating Lights 2
IOpen/
IOpen/
I Closed Closed Ist&tus Status 2
IOpen/
IOpen/
I Closed I Close IStatus IStatus I Comply I
I I Comply I
I Comply I
I I Comply I
I I Will I
Comply I.
I Will I Comply I
I Will I Comply I
I Will Comply I
I Comply I
I I Comply I
I I Will I
Comply I
I Will Comply I
I Comply I
I I Comply I
I I Comply I
I I Comply I
I I
Note 8
Note 8
Note 8
Note 8
Hoce 23 I
Note 23 I
Note 23 I
Note 23 I
Note 8 Note 8
Note 23 I
Note 23 I
Note 11 I
Note 11 I
Note 11 I
Note 11 I
Note 12 Note 12 Note 12 Note 12 Note 23 I
Note 23 I
Note 23 Note 23 I
Note 12 Note 12 Note 23 I
Note 23 I
Note 12 Note 12 Note 12 I
Note 12 I
N/A N/A N/A H/A INote 2
ISA I
INote 2 ISB I
INote 2
ISA I
INote 2 ISA I
INote 2
ISA I
INote 2 ISB I
INote 2
ISA I
INote 2
ISB I
INote 2
ISA I
INote 2
ISB I
INote 2 ISA I
INote 2
ISB I
INote 2 ISA I
INote 2 ISB I
INote 2 ISA I
INote 2 ISA I
SAS Yes SAS Yes SAS Yes SAS Yes SAS No No No No Yes SAS Yes SAS Yes SAS Yes Yes Yes No I
I No Yes Yes I Yesl Yesl I
I I
I I
I Yesl Yesl I
I I
I I
I I Yesl Yesl I
I I
I I
No I No I
I I
I No I
No I
I I
I I No I No I
I I
I Note 23 I
I No I No I
I I
I I
I I
I Yesl Yesl I
I I
I I Yesl Yes I
I I
I No I
No I
I I
I I No I No I
I I
I I No I No I
I I
I I
I Note 23 I
I I
I I
I I No I No I
I I
I I
I I
I Yesl Yesl I
I I
I I
I I Yesl Yesl 1150A/0137A
t t
I 0
t a1 e
IDA POWER AND LIGHT UCIE UNIT NO+
1 REGULATORY G "PARAMETER S TYPE D VARIAB 97 REV 3 SHEET" (Cont'd)
October 5
VARIABLE INSTRUMENT RANCE QA TAG NO.
DESCRIPTION TYPE CATE-I GORY EXISTING RE UIRED l MENT UALIFICATION
'SEISMIC I
POWER I DISPLAY LOCATION I
SCHEDULE/
ID-15 I
I ID-16 I
I D33EID-17 I
I ID-18 I
I ID-19 I
I IPilter IControl Rooml D
lEmerg Pil-Itration Fan lHVE"13A, 13BI
)Suction IDampers I
2 lOpen/
I Closed IStatus lOpen/
I Closed IStatus I
D34 HER PETY I
I I
[Start-up/
(Standby ITransformersl IPrimary IBreakers 1(240 RV)
I I
)Start-up/
IStandby I
I I
D34AIIM I
I IE I
IMOD 4 I
IMOD 5 I
D34BIVM/8881 I
I Plant ISpecific 2
lOpen/
I Close 2
lO to 300
)Plant Ikv I Specific I
I Trans formers I Iprimary IVoltage l(East IWest 240 kV I IBus)
IIStart-up/
D
)Standby (Transformer (Secondary I
IVoltage I
l(4 kV Buses I 1A2
& 1B2 IVoltage)
I D34C VM/916 2
lO to 5.25 IPlant IkV ISpecific IVM/91 7 I
I STATUS OP STANDBY POWER AND OT IENERGY SOURCES IMPORTANT TO SA Comply I
I I Comply I
I Comply I
I Comply I
I Comply N/A N/A N/A Note 11 Note 11 I
Note 11 Note 11 Note 11 Note 11 Note 11
.Note 11 Note ll Note ll Note 11 Note 11 Note 12 I
Note 12 I
Note 12 Note 12 Note 12 N/A N/A N/A N/A N/A N/A N/A ISA I
I I
I I
INS I
INS I
INS I
INS I
INS Yes Yes Yes Yes SAS Yes INS I
INS Yes Yes
)Note 2
I Yes ISB I
I I
INote 2 I
Yes ISB I
I I
lNote 2 I
SAS ISAB I
Yes I
I INote 2 I
Yes I
I INote 2 I
SAS I
I I
No I No I
I I
No I No I
I I
No I
No I
I I
No
/
No I
I I
I I Yes'esl No I
No No I
I No I
No I
I I
I I
I I
No i No I
I I
I I
I Yes 'es l I
I I
I I Yesl Yesl I
I I
I I
I I Yesl Yes) 1150A/0137A
II I
0
\\
4
IDA POWER AND LIGHT UCIE UNIT NO+
1 REGULATORY "PARAMETER S TYPE D VARIA 97 REV 3 SHEET" (Cont'd)
October 85 VARIABLE INSTRUMENT RANGE QA ITEM TAG NO.
