|
---|
Category:OPERATING LICENSES-APPLIATION TO AMEND-RENEW EXISTING
MONTHYEARNPL-99-0565, TS Change Request 201 to Licenses DPR-24 & DPR-27,revising Tech Specs 15.3.1.A.3,15.3.3..A & 15.3.3.C for Consistency1999-10-0505 October 1999 TS Change Request 201 to Licenses DPR-24 & DPR-27,revising Tech Specs 15.3.1.A.3,15.3.3..A & 15.3.3.C for Consistency NPL-99-0446, Application for Amends to Licenses DPR-24 & DPR-27,removing Word Plasma from TS 15.3.5 Re Discussion of Type of Display Monitor for sub-cooling Info in CR & Removing Discussion from TS 15.3.7 Re EDG Inoperability1999-08-0404 August 1999 Application for Amends to Licenses DPR-24 & DPR-27,removing Word Plasma from TS 15.3.5 Re Discussion of Type of Display Monitor for sub-cooling Info in CR & Removing Discussion from TS 15.3.7 Re EDG Inoperability NPL-99-0405, Suppl 2 to TS Change Request 211,transmitting Text That Will Be Relocated to Pbnp FSAR with Respect to Manager Supervisory Staff Requirements.Suppl Provided Based on Comments Fromqa Branch of NRC1999-07-15015 July 1999 Suppl 2 to TS Change Request 211,transmitting Text That Will Be Relocated to Pbnp FSAR with Respect to Manager Supervisory Staff Requirements.Suppl Provided Based on Comments Fromqa Branch of NRC NPL-99-0386, Application for Amends to Licenses DPR-24 & DPR-27, Respectively,Removing Ifba Enrichment Curve Methodology1999-07-0101 July 1999 Application for Amends to Licenses DPR-24 & DPR-27, Respectively,Removing Ifba Enrichment Curve Methodology NPL-99-0369, Application for Amends to Licenses DPR-24 & DPR-27 to Reflect Required Changes to TS as Result of Using Upgraded Fuel at plant.Non-proprietary,WCAP-14788 & Proprietary WCAP- WCAP-14787 Repts Encl.Proprietary Rept Withheld1999-06-22022 June 1999 Application for Amends to Licenses DPR-24 & DPR-27 to Reflect Required Changes to TS as Result of Using Upgraded Fuel at plant.Non-proprietary,WCAP-14788 & Proprietary WCAP- WCAP-14787 Repts Encl.Proprietary Rept Withheld NPL-99-0337, to TS Change Request 211,reflecting Administrative Changes in Sections 15.6 & 15.7 by Changing Titles,Increasing Min Operating Crew Shift Staffing & Deleting Duty & Call Superintendent Function1999-06-0909 June 1999 to TS Change Request 211,reflecting Administrative Changes in Sections 15.6 & 15.7 by Changing Titles,Increasing Min Operating Crew Shift Staffing & Deleting Duty & Call Superintendent Function NPL-99-0206, TS Change Request 212 to Licenses DPR-24 & DPR-27,updating References in TS to Reflect Relocation of Referenced Info in UFSAR1999-04-12012 April 1999 TS Change Request 212 to Licenses DPR-24 & DPR-27,updating References in TS to Reflect Relocation of Referenced Info in UFSAR NPL-99-0057, Application for Amends to Licenses DPR-24 & DPR-27,revising TS 15.6 & 15.7 to Reflect Proposed Administrative Control Changes1999-01-29029 January 1999 Application for Amends to Licenses DPR-24 & DPR-27,revising TS 15.6 & 15.7 to Reflect Proposed Administrative Control Changes NPL-98-0766, Application for Amends to Licenses DPR-24 & DPR-27,revising TS to Ensure 4 Kv Bus Undervoltage Input to Reactor Trip Is Controlled IAW Design & Licensing Basis for Facility1998-10-0707 October 1998 Application for Amends to Licenses DPR-24 & DPR-27,revising TS to Ensure 4 Kv Bus Undervoltage Input to Reactor Trip Is Controlled IAW Design & Licensing Basis for Facility NPL-98-0586, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Section 15.4.1 by Removing Requirement to Check Environ Monitors on Monthly Basis1998-10-0505 October 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Section 15.4.1 by Removing Requirement to Check Environ Monitors on Monthly Basis NPL-98-0768, Application for Amends to Licenses DPR-24 & DPR-27,adding Notation Definition Contained in TS Table 15.4.1-1, Min Frequencies for Checks,Calibrations & Tests of Instrument Channels, Per NUREG-14311998-09-28028 September 1998 Application for Amends to Licenses DPR-24 & DPR-27,adding Notation Definition Contained in TS Table 15.4.1-1, Min Frequencies for Checks,Calibrations & Tests of Instrument Channels, Per NUREG-1431 NPL-98-0759, Tech Spec Change Request 209,amending Licenses DPR-24 & DPR-27,removing Explicit Testing Requirements of TS Section 15.4.13, Shock Suppressors (Snubbers).'1998-09-23023 September 1998 Tech Spec Change Request 209,amending Licenses DPR-24 & DPR-27,removing Explicit Testing Requirements of TS Section 15.4.13, Shock Suppressors (Snubbers).' L-98-613, Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability1998-07-30030 July 1998 Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability NPL-98-0613, Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability1998-07-30030 July 1998 Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability NPL-98-0431, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl1998-05-28028 May 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl L-98-431, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl1998-05-28028 May 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl NPL-98-0303, TS Change 205 to License DPR-27,revising Schedule for Implementing Boron Concentration Changes Related to Planned Conversion of Unit 2 to 18-month Fuel Cycles1998-05-15015 May 1998 TS Change 205 to License DPR-27,revising Schedule for