A SCANA COMPANY Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555
Dear Sir/ Madam:
George A. Lippard Vice President, Nuclear Operations 803.345.4810 December 15, 2017
Subject:
VIRGIL C. SUMMER NUCLEAR STATION (VCSNS), UNIT 1 DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 LICENSEE EVENT REPORT (LER 2017-006-00)
TECHNICAL SPECIFICATION ACTION NOT MET FOR INOPERABLE OXYGEN MONITOR Attached is Licensee Event Report (LER) 2017-006-00, for the Virgil C. Summer Nuclear Station. This report provides details concerning a missed action requirement of taking waste gas samples as required by Technical Specification 3.3.3.9 Table 3.3-13 Item 1.a (Action 44).
This report is submitted in accordance with 10 CFR 50. 73(a)(2)(i)(B).
Should you have any questions, please call Mr. Michael S. Moore at (803) 345-4752.
JRB/GAL/rp Attachment c:
K. B. Marsh S. A Byrne J. B. Archie N.S. Carns J. H. Hamilton G. J. Lindamood W. M. Cherry C. Haney Very truly yours,
\\
S. A Williams NRC Resident Inspector L. W. Harris P. Ledbetter J. C. Mellette ICES Coordinator K. M. Sutton INPO Records Center Marsh USA, Inc.
Maintenance Rule Engineer NSRC RTS (CR-17-05725)
File (818.07)
PRSF (RC-17-0170)
SCE&G I V.C. Summer Nuclear Station
NRG FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY 0MB: NO. 31 50-0104 EXPIRES: 03/31/2020
(()4..2017) bt!Q;f/www nrQ.9Qvire2!Jiog-rmiQQQ-QQlle!.liQns/n1Jregs/sl2ff/sr:l Q22/r~I) the NRG may not conduct or sponsor, and a person is not required to respond to, the infonnation collection.
- 3. PAGE VC Summer - Unit 1 05000 395 1 OF 3
- 4. TITLE TECHNICAL SPECIFICATION ACTION NOT MET FOR INOPERABLE OXYGEN MONITOR
- 5. EVENT DATE
- 6. LER NUMBER
- 7. REPORT DATE
- 8. OTHER FACILITIES INVOLVED I
SEQUENTIAL I REV FACILITY NAME DOCKET NUMBER MONTH DAY YEAR YEAR MONTH DAY YEAR NUMBER NO.
05000 FACILITY NAME OOCKET NUMBER 10 31 2017 2017 -
006 -
00 12 15 2017 05000
- 9. OPERATING MODE
- 11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR §: (Check all that apply)
D 20.2201cb)
D 20.2203(a)(3)(i)
D 50.73(a)(2)(ii)(A)
D 50.73(a)(2)(viii)(A) 1 D 20.2201(d)
D 20.2203(a)(3)(ii)
D 50.73(a)(2)(ii)(B)
D 50.73(a)(2)(viii)(B)
D 20.2203(a)(1)
D 20.2203(a)(4)
D so.73(a)(2)(iii)
D 50.73(a)(2)(ix)(A)
D 20.2203(a)(2)(i)
D 50.36(c)(1)(i)(A)
D 50.73(a)(2)(iv)(A)
D 50.73(a)(2)(x)
- 10. POWER LEVEL D 20.2203(a)(2)(ii)
D 50.36(c)(1)(ii)(A)
D 50.73(a)(2)(v)(A)
D 73.71(a)(4)
D 20.2203(a)(2)(iii)
D so.36(c)(2)
D 50.73(a)(2)(v)(B)
D 73.71(a)(s)
D 20.2203(a)(2)(iv)
D so.46(a)(3)(ii)
D 50.73(a)(2)(v)(C)
D 73.77(a)(1) 100 D 20.2203(a)(2)(v)
D 50.73(a)(2)(i)(A)
D 50.73(a)(2)(v)(D)
D 73.77(a)(2)(i)
D 20.2203(a)(2)(vi)
({] 50.73(a)(2)(i)(B)
D 50.73(a)(2)(vii)
D 73.77(a)(2)(ii)
D so.73(a)(2)(i)(C)
D OTHER Specify in Abstract below or in
3.0 SAFETY SIGNIFICANCE
The Waste Gas Holdup System oxygen monitors are not included in the PRA model.
There was no risk impact from this event. A grab sample was taken at 0405. Analysis determined oxygen levels were satisfactory.
4.0 PREVIOUS OCCURRENCE No previous occurrences identified within the last three years.
5.0 CORRECTIVE ACTIONS
The Station's corrective actions are documented in the CR-17-05725 Quick Cause Evaluation.
The below two actions are being completed to reinforce station expectations of communications during shift turnovers and the time requirements for taking grab samples associated with the Waste Gas System.
- 1. Operations Management to discuss Missed Grab Sample with operations shifts during training department meetings.
- 2. Chemistry to discuss missed Grab Sample with shift chemists. Page 3
of 3
|
|---|
|
|
| | | Reporting criterion |
|---|
| 05000395/LER-1917-001, Regarding C Main Feedwater Failure to Trip Results in Loss of Emergency Feedwater Auto Start Actuation Signal | Regarding C Main Feedwater Failure to Trip Results in Loss of Emergency Feedwater Auto Start Actuation Signal | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000395/LER-1917-002, Regarding Low Feedwater Flow to the B Steam Generator Causes Automatic Reactor Trip | Regarding Low Feedwater Flow to the B Steam Generator Causes Automatic Reactor Trip | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000395/LER-1917-003, For Virgil C. Summer Nuclear Station, Unit 1, Regarding Failed Lightning Arrester on Main Transformer Causes Reactor Trip | For Virgil C. Summer Nuclear Station, Unit 1, Regarding Failed Lightning Arrester on Main Transformer Causes Reactor Trip | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000395/LER-1917-004, Regarding Actuation of a Emergency Diesel Generator | Regarding Actuation of a Emergency Diesel Generator | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000395/LER-1917-005, V.C Summer, Unit 1, Regarding Automatic Reactor Trip Due to Main Turbine Trip | V.C Summer, Unit 1, Regarding Automatic Reactor Trip Due to Main Turbine Trip | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000395/LER-1917-006, Regarding Technical Specification Action Not Met for Inoperable Oxygen Monitor | Regarding Technical Specification Action Not Met for Inoperable Oxygen Monitor | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
|