D34D IAM/916 I
I AM/917 I
I I
D34E14 kV Bus 11A3 Bkr I
14 kV Bus 11B3 Bkr I
I D34FI4 kV Bus I lAB IBreakers I
I I
D34014 kV Bus 11A2 Bkr I
14 kV Bus 1102 Bkr I
I D34HI4 kV Bus llA3 Bkr 4 kV Bus 1B3 Bkr D34IIAM/942 I
I IVM/942 I
I IIL/942 I
I CATE I
DESCRIPTION TYPE I
GORY IScarc-up/
IStandby ITransformer I
ISecondary I
ICurrcnt l(4 kV Buses I
I 1A2
& 1B2 ICurrent)
I 14 kV Bus 1A31 I& 1B3 IBkr Status Ifrom 4 kV IBuses lA2 &
I 1B2 I
14 kV Bus lABI D
IBreakers I
IStatus from I
14 kV Buses I
llA3 & 1B3 I
I 14 kV Bus 11A2
& 1B2 IBkr Status Ito 4 kV IBuses 1A3 I
11B3 I
14 kV Bus 11A3
& 1B3 IBkr Status Ito 4 kV IBus 1AB I
D 2
14 kV Bus 1ABI D
IVolt'age, I
ICurrent IStatus I REQUIRE-IENVIRONMENTAL I EXISTING RE UIRED MENT UALIFICATION Note 11 Note 11 10 to 13000 A
I I
I I
I I
I 10pen/
I Close 2
10pen/
I Close IPlant ISpecific IPlant ISpecific I
IPlant I Specific N/A Note 11
'omply Note 11 Comply I
Note 11 10pen/
IPlant I Close ISpecific N/A Note 11 Note ll I Plant I Comply ISpecific 10pen/
IClose I
I I
I 10 to 1400 A IO to 15250 V
I Note ll Note ll I Plant ISpecific I
Comply I
I I
I Note 11 Note 11 Note ll SEISMIC UALIFICATION N/A Note 12 Note 12 Note 12 N/A Note 12 Note 12 Note 12 Note 12 POWER REDUNDANCE SUPPLY N/A INS I
INS I
Yes Yes I
No I No I
I I
No I No I
I.
I I
N/A.,
INote 3 I
Yes ISA I
I I
INote 3 I
Yes ISB I No I No I
I I
I I
I I
No I No-I N/A Note 3
SAB Yes No No N/A N/A N/A INote 5 I
Yes INA I
I I
INote 5 I
Yes INB I
I INote 3 I
Yes I
I INote 3 I
Yes I
I SAB I
I ISAB I
I ISAB I
.I No I No I
I I
I I
I I
I No I No I
I I
I I Yesl Yesl I
I I
I I
I I Yesl Yesl I
I I
I I
I I Yesl Yesl I
I I
I I
I I Yesl Yesl I
I I Yes I
I I
I Yesl I
I DISPLAY LOCATION CR TSC EOF SCHEDULE/
JUSTIFICATION 1150A/0137A
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE D VARIAB 97 REV 3 SHEET" (Cont'd)
October 5
VARIABLE INSTRUMENT RANCE QA CATE-I TAG NO.
ITEM D34JIVM/954 I
I IVM/964 I
I IIL/954 I
I IIL/964 I
I D34KIVM/954D I
I IVM/964D I
I I AM/954D I
I 1AM/964D I
I D34L14 kV Bus 1A3 Breaker 14 kV Bus I 1B3 IBreaker I
D34MI480 V Bus I lA2 I Breaker I
1480 V Bus I 1B2 IBreaker I
D34NI480 V Bus 11A2 Bkr 480 V Bus 1B2 Bkr GORY DESCRIPTION 14 kV Bus I 1A3
& 183 IVoltage I
I IDiesel IGenerator I 1A & 1B IMetering I
I I
D 2
14 kV Bus D
11A3
& 1B3 IFdr Bkr Sta-I Itus to 480 Vl IBuses lA2 &
I 1182 I
I I
I I
1480 V Buses I
D 11A2
& 1B2 I
IFdr Bkr I
IScatus from I
14 kV Buses 11A3
& 1B3 I
I 1480 V Buses I
D 11A2
& 1B2 IBkr Status to 480 V Bus 1AB I REQUIRE-I ENVIRONMENTAL I EXISTING RE UIRED I
MENT UALIFICATION Note 11 I Comply 10 to IPlant 15250 V
ISpecific Note 11'ote 11 Note 11 10 co I
5250 V
Plant I Comply Specific Note 11 Note 11 I
I 10 co 1800 A I
I I
I 10pen/
I Close I
I I
I I
I IOpen/
I close I
I IPlant ISpecific I
I I
I IPlant ISpecific I
I I
I I
IIPlant ISpecific Note 11.
Note 11 I Comply Comply I
Noce ll Note 11 Note 11 Note 11 IPlant I Comply ISpecific I
IOpen/
I Close Note 11 Note 11 SEISMIC UALIFICATION Note 12 Note '12 Note 12 Note 12 Note 12 Note 12 Note 12 Note 12 Note 12 Note 12 Note 12 Note 12
'ote 12 Note 12 DISPLAY LOCATION CR TSC EO SCHEDULE/
JUSTIFICATION N/A N/A N/A N/A N/A ISA I
I ISB I
I ISA I
I ISB I
I I SA I
I ISB I
I ISA I
I ISB I
I SAS Yes I
SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes SAS Yes INote 3 I
Yes IBA I
I I
I I
INote 3 I
Yes IBB I
I I
I I
INote 3 I
I INote 3 I
ISB I
I SAS Yes I Yesl I
I I
I I Yesl I
I I
I I Yes l I
I I
I I Yesl I
I I
I I Yesl I
I I
I I Yesl I
I I
I I Yesl I
I I
I I Yesl I
I I
I I No I
I I
I I
No I
I I
I I Yesl I
I I
I Yesl Yesl I
I Yesl I
I Yesl Yes Yesl I
Yesl Yesl I
I Yesl I
No No I
I I
I Yes I Yesl I
I I
Yesl I
I Yesl I
I I
Yesl I
I I
I Yes I
I I
POWER REDUNDANCE SUPPLY 1150A/0137A
0
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE D VARIA 97 REV 3 SHEET".