Implementing Boron Concentration Changes Related to Planned Conversion of Unit 2 to 18-month Fuel Cycles NPL-98-0146, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Sections 15.3.6, Containment Sys Bases, 15.3.12, CR Emergency Filtration Including bases,15.4.4, Containment Tests bases,15.4.11, CR Emergency...1998-02-26026 February 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Sections 15.3.6, Containment Sys Bases, 15.3.12, CR Emergency Filtration Including bases,15.4.4, Containment Tests bases,15.4.11, CR Emergency... NPL-97-0484, TS Change Request 199,consisting of Application for Amends to Licenses DPR-24 & DPR-27,removing Requirement in TS to Perform Containment Integrated Leak Rate 60-months from Previous Test1997-08-14014 August 1997 TS Change Request 199,consisting of Application for Amends to Licenses DPR-24 & DPR-27,removing Requirement in TS to Perform Containment Integrated Leak Rate 60-months from Previous Test NPL-97-0315, Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 11997-06-0303 June 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 1 NPL-97-0249, Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 11997-05-0909 May 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 1 NPL-97-0166, Application for Amends to Licenses DPR-24 & DPR-27,changing Title of Corporate Officer Responsible for Nuclear Operations from Vice President-Nuclear Power, to Chief Nuclear Officer Per TS Section 15.6.2.1.c1997-04-14014 April 1997 Application for Amends to Licenses DPR-24 & DPR-27,changing Title of Corporate Officer Responsible for Nuclear Operations from Vice President-Nuclear Power, to Chief Nuclear Officer Per TS Section 15.6.2.1.c NPL-97-0167, Application for Amends to Licenses DPR-24 & DPR-27, Eliminating Provisions for Operation of Units at Below 3.5% Rated Power W/Only One RCP1997-04-14014 April 1997 Application for Amends to Licenses DPR-24 & DPR-27, Eliminating Provisions for Operation of Units at Below 3.5% Rated Power W/Only One RCP ML20138M4951997-02-13013 February 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray, to Incorporate Outage Times Similar to NUREG-1431,Rev 1 ML20134L9621997-02-12012 February 1997 TS Change Request 196 to Licenses DPR-24 & DPR-27, Respectively,Relocating Turbine Overspeed Protection Surveillances,Limiting Conditions for Operation (Lcos),Per NRC GL 95-10 ML20134A3581997-01-24024 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting Storage of Fuel Assemblies of Higher Enrichment than Currently Authorized ML20134A3061997-01-21021 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting to Update References to 10CFR20 in TS Section 15.6.11, Radiation Protection Program ML20133N3961997-01-16016 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting Boron Concentration Changes to Support 18-month Fuel Cycles ML20132C3631996-12-12012 December 1996 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Auxiliary Cooling Sys,Air Recirculation Fan Coolers & Containment Spray, Per NUREG-1431,Rev 1 ML20129F1591996-09-30030 September 1996 Application for Amends to Licenses DPR-24 & DPR-27 for Plant,Units 1 & 2 to Modify TS Section 15.3.3, ECCS, Auxiliary Cooling Sys,Air Recirculation Fan Coolers & Containment Spray, to Incorporate AOT ML20129C0651996-09-19019 September 1996 Application for Amends to Licenses DPR-24 & DPR-27,revising Seection 15.3.15, Overpressure Mitigating Sys & Section 15.3.1, Rcs. Calculation 96-0182,Rev 1 Which Determined Acceptable LTOP Setpoint for Plant,Encl ML20117D2571996-08-22022 August 1996 TS Change Request 190 to Licenses DPR-24 & DPR-27,reflecting Licensed Power Level for Plant ML20116N1311996-08-15015 August 1996 Application for Amends to Licenses DPR-24 & DPR-27, Supplementing TS Change Request 170,modifying TS 15.3.10, Control Rod & Power Distribution Limits & TS 15.4.1 Operational Safety Review ML20117K1831996-06-0404 June 1996 TS Change Request 189 to Licenses DPR-24 & DPR-27,modifying TS to Maintain Safety Margin for Unit 2 W/Replacement Sgs. Util Scheduled to Replace SGs in Unit 2 During Fall 1996 Refueling Outage ML20112F7291996-06-0404 June 1996 TS Change Request 188 to Licenses DPR-24 & DPR-27,modifying TS 15.2.3, Limiting Safety Sys Settings & Protective Instrumentation & 15.5.3, Design Features - Reactor ML20112E2191996-05-29029 May 1996 Application for Amends to Licenses DPR-24 & DPR-27,revising Section 15.4.4,Containment Tests,Section 15.1, Definitions, 15.3.6, Containment System, & 15.6, Administrative Controls ML20108D1461996-04-29029 April 1996 TS Change Request 173 to Application for Amends to Licenses DPR-24 & DPR-27,respectively,removing Fire Protection Requirements from TSs & Incorporating Requirements Into Fire Protection Evaluation Rept,Per GL 88-12 ML20107N1951996-04-24024 April 1996 Application for Amends to Licenses DPR-24 & DPR-27,removing Items Identified in GLs 89-01 & 95-10 as Being Procedural Details from Pbnp Rets,Section 15.7 & Relocating to Appropriate Documents ML20100L3791996-02-27027 February 1996 Application for Amends to Licenses DPR-24 & DPR-27, Respectively,Consisting of TS Change 186,modifying TS Section 15.4.4, Containment Tests, Spec I.C.1 to State That Type a Tests Be Conducted Per 10CFR50,App J ML20097D6691996-02-0808 February 1996 Application for Amends