GE-Hitachi ABWR Design Control Document Tier 1 & 2, Rev. 7 - Chapter 21 - Engineering Drawings - Volume 2
ML20007E362
Person / Time
Site: 05200001, 05200045
Issue date: 12/20/2019
From: Michelle Catts
GE-Hitachi Nuclear Energy Americas
To:
Office of Nuclear Reactor Regulation
Shea J
References
GEHITACHIABWR, GEHITACHIABWR.SUBMISSION.8, 25A5675.P, 25A5675.P.7
Download: ML20007E362 (128)


Text

25A5675BC Revision 7 October 2019 ABWR Design Control Document Tier 2 Chapter 21 Volume 2 Copyright 1994, 2010, 2016, 2019 GE-Hitachi Nuclear Energy Americas LLC All Rights Reserved

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Chapter 21 Volume 2 List of Figures Figure 5.4-9 Reactor Core Isolation Cooling System PFD (Sheets 1-2) ....................................21-107 Figure 5.4-10 Residual Heat Removal System P&ID (Sheets 1-7) ..............................................21-109 Figure 5.4-11 Residual Heat Removal System PFD (Sheets 1-2).................................................21-116 Figure 5.4-12 Reactor Water Cleanup System P&ID (Sheets 1-4)...............................................21-118 Figure 5.4-13 Reactor Water Cleanup System PFD (Sheets 1-2) .................................................21-122 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheets 1-11) ...............................................21-124 Figure 6.2-38 Group Classification and Containment Isolation Diagram (Sheets 1-2) ................21-135 Figure 6.2-39 Atmospheric Control System P&ID (Sheets 1-3) ..................................................21-137 Figure 6.2-40 Flammability Control System P&ID (Sheets 1-2)..................................................21-140 Figure 6.3-1 High Pressure Core Flooder System PFD (Sheets 1-2)..........................................21-142 Figure 6.3-7 High Pressure Core Flooder System P&ID (Sheets 1-2)........................................21-144 Figure 6.5-1 Standby Gas Treatment System P&ID (Sheets 1-3)...............................................21-146 Figure 6.7-1 High Pressure Nitrogen Gas Supply System P&ID ................................................21-149 Figure 7.2-9 Reactor Protection System IED (Sheets 1-11) .......................................................21-150 Figure 7.2-10 Reactor Protection System IBD (Sheets 1-72) .......................................................21-161 Chapter 21 Figure TOC Volume 2-i

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-9 Reactor Core Isolation Cooling System PFD (Sheet 1 of 2)21-107

ABWR 21-108 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-9 Reactor Core Isolation Cooling System PFD (Sheet 2 of 2)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-10 Residual Heat Removal System P&ID (Sheet 1 of 7)21-109

ABWR 21-110 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-10 Residual Heat Removal System P&ID (Sheet 2 of 7)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-10 Residual Heat Removal System P&ID (Sheet 3 of 7)21-111

ABWR 21-112 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-10 Residual Heat Removal System P&ID (Sheet 4 of 7)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-10 Residual Heat Removal System P&ID (Sheet 5 of 7)21-113

ABWR 21-114 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-10 Residual Heat Removal System P&ID (Sheet 6 of 7)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-10 Residual Heat Removal System P&ID (Sheet 7 of 7)21-115

ABWR 21-116 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-11 Residual Heat Removal System PFD (Sheet 1 of 2)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-11 Residual Heat Removal System PFD (Sheet 2 of 2)21-117

ABWR 21-118 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-12 Reactor Water Cleanup System P&ID (Sheet 1 of 4)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-12 Reactor Water Cleanup System P&ID (Sheet 2 of 4)21-119

ABWR 21-120 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-12 Reactor Water Cleanup System P&ID (Sheet 3 of 4)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-12 Reactor Water Cleanup System P&ID (Sheet 4 of 4)21-121

ABWR 21-122 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-13 Reactor Water Cleanup System PFD (Sheet 1 of 2)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-13 Reactor Water Cleanup System PFD (Sheet 2 of 2)21-123

ABWR 21-124 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheet 1 of 11)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheet 2 of 11)21-125

ABWR 21-126 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheet 3 of 11)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheet 4 of 11)21-127

ABWR 21-128 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheet 5 of 11)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheet 6 of 11)21-129

ABWR 21-130 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheet 7 of 11)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheet 8 of 11)21-131

ABWR 21-132 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheet 9 of 11)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheet 10 of 11)21-133

ABWR 21-134 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 5.4-14 Reactor Water Cleanup System IBD (Sheet 11 of 11)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.2-38 Group Classification and Containment Isolation Diagram (Sheet 1 of 2)21-135

