| 05000317/LER-1980-001-03, /03L-0:on 800104,high Pressure Safety Injection Loop 12A Stop Would Not Move to Throttled Position.Caused by Loose Termination on One Electrical Lead Terminating at Valve Torque Switch.Terminal Screw Tightened | /03L-0:on 800104,high Pressure Safety Injection Loop 12A Stop Would Not Move to Throttled Position.Caused by Loose Termination on One Electrical Lead Terminating at Valve Torque Switch.Terminal Screw Tightened | |
| 05000318/LER-1980-001, Forwards LER 80-001/03L-0 | Forwards LER 80-001/03L-0 | |
| 05000318/LER-1980-001-03, /03L-0:on 800225,although Low Pressure Safety Injection Pump 21 Was Placed Out of Svc for Maint, Containment Spray Pump 21 Was Disassembled.Caused by Verbal Communication Error | /03L-0:on 800225,although Low Pressure Safety Injection Pump 21 Was Placed Out of Svc for Maint, Containment Spray Pump 21 Was Disassembled.Caused by Verbal Communication Error | |
| 05000318/LER-1980-002-03, /03L-0:on 800107,refueling Water Tank Narrow Range Level Indicator Was in Alarm W/Low Level,But Instrument Did Not Indicate Alarm Conditions.Caused by Faulty Indicator Alarm light-emitting Diode.Diode Replaced | /03L-0:on 800107,refueling Water Tank Narrow Range Level Indicator Was in Alarm W/Low Level,But Instrument Did Not Indicate Alarm Conditions.Caused by Faulty Indicator Alarm light-emitting Diode.Diode Replaced | |
| 05000318/LER-1980-002, Forwards LER 80-002/03L-0 | Forwards LER 80-002/03L-0 | |
| 05000317/LER-1980-002-04, /04T-0:on 800322,instantaneous Hourly Average for Condenser Temp Rise Observed in Excess of Tech Spec Limit. Caused by Operator Inattention to Temp Rise Across Condenser & Environ Conditions | /04T-0:on 800322,instantaneous Hourly Average for Condenser Temp Rise Observed in Excess of Tech Spec Limit. Caused by Operator Inattention to Temp Rise Across Condenser & Environ Conditions | |
| 05000317/LER-1980-002, Forwards LER 80-002/04T-0 | Forwards LER 80-002/04T-0 | |
| 05000317/LER-1980-003-03, /03L-0:on 800108,during Routine Containment Air Lock Surveillance,Emergency Escape Lock Leakage Found Greater than Allowed.Caused by Excessive Leaking of Packing Glands for Doors Handwheels.Packing Tightened | /03L-0:on 800108,during Routine Containment Air Lock Surveillance,Emergency Escape Lock Leakage Found Greater than Allowed.Caused by Excessive Leaking of Packing Glands for Doors Handwheels.Packing Tightened | |
| 05000317/LER-1980-003, Forwards LER 80-003/03L-0 | Forwards LER 80-003/03L-0 | |
| 05000318/LER-1980-003-03, /03L-0:on 800110,repairs to Number 21 Diesel Generator Jacket Coolant Sys Required Diesel Be Out of Svc. Caused by Leaking Gasket on Jacket Cooling Water Discharge Header.Leak Located & Repaired | /03L-0:on 800110,repairs to Number 21 Diesel Generator Jacket Coolant Sys Required Diesel Be Out of Svc. Caused by Leaking Gasket on Jacket Cooling Water Discharge Header.Leak Located & Repaired | |
| 05000318/LER-1980-003, Forwards LER 80-003/03L-0 | Forwards LER 80-003/03L-0 | |
| 05000317/LER-1980-004, Forwards LER 80-004/03L-0 | Forwards LER 80-004/03L-0 | |
| 05000317/LER-1980-004-03, /03L-0:on 800110,low Flow Alarm Received for Containment Particulate & Gaseous Radiation Monitor Sys. Caused by Gasket Leakage at Particulate Detector Sample Psig.Gaskets Replaced & Flow Restored to Normal | /03L-0:on 800110,low Flow Alarm Received for Containment Particulate & Gaseous Radiation Monitor Sys. Caused by Gasket Leakage at Particulate Detector Sample Psig.Gaskets Replaced & Flow Restored to Normal | |
| 05000318/LER-1980-004-03, /03L-0:on 800121,during Steady State Operation, Received Indication of Several Spurious Loss of Load Trips on Channel B.Cause of Event Unknown.Troubleshooting Revealed Electrical Noise on Input Leads | /03L-0:on 800121,during Steady State Operation, Received Indication of Several Spurious Loss of Load Trips on Channel B.Cause of Event Unknown.Troubleshooting Revealed Electrical Noise on Input Leads | |
| 05000318/LER-1980-004, Forwards LER 80-004/03L-0 | Forwards LER 80-004/03L-0 | |
| 05000318/LER-1980-005, Forwards LER 80-005/03L-0 | Forwards LER 80-005/03L-0 | |