to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 170,modifying TS 15.3.10, Control Rod & Power Distribution Limits & TS 15.4.1, Operational Safety Review ML20095F7521995-12-13013 December 1995 Application for Amends to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 185 Revising TS to Implement COLR in Accordance W/Gl 88-16, Removal of Cycle-Specific Parameter Limits... & WCAP-14483, ...Expanded Colr ML20094R5061995-11-29029 November 1995 Application for Amends to Licenses DPR-24 & DPR-27 Consisting of Suppl to Change Request 180,modifying 4.16 Kv Degraded voltage,4.16 Kv Loss of Voltage & 480 V Loss of Voltage Protection Functions Setting Limits ML20094M9721995-11-17017 November 1995 Application for Amends to Licenses DPR-24 & DPR-27,revising Health Physics Manager Qualifications ML20094H4811995-11-0909 November 1995 TS Change Request 184 to Licenses DPR-24 & DPR-27,modifying TS Section 15.4.2, ISI & Testing of Safety Class Components, to Incorporate F* SG Tube Repair Criterion. Proprietary B&W Rept Encl.Proprietary B&W Rept Withheld ML20094D3041995-10-23023 October 1995 Application for Amends to Licenses DPR-24 & DPR-27,changing Licensee Name to Wisconsin Energy Co (Wec),In Support of Pending Merger Between NSP & WEC ML20093K1091995-10-19019 October 1995 Application for Amend to Licenses DPR-24 & DPR-27,revising Modified TS 15.3.1.G, Operational Limitation, Spec 3.b,to Reduce RCS Raw Measured Total Flow Rate Limit by 4000 Gpm for Unit 2 ML20092H0071995-09-13013 September 1995 Application for Amend to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 181,revising TS Section 15.3.1.G.3 Re RCS Raw Measured Total Flow Rate.W/O TS ML20085N6961995-06-23023 June 1995 Application for Amend to Licenses DPR-24 & DPR-27,consisting of Change Request 164,modifying TS 15.3.0, General Considerations, to Incorporate Requirements Similar to NUREG-1431 ML20083B0051995-05-0202 May 1995 Application for Amends to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 172,modifying TS Section 15.4.1, Operational Safety Review ML20082R8761995-04-27027 April 1995 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Section 15.3.5, Instrumentation Sys 1999-08-04
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARNPL-99-0565, TS Change Request 201 to Licenses DPR-24 & DPR-27,revising Tech Specs 15.3.1.A.3,15.3.3..A & 15.3.3.C for Consistency1999-10-0505 October 1999 TS Change Request 201 to Licenses DPR-24 & DPR-27,revising Tech Specs 15.3.1.A.3,15.3.3..A & 15.3.3.C for Consistency NPL-99-0446, Application for Amends to Licenses DPR-24 & DPR-27,removing Word Plasma from TS 15.3.5 Re Discussion of Type of Display Monitor for sub-cooling Info in CR & Removing Discussion from TS 15.3.7 Re EDG Inoperability1999-08-0404 August 1999 Application for Amends to Licenses DPR-24 & DPR-27,removing Word Plasma from TS 15.3.5 Re Discussion of Type of Display Monitor for sub-cooling Info in CR & Removing Discussion from TS 15.3.7 Re EDG Inoperability NPL-99-0405, Suppl 2 to TS Change Request 211,transmitting Text That Will Be Relocated to Pbnp FSAR with Respect to Manager Supervisory Staff Requirements.Suppl Provided Based on Comments Fromqa Branch of NRC1999-07-15015 July 1999 Suppl 2 to TS Change Request 211,transmitting Text That Will Be Relocated to Pbnp FSAR with Respect to Manager Supervisory Staff Requirements.Suppl Provided Based on Comments Fromqa Branch of NRC NPL-99-0386, Application for Amends to Licenses DPR-24 & DPR-27, Respectively,Removing Ifba Enrichment Curve Methodology1999-07-0101 July 1999 Application for Amends to Licenses DPR-24 & DPR-27, Respectively,Removing Ifba Enrichment Curve Methodology NPL-99-0369, Application for Amends to Licenses DPR-24 & DPR-27 to Reflect Required Changes to TS as Result of Using Upgraded Fuel at plant.Non-proprietary,WCAP-14788 & Proprietary WCAP- WCAP-14787 Repts Encl.Proprietary Rept Withheld1999-06-22022 June 1999 Application for Amends to Licenses DPR-24 & DPR-27 to Reflect Required Changes to TS as Result of Using Upgraded Fuel at plant.Non-proprietary,WCAP-14788 & Proprietary WCAP- WCAP-14787 Repts Encl.Proprietary Rept Withheld NPL-99-0337, to TS Change Request 211,reflecting Administrative Changes in Sections 15.6 & 15.7 by Changing Titles,Increasing Min Operating Crew Shift Staffing & Deleting Duty & Call Superintendent Function1999-06-0909 June 1999 to TS Change Request 211,reflecting Administrative Changes in Sections 15.6 & 15.7 by Changing Titles,Increasing Min Operating Crew Shift Staffing & Deleting Duty & Call Superintendent Function NPL-99-0206, TS Change Request 212 to Licenses DPR-24 & DPR-27,updating References in TS to Reflect Relocation of Referenced Info in UFSAR1999-04-12012 April 1999 TS Change Request 212 to Licenses DPR-24 & DPR-27,updating References in TS to Reflect Relocation of Referenced Info in UFSAR NPL-99-0057, Application for Amends to Licenses DPR-24 & DPR-27,revising TS 15.6 & 15.7 to Reflect Proposed Administrative Control Changes1999-01-29029 January 1999 Application for Amends to Licenses DPR-24 & DPR-27,revising TS 15.6 & 15.7 to Reflect Proposed Administrative Control Changes NPL-98-0766, Application for Amends to Licenses DPR-24 & DPR-27,revising TS to Ensure 4 Kv Bus Undervoltage Input to Reactor Trip Is Controlled IAW