25A5675BJ Revision 7 October 2019 ABWR Design Control Document Tier 2 Chapter 21 Volume 8 Copyright 1994, 2010, 2016, 2019 GE-Hitachi Nuclear Energy Americas LLC All Rights Reserved

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 Chapter 21 Volume 8 List of Figures Figure 9A.4-16 Control Building Fire Protection at Elevation 12300 mm ......................................21-776 Figure 9A.4-16a Control Building Fire Protection at Elevation 17150 mm ......................................21-777 Figure 9A.4-16b Control Building Fire Protection at Elevation 22200 mm ......................................21-778 Figure 9A.4-17 Turbine Building Fire Protection, Section A-A ......................................................21-779 Figure 9A.4-18 Turbine Building Fire Protection at Elevation 5300 mm........................................21-780 Figure 9A.4-19 Turbine Building Fire Protection at Elevation 12300 mm......................................21-781 Figure 9A.4-20 Turbine Building Fire Protection at Elevation 20300 mm......................................21-782 Figure 9A.4-21 Turbine Building Fire Protection at Elevation 30300 mm......................................21-783 Figure 9A.4-22 Service Building Fire Protection, Section B-B (See Figure 9A.4-11) ....................21-771 Figure 9A.4-23 Service Building Fire Protection at Elevation -2150 mm (See Figure 9A.4-13) ....21-773 Figure 9A.4-24 Service Building Fire Protection at Elevation 3500 mm (See Figure 9A.4-14) .....21-774 Figure 9A.4-25 Service Building Fire Protection at Elevation 7900 mm (See Figure 9A.4-15) .....21-775 Figure 9A.4-26 Service Building Fire Protection at Elevation 12300 mm (See Figure 9A.4-16) ...21-776 Figure 9A.4-27 Service Building Fire Protection at Elevation 17150 mm (See Figure 9A.4-16a) .............................................................................................21-777 Figure 9A.4-28 Radwaste Building Fire Protection, Section A-A ...................................................21-784 Figure 9A.4-29 Radwaste Building Fire Protection at Elevation -1500 mm....................................21-785 Figure 9A.4-30 Radwaste Building Fire Protection at Elevation 4800 mm .....................................21-786 Figure 9A.4-31 Radwaste Building Fire Protection at Elevation 12300 mm ...................................21-787 Figure 9A.4-32 Radwaste Building Fire Protection at Elevation 21000 mm ...................................21-788 Figure 10.1-2 Reference Heat Balance for Guaranteed Reactor Rating ........................................21-789 Figure 10.1-3 Reference Heat Balance for Valves-Wide-Open (VWO) .......................................21-790 Figure 11.2-1 Radwaste System PFD ............................................................................................21-791 Figure 11.3-1 Offgas System PFD (Sheets 1-2)............................................................................21-792 Figure 11.3-2 Offgas System P&ID (Sheets 1-3) .........................................................................21-794 Figure 12.3-1 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation -8200 mm (B3F) ................................................................21-797 Chapter 21 Figure TOC Volume 8-i

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 List of Figures (Continued)

Figure 12.3-2 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation -1700 mm (B2F) ................................................................21-798 Figure 12.3-3 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 4800/8500 mm (B1F).........................................................21-799 Figure 12.3-5 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 12300 mm (1F) ..................................................................21-800 Figure 12.3-6 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 18100 mm (2F) ..................................................................21-801 Figure 12.3-7 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 23500 mm (3F) ..................................................................21-802 Figure 12.3-8 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 27200 mm (3.5F) ...............................................................21-803 Figure 12.3-9 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 31700/38200 mm (4FM)....................................................21-804 Figure 12.3-10 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation, Section A-A...........................................................................................21-805 Figure 12.3-11 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation, Section B-B ...........................................................................................21-806 Figure 12.3-12 Reactor Building Radiation Zone Map Post LOCA at Elevation -8200 mm (B3F) .................................................................................21-807 Figure 12.3-13 Reactor Building Radiation Zone Map Post LOCA at Elevation -1700 mm (B2F) .................................................................................21-808 Figure 12.3-14 Reactor Building Radiation Zone Map Post LOCA at Elevation 4800/8500 mm (B1F)..........................................................................21-809 Figure 12.3-16 Reactor Building Radiation Zone Map Post LOCA at Elevation 12300 mm (1F) ...................................................................................21-810 Figure 12.3-17 Reactor Building Radiation Zone Map Post LOCA at Elevation 18100 mm (2F) ...................................................................................21-811 Figure 12.3-18 Reactor Building Radiation Zone Map Post LOCA at Elevation 23500 mm (3F) ...................................................................................21-812 Figure 12.3-19 Reactor Building Radiation Zone Map Post LOCA at Elevation 27200 mm (3.5F) ................................................................................21-813 Figure 12.3-20 Reactor Building Radiation Zone Map Post LOCA at Elevation 31700/38200 mm (4FM).....................................................................21-814 Volume 8-ii Chapter 21 Figure TOC

