ML121110018

From kanterella
Revision as of 16:06, 6 February 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Examination Report 50-059/OL-12-01, Texas A&M University AGN-201M Reactor
ML121110018
Person / Time
Site: Texas A&M University
Issue date: 04/26/2012
From: Johnny Eads
Division of Policy and Rulemaking
To: Juzaitis R
Texas A&M Univ
Shared Package
ML111600405 List:
References
50-059/OL-12-001
Download: ML121110018 (25)


Text

April 26, 2012 Dr. Raymond J. Juzaitis Nuclear Engineering Department Head Texas A&M University 129 F Zachry Engineering Center Mail Stop 3133 College Station, TX 77843-3133

SUBJECT:

EXAMINATION REPORT NO. 50-059/OL-12-01, TEXAS A&M UNIVERSITY AGN-201M REACTOR

Dear Dr. Juzaitis:

During the week of April 2, 2012, the U.S. Nuclear Regulatory Commission (NRC) administered operator licensing examinations at your Texas A&M University AGN-201M Reactor. The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report at the conclusion of the examination.

In accordance with Title 10 of the Code of Federal Regulations Section 2.390, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Mr. John T. Nguyen, at (301) 415-4007 or via internet e-mail John.Nguyen@nrc.gov.

Sincerely,

/RA/

Johnny H. Eads, Jr., Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.50-059

Enclosures:

1. Examination Report No. 50-059/OL-12-01
2. Written examination cc: Christopher Crouch, Reactor Supervisor cc: w/o enclosures: See next page

Dr. Raymond J. Juzaitis April 26, 2012 Nuclear Engineering Department Head Texas A&M University 129 F Zachry Engineering Center Mail Stop 3133 College Station, TX 77843-3133

SUBJECT:

EXAMINATION REPORT NO. 50-059/OL-11-02, TEXAS A&M UNIVERSITY AGN-201M REACTOR

Dear Dr. Juzaitis:

During the week of April 2, 2012, the U.S. Nuclear Regulatory Commission (NRC) administered operator licensing examinations at your Texas A&M University AGN-201M Reactor. The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report at the conclusion of the examination.

In accordance with Title 10 of the Code of Federal Regulations Section 2.390, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Mr. John T. Nguyen, at (301) 415-4007 or via internet e-mail John.Nguyen@nrc.gov.

Sincerely,

/RA/

Johnny H. Eads, Jr., Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.50-059

Enclosures:

1. Examination Report No. 50-059/OL-12-01
2. Written examination DISTRIBUTION w/ encls.:

PUBLIC PROB r/f RidsNRRDPRPRLB RidsNRRDPRPROB Facility File (CRevelle) O-07 F-08 RidsNRRDPRPRPB ADAMS ACCESSION #: ML121110018 TEMPLATE #:NRR-074 OFFICE PROB:CE IOLB:LA E PROB:BC NAME JNguyen CRevelle JEads DATE 4/16/2012 4/20/2012 4/26/2012 OFFICIAL RECORD COPY

Texas A&M University Docket No. 50-59 cc:

Mayor, City of College Station P.O. Box Drawer 9960 College Station, TX 77840-3575 Governors Budget and Planning Office P.O. Box 13561 Austin, TX 78711 Radiation Program Officer Bureau of Radiation Control Dept. Of State Health Services Division for Regulatory Services 1100 West 49th Street, MC 2828 Austin, TX 78756-3189 Technical Advisor Office of Permitting, Remediation & Registration Texas Commission on Environmental Quality P.O. Box 13087, MS 122 Austin, TX 78711-3087 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

U. S. NUCLEAR REGULATORY COMMISSION OPERATOR LICENSING INITIAL EXAMINATION REPORT REPORT NO.: 50-059/OL-11-02 FACILITY DOCKET NO.: 50-059 FACILITY LICENSE NO.: R-23 FACILITY: TEXAS A&M UNIVERSITY AGN-201M Reactor EXAMINATION DATES: April 4, 2012 SUBMITTED BY: _____/RA/_____________ 04/16/2012_

John T. Nguyen, Chief Examiner Date

SUMMARY

The NRC administered an operator licensing examination to one Senior Reactor Operator (Instant) (SRO-I) candidate and one Reactor Operator (RO) candidate. All candidates passed all portions of their respective examinations.