Design & Licensing Basis for Facility1998-10-0707 October 1998 Application for Amends to Licenses DPR-24 & DPR-27,revising TS to Ensure 4 Kv Bus Undervoltage Input to Reactor Trip Is Controlled IAW Design & Licensing Basis for Facility NPL-98-0586, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Section 15.4.1 by Removing Requirement to Check Environ Monitors on Monthly Basis1998-10-0505 October 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Section 15.4.1 by Removing Requirement to Check Environ Monitors on Monthly Basis NPL-98-0768, Application for Amends to Licenses DPR-24 & DPR-27,adding Notation Definition Contained in TS Table 15.4.1-1, Min Frequencies for Checks,Calibrations & Tests of Instrument Channels, Per NUREG-14311998-09-28028 September 1998 Application for Amends to Licenses DPR-24 & DPR-27,adding Notation Definition Contained in TS Table 15.4.1-1, Min Frequencies for Checks,Calibrations & Tests of Instrument Channels, Per NUREG-1431 NPL-98-0759, Tech Spec Change Request 209,amending Licenses DPR-24 & DPR-27,removing Explicit Testing Requirements of TS Section 15.4.13, Shock Suppressors (Snubbers).'1998-09-23023 September 1998 Tech Spec Change Request 209,amending Licenses DPR-24 & DPR-27,removing Explicit Testing Requirements of TS Section 15.4.13, Shock Suppressors (Snubbers).' L-98-613, Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability1998-07-30030 July 1998 Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability NPL-98-0613, Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability1998-07-30030 July 1998 Application for Amends to Licenses DPR-24 & DPR-27, Incorporating Changes to TSs to More Clearly Define Requirements for Svc Water Sys Operability NPL-98-0431, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl1998-05-28028 May 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl L-98-431, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl1998-05-28028 May 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS to Provide Specific Numerical Setting for Rt,Rcp Trip & AFW Initiation on Loss of Power to 4 Kv Buses.Rev 1 to Calculation 9334281-01 Re RCP Internal Voltage Decay,Encl NPL-98-0303, TS Change 205 to License DPR-27,revising Schedule for Implementing Boron Concentration Changes Related to Planned Conversion of Unit 2 to 18-month Fuel Cycles1998-05-15015 May 1998 TS Change 205 to License DPR-27,revising Schedule for Implementing Boron Concentration Changes Related to Planned Conversion of Unit 2 to 18-month Fuel Cycles NPL-98-0146, Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Sections 15.3.6, Containment Sys Bases, 15.3.12, CR Emergency Filtration Including bases,15.4.4, Containment Tests bases,15.4.11, CR Emergency...1998-02-26026 February 1998 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Sections 15.3.6, Containment Sys Bases, 15.3.12, CR Emergency Filtration Including bases,15.4.4, Containment Tests bases,15.4.11, CR Emergency... NPL-97-0484, TS Change Request 199,consisting of Application for Amends to Licenses DPR-24 & DPR-27,removing Requirement in TS to Perform Containment Integrated Leak Rate 60-months from Previous Test1997-08-14014 August 1997 TS Change Request 199,consisting of Application for Amends to Licenses DPR-24 & DPR-27,removing Requirement in TS to Perform Containment Integrated Leak Rate 60-months from Previous Test NPL-97-0315, Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 11997-06-0303 June 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 1 NPL-97-0249, Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 11997-05-0909 May 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray to Incorporate Allowed Outage Times Similar to Those Contained in NUREG-1431,Rev 1 NPL-97-0166, Application for Amends to Licenses DPR-24 & DPR-27,changing Title of Corporate Officer Responsible for Nuclear Operations from Vice President-Nuclear Power, to Chief Nuclear Officer Per TS Section 15.6.2.1.c1997-04-14014 April 1997 Application for Amends to Licenses DPR-24 & DPR-27,changing Title of Corporate Officer Responsible for Nuclear Operations from Vice President-Nuclear Power, to Chief Nuclear Officer Per TS Section 15.6.2.1.c NPL-97-0167, Application for Amends to Licenses DPR-24 & DPR-27, Eliminating Provisions for Operation of Units at Below 3.5% Rated Power W/Only One RCP1997-04-14014 April 1997 Application for Amends to Licenses DPR-24 & DPR-27, Eliminating Provisions for Operation of Units at Below 3.5% Rated Power W/Only One RCP ML20138M4951997-02-13013 February 1997 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Acs,Air Recirculation Fan Coolers & Containment Spray, to Incorporate Outage Times Similar to NUREG-1431,Rev 1 ML20134L9621997-02-12012 February 1997 TS Change Request 196 to Licenses DPR-24 & DPR-27, Respectively,Relocating Turbine Overspeed Protection Surveillances,Limiting Conditions for Operation (Lcos),Per NRC GL 95-10 ML20134A3581997-01-24024 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting Storage of Fuel Assemblies of Higher Enrichment than Currently Authorized ML20134A3061997-01-21021 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting to Update References to 10CFR20 in TS Section 15.6.11, Radiation Protection Program ML20133N3961997-01-16016 January 1997 Application