Category:Response to Request for Additional Information (RAI)
MONTHYEARML24354A1312024-12-19019 December 2024 LLC, Response to NRC Request for Additional Information No. 032 (RAI-10297 R1) on the NuScale Standard Design Approval Application ML24354A2522024-12-19019 December 2024 Nuscale Power, LLC - Response to Request for Additional Information No. 032 (RAI-10297 Ri) on the Nuscale Standard Design Approval Application ML24353A2182024-12-18018 December 2024 LLC, Response to NRC Request for Additional Information No. 037 (RAI-10357 R1) on the NuScale Standard Design Approval Application ML24353A0292024-12-18018 December 2024 Nuscale Power LLC - Responses to NRC Request for Additional Information No. 011 (RAI-10111 Ri) on the Nuscale Standard Design Approval Application ML24353A2522024-12-18018 December 2024 LLC, Response to NRC Request for Additional Information No. 031 (RAI-10296 R1) on the NuScale Standard Design Approval Application ML24353A3332024-12-18018 December 2024 Nuscale Power, LLC - Response to NRC Request for Additional Information No. 037 (RAI-10357 Ri) on the Newscale Standard Design Approval Application ML24348A0632024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-44 ML24348A0072024-12-13013 December 2024 LLC Submittal of the NRCs Request for Docketing of Resolved Audit Responses ML24348A0522024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-36 ML24348A0272024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-23 ML24348A0872024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-68 ML24348A0432024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-30 ML24348A0812024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-59S2 ML24348A0332024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-26 ML24348A0672024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-44S ML24348A0732024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-57 ML24348A0292024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-24 ML24348A0202024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-8 ML24348A0692024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-45 ML24348A0582024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-39 ML24348A0702024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-49 ML24348A0122024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-5 ML24348A0452024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-33 ML24348A0622024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-43 ML24348A0612024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-41 ML24348A0142024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-5S ML24348A0542024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-37 ML24348A0752024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-58 ML24348A1132024-12-13013 December 2024 Nuscale Power, LLC - Response to NRC Request for Additional Information No. 037 (RAI-10357 R1) on the NuScale Standard Design Approval Application ML24348A0242024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-22 ML24348A0772024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-59 ML24327A1492024-11-22022 November 2024 LLC, Responses to NRC Request for Additional Information No. 024 (RAI-10185 R1) on the NuScale Standard Design Approval Application ML24326A1232024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.5.1-4 ML24326A1112024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.3.1-9 ML24326A1252024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.5.1-5 ML24326A1122024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.3.1-11 ML24326A3342024-11-21021 November 2024 Response to NuScale Topical Report Audit Question: A-LOCA.LTR-37 ML24326A3452024-11-21021 November 2024 Response to NuScale Topical Report Audit Question: A-LOCA.LTR-42 ML24326A3362024-11-21021 November 2024 Response to NuScale Topical Report Audit Question: A-LOCA.LTR-38 ML24326A0962024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16-14 ML24326A0942024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16-9 ML24326A0982024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.0.4-1 ML24326A0952024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16-13 ML24326A1352024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.6.3-2 ML24313A0662024-11-0808 November 2024 LLC - Response to NRC Request for Additional Information No. 015 (RAI-10133 R1) on the NuScale Standard Design Approval Application ML24313A1212024-11-0808 November 2024 LLC - Response to NRC Request for Additional Information No. 020 (RAI-10150 R1) on the NuScale Standard Design Approval Application ML24313A0522024-11-0808 November 2024 LLC Response to NRC Request for Additional Information No. 14 (RAI-10131 R1) on the NuScale Standard Design Approval Application ML24281A0202024-10-0707 October 2024 LLC, Response to NRC Request for Additional Information No. 023 (RAI-10177 R1) on the NuScale Standard Design Approval Application ML24281A0182024-10-0707 October 2024 LLC, Response to NRC Request for Additional Information No. 017 (RAI-10135 R1) on the NuScale Standard Design Approval Application ML24271A2822024-09-27027 September 2024 LLC - Response to NRC Request for Additional Information No.026 (RAI-10199 R1) on the NuScale Standard Design Approval Application 2024-09-27
[Table view] |
Text
NuScale Nonproprietary NuScale Nonproprietary Response to SDAA Audit Question Question Number: A-3.9.4-2 Receipt Date: 04/10/2023 Question:
During the Advisory Committee on Reactor Safeguards subcommittee meeting for the NuScale Design Certification Application on April 17, 2019 (ADAMS Accession No. ML19114A107),
several members inquired about unique environmental conditions for the control rod drive mechanisms (CRDMs), which are very similar in configuration to those in existing PWRs, but operate in different environmental conditions. While there is operating experience with existing PWR CRDMs, the CRDMs typically operate in a water solid environment, so NuScales unique design, where the mechanisms operate in a borated steam environment and are cooled by cooling coils, introduces additional uncertainties. Specifically, a member of the Advisory Committee inquired about the potential for chemical buildup to form from substances evaporating off the top of the PZR water level and whether this buildup would prevent the rod from inserting into the core. Significant accumulation of particulates such as boric acid crystals around the movable elements of the CRDM latch mechanism could inhibit the ability of the latches to release the CRD shafts and scram the reactor. This accumulation could affect multiple CRDMs and could lead to a common-cause failure of some or all CRDMs. The NRC staff had requested assurance from the DCA applicant that accumulation of boric acid crystals would not adversely impact the ability of the CRDMs to perform their safety-related function of inserting the control rods. The DCA applicant had provided a response that it had considered the phenomenon in the design process but did not consider it to adversely impact the ability of the CRDMs to drop the control rods. For the US460 design, the general operating environment (e.g., a borated steam environment and external cooling system for the CRDMs) remains similar to the design reviewed under the Design Certification, but the new design may have introduced additional susceptibilities to this previously identified phenomenon. Therefore, the staff requests additional information to confirm that this phenomenon would not adversely impact the ability of the CRDMs to drop the control rods for the US460 design. This information is necessary to confirm the design meets the requirements of GDC 26, 27, and 29.
NuScale Nonproprietary NuScale Nonproprietary
Response
NuScales response provided during DCA review in NRC Request for Additional Information RAI No. 9691, Question 03.09.04-13 (ADAMS Accession No. ML19200A208) and the NRCs subsequent evaluation of it in FSER Section 3.9.4.4.6 (see ADAMS Accession No. ML20205L405) remain applicable in principle.
The primary components of the CRDM, as relates to the possibility of adverse functional impacts caused by boric acid crystallization buildup, remain essentially unchanged, as can be determined upon comparison of DCA and SDAA Figures 4.6-1 through 4.6-3. The notable difference in CRDM designs is the method that the electromagnetic drive coils are cooled. In the US720 design a forced-water heat exchanger was implemented, whereas the US460 configuration uses a cooling jacket that acts as a cooling tank driven by natural circulation. This difference in coil cooling method is inconsequential to the DCA review discussions and the resulting conclusion that this phenomenon is not expected to occur.
No changes to the SDAA are necessary.