Response to Request for Additional Information Regarding Relief Request Number RR 5-8, Proposed Alternative to ASME Section XI Code Requirements for Repair of Reactor Pressure Vessel Head Penetrations
ML20272A163
Person / Time
Site: Palisades Entergy icon.png
Issue date: 09/28/2020
From: Gaston R
Entergy Nuclear Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML20272A162 List:
References
PNP 2020-034
Download: ML20272A163 (2)


Text

PROPRIETARY INFORMATION -WITHHOLD UNDER 10 CFR 2.390 UPON REMOVAL OF ATTACHMENT 1, THIS LETTER IS UNCONTROLLED Entergy Nuclear Operations, Inc.

1340 Echelon Parkway Jackson, MS 39213-8298 Tel 601-368-5138 Ron Gaston Director, Nuclear Licensing 10 CFR 50.55a PNP 2020-034 September 28, 2020 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Response to Request for Additional Information Regarding Relief Request Number RR 5-8, Proposed Alternative to ASME Section XI Code Requirements for Repair of Reactor Pressure Vessel Head Penetrations Palisades Nuclear Plant NRG Docket No. 50-255 Renewed Facility Operating License No. DPR-20

References:

1. Entergy Nuclear Operations, Inc. letter PNP 2020-031, Relief Request Number RR 5-8, Proposed Alternative to ASME Section XI Code requirements for Repair of Reactor Pressure Vessel Head Penetrations, (NRG ADAMS Accession Package Number ML20267A386), dated September 23, 2020
2. NRG email to Entergy Nuclear Operations, Inc., Request for Additional Information: Palisades Relief Request RR 5-8 (Proposed Alternative) for Reactor Pressure Vessel Head Penetration Repairs (EP/0:

L-2020-LLR-0128), Dated September 26, 2020 Pursuant to Title 1O of the Code of Federal Regulations (CFR) 50.55a(z)(1 ), Acceptable level of quality and safety, Entergy Nuclear Operations, Inc. (Entergy) submitted a request to the Nuclear Regulatory Commission for authorization of relief request number RR 5-8, Proposed Alternative to ASME Section XI Code Requirements for Repair of Reactor Pressure Vessel Head Penetrations, for the Palisades Nuclear Plant (Reference 1).

In Reference 2, Entergy received an electronic request for additional information (RAI) from the NRG. The Entergy response to the RAI is provided in Attachment 1.

PNP 2020-034 Page 2 of 2 is a Framatome report that provides the responses to the RAI and contains information considered proprietary to Framatome, Inc. On behalf of Framatome, Inc., Entergy requests that the NRC withhold this information in accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding. Attachment 2 contains an affidavit supporting withholding of the proprietary information. Attachment 3 contains a non-proprietary version of the RAI responses. Upon removal of the proprietary information in Attachment 1, the balance of this submittal is uncontrolled.

This letter contains no new commitments and no revised commitments.

Should you have any questions or require additional information, please contact Jim Miksa Regulatory Assurance Engineer at (269) 764-2945.

Should you have any questions associated with the affidavit, please contact Philip A. Opsal at Framatome, OF34, 3315 Old Forest Rd., Lynchburg, VA 24501.

Respectfully, RWG/jpm

Attachment:

1. Framatome Document No. ANP-3876 Revision 1Q1P, Response to NRG Request for Additional Information of Palisades Relief Request Number RR 5-8, Repair of Reactor Pressure Vessel Head Penetration, lnservice Inspection Program, Fifth Ten-Year Interval (Proprietary Information - Withhold Under 10 CFR 2.390)
2. Framatome, Inc. Affidavit Supporting Withholding of Proprietary Information
3. Framatome Document No. ANP-3876 Revision 1Q1NP, Response to NRG Request for Additional Information of Palisades Relief Request Number RR 5-8, Repair of Reactor Pressure Vessel Head Penetration, lnservice Inspection Program, Fifth Ten-Year Interval (Non-Proprietary) cc: NRC Region Ill Regional Administrator NRC Senior Resident Inspector -Palisades NRC Project Manager -Palisades