for Amends to Licenses DPR-24 & DPR-27, Requesting Boron Concentration Changes to Support 18-month Fuel Cycles ML20132C3631996-12-12012 December 1996 Suppl to TS Change Request 192 to Licenses DPR-24 & DPR-27, Modifying TS Section 15.3.3, Eccs,Auxiliary Cooling Sys,Air Recirculation Fan Coolers & Containment Spray, Per NUREG-1431,Rev 1 ML20129F1591996-09-30030 September 1996 Application for Amends to Licenses DPR-24 & DPR-27 for Plant,Units 1 & 2 to Modify TS Section 15.3.3, ECCS, Auxiliary Cooling Sys,Air Recirculation Fan Coolers & Containment Spray, to Incorporate AOT ML20129C0651996-09-19019 September 1996 Application for Amends to Licenses DPR-24 & DPR-27,revising Seection 15.3.15, Overpressure Mitigating Sys & Section 15.3.1, Rcs. Calculation 96-0182,Rev 1 Which Determined Acceptable LTOP Setpoint for Plant,Encl ML20117D2571996-08-22022 August 1996 TS Change Request 190 to Licenses DPR-24 & DPR-27,reflecting Licensed Power Level for Plant ML20116N1311996-08-15015 August 1996 Application for Amends to Licenses DPR-24 & DPR-27, Supplementing TS Change Request 170,modifying TS 15.3.10, Control Rod & Power Distribution Limits & TS 15.4.1 Operational Safety Review ML20117K1831996-06-0404 June 1996 TS Change Request 189 to Licenses DPR-24 & DPR-27,modifying TS to Maintain Safety Margin for Unit 2 W/Replacement Sgs. Util Scheduled to Replace SGs in Unit 2 During Fall 1996 Refueling Outage ML20112F7291996-06-0404 June 1996 TS Change Request 188 to Licenses DPR-24 & DPR-27,modifying TS 15.2.3, Limiting Safety Sys Settings & Protective Instrumentation & 15.5.3, Design Features - Reactor ML20112E2191996-05-29029 May 1996 Application for Amends to Licenses DPR-24 & DPR-27,revising Section 15.4.4,Containment Tests,Section 15.1, Definitions, 15.3.6, Containment System, & 15.6, Administrative Controls ML20108D1461996-04-29029 April 1996 TS Change Request 173 to Application for Amends to Licenses DPR-24 & DPR-27,respectively,removing Fire Protection Requirements from TSs & Incorporating Requirements Into Fire Protection Evaluation Rept,Per GL 88-12 ML20107N1951996-04-24024 April 1996 Application for Amends to Licenses DPR-24 & DPR-27,removing Items Identified in GLs 89-01 & 95-10 as Being Procedural Details from Pbnp Rets,Section 15.7 & Relocating to Appropriate Documents ML20100L3791996-02-27027 February 1996 Application for Amends to Licenses DPR-24 & DPR-27, Respectively,Consisting of TS Change 186,modifying TS Section 15.4.4, Containment Tests, Spec I.C.1 to State That Type a Tests Be Conducted Per 10CFR50,App J ML20097D6691996-02-0808 February 1996 Application for Amends to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 170,modifying TS 15.3.10, Control Rod & Power Distribution Limits & TS 15.4.1, Operational Safety Review ML20095F7521995-12-13013 December 1995 Application for Amends to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 185 Revising TS to Implement COLR in Accordance W/Gl 88-16, Removal of Cycle-Specific Parameter Limits... & WCAP-14483, ...Expanded Colr ML20094R5061995-11-29029 November 1995 Application for Amends to Licenses DPR-24 & DPR-27 Consisting of Suppl to Change Request 180,modifying 4.16 Kv Degraded voltage,4.16 Kv Loss of Voltage & 480 V Loss of Voltage Protection Functions Setting Limits ML20094M9721995-11-17017 November 1995 Application for Amends to Licenses DPR-24 & DPR-27,revising Health Physics Manager Qualifications ML20094H4811995-11-0909 November 1995 TS Change Request 184 to Licenses DPR-24 & DPR-27,modifying TS Section 15.4.2, ISI & Testing of Safety Class Components, to Incorporate F* SG Tube Repair Criterion. Proprietary B&W Rept Encl.Proprietary B&W Rept Withheld ML20094D3041995-10-23023 October 1995 Application for Amends to Licenses DPR-24 & DPR-27,changing Licensee Name to Wisconsin Energy Co (Wec),In Support of Pending Merger Between NSP & WEC ML20093K1091995-10-19019 October 1995 Application for Amend to Licenses DPR-24 & DPR-27,revising Modified TS 15.3.1.G, Operational Limitation, Spec 3.b,to Reduce RCS Raw Measured Total Flow Rate Limit by 4000 Gpm for Unit 2 ML20092H0071995-09-13013 September 1995 Application for Amend to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 181,revising TS Section 15.3.1.G.3 Re RCS Raw Measured Total Flow Rate.W/O TS ML20085N6961995-06-23023 June 1995 Application for Amend to Licenses DPR-24 & DPR-27,consisting of Change Request 164,modifying TS 15.3.0, General Considerations, to Incorporate Requirements Similar to NUREG-1431 ML20083B0051995-05-0202 May 1995 Application for Amends to Licenses DPR-24 & DPR-27, Consisting of TS Change Request 172,modifying TS Section 15.4.1, Operational Safety Review ML20082R8761995-04-27027 April 1995 Application for Amends to Licenses DPR-24 & DPR-27,modifying TS Section 15.3.5, Instrumentation Sys 1999-08-04
[Table view] |
Text
. . = _ _
Wisconsin Electnc POWER COMPANY 231 W Michgan PO Box 2046 Mdwoukee.WI 53201-2046 (414)221 2345
. VPNPD-96-108 10 CFR 50.4 10 CFR 50.90 December 12,1996 Document Control Desk US NUCLEAR REGULATORY COMMISSION l Mail Station Pl-137 Washington, DC 20555 Ladies / Gentlemen: ,