Cont'd)
October 85 VARIABLE INSTRUMENT RANGE QA ITEM TAG NO.
DESCRIPTION CATE-I I REQUIRE-I ENVIRONMENTAL UALIPICATIOH TYPE GORY I EXISTING RE HIRED I
MENT SEISMIC POWER I DISPLAY LOCATION I SCHEDULE/
D34Q IVM/1001 I I
I IVM/1002 I
I D34RIPT-18 16
-I I
IP I-18-16 D34S PT-18-9 PI-18-9 D34PI480 V Bus I IAB IBreakers 1480 V Bus I 1AB Bkrs IStatus Ifrom 480 V
IBuses 1A2 I 1B2 I
I125 V DC IBattery I 1A & 1B IVoltage I
I IStation Air I D
Ipressure I
2 lopen/
I Close
!plant I Comply ISpecific I
I I
I 2
lO to 150
)plant Ipsig ISpecific I
N/A Instrument Air Pressure D
2 IO to 150 I plant Ipsig Igpecific I
I I
I N/A 2
lO to 150 Iplant I Comply IV DC ISpecific I
I I
Note 11 Note 11 Note 11 Note 11 Note 11 Note 11 Note 11 Note 12.
Note 12 Note 12 N/A N/A I SAB Yes N/A N/A N/A ISA I
I ISB I
I INote 6
INS I
INote 6 INS I
INote 6 INS I
INote 6 INS I
SAS I
I I
Yes I
I I
SAS I
I I
Yes I
I Yes( Yes(
I I
I I
Yesl Yes(
I I
I I
Yes( Yes(
Yes'es I
I N/A INote 3 I
SAS I Yesl Yesl 1150A/0137A
I
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY C "PARAMETER S TYPE E VA 97 REV 3 SHEET" LES October 5
ITEM TAG NO.
I VARIABLE INSTRUMENT RANCE QA I REQUIRE-IENVIRONMEHTAL I
IDESCRIPTION TYPE I
GORY I EXISTING RE UIRED I
MENT UALIFICATION SEISMIC I
I POWER I DISPLAY LOCATION I
SCHEDULE/
El IRE-26-58 I
I IRE-26-59 I
I IRIS-26-58 I
I IRIS-26"59 I
I IRR-26"58 I
I IRR-26-59 IContainment IArea Radia-Ition (High IRange)
I I
I I
I I
I E
1 I 1 R/hr I 1 R/hy I Comply I to Ito 10 I
ll x 10 IR/hr I
I I R/hr Note 16 Note 16 Note 11 Note 11 Note 11 Note 11 Note 17 Note 17 Note 17 Note 17 Note 17 Note 17 I RE-26-59 I
I I RE-26-58 I
I I RIS-26-59 I
I I RIS-26-58 I
I I RR-26-59 I
I I RR-26-58 INote 2 I
ISA I
I I
INote 2 I
ISB I
I I
INote 2 I
ISA I
I I
INote 2
I ISB I
I I
INote 2 I
ISA I
I I
INote 2
I ISB SAS SPDS SAS SPDS Yes Yes Yes Yes I Yesl Yesl I
I I
I I
I I Yesl Yes l E2 I None I
I I
I I
IRadiation IExposure IRate inside I
Ibuildings I
lor areas I
lvhere ac-I Icess is re-Iquired to Iservice lequipment I important Ito safety I
IService/
I RAB ILocat ion I I Il.
CR area II I
- 12. Boric I acid Ipreconc.
II I filter areal I
I I
l3. Waste II I
Filter I I I
area II I10 1 R/hrl N/A Ito I
I104 R/hr I
I I
I llo 4 co II, I 101R/hr I
I I10-4 co II i 10-1R/hr II I
I I
I I 1 0 1
t0 I
I 10 R/hr I I I
I N/A N/A N/A IFixed high Irange area Iradiation mon" I itors located lin areas im-Iportant to Isafety vill not Ibe useful co an loperator.
He Iwill be carry-Iing a portable Ihigh range area Idetector on che Itrip to, at, land from the larea important Ito safecy.
IThere is a com-Iplete lov range larea radiation lmonitoring Isystem in the IRAB as listed. 1150A/0137A
0 y
IDA POWER AND LIGHT UCIE UNIT NO+
1 REGULATORY Q uPARAMETER.S TYPE E
V 97 REV 3 SHEET" LES October 85 VARIABLE INSTRUMENT RANGE QA TAG NO.
DESCRIPTION TYPE I4.
Laundry I I Ifilter I I larea II I
I I5.
Waste II Igas corn-II GORY I EXISTING I10"4 to I 10 R/hr I
I I 10 4 to I 101R/hr RE HIRED II II I
I IIII MENT UALIFICATION SEISMIC UALIFICATION POWER REDUNDANCE SUPPLY DISPLAY LOCATION CR TSC EO SCHEDULE/
JUSTIPICATION Ipressor II larea II I
I
~ l6. Changingl I
Ipump area II I
I I 7.
Hold upi I Idrain pump I& cond II Irecirc areall I
I 18.
Ion I I lexchanger II larea II I
I l9.
Ion I I lexchanger II larea E
II I
I I 10.
Ion I I lexchanger II larea E(W)
II I
I I 11.
Drum" I I Iming I I I station I
I area I
I I 12.
Purif-I I Ication areal I
I I
I 13.
Spent I I Iresin tank I I I area I I I
I I 14. Reactorl I
Idrain pump II larea II I
I I 15.
