25A5675BB Revision 7 October 2019 ABWR Design Control Document Tier 2 Chapter 21 Volume 1 Copyright 1994, 2010, 2016, 2019 GE-Hitachi Nuclear Energy Americas LLC All Rights Reserved

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Chapter 21 Volume 1 List of Figures Figure 1.2-2 Reactor Building, Arrangement Elevation, Section A-A............................................21-1 Figure 1.2-2a Reactor Building, Arrangement Elevation, Section B-B ............................................21-2 Figure 1.2-3 Upper Drywell, Arrangement Elevation, Section A-A ...............................................21-3 Figure 1.2-3a Upper Drywell, Arrangement Elevation, Section B-B................................................21-3 Figure 1.2-3b Lower Drywell, Arrangement Elevation, Section A-A...............................................21-4 Figure 1.2-3c Wetwell, Arrangement Elevation, Sections A-A & B-B ............................................21-5 Figure 1.2-4 Reactor Building, Arrangement Plan at Elevation -8200 mm ....................................21-6 Figure 1.2-5 Reactor Building, Arrangement Plan at Elevation -1700 mm ....................................21-7 Figure 1.2-6 Reactor Building, Arrangement Plan at Elevation 4800/8500 mm.............................21-8 Figure 1.2-8 Reactor Building, Arrangement Plan at Elevation 12300 mm....................................21-9 Figure 1.2-9 Reactor Building, Arrangement Plan at Elevation 18100 mm..................................21-10 Figure 1.2-10 Reactor Building, Arrangement Plan at Elevation 23500 mm..................................21-11 Figure 1.2-11 Reactor Building, Arrangement Plan at Elevation 27200 mm..................................21-12 Figure 1.2-12 Reactor Building, Arrangement Plan at Elevation 31700/38200 mm.......................21-13 Figure 1.2-13a Drywell, Arrangement Plan at Elevation 12300 mm ................................................21-14 Figure 1.2-13b Drywell, Arrangement Plan at Elevation 15600 mm ................................................21-15 Figure 1.2-13c Drywell, Arrangement Plan at Elevation 18100 mm ................................................21-16 Figure 1.2-13d Drywell Steel Structure at Elevation 18100 mm.......................................................21-17 Figure 1.2-13e Lower Drywell, Arrangement Plan at Elevation -6600 to -1850 mm.......................21-18 Figure 1.2-13f Lower Drywell, Arrangement Plan at Elevation -1850 to 1750 mm ........................21-19 Figure 1.2-13g Lower Drywell, Arrangement Plan at Elevation 1750 to 4800 mm .........................21-20 Figure 1.2-13h Lower Drywell, Arrangement Plan at Elevation 4800 to 6700 mm .........................21-21 Figure 1.2-13i Wetwell, Arrangement Plan at Elevation -8200 mm ................................................21-22 Figure 1.2-13j Wetwell, Arrangement Plan at Elevation -1700 mm ................................................21-23 Figure 1.2-13k Wetwell, Arrangement Plan at Elevation 4800 mm..................................................21-24 Figure 1.2-14 Control and Service Building, Arrangement Elevation, Section A-A ......................21-25 Chapter 21 Figure TOC Volume 1-i

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 List of Figures (Continued)

Figure 1.2-15 Control and Service Building, Arrangement Elevation, Section B-B.......................21-26 Figure 1.2-16 Control Building, Arrangement Plan at Elevation -8200 mm...................................21-27 Figure 1.2-17 Control and Service Building, Arrangement Plan at Elevation -2150 mm...............21-28 Figure 1.2-18 Control and Service Building, Arrangement Plan at Elevation 3500 mm ................21-29 Figure 1.2-19 Control and Service Building, Arrangement Plan at Elevation 7900 mm ................21-30 Figure 1.2-20 Control and Service Building, Arrangement Plan at Elevation 12300 mm ..............21-31 Figure 1.2-21 Control and Service Building, Arrangement Plan at Elevation 17150 mm ..............21-32 Figure 1.2-22 Control and Service Building, Arrangement Plan at Elevation 22200 mm ..............21-33 Figure 1.2-23a Radwaste Building at Elevation -1500 mm ..............................................................21-34 Figure 1.2-23b Radwaste Building at Elevation 4800 mm................................................................21-35 Figure 1.2-23c Radwaste Building at Elevation 12300 mm..............................................................21-36 Figure 1.2-23d Radwaste Building at Elevation 21000 mm..............................................................21-37 Figure 1.2-23e Radwaste Building, Section A-A ..............................................................................21-38 Figure 1.2-24 Turbine Building, General Arrangement at Elevation 5300 mm .............................21-39 Figure 1.2-25 Turbine Building, General Arrangement at Elevation 12300 mm ............................21-40 Figure 1.2-26 Turbine Building, General Arrangement at Elevation 20300 mm ............................21-41 Figure 1.2-27 Turbine Building, General Arrangement at Elevation 30300 mm ............................21-42 Figure 1.2-28 Turbine Building, General Arrangement, Longitudinal Section A-A.......................21-43 Figure 1.2-29 Turbine Building, General Arrangement, Section B-B.............................................21-44 Figure 1.2-30 Turbine Building, General Arrangement, Section C-C.............................................21-45 Figure 1.2-31 Turbine Building, General Arrangement, Section D-D ............................................21-46 Figure 1.7-1 Piping and Instrumentation Diagram Symbols (Sheets 1-2) ....................................21-47 Figure 3H.1-23 Reactor Building Reactor Cavity Shield Blocks .......................................................21-49 Figure 3H.1-28 Configuration of RPV Pedestal.................................................................................21-50 Figure 3H.1-29 Rebar Arrangement of F/P Girder and Slab (1/2) .....................................................21-51 Figure 3H.1-30 Containment Structure Wall Reinforcement .............................................................21-52 Volume 1-ii Chapter 21 Figure TOC