DOCKETS 50-266 AND 50-301 SUPPLEMENT TO TECHNICAL SPECIFICATIONS CHANGE REOUEST 192 EQINT BEACH NUCLEAR PLANT. UNITS 1 AND 2 In a letter dated September 30,1996, Wisconsin Electric requested Technical Specifications change request 192. This Technical Specifications change request proposes to modify Technical Specifications i Section 15.3.3, " Emergency Core Cooling System, Amuliary Cooling Systems, Air Recirculation Fan Coolers, and Containment Spray" to incorporate allowed outage times similar to those contained in NUREG-1431, Revision 1, " Westinghouse Owner's Group Improved Standard Technical Specifications,"
and modify the operability requirements for the service water system. The proposed changes to Technical Specifications Section 15.3.7, " Auxiliary Electrical Systems," also reflect the modified service water operability requirements. The proposed change to Technical Specifications Section 15.5.2,"Contain-ment," modifies the heat removal capacity of the reactor containment air cooler units. A supplement to this Technical Specifications change request was provided in a letter dated November 13,1996.
This letter also provides supplemental information for Technical Specifications change request 192. The attached supplement proposes to modify the proposed Technical Specifications changes as follows-1 l 1. Change TS 15.3.3.C to require four operable component cooling water pumps for two unit operation.
The current requirement is three component cooling water pumps for two unit operation. Addi-
/
tionally, the allowed outage time for one component cooling water pump is being changed from 24 '
/'
( to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The net effect of these two changes is a substantial improvement from the existing CCW Technical Specifications, because previously one of the four pumps could have been inoperable pl ,
indefinitely without limitation. I
- 2. Modify the proposed TS 15.3.3.D.2.d to require 5 operable service water pumps for entry into this limiting condition for operation instead of the originally proposed requirement of four service water j pumps. This change provides added assurance that sufficient service water flow will be available for :
all necessary equipment if the containment fan cooler outlet motor operated valves are open in both j s y _ units during an accident. :
'9612180301 961212 PDR ADOCK 05000266 P PDR u g g g,m e, g ,
I
. - - - .~ -- - - . . - . - - .. _- - . .-- -.-- . - -
Document Control Desk December 12,1996 '
Page 2
- 3. The proposed removal of the containment cooling capability statement in the basis of Te:hnical !
Specifications Section_15.3.3 is not needed. The capability statement was being removed from the Technical Specifications basis because it does not directly support any of the operability requirements or LCOs for the containment cooling systems. This statement is being left in the basis in recognition that this capability always was and still is available.
We have determined that the additional information does not involve a significant hazards consideration, authorize a significant change in the types or total amounts of any effluent release, or result in any .
significant increase in individual or cumulative occupational exposure. Therefore, we conclude that the !
proposed amendments meet the requirements of 10 CFR 51.22(c)(9) and that an environmental impact statement or negative declaration and environmental impact appraisal need not be prepared. The original i "No Significant Hazards" determinations for operation under the proposed Technical Specifications remain applicable.
We have found a typographical error in our previous supplement to this Technical Specifications change request. The response to request for additional information, dated November 26,1996, references a I
previous submittal regarding IEB 80-04, dated August 27,1989, in the response to Question 2. The date .
of the previous submittal regarding IEB 80-04 should be July 27,1989, Please contact us if you have any questions.
Sincerely, Gary M. Krieser i Managef-Nuclear Industry I
& Regulatory Services CAC- ;
cc: . NRC Resident Inspector NRC Regional Administrator PSCW -
l Subscribed and sworn before me on !
this 12th day of December,1996. I i
- m. iu M
! Notary hublic, State of Wisconsin y
hiy/ommission expires ag/n/ hat.
i p y - -,a +- -w -,
,e
e l
l TECHNICAL SPECIFICATION CHANGE REOUEST 192 SUPPLEMENTAL INFORMATION i l
Introduction J
In a letter dated September 30,1996, Wisconsin Electric requested Technical Specifications change request 192. This Technical Specifications change request proposes to modify Technical Specifications section 15.3.3, " Emergency Core Cooling System, Auxiliary Cooling Systems, Air Recirculation Fan Coolers, and Containment Spray" to incorporate allowed outage times similar to those contained in NUREG-1431, Revision 1,
" Westinghouse Owner's Group Improved Standard Technical Specifications," and modify ;
the operability requirements for the service water system. The proposed changes to Technical Specifications section 15.3.7, " Auxiliary Electrical Systems," also reflect the l modified service water operability requirements. The proposed change to Technical l Specifications section 15.5.2, " Containment," modifies the heat removal capacity of the reactor containment air cooler units. A supplement to this Technical Specifications change request was provided in a letter dated November 13,1996.