Decon-I I I tamination.I I I room area II I
I I 10 4 to I 10 R/hr I
I 10 4 to I 101R/hr I
I I
I 10 4 to I 10 R/hr I
I I 10 to I 10 R/hr I
I I 10 to I 101R/hr I
I I 10 4 to 101R/hr I 10-4 to I 101R/br I
I10 4 to I 101R/hr I
I I 10 to I 10 R/hr I
I I 10 4 to I 101R/hr I
I II II I
II II I
I I
II II I
I II II I
I IIII I
III II I
I IIIII III II I
III II I
I II II I
I 41 1150A/0137A
V l
J',
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE E VARIAB 97 REV 3 SHEET" Cont'd)
October 5
VARIABLE ITEM TAG NO.
DESCRIPTION TYPE I16.
HVAC Iroom "
II IExhaust fanll larea II I
II I 17.
Chem &I I IEquip drainl I ITank 1A II I
II I18.
Flash I I Itank pump II larea II I
II I 19.
Boro-I I Inometer II larea II I
II I20.
Ae-I I Irated wastell Istorage II Itank area II I
II l21.
Boric I I lacid con-II Icentrator II larea II I
CATE-I GORY I EXISTING RE UIRED I 10-to I I I 10 R/hr I I I
I I
I 10-4 to I I I 10 R/hr I I I
I I
I llo 4 to II 101R/hr I I I
I Il104to I
I 101R/hr I
I I 10-4 to I I I10 R/hr I I llo 4 to II I 101 R/hr I I I
REQUIRE IENVIRONMENTAL SEISHIC MENT UALIFICATION UALIFICATION REDUNDANCE POWER I DISPLAY LOCATION SCHEDULE/
JUSTIFICATION E3 IRSC-26-1L I
I IRSC-26-1M I
I IRSC-26-1H I
I I RSC-26-1F IContainment lor Purge IEffluent-INoble Gas I
I I
I I
IVent Flow IRate IO to I150, 000 Icfm IO to 110XI IVent IDesign IFlow I
18 x 10 I10 luci/cc to luci/cc tol I5 x 104 I105 luci/cc luCi/cc N/A Note 11 Note 11 Note 11 Note 11 Note 11 N/A N/A INote 2AI SAS I Yesl INS I
SPDS I
I I
I I
I INote 2AI SAS I Yesl INS I
SPDS I
I I
I I
I INote 2AI SAS I Yesl INS I
I I
I I
I I
INote 2AI SAS I Yesl INS I
I I
I I
I I
I I
I I
INote 2AI Yes I
INS I
I I
I I
YeslFlow is dilut-led, therefore, Irange is Yesladequate.
I I
Yesl I
I Yesl 1150A/0137A
4 t p
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY "PARAMETER S TYPE E VARIAB 97 REV 3 SHEETu (Cont'd)
October 5
VARIABLE ITEM TAG HO.
DESCRIPTION CATE-I I EXISTING TYPE I
GORY I REQUIRE-IEHVIRONMENTAL UALIFICATIOH RE UIRED I
MENT SEISMIC UALIPICATION I
POWER REDUNDANCEI SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULE/
JUSTIFICATION E4 IRSC-26-1L I
I IRSC-26-1M I
I I
IRSC"26-1H RSC-26-1F IReactor IShield IBuilding IAnnulus-INoble Gas I
I I
I I
I Vent Flow IRate E
2 ISx10 luCi/cc lto I5 x 104 luCi/cc IO to I 150> 000 I cfm I 10-6 luCi/cc lto I 104 luci/cc IO to 110XI IVent IDesign I P loM I
H/A Note 11 Note 11 Note 11 Note 11 N/A N/A INote 2AI INS I
I I
INote 2AI IHS I
I INote 2A INS I
INote 2AI INS SAS I Yesl Yes SPDS I
I I
I SAS I Yesl Yesl SPDS SAS I Yesl Yes I
I I
I SAS I Yesl Yesl IcT-2 E5 IRSC-26-1L I
I IRSC-26-1M RSC-26-1F CT"2 IAuxiliary IBuilding 1(including lany buildingl Icontaining I
Iprimary sys"I tern gases>
eg, Maste gas decay tank)
INoble Gas I
IVent Flov IRate E
I lg x 10-8 luci/cc I to l4 x 103 IuCi/cc 2
lo ro I 150, 000 Icfm 10 6
I uCi/cc I to I 103 luci/cc H/A I
I
(
I I
IO to 110XI N/A Ivent IDesign IFlow Note 11 Note 11 Note 11 Note 11 Note 11 N/A N/A N/A N/A INote 2AI Yes INS I
INote 2A INS I
INote 2AI INS SAS I Yes Yes SPDS I
I I
I SAS I Yes Yes SPDS Yesl Yesl INote 2AI Yes INS I
INote 2AI SAS I
INS E6 IRE-26-35 I
I I
IRIS-26-35 RR" 26-1D I
Icondenser IAir Removal I
ISystcm IExhaust-INoble Gas
-I 101-106 c/m IMhich is lequiva-I lent l5x106 I to l2x102 IuCi/cc 10-6 luci/cc Ito I 105 luci/cc N/A Note 11.