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 List of Figures (Continued)

Figure 12.3-21 Reactor Building Radiation Zone Map Post LOCA, Section A-A .........................21-815 Figure 12.3-22 Reactor Building Radiation Zone Map Post LOCA, Section B-B..........................21-816 Figure 12.3-37 Radwaste Building, Radiation Zone Map, Normal Operation at Elevation -1500 mm ............................................................................................21-817 Figure 12.3-38 Radwaste Building, Radiation Zone Map, Normal Operation at Elevation -4800 mm ............................................................................................21-818 Figure 12.3-39 Radwaste Building, Radiation Zone Map, Normal Operation at Elevation 12300 mm ...........................................................................................21-819 Figure 12.3-40 Radwaste Building, Radiation Zone Map, Normal Operation at Elevation 21000 mm ...........................................................................................21-820 Figure 12.3-41 Radwaste Building, Radiation Zone Map, Normal Operation, Section A-A..........21-821 Figure 12.3-42 Control Building, Radiation Zone, Normal Operation at Elevation -8200 mm......21-822 Figure 12.3-43 Control and Service Building, Radiation Zone, Normal Operation at Elevation -2150 mm ............................................................................................21-823 Figure 12.3-44 Control and Service Building, Radiation Zone, Normal Operation at Elevation 3500 mm .............................................................................................21-824 Figure 12.3-45 Control and Service Building, Radiation Zone, Normal Operation at Elevation 7900 mm .............................................................................................21-825 Figure 12.3-46 Control and Service Building, Radiation Zone, Normal Operation at Elevation 12300 mm ...........................................................................................21-826 Figure 12.3-47 Control and Service Building, Radiation Zone, Normal Operation at Elevation 17150 mm ...........................................................................................21-827 Figure 12.3-48 Control and Service Building, Radiation Zone, Normal Operation, Side View, Cross Section B-B ................................................................................21-828 Figure 12.3-49 Turbine Building, Radiation Zone at Elevation 5300 mm ......................................21-829 Figure 12.3-50 Turbine Building, Radiation Zone at Elevation 12300 mm ....................................21-830 Figure 12.3-51 Turbine Building, Radiation Zone at Elevation 20300 mm ....................................21-831 Figure 12.3-52 Turbine Building, Radiation Zone at Elevation 30300 mm ....................................21-832 Figure 12.3-53 Turbine Building, Radiation Zone at Normal Operation Longitudinal Section A-A.............................................................................................................21-833 Figure 12.3-54 Control and Service Building, Radiation Zone, Post LOCA, Section B-B.............21-834 Chapter 21 Figure TOC Volume 8-iii

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 List of Figures (Continued)

Figure 12.3-55 Turbine Building, Radiation Zone, Post LOCA, Longitudinal Section A-A..........21-835 Figure 12.3-56 Reactor Building, Area Radiation Monitors at Elevation -8200 mm......................21-836 Figure 12.3-57 Reactor Building, Area Radiation Monitors at Elevation -1700 mm......................21-837 Figure 12.3-58 Reactor Building, Area Radiation Monitors at Elevation 4800/8500 mm..............21-838 Figure 12.3-59 Reactor Building, Area Radiation Monitors at Elevation 12300 mm .....................21-839 Figure 12.3-60 Reactor Building, Area Radiation Monitors at Elevation 23500 mm .....................21-840 Figure 12.3-61 Reactor Building, Area Radiation Monitors at Elevation 27200 mm .....................21-841 Figure 12.3-62 Reactor Building, Area Radiation Monitors at Elevation 31700/38200 mm..........21-842 Figure 12.3-63 Reactor Building, Area Radiation Monitors, Section B-B......................................21-843 Figure 12.3-64 Control and Service Buildings, Area Radiation Monitors, Section B-B.................21-844 Figure 12.3-65 Radwaste Building, Area Radiation Monitors at Elevation -1500 mm ..................21-845 Figure 12.3-66 Radwaste Building, Area Radiation Monitors at Elevation 4800 mm....................21-846 Figure 12.3-67 Radwaste Building, Area Radiation Monitors at Elevation 12300 mm..................21-847 Figure 12.3-68 Radwaste Building, Area Radiation Monitors at Elevation 21000 mm..................21-848 Figure 12.3-70 Turbine Building, Area Radiation Monitors at Elevation 12300 mm.....................21-849 Figure 12.3-71 Turbine Building, Area Radiation Monitors at Elevation 20300 mm.....................21-850 Figure 12.3-72 Turbine Building, Area Radiation Monitors at Elevation 30300 mm.....................21-851 Figure 12.3-73 Turbine Building, Area Radiation Monitors, Longitudinal Section A-A ...............21-852 Figure 15B-3 Fine Motion Control Rod Drive ..............................................................................21-853 Figure 18C-5 Arrangement of Equipment of Main Control Console............................................21-854 Figure 18C-7 Fixed-Position Display............................................................................................21-855 Figure 20.3.4-5a Low Pressure Core Flooder Sparger (Sheet 1)........................................................21-856 Figure 20.3.4-5b Low Pressure Core Flooder Sparger (Sheet 2)........................................................21-857 Figure 20.3.4-5c High Pressure Core Flooder Sparger.......................................................................21-858 Volume 8-iv Chapter 21 Figure TOC