1 This supplement proposes to modify the proposed Technical Specifications changes as follows:
- 1. Change TS 15.3.3.C to require four operable component cooling water pumps for two unit operation. The current requirement is three component cooling water pumps for two unit operation. Additionally, the allowed outage time for one component cooling I water pump is being changed from 24 to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The net effect of these two changes is a substantial improvement from the existing CCW Technical Specifications, because previously one of the four pumps could have been inoperable indefinitely 1 without limitation. 1
- 2. Modify the proposed TS 15.3.3.D.2.d to require five operable service water pumps for !
entry into this limiting condition for operation incead of the originally proposed requirement of four service water pumps. This change provides added assurance that sufficient service water flow will be available for all necessary equipment if the ;
containment fan cooler outlet motor operated valves are open in both units during an j accident.
- 3. The proposed removal of the containment cooling capability statement in the basis of Technical Specifications section 15.3.3 is not needed. The capability statement was l being removed from the Technical Specifications basis because it does not directly i support any of the operability requirements or LCOs for the containment cooling l systems. This statement is being maintained in the basis in recognition that this j capability always was and still is available. l l
Evaluation of these revised proposed Technical Specifications changes is provided in the following safety evaluation. The "No Significant Hazards Consideration" provided in the 1
l
I original Technical Specifications change request was reviewed. The results of this review
- are provided in this supplemental information. The revised edited Technical Specifications are also provided as an attachment.
]
Safety Evaluation l Proposed change 1. _
In the previous supplement to this Technical Specifications change request (letter dated i November 26,1996), it was noted that the component cooling water (CCW) Technical )
Specification could be substantially improved by changing the operability requirement for two unit operation from three pumps to four. Along with this operability requirement change, it is necessary to increase the allowed outage time for one of the required CCW pumps from 24 to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The net effect of these two changes is still a substantial improvement from the existing CCW Technical Specifications, because previously one of the four pumps could have been inoperable indefinitely without limitation. j The basis for Technical Specification section 15.3.3 states, "The component cooling water system is different from the other systems discussed above in that the components are so located in the Auxiliary Building as to be accessible for repair after a loss-of-coolant accident. The component cooling water pump together with one component cooling i
. water heat exchanger can accommodate the heat removal load on one unit either following a loss-of-coolant accident, or during normal plant shutdown. If during the post-accident :
phase the component cooling water supply is lost, core and containment cooling could be !
maintained until repairs are effected." In support of this Technical Specifications basis, j section 9.3 of the FSAR states, "If a break of a component cooling line occurs outside the containment, the leak could either be isolated and repaired, or the system could be :
shutdown for repairs depending on the position in the loop at which the break occurred. !
Access is available to required components. During this period, no heat removal from the l centainment by the residual heat removal system is required since the fan coolers' capability using service water exceeds decay heat generation." :
The current Technical Specifications for CCW, section 15.3.3.C, require two operable i pumps for single unit operation and three operable pumps for two unit operation. For two I unit operation, a single failure of one of the CCW pumps would leave two operable pumps q which is greater than the minimum requirement of one pump for accident mitigation. For single'or dual unit operation, the single failure of a train of emergency power after a loss
'of offsite power could leave one operable pump which is the minimum requirement for l accident mitigation.
FSAR Chapter 9 contains substantial information regarding the design and operation of the PBNP CCW system. The CCW system is considered part of the auxiliary cooling system (ACS) for the reactor. It is not automatically initiated for accident mitigation.
Operator action is required to initiate the ACS reactor cooling function. The general design criteria in the PBNP FSAR related to the CCW system (GDC 41 and 52) described 2
i
.y ,, ,. _ -
in section 9.1 state that the system shall provide sufficient performance capability to accommodate the failure of any single active component without resulting in undue risk to the health and safety.of the public.
FSAR Appendix B, " Functional Evaluation of the Components of the Systems Shared by the Two Units," states that two pumps are required for LOCA in one unit and hot shutdown of the other unit. This evaluation was based on four CCW pumps normally available. The repair capability for this system can be applied to the situation described above where two of the three available pumps could be assumed to fail. In this case the repair would be performed to restore a second pump.
The CCW pumps are nor:nally aligned with two pumps to each unit, one pump in each train per unit. If four CCW pumps are available at the outset of an event, a single failure of one train of emergency equipment would leave one operable CCW pump in each unit.
This configuration is consistent with the evaluation of the CCW system function contained in FSAR Appendix B described above. The capability of the CCW system starting with four pumps leaves two operational pumps after the failure of an entire train. This is considered preferable to the situation of starting with the three operable pumps because a repair is not necessary to restore a CCW pump and the possible requirement for cross-connection of the Unit 1 and Unit 2 CCW systems would not be needed. Therefore, the I proposed Technical Specifications require four operable CCW pumps for two unit operation. 2 The proposed change from a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowed outage time to a 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> allowed outage time is necessary to provide adequate time to repair a CCW pump. This allowed outage time is consistent with the allowed outage time for CCW contained in NUREG 1431, R Revision 1, " Westinghouse Owner's Group Improved Standard Technical Specifications." ,
As stated previously, the net effect of the increased operability requirement and longer allowed outage time is an improvement in the Technical Specifications. These changes provide added assurance that two pumps will be operable for accident mitigation in one unit and safe shutdown of the other.