| 05000318/LER-1980-005-03, /03L-0:on 800122,five Channel B Trip Units Were Bypassed Due to Spurious High Power Levels.Caused by Noise from Excore Nuclear Instrument Upper Subchannel Detector. Troubleshooting Planned for Next Cold Shutdown | /03L-0:on 800122,five Channel B Trip Units Were Bypassed Due to Spurious High Power Levels.Caused by Noise from Excore Nuclear Instrument Upper Subchannel Detector. Troubleshooting Planned for Next Cold Shutdown | |
| 05000317/LER-1980-005, Forwards LER 80-005/03L-0 | Forwards LER 80-005/03L-0 | |
| 05000317/LER-1980-005-03, /03L-0:on 800325,during Normal Operation,Control Room Air Conditioning Unit 12 Tripped.Caused by Failure of Diaphragm on Unipressure Valve.Valve Replaced & Unit Returned to Svc | /03L-0:on 800325,during Normal Operation,Control Room Air Conditioning Unit 12 Tripped.Caused by Failure of Diaphragm on Unipressure Valve.Valve Replaced & Unit Returned to Svc | |
| 05000317/LER-1980-006, Forwards LER 80-006/03L-0 | Forwards LER 80-006/03L-0 | |
| 05000317/LER-1980-006-03, /03L-0:on 800103,while Performing Routine Surveillance Test,Control Element Assembly 60 Was Dropped Into Core.Cause Unknown.All Parameters Found Normal & No Problems Encountered.No Further Action Anticipated | /03L-0:on 800103,while Performing Routine Surveillance Test,Control Element Assembly 60 Was Dropped Into Core.Cause Unknown.All Parameters Found Normal & No Problems Encountered.No Further Action Anticipated | |
| 05000318/LER-1980-006, Forwards LER 80-006/03L-0 | Forwards LER 80-006/03L-0 | |
| 05000318/LER-1980-006-03, /03L-0:on 800126,during Steady State Operation, Reactor Protective Sys Channel a High Power,Low Flow,Axial Flux Offset & Thermal Margin/Low Pressure Trip Units Bypassed for Corrective Maint.Meter Input Jacks Cleaned | /03L-0:on 800126,during Steady State Operation, Reactor Protective Sys Channel a High Power,Low Flow,Axial Flux Offset & Thermal Margin/Low Pressure Trip Units Bypassed for Corrective Maint.Meter Input Jacks Cleaned | |
| 05000317/LER-1980-007-01, /01X-0:on 800129,while Conducting Core Flush, Emergency Relief Valve RC-404 Opened.Apparently Caused by High Pressure Signal from Overpressure in Protection Circuit.Valve Shut W/Manual Override | /01X-0:on 800129,while Conducting Core Flush, Emergency Relief Valve RC-404 Opened.Apparently Caused by High Pressure Signal from Overpressure in Protection Circuit.Valve Shut W/Manual Override | |
| 05000318/LER-1980-007, Forwards LER 80-007/03L-0 | Forwards LER 80-007/03L-0 | |
| 05000318/LER-1980-007-03, /03L-0:on 800130,while Performing Routine Surveillance Testing,Discovered Control Element Assembly 54 Would Not Drive Down Electrically.Cause Not Known.Rod Became Operable During Investigation of Rod Circuitry | /03L-0:on 800130,while Performing Routine Surveillance Testing,Discovered Control Element Assembly 54 Would Not Drive Down Electrically.Cause Not Known.Rod Became Operable During Investigation of Rod Circuitry | |
| 05000317/LER-1980-007, Forwards LER 80-007/01T-0 | Forwards LER 80-007/01T-0 | |
| 05000317/LER-1980-008, Forwards LER 80-008/03L-0 | Forwards LER 80-008/03L-0 | |
| 05000317/LER-1980-008-03, /03L-0:on 800126,while Cooling Down for Scheduled Outage,Survey Technician Discovered Steam Blowing from 11A Reactor Coolant Pump.Sensing Line lPDT-123A Had through-wall Leak.Caused by Friction of Sensing Line W/Another Pipe | /03L-0:on 800126,while Cooling Down for Scheduled Outage,Survey Technician Discovered Steam Blowing from 11A Reactor Coolant Pump.Sensing Line lPDT-123A Had through-wall Leak.Caused by Friction of Sensing Line W/Another Pipe | |
| 05000318/LER-1980-008-03, /03L-0:on 800125,containment Spray Header 22 Was Isolated.Caused by Need to Repair Shutdown Heat Exchanger Inlet Cross Connect Valve.New Packing Installed | /03L-0:on 800125,containment Spray Header 22 Was Isolated.Caused by Need to Repair Shutdown Heat Exchanger Inlet Cross Connect Valve.New Packing Installed | |
| 05000318/LER-1980-008, Forwards LER 80-008/03L-0 | Forwards LER 80-008/03L-0 | |
| 05000318/LER-1980-009-03, /03L-0:on 800131,while Conducting Routine Test, Control Element Assembly (CEA) 32 Dropped Into Core.Cause Unknown.Technician Will Be Assigned During Next STP 0-29 to Monitor Operating Parameters of All CEAs on real-time Basi | /03L-0:on 800131,while Conducting Routine Test, Control Element Assembly (CEA) 32 Dropped Into Core.Cause Unknown.Technician Will Be Assigned During Next STP 0-29 to Monitor Operating Parameters of All CEAs on real-time Basis | |
