Response to SDAA Audit Question A-12-1
ML23205A227
Person / Time
Site: 99902078, 05200050
Issue date: 07/24/2023
From:
NuScale
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23205A216 List:
References
LO-146777
Download: ML23205A227 (1)


Text

NuScale Nonproprietary NuScale Nonproprietary Response to SDAA Audit Question Question Number: A-12-1 Receipt Date: 04/10/2023 Question:

This item is regarding the RG 1.143 classification of the Radioactive Waste Building (RWB) structure (not the systems or components within the RWB).

NuScale Design Specific Review Standard (DSRS), Sections 12.3-12.4 and Chapter 11, indicate that structures housing radioactive waste processing systems and components should be classified using the guidance of RG 1.143.

The RG 1.143 classification for portions of the radwaste building is unclear. In several places in the application, such as Section 3.8.4.1.3, it indicates that a small portion of the above grade structure, such as areas used for waste sorting and storage, and the entirety of the below grade portion of the RWB is classified as RG 1.143 classification RW-IIa. Table 3.2-1, specifies that the Below-grade structure (areas designated for storage or processing of radioactive waste) is RW-IIa and that the above-grade structure is Seismic Category III. Please clarify the following:

1.

Is the entirety of the below grade portions of the RWB classified RW-IIa? If so, please correct Table 3.2-1.

2.

Which portions of the RWB are considered below grade? Is the entirety of the 82 Elevation on the plant figures considered below grade? The portions of the RWB that are above and below grade should be clearly defined.

3.

As discussed above, several places in the application indicate that a small portion of the RWB structure above grade is classified as RW-IIa. Please clarify which above grade rooms or areas are RW-IIa and which are Seismic Category III.

NuScale Nonproprietary NuScale Nonproprietary

Response

The portion of the Radwaste Building (RWB) that is below grade elevation (below 100 Elevation level) is classified as a RW-IIa structure. The above-grade portion of the building is a steel-framed Seismic Category III (SC-III) structure with the exception of an RW-IIa isolated enclosure used for waste sorting and storage. Rooms 225, 226 and 227, as depicted in Figure 1.2-24, at the 100 elevation, are RW-IIa. Other areas at the 100 elevation level, and areas above 100 elevation level, are considered SC-III. Areas below grade are RW-IIa. Table 3.2-1 in the SDA has been revised to reflect the above-stated information.

Markups of the affected changes, as described in the response, are provided below:

NuScale Final Safety Analysis Report Classification of Structures, Systems, and Components NuScale US460 SDAA 3.2-7 Draft Revision 1 Audit Issue A-12-2 Table 3.2-1: Seismic Classification of Building Structures Structure Seismic Category Reactor Building (RXB)

  • Majority of the building is SC-I, but several areas of the building are classified as SC-II (Note 1)

I/II Turbine Building III Control Building (CRB)

  • Area housing the main control room and associated facilities I

CRB

  • Portions of the building where protection of SC-I areas is required II CRB
  • Areas not classified as SC-I or SC-II (Note 1)

III Annex Building III Firewater Building III Diesel Generator Building III Radioactive Waste Building

  • Above-grade structure III Radioactive Waste Building
  • Below-grade structure (and areas above grade designated for storage or processing of radioactive waste (Section 3.8.4.1.3))

RW-IIa Central Utility Building III Site Plant Cooling Water Chem Feed Building III Site Utility Racks III Note 1: Seismic Classification for RXB and CRB are discussed in Section 3.7.2.