Proposed Change 2.
The following description was provide in the original Technical Specifications change ;
request:
Insert new specification 15.3.3.D 2.d to allow the containment fan cooler outlet l motor operated valves to be open provided they are returned to the closed position ;
within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The containment fan cooler service water outlet motor operated !
valves consist of two fully redundant valves that are automatically opened in ;
response to a rafety injection signal. Either valve is capable of passing the full flow required for all four fan cooler units in accident mode. At various times, these valves are opened to allow testing of the containment fan coolers or adjustment of l the system flow rates. If one or both of these motor operated valves are open in a o
l l
3 I- _ . . _ . . _ . _ . _ . _
. . , 2
! t i unit, there may be insufficient service water flow if an accident occurs in the other l i-unit and a single failure occurs. Therefore, in this case, the other unit is in a !
limiting condition for operation because relaxation of single failure is necessary. l
- l. That unit would be considered the "affected unit" and hence the valves must be ;
closed within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or the affected unit must be shutdown. If the valves are i open in both units, they would both be considered "affected" until such time that l the motor operated valves were closed for a unit, at which time the affected unit !
j would be the unit with the closed valves. !
The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> allowed time is consistent with the relaxation of single failure and i allowed outage time associated with a loss of redundancy for the service water i system. For the case of single unit operation, the valves for the operating unit may be open without limitation if the valves for the shutdown unit are in the shut position or the flowpath is isolated.
The additional provision that requires at least four service water pumps to be operable incorporates the appropriate restriction to allow coincidental entry into j any of these service water system LCOs, as stated in the description of change to j TS 15.3.3.D.'2. 1 i
The two ways that this LCO can be exited have been added to this LCO for clarity. '!
The two ways this LCO can be exited include isolating the flowpath or returning ~ !
the valves to the closed position. f The modification to the proposed TS 15.3.3.D.2.d to require five operable service water pumps for entry into this limiting condition for operation,'instead of the originally proposed requirement of four se:vice water pumps, provides added assurance that ufficient service water flow will be available for all necessary equipment if the .
containment fan cooler outlet motor operated valves are open in both units during an accident and any or all of the other service water LCOs are in effect coincidentally.
Proposed Change 3.-
Technical Specifications change request 192 proposes the removal of the following capability statement from the basis of Technical Specifications section 15.3.3:
. In the event of a Design Basis Accident, any one of the following combinations will provide sufficient cooling to reduce containment pressure: (1) four fan coolers, (2) two containment spray pumps, (3) two fan coolers plus one containment spray pump.-
The proposed removal of the containment cooling capability statement in the basis of Technical Specifications section 15.3.3 is not needed. The capability statement was being removed from the Technical Specifications basis because it does not directly support any of the operability requirements or LCOn for the containment cooling systems. This t statement is being maintained in the basis in recognition that this capability always was and 1
4
-l
stillis available. In support of the reinstatement of this capability statement in the basis of section 15.3.3, analysis has been performed that shows the four fan cooler capability to maintain the post-accident containment pressure below the design value is still valid. The ;
results of this analysis (which are attached to the November 26,1996 submittal) show that !
the containment pressure and temperature response are not significantly affected by the
]
reduction in fan cooler heat removal rate. This analysis also includes the effect of steam generator replacement, for completeness.
Additionally, the emergency operating procedures are being reviewed and revised as necessary to allow operation of the containment spray system during the recirculation ;
phase of a LOCA. Containment spray continues to be considered to operate during the I injection phase of a LOCA. By proceduralization of containment spray operation during the recirculation phase of a LOCA, the capability statement is valid during both the injection and recirculation phases of a LOCA. The emergency operating precedures can continue to allow containment spray to be stopped at the end eithe injection phase of a LOCA based on the analyses that show containment pressure and temperature during this phase of the accident remain acceptable. Further evaluation of the environmental consequences of the loss of coolant accident (FSAR Section 14.3.5)is in progress. We expect to provide the results of this evaluation within a few weeks.
Review of"No Significant Hazards Consideration" The original"No Significant Hazards Consideration" provided with Technical Specifications change request 192 has been reviewed. The proposed modifications to this license amendment request do not alter any conclusions or the basis for these conclusions provided in the original"No Significant Hazards Consideration."
i The only part of the original evaluation that is affected by these proposed modifications is i the specific reference to the plant systems that are the subject of this license amendment request. The first section of the original"No Significant Hazards Consideration" states:
This license amendment request proposes to change the limiting conditions for operation, action statements, allowable outage times, and design specifications for the Point Beach Nuclear Plant Technical Specifications associated with the containment accident fan coolers, service water equipment, and normal and emergency power supplies.
The proposed modification to this license amendment request proposes the inclusion of a improvement to the limiting condition for operation associated with the component cooling water pump operability requirement for two unit operation. As stated previously, these changes provide added assurance that two pumps will be operable for accident mitigation in one unit and safe shutdown of the other. Therefore, the conclusions and the basis for the conclusions in the "No Significant Hazards Consideration" are not changed.
5