REPORT DETAILS

1. Examiner:

John T. Nguyen, Chief Examiner, NRC

2. Results:

RO PASS/FAIL SRO PASS/FAIL TOTAL PASS/FAIL Written 1/0 1/0 2/0 Operating Tests 1/0 1/0 2/0 Overall 1/0 1/0 2/0

3. Exit Meeting:

John T. Nguyen, NRC, Examiner Christopher Crouch, Reactor Supervisor, Texas A&M University The chief examiner met with the facility staff to discuss the overall administration of the examination. The examiner did not note any serious weaknesses on the part of the candidates.

ENCLOSURE 1

OPERATOR LICENSING EXAMINATION TEXAS A&M UNIVERSITY AGN-201M Week of April 2, 2012 ENCLOSURE 2

Section A Reactor Theory, Thermodynamics and Facility Operating Characteristics Page 1 QUESTION A.01 [1.0 point]

Which one of the following statements describes on how moderator temperature affects the core operating characteristics?

a. Increase in moderator temperature will increase the neutron multiplication factor due to the resonance escape probability increase.
b. Increase in moderator temperature will decrease the neutron multiplication factor due to the resonance escape probability decrease.
c. Increase in moderator temperature will decrease the neutron multiplication factor due to the fast non leakage probability increase.
d. Increase in moderator temperature will increase the neutron multiplication factor due to the fast non leakage probability decrease.

QUESTION A.02 [1.0 point]

The effective neutron multiplication factor, Keff, is defined as:

a. absorption/(production + leakage)
b. (production + leakage)/absorption
c. (absorption + leakage)/production
d. production/(absorption + leakage)

QUESTION A.03 [1.0 point]

Reactor power is increasing by a factor of 10 every minute. The reactor period is:

a. 65 seconds
b. 52 seconds
c. 26 seconds
d. 13 seconds

Section A Reactor Theory, Thermodynamics and Facility Operating Characteristics Page 2 QUESTION A.04 [1.0 point]

Which ONE of the following conditions will INCREASE the core excess reactivity of a reactor?

a. Increase moderator temperature (Assume negative temperature coefficient)
b. Insertion of a negative reactivity worth experiment
c. Burnout of a burnable poison
d. Fuel depletion QUESTION A.05 [1.0 point]

During the time following a reactor scram, reactor power decreases on an 80 second period, which corresponds to the half-life of the longest-lived delayed neutron precursors, which is approximately:

a. 80 seconds
b. 55 seconds
c. 40 seconds
d. 20 seconds QUESTION A.06 [1.0 point]

Delayed neutrons are produced by:

a. decay of O-16
b. Photoelectric Effect
c. decay of fission fragments
d. directly from the fission process

Section A Reactor Theory, Thermodynamics and Facility Operating Characteristics Page 3 QUESTION A.07 [1.0 point]

An experiment to be placed in the glory hole has been wrapped in cadmium. Which one of the following types of radiation will be most effectively blocked by the cadmium wrapping?

a. Thermal neutrons
b. Fast neutrons
c. Gamma rays
d. X-rays QUESTION A.08 [1.0 point]

Which ONE of the following is the correct amount of reactivity added if the multiplication factor, k, is increase from 0.800 to 0.950?

a. 0.150
b. 0.158
c. 0.188
d. 0.197 QUESTION A.09 [1.0 point]

Which ONE of the following is the MAJOR source of energy released per U-235 fission?

a. Energy of neutrinos
b. Energy of prompt gamma rays
c. Kinetic energy of the fission neutrons
d. Kinetic energy of the decayed fission fragments