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-16 Control Building Fire Protection at Elevation 12300 mm 21-776

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-16a Control Building Fire Protection at Elevation 17150 mm 21-777

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-16b Control Building Fire Protection at Elevation 22200 mm 21-778

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-17 Turbine Building Fire Protection, Section A-A 21-779

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-18 Turbine Building Fire Protection at Elevation 5300 mm 21-780

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-19 Turbine Building Fire Protection at Elevation 12300 mm 21-781

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-20 Turbine Building Fire Protection at Elevation 20300 mm 21-782

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-21 Turbine Building Fire Protection at Elevation 30300 mm 21-783

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-28 Radwaste Building Fire Protection, Section A-A 21-784

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-29 Radwaste Building Fire Protection at Elevation -1500 mm 21-785

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-30 Radwaste Building Fire Protection at Elevation 4800 mm 21-786

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-31 Radwaste Building Fire Protection at Elevation 12300 mm 21-787

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 9A.4-32 Radwaste Building Fire Protection at Elevation 21000 mm 21-788

ABWR 25A5675BJ Revision 7 Design Control Document/Tier 2 Figure 10.1-2 Reference Heat Balance for Guaranteed Reactor Rating 21-789

ABWR 21-790 25A5675BJ Revision 7 Design Control Document/Tier 2 Figure 10.1-3 Reference Heat Balance for Valves-Wide-Open (VWO)

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 Figure 11.2-1 Radwaste System PFD 21-791

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 Figure 11.3-1 Offgas System PFD (Sheet 1 of 2)21-792

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 Figure 11.3-1 Offgas System PFD (Sheet 2 of 2)21-793

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 Figure 11.3-2 Offgas System P&ID (Sheet 1 of 3)21-794

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 Figure 11.3-2 Offgas System P&ID (Sheet 2 of 3)21-795

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 Figure 11.3-2 Offgas System P&ID (Sheet 3 of 3)21-796

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-1 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation -8200 mm (B3F)21-797

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-2 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation -1700 mm (B2F)21-798

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-3 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 4800/8500 mm (B1F)21-799

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-5 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 12300 mm (1F)21-800

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-6 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 18100 mm (2F)21-801

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-7 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 23500 mm (3F)21-802

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-8 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 27200 mm (3.5F)21-803

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-9 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation at Elevation 31700/38200 mm (4FM)21-804

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-10 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation, Section A-A 21-805

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-11 Reactor Building Radiation Zone Map for Full Power and Shutdown Operation, Section B-B 21-806

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-12 Reactor Building Radiation Zone Map Post LOCA at Elevation -8200 mm (B3F)21-807

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-13 Reactor Building Radiation Zone Map Post LOCA at Elevation -1700 mm (B2F)21-808

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-14 Reactor Building Radiation Zone Map Post LOCA at Elevation 4800/8500 mm (B1F)21-809

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-16 Reactor Building Radiation Zone Map Post LOCA at Elevation 12300 mm (1F)21-810

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-17 Reactor Building Radiation Zone Map Post LOCA at Elevation 18100 mm (2F)21-811

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-18 Reactor Building Radiation Zone Map Post LOCA at Elevation 23500 mm (3F)21-812

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-19 Reactor Building Radiation Zone Map Post LOCA at Elevation 27200 mm (3.5F)21-813

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-20 Reactor Building Radiation Zone Map Post LOCA at Elevation 31700/38200 mm (4FM)21-814