| 05000318/LER-1980-009, Forwards LER 80-009/03L-0 | Forwards LER 80-009/03L-0 | |
| 05000317/LER-1980-009, Forwards LER 80-009/03L-0 | Forwards LER 80-009/03L-0 | |
| 05000317/LER-1980-009-03, /03L-0:on 800201,during Surveillance Testing, Discovered Hose for One of Two Containment Elevator Hose Stations Missing.Caused by Work Group Using Fire Sys for Cleaning Purposes on Elevation of Containment | /03L-0:on 800201,during Surveillance Testing, Discovered Hose for One of Two Containment Elevator Hose Stations Missing.Caused by Work Group Using Fire Sys for Cleaning Purposes on Elevation of Containment | |
| 05000318/LER-1980-010, Forwards LER 80-010/03L-0 | Forwards LER 80-010/03L-0 | |
| 05000318/LER-1980-010-03, /03L-0:on 800224,during Surveillance Testing, Control Element Assemblies 31 & 34 Dropped Into Core.Caused by Fault in Timer Module.Module Replaced | /03L-0:on 800224,during Surveillance Testing, Control Element Assemblies 31 & 34 Dropped Into Core.Caused by Fault in Timer Module.Module Replaced | |
| 05000318/LER-1980-011, Forwards Updated LER 80-011/01X-1 | Forwards Updated LER 80-011/01X-1 | |
| 05000318/LER-1980-011-01, Diesel Generator 21 Failed to Achieve 10-s Rated Speed,Rendering Low Pressure Safety Injection Pump 22 Inoperable.Caused by Slow Response of Diesel Generator Governor.Governor Replaced | Diesel Generator 21 Failed to Achieve 10-s Rated Speed,Rendering Low Pressure Safety Injection Pump 22 Inoperable.Caused by Slow Response of Diesel Generator Governor.Governor Replaced | |
| 05000317/LER-1980-011-03, W/Rcs at 130 Degrees & 250 Psia,Shutdown Cooling Suction Header Relief Lifted & Failed to Reset.Caused by Personnel Error.Valve Reset | W/Rcs at 130 Degrees & 250 Psia,Shutdown Cooling Suction Header Relief Lifted & Failed to Reset.Caused by Personnel Error.Valve Reset | |
| 05000317/LER-1980-011, Forwards Updated LER 80-011/03X-1 | Forwards Updated LER 80-011/03X-1 | |
| 05000317/LER-1980-012, Forwards LER 80-012/03L-0 | Forwards LER 80-012/03L-0 | |
| 05000317/LER-1980-012-03, /03L-0:on 800211,while Performing Routine Surveillance Test,Control Element Assembly (CEA) 35 Dropped Into Core.Cause Unknown.Technician Will Be Assigned to Monitor Operating Parameter of All CEAs During Next STP | /03L-0:on 800211,while Performing Routine Surveillance Test,Control Element Assembly (CEA) 35 Dropped Into Core.Cause Unknown.Technician Will Be Assigned to Monitor Operating Parameter of All CEAs During Next STP | |
| 05000318/LER-1980-012-03, /03L-0:on 800219,during Routine Surveillance,Small Leak Discovered on Charging Pump Common Suction Header Relief Valve.Caused by Vibration Induced Metal Fatigue in heat-affected Zone of Welded Penetration in Header | /03L-0:on 800219,during Routine Surveillance,Small Leak Discovered on Charging Pump Common Suction Header Relief Valve.Caused by Vibration Induced Metal Fatigue in heat-affected Zone of Welded Penetration in Header | |
| 05000318/LER-1980-012, Forwards LER 80-012/03L-0 | Forwards LER 80-012/03L-0 | |
| 05000318/LER-1980-013-03, /03L-0:on 800303,channel Zf Pressure Input Signal for Steam Generator Isolation 22 Was Bypassed.Caused by Signal Isolater 2-E/E-1023C Being Out of Calibr Due to Nonlinear Response | /03L-0:on 800303,channel Zf Pressure Input Signal for Steam Generator Isolation 22 Was Bypassed.Caused by Signal Isolater 2-E/E-1023C Being Out of Calibr Due to Nonlinear Response | |
| 05000318/LER-1980-013, Forwards LER 80-013/03L-0 | Forwards LER 80-013/03L-0 | |
| 05000317/LER-1980-013-03, During Surveillance Test, Channel D Containment High Pressure Setpoint Less Conservative than Tech Specs.Caused by Failed Signal Isolator 1-E/E-5313D.Instrument Returned for Repair | During Surveillance Test, Channel D Containment High Pressure Setpoint Less Conservative than Tech Specs.Caused by Failed Signal Isolator 1-E/E-5313D.Instrument Returned for Repair | |
| 05000317/LER-1980-013, Forwards Updated LER 80-013/03X-1 | Forwards Updated LER 80-013/03X-1 | |