Section A Reactor Theory, Thermodynamics and Facility Operating Characteristics Page 4 QUESTION A.10 [1.0 point]

Given the following: excess = 0.60% k/k, Safety rod 1 = 0.80% k/k Safety rod 2 = 0.85% k/k, Coarse control rod = 0.80% k/k Fine control rod =0.10% k/k Calculate the Shutdown Margin specified in the TAMU AGN-201M Technical Specification.

a. 0.65% k/k
b. 1.00% k/k
c. 1.25% k/k
d. 1.75% k/k QUESTION A.11 [1.0 point]

Given a source strength of 200 neutrons per second (N/sec) and a multiplication factor of 0.6, which ONE of the following is the expected stable neutron count rate?

a. 125 N/sec
b. 250 N/sec
c. 400 N/sec
d. 500 N/sec QUESTION A.12 [1.0 point]

Keff is K4 times Y

a. the reproduction factor ()
b. the resonance escape probability (p)
c. the fast fission factor ()
d. the total non-leakage probability (f H th)

Section A Reactor Theory, Thermodynamics and Facility Operating Characteristics Page 5 QUESTION A.13 [1.0 point]

The reactor is on a CONSTANT positive period. Which ONE of the following power changes will take the longest time to complete?

a. 5%, from 95% to 100%
b. 10%, from 80% to 90%
c. 15%, from 15% to 30%
d. 20%, from 60% to 80%

QUESTION A.14 [1.0 point]

By definition, an exactly critical reactor can be made prompt critical by adding positive reactivity equal to:

a. the shutdown margin
b. the Kexcess margin
c. the eff value
d. 1.0 %K/K QUESTION A.15 [1.0 point]

Delayed neutrons comprise approximately what percent of all neutrons produced in the reactor?

a. 0.65%
b. 1.3%
c. 6.5%
d. 20%

Section B Normal and Emergency Operating Procedures and Radiological Controls Page 6 QUESTION B.01 [1.0 point]

The radiation from an unshielded Co-60 source is 500 mrem/hr. What thickness of lead shielding will be needed to lower the radiation level to 5 mrem/hr? The HVL (half-value-layer) for lead is 6.5 mm.

a. 15 mm
b. 26 mm
c. 33 mm
d. 43 mm QUESTION B.02 [1.0 point]

A radioactive source reads 35 Rem/hr on contact. Five hours later, the same source reads 1.5 Rem/hr.

What will the sample read in another five hours?

a. 55 mrem
b. 65 mrem
c. 75 mrem
d. 120 mrem QUESTION B.03 [1.0 point]

A room contains a source which, when exposed, results in a general area dose rate of 175 millirem per hour. This source is scheduled to be exposed continuously for 35 days. Select an acceptable method for controlling radiation exposure from the source within this room.

a. Lock the room to prevent inadvertent entry into the room
b. Post the area with the words "Danger-Radiation Area"
c. Equip the room with a motion detector that will alarm in the control room
d. Equip the room with a device to visually display the current dose rate within the room

Section B Normal and Emergency Operating Procedures and Radiological Controls Page 7 QUESTION B.4 [1.0 point]

The special unit for absorbed dose Rem is defined in 10 CFR Part 20 in terms of a dose equivalent.

What does the term dose equivalent relate to?

a. It is derived by accounting for the amount of radioactive material taken into the body of an adult worker by inhalation or ingestion in one year
b. It is equal to the absorbed dose (rad) multiplied by the quality factor (Q) of the radiation
c. It is equal to the absorbed dose (rad) divided by the quality factor (Q) of the radiation
d. It is the equivalent dose one would receive during the 50-year period following intake QUESTION B.05 [1.0 point]

Which ONE of the following is the definition of site boundary for the TAMU AGN-201M reactor facility?

a. Reactor room (Room 61B) only
b. Reactor room and Accelerator room
c. Entire Zachary Engineering building
d. Nuclear Engineer laboratory areas 60/61 and 133/134/135 QUESTION B.06 [2.0 point, 0.5 each]

