ML063400488

From kanterella
Revision as of 12:34, 23 November 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Final Status Survey Final Report Phase IV, Appendix A9, Survey Unit Release Record 9106-0009, Discharge Canal
ML063400488
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/15/2006
From: Newson C
Yankee Atomic Electric Co
To:
NRC/FSME
References
9106-0009
Download: ML063400488 (224)


Text

IN m :1ook10] of 17!m Or r

kA Final Status Survey Final Report Phase IV Appendix A9 Survey Unit Release Record 9106-0009, Discharge Canal November 2006

CYAPCO FINAL STATUS SURVEY RELEASE RECORD DISCHARGE CANAL SURVEY UNIT 9106-0009 Prepared By: Date: _ -_ -__

FSS Engineer ._

Reviewed By: Date:

Approved By//f 4,( c. ,/val,, Date: /1///* /

Techni'cal Support Manager Revision 0

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD TABLE OF CONTENTS

1. SURVEY UNIT DESCRIPTION ................................................................. 3
2. CLASSIFICATION BASIS ...................................................................... 3
3. DATA QUALITY OBJECTIVES (DQO) .................................................... 5
4. SURVEY DESIG N ..................................................................................... 8
5. SURVEY IMPLEMENTATION ................................................................ 11
6. SURVEY RESULTS ............................................................................... 12
7. QUALITY CONTROL ............................................................................. 14
8. INVESTIGATIONS AND RESULTS ...................................................... 14
9. REMEDIATION AND RESULTS ............................................................. 15
10. CHANGES FROM THE FINAL STATUS SURVEY PLAN ..................... 15
11. DATA QUALITY ASSESSMENT (DQA) ................................................. 15
12. A NO MA LIES ........................................................................................... 16
13. CO NCLUSIO N ....................................................................................... 16
14. ATTACHM ENTS ..................................................................................... 17 14.1 Attachment 1 - Figures (6 pages including cover) 14.2 Attachment 2 - Sample and Statistical Data (200 pages including covers)

Revision 0

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9106-0009 (Discharge Canal) is designated as Final Status Survey (FSS) Class 2 and consists of approximately 9,933 m2 (2.45 acres) of water covered sediment in an area located approximately 1.02 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (HNP)

(see Attachment 1, Figure 1). The Discharge Canal is a man-made mile long waterway that runs parallel to, and ultimately communicates with, the Connecticut River. The Discharge Canal is subdivided into fifteen (15) survey units including two (2) permanent wetland areas for FSS purposes. The survey unit is bounded as follows: Discharge Canal Survey Unit 9106-0008 is to the north (called north as orientated with the north to south flow of the Connecticut River), Survey Area 9523 is to the east, Discharge Canal Survey Unit 9106-0010 is to the south and South Peninsula Survey Area 9531 (formerly a part of 9530) is to the west. The survey unit comprises the canal sediments to the deeper of three (3) feet or the original construction depth and it extends up the canal banks to the mean high water level.

The reference coordinates associated with this survey unit are E018 through E027 by S148 through S161 (refer to License Termination Plan Section 5.4.4).

The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification." The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9106-0009 as Class 2 in May 2006.

The "Classification Basis Summary" conducted for this survey unit consisted of:

a) A review of the IOCFR50.75 (g) (1) database, b) A review of the "InitialCharacterizationReport" and the "HistoricSite Assessment (HSA) Supplement, "

c) Historic and current survey records review, d) Visual inspections and a "walkdown."

e) Formal or informal interviews with cognizant personnel.

A review of the 10CFR50.75(g)(1) database report identified a number of events that may have impacted this survey unit. In 1986, samples were taken from the legacy dredge spoils removed in 1979 dredged spoils area and from recently dredged canal sediment. The sample analyses indicated that the Revision 0 3 Revision 0 3

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD concentrations of Cs-137, Co-60 and other radionuclides were a small fraction of the DCGLs for those nuclides that could be identified by gamma spectroscopy. (refer to NE-86-RA-1142 dated 11-13-86). None the available historical information reviewed would support a conclusion that any residual activity in this survey unit is likely to be present at concentrations greater than the respective DCGLs Additional information was provided by several historical documents, including the "Results of Scoping Survey", (completed 9/1/98), the "Historical Site Assessment", and the HSA Supplement (dated 6-30-00). These documents presented the results of several sediment samples taken in 1997. These sample results indicated concentrations of 0.5 pCi/g for Co-60, 0.024pCi/g for Cs-134 and 0.722 pCi/g for Cs-137.

An initial characterization survey was implemented during April and May of 2004. Six (6) samples from three (3) locations were obtained by biased sampling throughout the area. The samples were analyzed off-site by gamma spectroscopy and with radiochemical analyses for Sr-90 and Tritium. Hard-to-Detect analyses were also conducted on one (1) of the six (6) samples. The only plant-related dosimetrically significant radionuclides identified in the samples were Cs-137, Cobalt-60 and Ni-63. No samples indicated radioactive material in quantities above the ten (10) mrem/yr design DCGL. Cobalt-60 accounted for the majority of the dose in these samples with a maximum concentration of 0.57 pCi/g.