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 List of Figures (Continued)

Figure 3H.1-31 Containment Structure Opening Reinforcement .......................................................21-53 Figure 3H.1-32 Containment Structure Opening Reinforcement .......................................................21-54 Figure 3H.1-33 Containment Structure Top Slab Reinforcement ......................................................21-55 Figure 3H.1-34 Reactor Building Foundation Reinforcement (Sheet 1)............................................21-56 Figure 3H.1-35 Reactor Building Foundation Reinforcement (Sheet 2)............................................21-57 Figure 3H.1-36 Diaphragm Floor Reinforcement ..............................................................................21-58 Figure 3H.1-37 List of Seismic Wall Sections ...................................................................................21-59 Figure 3H.2-21 Control Building Floor Plan at Elevation -8200 mm ................................................21-60 Figure 3H.2-22 Control Building Framing Plan at Elevation -2150 mm ...........................................21-61 Figure 3H.2-23 Control Building Framing Plan at Elevation 3500 mm ............................................21-62 Figure 3H.2-24 Control Building Framing Plan at Elevation 7900 mm ............................................21-63 Figure 3H.2-25 Control Building Framing Plan at Elevation 12300 and 13100 mm.........................21-64 Figure 3H.2-26 Control Building Framing Plan at Elevation 17150 and 18250 mm.........................21-65 Figure 3H.2-27 Control Building Framing Plan at Elevation 22200 and 22750 mm.........................21-66 Figure 3H.2-28 Control Building Section...........................................................................................21-67 Figure 3H.2-29 Control Building Section and Details .......................................................................21-68 Figure 3H.2-30 Control Building Details ...........................................................................................21-69 Figure 3H.3-11 Radwaste Building, Reinforced Concrete Basemat ..................................................21-70 Figure 3H.3-12 Radwaste Building, Structural Steel Framing Plan, Typical Floor...........................21-71 Figure 3H.3-13 Radwaste Building, Structural Steel Framing Plan, Elevation 28000 mm ...............21-72 Figure 3H.3-14 Radwaste Building, Section A-A ..............................................................................21-73 Figure 3H.3-15 Radwaste Building, Exterior Walls Sections ............................................................21-74 Figure 3H.3-16 Radwaste Building, Sections and Details..................................................................21-75 Figure 4.6-8 Control Rod Drive System P&ID (Sheets 1-3) ........................................................21-76 Figure 4.6-9 Control Rod Drive System PFD................................................................................21-79 Figure 5.1-3 Nuclear Boiler System P&ID (Sheets 1-11).............................................................21-80 Chapter 21 Figure TOC Volume 1-iii

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 List of Figures (Continued)

Figure 5.2-8 Leak Detection and Isolation System IED (Sheets 1-10) .........................................21-91 Figure 5.4-4 Reactor Recirculation System P&ID (Sheets 1-2) .................................................21-101 Figure 5.4-5 Reactor Recirculation System PFD.........................................................................21-103 Figure 5.4-8 Reactor Core Isolation Cooling System P&ID (Sheets 1-3) ..................................21-104 Volume 1-iv Chapter 21 Figure TOC

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-2 Reactor Building, Arrangement Elevation, Section A-A 21-1

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-2a Reactor Building, Arrangement Elevation, Section B-B 21-2

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-3 Upper Drywell, Arrangement Elevation, Section A-A Figure 1.2-3a Upper Drywell, Arrangement Elevation, Section B-B 21-3

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-3b Lower Drywell, Arrangement Elevation, Section A-A 21-4