Identify each of the following as a Safety Limit (SL), Limiting Safety System Setting (LSSS), or a limiting Condition for Operation (LCO).

a. The reactor power level shall not exceed 100 watts
b. The maximum core temperature shall not exceed 200°C during either steady state or transient operation
c. The shutdown margin with the most reactive safety or control rod fully inserted shall be at least 1% k/k
d. The core thermal fuse shall melt when heated to a temperature of 120°C or less resulting in core separation and a reactivity loss greater than 5% k/k

Section B Normal and Emergency Operating Procedures and Radiological Controls Page 8 QUESTION B.07 [1.0 point]

Per TAMU 201-M Technical Specifications, what are the MINIMUM staffing requirements for reactor operations during a normal startup?

a. 1 RO on console and 1 knowledgeable person in the facility
b. 1 RO on console, 1 knowledgeable person in the facility, and 1 SRO on-call
c. 2 RO on console and 1 knowledgeable person in the facility
d. 1 SRO on console and the Reactor Director on campus QUESTION B.08 [1.0 points, 0.25 each]

Identify each of the following surveillances as a channel check (CHECK), a channel test (TEST), or a channel calibration (CAL).

a. During performance of the Daily Checklist, you depress the Test Rate Meter to verify the Channel
  1. 1 reading
b. During reactor operation, you compare the readings of Channel 1 and Channel 2
c. Drive the source to the inner limit and verify that the IN light is illuminated
d. Adjust the Log Power channel in accordance with recent data collected on the reactor power calibration QUESTION B.09 [1.0 point]

What is the exposure rate at 1 ft from 2-curie Co-60 source? Co-60 emits two gamma photons per decay with energies of 1.17 Mev and 1.33 Mev.

a. 3 R/hr
b. 5 R/hr
c. 6 R/hr
d. 30 R/hr

Section B Normal and Emergency Operating Procedures and Radiological Controls Page 9 QUESTION B.10 [1.0 point]

An area in which radiation levels could result in an individual receiving a dose equivalent of 120 mRem/hr at 30 cm is defined as:

a. Radiation area
b. Unrestricted Area
c. High Radiation Area
d. Very High Radiation Area QUESTION B.11 [1.0 point]

Per TAMU 201-M Technical Specifications, what is the MINIMUM level of supervision requirements for a modification which could affect the reactivity of the reactor?

a. Reactor Operator in duty
b. Senior Reactor Operator on call
c. Senior Reactor Operator in duty
d. Reactor Supervisor QUESTION B.12 [1.0 point]

Which ONE of the following materials shall NOT be irradiated at TAMU 201-M reactor?

a. corrosive material
b. explosive material
c. fissionable material
d. gaseous experiment QUESTION B.13 [1.0 point]

Safety and control rod reactivity worths shall be measured:

a. semi-annually
b. annually
c. every two years
d. every five years

Section B Normal and Emergency Operating Procedures and Radiological Controls Page 10 QUESTION B.14 [1.0 point]

Assume that there is no leak from outside of the radiation waste container. You use a survey instrument with a window probe to measure the dose rate from the shield. Compare to the reading with a window CLOSED, the reading with a window OPEN will :

a. increase, because it can receive an additional alpha radiation from (Al-27) (n,), (Na-24) reaction
b. remain the same, because the Quality Factors for gamma and beta radiation are the same
c. increase, because the Quality Factor for beta and alpha is greater than for gamma
d. remain the same, because the survey instrument would not be detecting beta and alpha radiation from the container

Section C Facility and Radiation Monitoring Systems Page 11 QUESTION C.01 [1.0 point]

Which one of the following detectors is used for Nuclear Instrumentation Channel #1?

a. BF3 filled Proportional Counter
b. BF3 filled Ionization Chamber
c. BF3 filled Geiger-Muller tube
d. U235 lined Fission Chamber QUESTION C.02 [1.0 point, 0.25 each]

Match the input signals listed in column A with their respective responses listed in column B. (Items in column B may be used more than once or not at all.)