ABWR 21-136 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.2-38 Group Classification and Containment Isolation Diagram (Sheet 2 of 2)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.2-39 Atmospheric Control System P&ID (Sheet 1 of 3)21-137

ABWR 21-138 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.2-39 Atmospheric Control System P&ID (Sheet 2 of 3)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.2-39 Atmospheric Control System P&ID (Sheet 3 of 3)21-139

ABWR 21-140 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.2-40 Flammability Control System P&ID (Sheet 1 of 2)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.2-40 Flammability Control System P&ID (Sheet 2 of 2)21-141

ABWR 21-142 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.3-1 High Pressure Core Flooder System PFD (Sheet 1 of 2)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.3-1 High Pressure Core Flooder System PFD (Sheet 2 of 2)21-143

ABWR 21-144 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.3-7 High Pressure Core Flooder System P&ID (Sheet 1 of 2)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.3-7 High Pressure Core Flooder System P&ID (Sheet 2 of 2)21-145

ABWR 21-146 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.5-1 Standby Gas Treatment System P&ID (Sheet 1 of 3)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.5-1 Standby Gas Treatment System P&ID (Sheet 2 of 3)21-147

ABWR 21-148 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 6.5-1 Standby Gas Treatment System P&ID (Sheet 3 of 3)

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 6.7-1 High Pressure Nitrogen Gas Supply System P&ID 21-149

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-9 Reactor Protection System IED (Sheet 1 of 11)21-150

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-9 Reactor Protection System IED (Sheet 2 of 11)21-151

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-9 Reactor Protection System IED (Sheet 3 of 11)21-152

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-9 Reactor Protection System IED (Sheet 4 of 11)21-153

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-9 Reactor Protection System IED (Sheet 5 of 11)21-154

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-9 Reactor Protection System IED (Sheet 6 of 11)21-155

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-9 Reactor Protection System IED (Sheet 7 of 11)21-156

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-9 Reactor Protection System IED (Sheet 8 of 11)21-157

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-9 Reactor Protection System IED (Sheet 9 of 11)21-158

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-9 Reactor Protection System IED (Sheet 10 of 11)21-159

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-9 Reactor Protection System IED (Sheet 11 of 11)21-160

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 1 of 72)21-161

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 2 of 72)21-162

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 3 of 72)21-163

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 4 of 72)21-164

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 5 of 72)21-165

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 6 of 72)21-166

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 7 of 72)21-167

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 8 of 72)21-168

25A5675BC Revision 7 ABWR Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 9 of 72)21-169

ABWR 21-170 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 10 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 11 of 72)21-171

ABWR 21-172 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 12 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 13 of 72)21-173

ABWR 21-174 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 14 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 15 of 72)21-175

ABWR 21-176 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 16 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 17 of 72)21-177

ABWR 21-178 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 18 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 19 of 72)21-179

ABWR 21-180 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 20 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 21 of 72)21-181

ABWR 21-182 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 22 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 23 of 72)21-183

ABWR 21-184 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 24 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 25 of 72)21-185

ABWR 21-186 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 26 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 27 of 72)21-187

ABWR 21-188 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 28 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 29 of 72)21-189

ABWR 21-190 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 30 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 31 of 72)21-191

ABWR 21-192 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 32 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 33 of 72)21-193

ABWR 21-194 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 34 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 35 of 72)21-195

ABWR 21-196 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 36 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 37 of 72)21-197

ABWR 21-198 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 38 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 39 of 72)21-199

ABWR 21-200 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 40 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 41 of 72)21-201

ABWR 21-202 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 42 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 43 of 72)21-203

ABWR 21-204 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 44 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 45 of 72)21-205

ABWR 21-206 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 46 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 47 of 72)21-207

ABWR 21-208 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 48 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 49 of 72)21-209

ABWR 21-210 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 50 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 51 of 72)21-211

ABWR 21-212 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 52 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 53 of 72)21-213

ABWR 21-214 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 54 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 55 of 72)21-215

ABWR 21-216 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 56 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 57 of 72)21-217

ABWR 21-218 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 58 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 59 of 72)21-219

ABWR 21-220 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 60 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 61 of 72)21-221

ABWR 21-222 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 62 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 63 of 72)21-223

ABWR 21-224 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 64 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 65 of 72)21-225

ABWR 21-226 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 66 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 67 of 72)21-227

ABWR 21-228 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 68 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 69 of 72)21-229

ABWR 21-230 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 70 of 72)

ABWR 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 71 of 72)21-231

ABWR 21-232 25A5675BC Revision 7 Design Control Document/Tier 2 Figure 7.2-10 Reactor Protection System IBD (Sheet 72 of 72)