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-3c Wetwell, Arrangement Elevation, Sections A-A & B-B 21-5

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-4 Reactor Building, Arrangement Plan at Elevation -8200 mm 21-6

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-5 Reactor Building, Arrangement Plan at Elevation -1700 mm 21-7

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-6 Reactor Building, Arrangement Plan at Elevation 4800/8500 mm 21-8

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-8 Reactor Building, Arrangement Plan at Elevation 12300 mm 21-9

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-9 Reactor Building, Arrangement Plan at Elevation 18100 mm 21-10

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-10 Reactor Building, Arrangement Plan at Elevation 23500 mm 21-11

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-11 Reactor Building, Arrangement Plan at Elevation 27200 mm 21-12

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-12 Reactor Building, Arrangement Plan at Elevation 31700/38200 mm 21-13

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-13a Drywell, Arrangement Plan at Elevation 12300 mm 21-14

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-13b Drywell, Arrangement Plan at Elevation 15600 mm 21-15

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-13c Drywell, Arrangement Plan at Elevation 18100 mm 21-16

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-13d Drywell Steel Structure at Elevation 18100 mm 21-17

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-13e Lower Drywell, Arrangement Plan at Elevation -6600 to -1850 mm 21-18

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-13f Lower Drywell, Arrangement Plan at Elevation -1850 to 1750 mm 21-19

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-13g Lower Drywell, Arrangement Plan at Elevation 1750 to 4800 mm 21-20

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-13h Lower Drywell, Arrangement Plan at Elevation 4800 to 6700 mm 21-21

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-13i Wetwell, Arrangement Plan at Elevation -8200 mm 21-22

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-13j Wetwell, Arrangement Plan at Elevation -1700 mm 21-23

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-13k Wetwell, Arrangement Plan at Elevation 4800 mm 21-24

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-14 Control and Service Building, Arrangement Elevation, Section A-A 21-25

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-15 Control and Service Building, Arrangement Elevation, Section B-B 21-26

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-16 Control Building, Arrangement Plan at Elevation -8200 mm 21-27

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-17 Control and Service Building, Arrangement Plan at Elevation -2150 mm 21-28

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-18 Control and Service Building, Arrangement Plan at Elevation 3500 mm 21-29

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-19 Control and Service Building, Arrangement Plan at Elevation 7900 mm 21-30

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-20 Control and Service Building, Arrangement Plan at Elevation 12300 mm 21-31

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-21 Control and Service Building, Arrangement Plan at Elevation 17150 mm 21-32

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-22 Control and Service Building, Arrangement Plan at Elevation 22200 mm 21-33

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-23a Radwaste Building at Elevation -1500 mm 21-34

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-23b Radwaste Building at Elevation 4800 mm 21-35

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-23c Radwaste Building at Elevation 12300 mm 21-36

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-23d Radwaste Building at Elevation 21000 mm 21-37

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-23e Radwaste Building, Section A-A 21-38

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-24 Turbine Building, General Arrangement at Elevation 5300 mm 21-39

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-25 Turbine Building, General Arrangement at Elevation 12300 mm 21-40

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-26 Turbine Building, General Arrangement at Elevation 20300 mm 21-41

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-27 Turbine Building, General Arrangement at Elevation 30300 mm 21-42

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-28 Turbine Building, General Arrangement, Longitudinal Section A-A 21-43

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-29 Turbine Building, General Arrangement, Section B-B 21-44

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-30 Turbine Building, General Arrangement, Section C-C 21-45

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 1.2-31 Turbine Building, General Arrangement, Section D-D 21-46

ABWR 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 1.7-1 Piping and Instrumentation Diagram Symbols (Sheet 1 of 2) 21-47

ABWR 21-48 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 1.7-1 Piping and Instrumentation Diagram Symbols (Sheet 2 of 2)

ABWR 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 3H.1-23 Reactor Building Reactor Cavity Shield Blocks 21-49

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.1-28 Configuration of RPV Pedestal 21-50

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.1-29 Rebar Arrangement of F/P Girder and Slab (1/2) 21-51

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.1-30 Containment Structure Wall Reinforcement 21-52

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.1-31 Containment Structure Opening Reinforcement 21-53

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.1-32 Containment Structure Opening Reinforcement 21-54

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.1-33 Containment Structure Top Slab Reinforcement 21-55

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.1-34 Reactor Building Foundation Reinforcement (Sheet 1) 21-56

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.1-35 Reactor Building Foundation Reinforcement (Sheet 2) 21-57

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.1-36 Diaphragm Floor Reinforcement 21-58

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.1-37 List of Seismic Wall Sections 21-59

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.2-21 Control Building Floor Plan at Elevation -8200 mm 21-60

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.2-22 Control Building Framing Plan at Elevation -2150 mm 21-61