Column A Column B

a. Count rate = 9 cps 1. Indication only (Nuclear Safety # 1)
2. scram
b. Reactor period = 30 sec
c. Linear Power = 10 watts 3. interlock
d. Try to move coarse control rod when both safety rods are fully down QUESTION C.03 [1.0 point]

The MAIN purpose of the thermal fuse is to:

a. measure the temperature of fuel core
b. measure any gases released from the fuel core
c. separate the reactor core to prevent exceeding the Safety Limit (SL)
d. send a scram signal to the Nuclear Safety # 2 if Limiting Safety System Setting (LSSS) is exceeded

Section C Facility and Radiation Monitoring Systems Page 12 QUESTION C.04 [1.0 point]

Which ONE of the following is the MAIN function of the high density graphite surrounding the reactor core?

a. To absorb thermal neutrons
b. To reduce neutron leakage
c. To absorb fission product gases
d. To reduce prompt gamma rays QUESTION C.05 [1.0 point]

What is the maximum acceptable time between the initiation of a scram signal and the time that the SAFETY rods are fully withdrawn from the core?

a. 500 msec
b. 200 msec
c. 100 msec
d. 50 msec QUESTION C.06 [1.0 point]

The calibration curve (see Figure attached) for the Fine Control rod depicts:

a. Rod Drop Worth curve
b. Integral Rod Worth curve
c. Differential Rod Worth curve
d. Thermal Power Calibration curve QUESTION C.07 [1.0 point]

Which ONE of the following is the design features for the TAMU AGN-201M Core?

a. The reactor consists of 9 fuel disc with less than 20% U-235 enrichment
b. The reactor consists of 9 fuel disc with less than 30% U-235 enrichment
c. The reactor consists of 9 TRIGA fuel elements with less than 20% U-235 enrichment
d. The reactor consists of 9 TRIGA fuel elements with less than 30% U-235 enrichment

Section C Facility and Radiation Monitoring Systems Page 13 Section C Facility and Radiation Monitoring Systems Page 14 Section C Facility and Radiation Monitoring Systems Page 15 QUESTION C.08 [1.0 point]

How does the control rod position indicator measure rod height?

a. A radio frequency detector measures the height of the control rod extension tube above the piston
b. A series of 1000 limit switches open and close as the rod moves in giving rod position to 0.1%

accuracy

c. A laser distance meter attached to top of control rod drive measures the height of the control rod
d. A synchronic generator attached to the control rod drive motor generates a signal proportional to rod position QUESTION C.09 [1.0 point]

Per Procedure for Power Calibration, PWCL-3, the reactor operator will bring the power to:

a. 1 watts and a gold foil is used for the power calibration
b. 2 watts and a nickel foil is used for the power calibration
c. 5 watts and a gold foil is used for the power calibration
d. 7.5 watts and a nickel foil is used for the power calibration QUESTION C.10 [1.0 point]

Which ONE of the following is the source presently used in the AGN-201M reactor?

a. Americium-Beryllium (Am-Be)
b. Plutonium-Beryllium (Pu-Be)
c. Radon-Beryllium (Ra-Be)
d. Uranium-Beryllium (U-Be)

Section C Facility and Radiation Monitoring Systems Page 16 QUESTION C.11 [1.0 point]

During a reactor operation, you observe that the shield water temperature indicates 14 ° C. For this temperature, you should:

a. continue to operate because the shield water temperature is within TS limit
b. increase power to 5 W so you can observe the temperature change
c. shutdown the reactor; immediately report the result to Reactor Manager because the control and safety system signals do not work
d. continue operation, but immediately report the result to the Senior Reactor Operator since the temperature is exceeding the facility operation limit QUESTION C.12 [1.0 point]

Before setting High Voltage to Safety Channel, the first thing the Reactor Operator needs to do is to:

a. Insert in-core startup source
b. Set Safety Channel to 1 x 10 -12
c. Turn off Safety Channel High alarm
d. Verify that the cadmium shutdown rod is inserted in the glory hole QUESTION C.13 [1.0 point]