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-21 Reactor Building Radiation Zone Map Post LOCA, Section A-A 21-815

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-22 Reactor Building Radiation Zone Map Post LOCA, Section B-B 21-816

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-37 Radwaste Building, Radiation Zone Map, Normal Operation at Elevation -1500 mm 21-817

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-38 Radwaste Building, Radiation Zone Map, Normal Operation at Elevation -4800 mm 21-818

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-39 Radwaste Building, Radiation Zone Map, Normal Operation at Elevation 12300 mm 21-819

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-40 Radwaste Building, Radiation Zone Map, Normal Operation at Elevation 21000 mm 21-820

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-41 Radwaste Building, Radiation Zone Map, Normal Operation, Section A-A 21-821

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-42 Control Building, Radiation Zone, Normal Operation at Elevation -8200 mm 21-822

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-43 Control and Service Building, Radiation Zone, Normal Operation at Elevation -2150 mm 21-823

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-44 Control and Service Building, Radiation Zone, Normal Operation at Elevation 3500 mm 21-824

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-45 Control and Service Building, Radiation Zone, Normal Operation at Elevation 7900 mm 21-825

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-46 Control and Service Building, Radiation Zone, Normal Operation at Elevation 12300 mm 21-826

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-47 Control and Service Building, Radiation Zone, Normal Operation at Elevation 17150 mm 21-827

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-48 Control and Service Building, Radiation Zone, Normal Operation, Side View, Cross Section B-B 21-828

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-49 Turbine Building, Radiation Zone at Elevation 5300 mm 21-829

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-50 Turbine Building, Radiation Zone at Elevation 12300 mm 21-830

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-51 Turbine Building, Radiation Zone at Elevation 20300 mm 21-831

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-52 Turbine Building, Radiation Zone at Elevation 30300 mm 21-832

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-53 Turbine Building, Radiation Zone at Normal Operation Longitudinal Section A-A 21-833

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-54 Control and Service Building, Radiation Zone, Post LOCA, Section B-B 21-834

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-55 Turbine Building, Radiation Zone, Post LOCA, Longitudinal Section A-A 21-835

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-56 Reactor Building, Area Radiation Monitors at Elevation -8200 mm 21-836

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-57 Reactor Building, Area Radiation Monitors at Elevation -1700 mm 21-837

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-58 Reactor Building, Area Radiation Monitors at Elevation 4800/8500 mm 21-838

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-59 Reactor Building, Area Radiation Monitors at Elevation 12300 mm 21-839

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-60 Reactor Building, Area Radiation Monitors at Elevation 23500 mm 21-840

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-61 Reactor Building, Area Radiation Monitors at Elevation 27200 mm 21-841

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-62 Reactor Building, Area Radiation Monitors at Elevation 31700/38200 mm 21-842

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-63 Reactor Building, Area Radiation Monitors, Section B-B 21-843

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-64 Control and Service Buildings, Area Radiation Monitors, Section B-B 21-844

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-65 Radwaste Building, Area Radiation Monitors at Elevation -1500 mm 21-845

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-66 Radwaste Building, Area Radiation Monitors at Elevation 4800 mm 21-846

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-67 Radwaste Building, Area Radiation Monitors at Elevation 12300 mm 21-847

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-68 Radwaste Building, Area Radiation Monitors at Elevation 21000 mm 21-848

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-70 Turbine Building, Area Radiation Monitors at Elevation 12300 mm 21-849

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-71 Turbine Building, Area Radiation Monitors at Elevation 20300 mm 21-850

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-72 Turbine Building, Area Radiation Monitors at Elevation 30300 mm 21-851

25A5675BJ Revision 7 Security-Sensitive Information ABWR Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 Figure 12.3-73 Turbine Building, Area Radiation Monitors, Longitudinal Section A-A 21-852

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 Figure 15B-3 Fine Motion Control Rod Drive 21-853

ABWR 21-854 25A5675BJ Revision 7 Design Control Document/Tier 2 Figure 18C-5 Arrangement of Equipment of Main Control Console

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 Figure 18C-7 Fixed-Position Display 21-855

ABWR 21-856 25A5675BJ Revision 7 Design Control Document/Tier 2 Figure 20.3.4-5a Low Pressure Core Flooder Sparger (Sheet 1)

ABWR 25A5675BJ Revision 7 Design Control Document/Tier 2 Figure 20.3.4-5b Low Pressure Core Flooder Sparger (Sheet 2)21-857

25A5675BJ Revision 7 ABWR Design Control Document/Tier 2 Figure 20.3.4-5c High Pressure Core Flooder Sparger 21-858