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.2-23 Control Building Framing Plan at Elevation 3500 mm 21-62

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.2-24 Control Building Framing Plan at Elevation 7900 mm 21-63

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.2-25 Control Building Framing Plan at Elevation 12300 and 13100 mm 21-64

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.2-26 Control Building Framing Plan at Elevation 17150 and 18250 mm 21-65

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.2-27 Control Building Framing Plan at Elevation 22200 and 22750 mm 21-66

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.2-28 Control Building Section 21-67

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.2-29 Control Building Section and Details 21-68

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.2-30 Control Building Details 21-69

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.3-11 Radwaste Building, Reinforced Concrete Basemat 21-70

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.3-12 Radwaste Building, Structural Steel Framing Plan, Typical Floor 21-71

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.3-13 Radwaste Building, Structural Steel Framing Plan, Elevation 28000 mm 21-72

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.3-14 Radwaste Building, Section A-A 21-73

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.3-15 Radwaste Building, Exterior Walls Sections 21-74

25A5675BB Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 3H.3-16 Radwaste Building, Sections and Details 21-75

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 4.6-8 Control Rod Drive System P&ID (Sheet 1 of 3) 21-76

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 4.6-8 Control Rod Drive System P&ID (Sheet 2 of 3) 21-77

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 4.6-8 Control Rod Drive System P&ID (Sheet 3 of 3) 21-78

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 4.6-9 Control Rod Drive System PFD 21-79

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 5.1-3 Nuclear Boiler System P&ID (Sheet 1 of 11) 21-80

ABWR 566 25A5675BB Revision 7



&+59$/9(6 566



9$/9(/

Design Control Document/Tier 2 Figure 5.1-3 Nuclear Boiler System P&ID (Sheet 2 of 11) 21-81

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 5.1-3 Nuclear Boiler System P&ID (Sheet 3 of 11) 21-82

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 5.1-3 Nuclear Boiler System P&ID (Sheet 4 of 11) 21-83

ABWR 21-84



566 25A5675BB Revision 7



566

/7



Design Control Document/Tier 2 Figure 5.1-3 Nuclear Boiler System P&ID (Sheet 5 of 11)

ABWR 25A5675BB Revision 7 RSS 13 LT 13 004 RSS B

Design Control Document/Tier 2 Figure 5.1-3 Nuclear Boiler System P&ID (Sheet 6 of 11) 21-85

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 5.1-3 Nuclear Boiler System P&ID (Sheet 7 of 11) 21-86

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 5.1-3 Nuclear Boiler System P&ID (Sheet 8 of 11) 21-87

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 5.1-3 Nuclear Boiler System P&ID (Sheet 9 of 11) 21-88

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 5.1-3 Nuclear Boiler System P&ID (Sheet 10 of 11) 21-89

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 5.1-3 Nuclear Boiler System P&ID (Sheet 11 of 11) 21-90

ABWR 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.2-8 Leak Detection and Isolation System IED (Sheet 1 of 10) 21-91

ABWR 21-92 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.2-8 Leak Detection and Isolation System IED (Sheet 2 of 10)

ABWR 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.2-8 Leak Detection and Isolation System IED (Sheet 3 of 10) 21-93

ABWR 21-94 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.2-8 Leak Detection and Isolation System IED (Sheet 4 of 10)

ABWR 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.2-8 Leak Detection and Isolation System IED (Sheet 5 of 10) 21-95

ABWR 21-96 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.2-8 Leak Detection and Isolation System IED (Sheet 6 of 10)

ABWR 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.2-8 Leak Detection and Isolation System IED (Sheet 7 of 10) 21-97

ABWR 21-98 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.2-8 Leak Detection and Isolation System IED (Sheet 8 of 10)

ABWR 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.2-8 Leak Detection and Isolation System IED (Sheet 9 of 10) 21-99

ABWR 21-100 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.2-8 Leak Detection and Isolation System IED (Sheet 10 of 10)

ABWR 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.4-4 Reactor Recirculation System P&ID (Sheet 1 of 2)21-101

ABWR 21-102 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.4-4 Reactor Recirculation System P&ID (Sheet 2 of 2)

25A5675BB Revision 7 ABWR Design Control Document/Tier 2 Figure 5.4-5 Reactor Recirculation System PFD 21-103

ABWR 21-104 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.4-8 Reactor Core Isolation Cooling System P&ID (Sheet 1 of 3)

ABWR 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.4-8 Reactor Core Isolation Cooling System P&ID (Sheet 2 of 3)21-105

ABWR 21-106 25A5675BB Revision 7 Design Control Document/Tier 2 Figure 5.4-8 Reactor Core Isolation Cooling System P&ID (Sheet 3 of 3)