In the event the reactor fails to scram, the TWO design features that serve to prevent exceeding core temperature limits are the:

a. large temperature coefficient and volume of water shield
b. Glory Hole Cadmium plug and volume of water shield
c. thermal fuse and large temperature coefficient
d. Glory Hole Cadmium plug and thermal fuse

Section A Reactor Theory, Thermodynamics and Facility Operating Characteristics Page 17 A.01 Answer: b

Reference:

Burn, R., Introduction of Nuclear Reactor Operations, © 1982, Sec 3.3.1 A.02 Answer: d

Reference:

Burn, R., Introduction of Nuclear Reactor Operations, © 1982, Sec 3.3.1 A.03 Answer: c

Reference:

P=Poet/ J = 60 sec/ln(10) = 26.06 sec A.04 Answer: c

Reference:

Standard NRC question A.05 Answer: b

Reference:

Group 1 is the longest-lived delayed neutron precursor for thermal fission in U-235, with a half-life of 55.72 sec. Lamarsh, J. Introduction to Nuclear Engineering p. 88 A.06 Answer: c

Reference:

Burn, R., Introduction of Nuclear Reactor Operations, © 1982, Sec 3.2.1 A.07 Answer: a

Reference:

NRC Standard Question.

A.08 Answer: d

Reference:

Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Sec 3.3.3, page 3-21. At k=0.8; = Keff/Keff or = Keff-1/Keff = -0.2/0.8 =-0.25. At k=0.95, =-0.05/0.95

= -0.053. The difference between is the answer ,i.e. -0.053-(-0.25)=0.197 A.09 Answer: d

Reference:

Burn, R., Introduction of Nuclear Reactor Operations, © 1982, Sec 3.2 A.10 Answer: b

Reference:

Total rod worth - (excess + most active control rod+ fine control rod);

(0.80+0.85+0.80+0.10) %k/k -(0.60+0.85+0.10) %k/k = (2.55 -1.55) %k/k = 1.00 %k/k A.11 Answer: d

Reference:

CR = S/(1-K) CR = 200/(1 - .6) = 500 A.12 Answer: d

Reference:

DOE Handbook Vol 2, L Theory (Nuclear Parameters), E.O. 1.1 a&b, pg. 9

Section A Reactor Theory, Thermodynamics and Facility Operating Characteristics Page 18 A.13 Answer: c

Reference:

Time is related to ratio of final power to initial power. 2:1 is the largest ratio.

A.14 Answer: c

Reference:

DOE Fundamentals Handbook, Nuclear Physics and Reactor Theory.

A.15 Answer: a.

Reference:

DOE Fundamentals Handbook, Nuclear Physics and Reactor Theory, Volume 2

Section B Normal and Emergency Operating Procedures and Radiological Controls Page 19 B.1 Answer: d

Reference:

DR = DR*e -X HVL ( =6.5 mm) means the original intensity will reduce by half when a lead sheet of 6.5 mm is inserted.

Find if the HVL is given as follows: 1 = 2* e -*6.5 ; = 0.10664. Find X: 5 mrem/hr = 500 mrem/hr* e -

0.10664*X

X= 43.2 mm B.2 Answer
b

Reference:

DR = DR*e -t 1.5 rem/hr =35 rem/hr* e -(5hr)

Ln(1.5/35) = -*5 --> =0.623; solve for another 5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> later, DR DR=1.5 Rem* e -0.623*(5)

DR=6.6*10 -2 Rem or ~65 mrem B.3 Answer: a

Reference:

10CFR20.1601(a)(3)

B.4 Answer: b

Reference:

10CFR20.1003 and NRC Training Material B.05 Answer: d

Reference:

Emergency Plan 2.2 B.06 Answer: a. = SL, b. = SL; c. = LCO; d. = LSSS;

Reference:

TS 2.1- 2.3 B.07 Answer: b

Reference:

Tech Spec 6.1.9 B.8 Answer: a, TEST b,CHECK c,TEST d, CAL

Reference:

TS 1.0 B.9 Answer: d

Reference:

R/hr = 6CE = 6 x 2 x 1*(1.17+1.33) = 30 R/hr B.10 Answer: c

Reference:

10 CFR 20 B.11 Answer: c

Reference:

TS 6.1.9

Section B Normal and Emergency Operating Procedures and Radiological Controls Page 20 B.12 Answer: b

Reference:

TS 3.3 B.13 Answer: b

Reference:

TS 4.1.b B.14 Answer: d

Reference:

Basic knowledge of radiation.

Section C Facility and Radiation Monitoring Systems Page 21 C.01 Answer: a

Reference:

TAMU AGN-201M Safety Analysis Report § 7.2.3.

C.02 Answer: a, 2; b, 1; c, 2; d, 3

Reference:

TAMU AGN-201M Technical Specifications 3.3 C.03 Answer: c

Reference:

TAMU AGN-201M Safety Analysis Report § 4.5.3.

C.04 Answer: b

Reference:

TAMU AGN-201M Safety Analysis Report § 4.2.3 C.05 Answer: b

Reference:

TAMU AGN-201M Technical Specifications 3.2 C.06 Answer: b

Reference:

TAMU AGN-201M Safety Analysis Report § Figure 4-4.

C.07 Answer: a

Reference:

TAMU AGN-201M Safety Analysis Report § 4.2.1 C.08 Answer: d

Reference:

Per pre-examination orientation, July, 2011.

C.9 Answer: c

Reference:

PWCL-3 C.10 Answer: b

Reference:

TAMU AGN-201M Safety Analysis Report § 4.2.4 C.11 Answer: c

Reference:

TS 3.2.f C.12 Answer: d

Reference:

Maintenance Procedure for Setting Channel Two High Voltage (CH2P-3)

C.13 Answer: c

Reference:

TS 2.2.b

U. S. NUCLEAR REGULATORY COMMISSION RESEARCH AND TEST REACTOR OPERATOR LICENSE EXAMINATION FACILITY: Texas A&M University REACTOR TYPE: AGN-201M DATE ADMINISTERED: 4/4/2012 CANDIDATE:

INSTRUCTIONS TO CANDIDATE:

Answers are to be written on the answer sheet provided. Attach the answer sheets to the examination.

Points for each question are indicated in brackets for each question. A 70% in each section is required to pass the examination. Examinations will be picked up three (3) hours after the examination starts.

% of Category % of Candidates Category Value Total Score Value Category 15.00 33.3 A. Reactor Theory, Thermodynamics and Facility Operating Characteristics 15.00 33.3 B. Normal, Emergency and Radiological Controls Procedures 13.00 33.3 C. Facility and Radiation Monitoring Systems 43.00  % TOTALS FINAL GRADE All work done on this examination is my own. I have neither given nor received aid.

Candidate's Signature

NRC RULES AND GUIDELINES FOR LICENSE EXAMINATIONS During the administration of this examination the following rules apply:

1. Cheating on the examination means an automatic denial of your application and could result in more severe penalties.
2. After the examination has been completed, you must sign the statement on the cover sheet indicating that the work is your own and you have neither received nor given assistance in completing the examination. This must be done after you complete the examination.
3. Restroom trips are to be limited and only one candidate at a time may leave. You must avoid all contacts with anyone outside the examination room to avoid even the appearance or possibility of cheating.
4. Use black ink or dark pencil only to facilitate legible reproductions.
5. Print your name in the blank provided in the upper right-hand corner of the examination cover sheet and each answer sheet.
6. Mark your answers on the answer sheet provided. USE ONLY THE PAPER PROVIDED AND DO NOT WRITE ON THE BACK SIDE OF THE PAGE.
7. The point value for each question is indicated in [brackets] after the question.
8. If the intent of a question is unclear, ask questions of the examiner only.
9. When turning in your examination, assemble the completed examination with examination questions, examination aids and answer sheets. In addition turn in all scrap paper.
10. Ensure all information you wish to have evaluated as part of your answer is on your answer sheet.