Note 11 Note 11 N/A N/A Yesl INote 2AI SAS I
INS I
SPDS I
~
I I
I INote 2AI Yes INS I
I I
INote 2AI Yes IHS I
YeslVent flow lis normally Idirected to Ithe plant I stack. 1150A/0137A
0
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY G "PARAMETER S TYPE E VARIAB 97 REV 3 SHEET" (Cont'd)
October 5
ITEM TAG NO.'ARIABLE INSTRUMENT RANGE gA CATE-I I REQUIRE-IENVIRONMENTAL EXISTING RE UIRED I
MENT UALIPICATION DESCRIPTION TYPE CORY SEISMIC UALIPICATION REDUNDANCE POWER I
SUPPLYI DISPLAY LOCATION CR TSC EOP SCHEDULE/
JUSTIFICATION None Vent Flow Rate I
IO to 110XI IVent I
I Design I
IFlow I
I No I No I No I
E7 IRSC-26-1L I
I I RSC-26-1M IRSC-26-1H I
I I RSC-26-1F CT-2 ICommon Plant l E
IVent or IMultipur-Ipose Vent I Discharging IAny of *bovel IReleascs "
INoble Gas I
I Vent Flow IRate lo to 1150, 000 lcfm IO to 110XI IVent IDesign IFlow 2
IS x 108 I106 luCi/cc to luCi/cc tol I5 x 104 ll03 Iuci/cc Iuci/cc N/A Note 11 Note 11 Note 11 Note 11 Note 11 N/A N/A INote 2AI INs I
I I
INote 2AI INS I
I I
INote 2AI INS I
I I
INote 2AI INS I
I I
INote 2AI INS I
I I
EAs I
SPDS I
I SAS I
SPDS I
I SAS I
I I
SAS I
Yes Yesl Yes I
I Yesl Yesl I
I I
I Yesl Yesl I
I I
I Yesl Yesl ES RE-2 2
I I
IRE-26-63 ICT-2 Vent from ISteam Gener-I lator Safety I
IRelief IValves or IAtmospheric IDump Valves I
l(Noble Gas)
I I
I 2
1 mR hr I t.o I 105 I mR/hr 10 luci/cc I to I 103 luci/cc N A Note 21 Note 21 Note 11 N A Note 2A INS I
I I
INote 2AI INS I
I I
I I
INote 2AI INS SAS SAS Yes Yes Yes Existing range I
Icomplies with I
Ithe required I Yesl Yesl range.
I In operation, I the radiation lemanating from Ithe main steam I line is mea-Isured in mR/hr, lwith hand Icalculations Iconverting the Ireadings to the lappropriate luCr/cc readrng.
I E9 RSC-26-2L IRSC-26-2M I
I IRSC-26-2H I
IA11 Other I Identified IRelease IPoints-Noble Gas (ECCS Area A)
IB x 108 ll06 E
2 luCi/cc to luCi/cc l5 x 104 I to IuCi/cc I 10 uCi /cc N/A Note ll Note 11 Note ll N/A N/A INote 2AI INs I
I
.I INote 2AI INS I
I I
INote 2AI INS I
I I
I I
I I
I SAS I Yes Yesl I
I 1150A/0137A
IDA POWER AND LIGHT UCIE UNIT No.
1 REGULATORY G "PARAMETER S TYPE E VARIAB 97 REV 3 SHEET" (Cont'd)
October'5 VARIABLE INSTRUMENT RANGE gA TAG NO.
DESCRIPTION TYPE I
REQUIRE IENVIRONMENTAL CATE-I GORY I EXISTING RE UIRED I
MENT UALIFICATION SEISMIC I
I POWER I DISPLAY LOCATION SCHEDULE/
IRSC-26-2F IVent Flow IRate IRSC-26-3L I
I IRSC-26-3M I
I IRSC-26-3H I (ECCS IArea B)
I I
I I
I RSC-26"3F Vent Flow IRate I
IRSC-26-4L l(Fuel I
IHandling I
IBuilding)
IRSC-26-4M I
I I
I IRSC-26-4H I
I I
RSC-26-4F IVent Flow Rate Io to I4o,ooo Icfm 2
0 to l4o, ooo Icfm Io to 110XI IVent IDesign IFlow I
0 to 110XI IVent IDesign IFlow N/A Note 11 Note 11 Note 11 Note ll Note 11 Note 11 Note 11 Note ll Note 11 Note 11 N/A N/A Note 2A Ns INote 2AI INS I
I I
INote 2AI INs I
I I
INote 2AI INS I
INote 2A INS I
INote 2AI INS I
I I
INote 2AI INs I
I I
INote 2AI INs I
I I
INote 2AI INS I
I I
I I
Yesl I
I Yesl Yes SAS I Yesl I
I I
I I
I I
I SAS I Yes l I
I SAS I Yes I
I I
I SAS I Yesl Yes Yes l I
I Yesl I
I Yesl Yesl I
I Yes l Yes Yes Elo IPARTICULATES AND I HALOGENS I
I I
IEFF-PART IAll Identi-Ified Plant EFF-HALO IRelease IPoints (ex-Icept Steam IGenerator Isafety Re-Ilief Valves I
lor Atmo-I Ipheric I
llo-3 luci/cc I to I lo2 uci/cc I
I I lo-3 Iuci/cc lto I lo2 uCi/cc N/A N/A N/A N/A N/A SAS I Yesl I
I SAS I Yes I Yes Yes I 1150A/0137A
/'
IDA POHER AND LIGHT UCIE UNIT NO.
1 REGULATORY G "PARAMETER S TYPE E VARIAB 97 REV 3 SHEET" Cont'd)
October 5
ITEM TAG NO.