Scrap paper will be disposed of immediately following the examination.

11. To pass the examination you must achieve a grade of 70 percent or greater in each category.
12. There is a time limit of three (3) hours for completion of the examination.
13. When you have completed and turned in you examination, leave the examination area. If you are observed in this area while the examination is still in progress, your license may be denied or revoked.

Section A: Theory, Thermodynamics & Facility Operating Characteristics Page 1 ANSWER SHEET Multiple Choice (Circle or X your choice)

If you change your Answer, write your selection in the blank.

A01 a b c d ___

A02 a b c d ___

A03 a b c d ___

A04 a b c d ___

A05 a b c d ___

A06 a b c d ___

A07 a b c d ___

A08 a b c d ___

A09 a b c d ___

A10 a b c d ___

A11 a b c d ___

A12 a b c d ___

A13 a b c d ___

A14 a b c d ___

A15 a b c d ___

Section B: Normal, Emergency & Radiological Controls Procedures Page 2 ANSWER SHEET Multiple Choice (Circle or X your choice)

If you change your Answer, write your selection in the blank.

B01 a b c d ___

B02 a b c d ___

B03 a b c d ___

B04 a b c d ___

B05 a b c d ___

B06 a ___ b ___ c ___ d ___ (2 points,0.5 each)

B07 a b c d ___

B08 a ___ b ___ c ___ d ___ (1 point, 0.25 each)

B09 a b c d ___

B10 a b c d ___

B11 a b c d ___

B12 a b c d ___

B13 a b c d ___

B14 a b c d ___

Section C Facility and Radiation Protection Systems Page 3 ANSWER SHEET Multiple Choice (Circle or X your choice)

If you change your Answer, write your selection in the blank.

C01 a b c d ___

C02 a ___ b ___ c ___ d ___

C03 a b c d ___

C04 a b c d ___

C05 a b c d ___

C06 a b c d ___

C07 a b c d ___

C08 a b c d ___

C09 a b c d ___

C10 a b c d ___

C11 a b c d ___

C12 a b c d ___

C13 a b c d ___

EQUATION SHEET

Pmax =

( )2 eff = 0.1sec 1 Q& = m& c P T = m& H =UAT (2 l )

t P = P0 e S S SCR = l* =1x10 4 sec 1 K eff eff + &

SUR = 26 .06

( ) (

CR1 1 K eff1 = CR2 1 K eff 2 ) CR1 ( 1 ) = CR2 ( 2 )

(1 ) M=

1

= 2 CR P = P0 10SUR(t )

P= P0 1 K eff CR1 1 K eff1 1 K eff l*

M= SDM = =

1 K eff 2 K eff l* 0.693 K eff 2 K eff1

+ T1 =

eff + & 2 K eff1 K eff 2 K eff 1

= DR = DR0 e t 2 DR1 d1 = DR2 d 2 2

K eff 6 Ci E (n ) ( 2 )2 = (1 )2 DR =

R2 Peak2 Peak1 6

( 2.3x10 yr )

DR - Rem, Ci - curies, E - Mev, R - 135 52Te ( 19 sec) 135 ( 6.6 hr ) 135 ( 9.1 hr ) 135 53 I 54 Xe 55 Cs 56 Ba 135 feet 1 Curie = 3.7 x 1010 dis/sec 1 kg = 2.21 lbm 1 Horsepower = 2.54 x 103 BTU/hr 1 Mw = 3.41 x 106 BTU/hr 1 BTU = 778 ft-lbf EF = 9/5 EC + 32

1 gal (H2O) . 8 lbm EC = 5/9 (EF - 32) cP = 1.0 BTU/hr/lbm/EF cp = 1 cal/sec/gm/EC