CATE-I TYPE CORY DESCRIPTION ISceaa Dunp IValves and ICondenser lAir Reaoval I
ISystee Ex-Ihaust)
ISaapling Iwith On-sitel IAnalysis I
ICapability EXISTING I REQUIRE-IENVIRONMENTAL RE UIRED I
MENT UALIFICATION IO to 110XI I Vane IDesign I Flow I
SEISMIC I
I POWER I DISPLAY LOCATION SCHEDULE/
JUSTIPICATION ISee Ocher IEEfluent IPathways Ell I
Portable by FP&L IAirborne E
IRadio-Ihalogens andi IParticulates l
l(Portable I Sailing I
Iwith On-sitel IAnalysis I
ICapability)
I I
I 10-9 luCi/cc to llo J IuCi/cc I 10-9 luCi/cc tol I 10-J luci/cc I
~
N/A N/A N/A N/A N/A N/A I N/Al I
N/AI E12 IPortable Iby PP&L'plant and IEnvirons IRadiation I (Portable I lnstrumen-Itation)
E 3
I 10 3
~ I 10 3 IR/hr to IR/hr to I104 R/hr I104 R/hr I
IPhotons llo-3 IR/hr to I104 IR/hr Betel IRadia-I Itions andi ILow-I lenergy I
IPhotons I
N/A N/A N/A N/A N/A N/A I N/AI N/AI E13 IPortable Iby FP&L IPlant and IEnvirons IRadio-lactivity I
3 IIsotopic IAnalysis IIsotopic N/A IAnalysis I
N/A H/A N/A N/A N/A N/A N/A 1150A/0137A
0
IDA POWER AND LIGHT UCIE UNIT No.
1 REGULATORY "PARAMETER S TYPE E VARIAB 97 REV 3 SHEET" Cont'd)
October VARIABLE ITEM TAG NO ~
E14 IWD10-DL I
I IWD10-HW I
DESCRIPTION Ilo-meter I Wind IDirection WD60-DL 160-meter Wind IDirection IwD60-Hw 3
lo'o Is4o I
I 0 to 540'o to l360
(+s'I laccuracy lilith a I de flee" Ition of I 10').
Istarting I
Ispeed I
I less thanl IO.4 mps l(1. o Imph).
IDamping lratio Igreater Ithan or lequal to I
I0.4, de-llay dis-Itance I less thanl lor equal I
Ito 2 I
Imeters I
ISame as IAbove I
I N/A N/A N/A N/A INSTRUMENT RANGE gA CATE-I I REQUIRE-I ENVIRONMENTAL GORY I EXISTING RE UIRED MENT UALIPICATION SEISMIC UALIPICATION N/A N/A N/A INote 4 I
sAs INs I
I INote 4 I
SAS INS I
I Yesl YeslSee Note 7.
I I
I I
I I
I Yesl Yesl I
I I
I I
POWER I DISPLAY LOCATION I
SCHEDULE/
I N/A INote 4 I
SAS I Yesl YesISee Note 7.
INS I
I I
I I
INote 4 I
SAS I Yes Yes INS E15 WS10-DL llo-meter IWind Speed IWS10"HW E
3 lo to I120 mph Io to 22 Imps (50 Imph)
+
I0.2 mps I (o. s Imph) ac-Icuracy Ifor Ispeeds lless thanl l2 mps I
l(5 mph),
I lloX for Ispeeds I
N/A N/A N/A N/A INote 4 I
SAS INs I
I I
INote 4 I
SAS INS I
I Yesl YeslSee Note 7.
I I
I I
Yesl Yesl 47-1150A/0137A
0 I'
~
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY G "PARAMETER S TYPE E VARIAB 97 REV 3 SHEET" Cont'd)
October 5
ITEM VARIABLE CATE-TAG NO.
DESCRIPTION TYPE GORY EXISTING RE UIRED lin excessl lof 2 mps I
l(5 mph),
I Iwith a I
Istarting I
Ithresholdl INSTRUMENT RANGE QA REQUIRE IENVIRONMENTAL MENT UALIFICATION SEISMIC UALIFICATION POWER REDUNDANCE SUPPLY DISPLAY LOCATION CR T
0 SCHEDULE/
JUSTIFICATION IWS60-DL I60-meter IWind Speed WS60-HW E
3 IO to I120 mph lof less Ithan 0.4 Imps (1.0 Imph) and la dis-Itance'constant Inot to lexceed l2 meters I
ISame as IAbove I
I I
I I
I I
I N/A N/A N/A N/A INote 4 I
SAS INS I
I I
INote 4 I
SAS INS I
I I
Yesl YeslSee Note 7.
I I
I I
I I
Yesl Yesl I
I I
I E16 Inmet Central IData IStation IEstimation lof Atmo-Ispheric IStability I-15 F to I 15 F.
IThis is lacquired I by taking I the dif-lference Ibetween Ithe 60-Imeter Itemp and Ithe 10-Imeter Itemp.
IBased on Ivert ical Itempera-Iture Idiffer-lence froml Iprimary lmeteoro-llogical
- Isystem, I-5'C to I 10'C I(-9 F to I18'F) andi I+ 0.15 C
laccuracy I
Iper 50-I Imeter in-I N/A N/A N/A N/A INote 4 I
SAS I Ycsl YeslSee Note 13.
NS Itervals I(+ 0.3'F laccuracy 1150A/0137A
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY G "PARAMETER S TYPE E VARIAB 97 REV 3 SHEET" (Cont'd).
October ITEM TAG NO.
VARIABLE DESCRIPTION CORY EXISTING RE HIRED Iper 164-I foot in-Itervals)
I or analo-I Igous I
lrange forl lalterna-I I tive sta-I lbility I
lestimatesl INSTRUMENT RANGE QA REQUIRE I ENVIRONMENTAL MENT UALIFICATION SEISMIC UALIFICATION I
POWER I DISPLAY LOCATION I
SCHEDULE/
JUSTIPICATION E17A PC-GA Gross Activity IPC-I-131 I
I I
IPC-XE-133 PC-CO-60 IPC-CS-134 I
I I
IPC-B I
I IPC-CL I
I IPC H2 I
I IIodine I
I I
IXenon I
I I
ICobalt I
I II Cesium IBoron IContent I
IChloride IContent I
IDissolved IHydrogen I
I PRIMARY COO I AND SUMP 1 uCi/ml I to I10 Ci/ml I
I 1 uCi/ml to 10 Ci/ml ll uCi/ml Ito I10 Ci/ml I
I 1 uCi/ml lto I10 Ci/ml I
I 10 to I 10 IuCi /ml I
IO to 25 x I103 ppm I
l15 to Inf I ppm I
IO to 100X ITotal Gas Iby Volume I
IIl uCi/ml I to I10 Ci/ml I
I I
IIsotopic I
IAnalysis I
I I
I I
I Isotopic I
IAnalysis I
I IIIsotopic IAnalysis I
I I
IIsotopic IAnalysis I
I I
I I
lo to I.
l6000 ppm I
I I
IO to 20 Ippm I
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SAS I Yes I
I I
SAS I Yesl I
I I
I I
I SAS I Yesl I
I I
SAS I Yesl I
I I
Yesl I
I I Yesl I
I I
I I Yesl I
I I
Yes Yesl I
I I
YeslVariables for IItem E17A are Imanually input-Ited to SAS.
Yesl I
I I
Yesl I
I Yesl I
I YeslSee Note 14.
I I
IVariables for lItem E17A are Imanually rnput-Ited to SAS.
SAS I Yesl Yes 1150A/0137A
IDA POWER AND LIGHT UCIE UNIT Now 1
REGULATORY G "PARAMETER S TYPE E VARIAB 97 REV 3 SHEET" (Cont'd)
October 5
VARIABLE TYPE ITEM TAG No.
DESCRIPTION INSTRUMENT RANGE QA CATE-I I REQUIRE-IENVIRONMENTAL I EXISTING UALIFICATION RE UIRED I
MENT sEIsMIG I
I PowER UALIPICATION I REDUNDANCEI SUPPLY DISPLAY LOCATION SCHEDULE/
PC-02 IPC-pH I
IDissolved loxygen I pH I
3 lo to I
5 ppm lo to I
10 ppm lo to I
20 ppm lo co I
100Z I
I 1 to 13 I
lo to 20 Ippm I
I 1 to 13 I
N/A N/A N/A N/A N/A N/A N/A N/A.
N/A N/A I
SAS I Yesl YeslSee Note 14.
SAS I Yesl Yesl See Note 14.
I I
I E17B I S-GA I
I IIs-I-131 S-XE-133 Is-c0-60 I
I I
IS-CS-134 I
I I
I s-B I
I Is-CL I
I I S-pH I
I IGross Activity IIodine I
I I
IXenon I
I I
'Cobalt ICesium I
I I
IBoron IContent IIChloride IContent I
IpH I 1 uCi/ml Ito Ilo Ci/ml I
I 1 uCi/ml Ico llo Ci/ml I
I 1 uCi/ml lco Ilo Ci/ml Ill uCi/ml to 10 Ci/ml I 10 to I 107 I uCi /ml I
lo to 25 x I 103 ppm I
lo to 20 lppm IIl to l13 I 1 uCi/ml to 10 Ci/ml I Isotopic IAnalysis I
IIIsotopic IAnalysis I
IIlsotopic IAnalysis I
Illsotopic IAnalysis I
I lo to l6000 ppm I
lo to 20 Ippm Ill co I13 N/A I
I I
I N/A I
N/A I
N/A I
I I
I N/A I
N/A I
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A H/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SAS SAS SAS SAS SAS SAS SAS SAS Yes l I
I I
I Yesl I
I I
I Yesl I
I I
I I Yesl Yes Yesl Yes IVariables for I Item E17B are Imanually input" Ited to SAS.
Yesl I
I Yesl I
I Yes I I Yesl YeslVariables for IItem E17B are Imanually inpuc" Iced to SAS.
I Yesl Yesl I
I I
I I
I I
I I
I Yesl Yesl ICONTAINMENT AIR E18 I CA-H2 I
IHydrogen IContenc lo to 10 IVol - Z Io co 10 IVol - Z N/A N/A N/A N/A N/A IVariables for litem E18 are Imanually input-Ited to SAS.
I I
I I
SAS Yes Yes I
I I 1150A/0137A
0
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY G 97 REV 3 "PARAMETER S SHEET TYPE E VARIAB (Cont'd)
October 85 VARIABLE ITEM ICA-02 10xygen I
IContent I
I ICA-XE-133 IXenon ICA-I"131 I
I I
I ICA-CS I Iodine ICesium ICA-OTH 10thers TAG NO.
DESCRIPTION CATE-I REQUIRE-IENVIRONMENTAL SEISMIC UALIPICATION UALIFICATION 3
10 to 30 10 to 30 IVol - X IVol X I
I 3
110 6 to I Isotopic 1106 IAnalysis luCi/ml I
I I
3 110 I I Isotopic Ito IAnelysis 1105 luCi/ml I
110 '0 I to IIsotopic IAnalysis 1103 I uCi /ml I
110"6 to 1103 IuCi /ml I
I N/A N/A I
I I
I N/A I
N/A I
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A GORY I EXISTING RE UIRED I
MENT REDUNDANCE N/A N/A N/A N/A N/g N/A N/A SAS I Yesl Yesl I
I I
I I
I I Yesl Yesl N/A SAS I Yes Yesl I
N/A SAS I Yesl Yesl I
N/A I
I I
I SAS Yes Yes POWER I DISPLAY LOCATION SUPPLYI CR TSC EOP SCHEDULE/
JUSTIFICATION
- 51 1150A/0137A
0 0
IDA POWER AND LIGHT UCIE UNIT NO.
1 REGULATORY Gl 97 REV 3 "PARAMETER S SHEET" NO October 85 Note 1:
120 VAC, Class 1E, uninterruptable power supply.
Note 2:
120 VAC, Class 1E, offsite power backed by an emergency diesel generator.
Note 2A:
120 VAC, Non Class 1E, offsite power backed by an emergency diesel generator.
Note 3:
125 VDC, Class 1E battery.
Note 4:
120 VAC, non-Class 1E offsite power.
Note 5:
125 VDC, non-Class 1E battery.
Note 6:
120 VAC, non-Class 1E, uninterruptable power supply.
Note 7:
Wind Direction and speed is fed to the Inmet Central Data Station (Control Roon) via FM Signal Transmission (Analog signal provided to SAS).
- Also, a future telephone line link will provide a redundant input to SAS.
At the Central Data Station, Wind Direction and speed are recorded on analog recorders.
Note 8:
Qalified per 79. 01B analysis.
Note 9:
Category 1 redundancy does not apply because a secondary containment isolation valve is normally available on each line penetrating the containment.
Exceptions to the rule are explained in FSAR Section 6.2.4 ~
Note 10:
Deleted I
Note 11:
Note 12:
Note 13:
The equipment is located in a mild environment and will withstand its service location conditions.
Comply with the seismic qualification program which was the basis for plant Licensing.
60 meter temp and 10 meter temp is fed to the Inmet Central Data Station (Control Room) via Fm signal transmission (Analog signal provided to SAS).
- Also, a future telephone line link will provide a redundant input to SAS.
A differential amplifier accepts che two signals and produces a voltage which represents differential temperature.
This differential temperature is recorded in the central data station.
Note 14:
Indicator and recorder are located on post accident sampling control panel.
Note 15:
'IheseH2 sampling valves are manually operated and therefore are not displayed as part of the SAS system.
These valves do not receive CIAS signal.
Note 16:
Comply with 10CFR50.49 and NUREG-0588 Category I (IEEE-323-1974) for environmental qualification.
Note 17:
Note 18:
Comply with IEEE-344-1975 for seismic qualification.
Will comply with 10CFR50.49 and NUREG-0588 Category 1 (IEEE-323-1974) for environmental qualification.
Note 19:
Will comply with IEEE 344-1975 for seismic qualification.
52-1150A/0137A
IDA POWER AND LIGHT CIE UNIT NO.
1 REGULATORY 97 REV 3 "PARAMETER S SHEET" NOTES (Co
'd)
OCTOBER 85 Note 20:
'Ihe sensor is located in a harsh environment post accident.
However, it is not required to perform a safety function or mitigate the consequence of an accident, it is provided for plant surveillance during normal operation.
High quality instrumentation is utilized.
Note 21:
The sensor is located in a harsh environment only during MSLB-trestle.
However, it is not required to perform a safety function or mitigate the consequences of an accident.
It is provided for plant surveillance only.
Note 22:
Note 23:
Note 24:
The sensor is located in a harsh environment post accident.
The equipment was provided for plant surveillance during normal operation and non"accident transients.
The type of equipment utilized has been generically qualified to a lesser environment than in-containment accident environment for this plant.
'I Position indicating lights will be implemented in accordance with the schedule provided in Section V item 4.I FPL provides redundant qualified instrumentation for steam generator level, however it is narrow range.
A wide range non-safety channel is available and meets the recoaraended
- range, but it is not Category 1 instrumentation.
FPL considers the existing instrumentation at St Lucie to be adequate for its intended function.
R.G.
1.97 requires certain instrumentation to "provide information required to permit the operator to take preplanned manual actions to accomplish safe plant shutdown" (i.e., accident identification and mitigation) and to determine if systems important to safety are performing their intended function (i.e., availability of the SGs as heat sinks).
Low steam generator level is an indicator of a number of possible events; including a Main Steam Line Break (MSLB), Loss of Feedwater (LOFW) and Loss of Load (LOL) events.
For each of these
- events, however, the qualified SG pressure instrumentation must be used for identification of the specific transient.
The accident analyses in Chapter 15 of the Final Safety Analysis Reports (FSAR) for both.St Lucie Units 1 and 2 address these events.
In all
- cases, no operator action is credited during the first minutes of an event.
Automatic actions will protect the plant until the operator can identify the event, using the existing instrumentation, and take appropriate action.
The availability of the SCs as heat sinks is determined from SG pressure.
Other instrumentation available to determine SG availability are the auxiliary feedwater system pressure and flow instrumentation and the main feedwater flow instrumentation.
This additional information is sufficient to assess SG availability as a heat sink for the RCS.
Note 25:
FPL considers the existing instrumentation adequate for its function.
I Thjs item was identified as being acceptable to NRC.
The design main feedwater flow is 5.85 x 10 lb/hr, which would require a 0 to 6.4 x 6
10 lb/hr instrument range.
The existing range is close to the required range and will adequately monitor operation of this system in post-accident conditions.
This is an acceptable deviation from R.G.
- 1. 97.
Note 26:
FPL identified that the instrumentation for determining pressurizer level is narrow range.
This referred to the instrument calibraion range of 175" to 349" W.C. differential pressure, which corresponds to wide range pressurizer level when the pressurizer is at 650 F (i.e., hot calibrated instrumentation).
53-1150A/0137A
I k
g 1