A final characterization was performed by Site Closure personnel in April of 2006. Six (6) sediment samples from six (6) locations were taken. All of the samples were analyzed by gamma spectroscopy. Based on the initial and final characterization results, the radionuclides of concern identified in the sample data for FSS planning purposes were Cesium-137, Cobalt-60 and Ni-63. Since HTD analyses were not performed for all radionuclides of interest during characterization, additional HTD analyses were performed as a part of the FSS.

The statistics for each of the radionuclides of concern are listed in Table 1.

Revision 0 4

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD iviinimum vaiue: i .VL-IJ - 1.&4t-uz - I .oL-1-uu Maximum Value: 4.24E-01 3.82E-01 3.47E+01 Mean: 1.34E-01 1.1 7E-01 1.65E+01 Median: 9.43E-02 8.56E-02 1.65E+01 Standard Deviation: 1.58E-01 1.41 E-0 1 2.57E+0 I NOTE: The Operational DCGLs are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 549 pCi/g for Ni-63; these are used in conjunction with the unity rule to achieve nineteen (19) mrem/yr TEDE The FSS Engineer performed a visual inspection and walk-down during May 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGLs justifying a final survey unit classification of Class 2 (refer to Section 3).

3. DATA QUALITY OBJECTIVES (DQO)

FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparationof Final Status Survey Plan," and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would satisfy the release criteria objective of the FSS.

The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9106-0009 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

Revision 0 5 Revision 0 5

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of Derived Concentration Guideline Levels (DCGLs). The DCGLs represent the concentration of radioactivity above background, equivalent to a dose-based release criterion and is presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL),

for existing groundwater radioactivity and for future groundwater radioactivity that will be contributed by building foundations and footings.

As described in detail in the LTP, the dose model applied to the discharge canal presumes that the canal sediments are dredged to a depth of three (3) feet below the top of the sediment layer and spread for the planting of crops per the Resident Farmer Scenario. Consequently, the soil DCGLs are directly applied to the canal sediment media.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity. Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation 1:

HTotai=Hsoil (sediment) +/- HExisting GW +/- HFuture GW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from sediment must be reduced when using the existing and future groundwater dose values discussed above.

This survey unit is not affected by either existing groundwater or by future groundwater (reference CY memo ISC 06-024). Therefore, dose contribution from both existing and future groundwater is zero (0) mrem/yr TEDE, based on field data.

Equation 2.

19 mrem/yrTotal= 19 mrem/yrso 0 j+0 mrem/yrExisting GW+O mrem/yrFuture GW The allowable dose for sediment in this survey unit is nineteen (19) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in nineteen (19) mrem/yr TEDE is designated as the Revision 0 6 Revision 0 6

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.

Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.

Table 2 - Radionuclide Specific Base Case Soil CG3L, Operatiokal DCGLs

~Radioniuclide ()UBase Case Soil Operational DCGL ~Required MiC~

DCGL (pCiig) () (I)Ci g) (3 (4 H-3 4.12E+02 3.131E+02 1.65E+01 C-14 5.66E+00 4.30E+00 2.26E-01 Mn-54 1.74E+O1 1.32E+01 6.96E-01 Fe-55 2.74E+04 2.08E+04 1.1OE+03 Co-60 3.81 E+00 2.90E+00 1.52E-0 I Ni-63 7.23E+02 5.49E+02 2.89E+O1 Sr-90 1.55E+00 1.1 8E+00 6.20E-02 Nb-94 7.12E+00 5.41 E+00 2.85E-0 1 Tc-99 1.26E+O1 9.58E+00 5.04E-01 Ag-108m 7.14E+00 5.43E+00 2.86E-01 Cs-134 4.67E+00 3.55E+00 1.87E-01 Cs-137 7.91E+00 6.01E+00 3.16E-01 Eu- 152 1.01 E+01 7.68E+00 4.04E-01 Eu-154 9.29E+00 7.06E+00 3.72E-01 Eu-155 3.92E+02 2.98E+02 1.57E+01 Pu-238 2.96E+01 2.25E+01 1.18E+00 Pu-239/240 2.67E+01 2.03 E+01 I1.07E+00 Pu-241 8.70E+02 6.61E+02 3.48E+01 Am-241 (5) 2.58E+01 1.96E+O 1.03E+00 Cm-243/244 2.90E+OI 2.20E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)

(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE (3) The Operational DCGL is equivalent to nineteen (19) mrem/yr TEDE (4) The required MDC is equivalent to one (1) mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Revision 0 7 Revision 0 7

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Characterization was completed in April of 2006 as discussed in Section 2. Cesium-137, Cobalt-60 and Nickel-63 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137, Co-60 and Ni-63 are provided in Table 1.

Laboratory DQOs and analysis results were to be reported as actual calculated results. Results reported as less than Minimum Detectable Concentration

(<MDC) would not be accepted for FSS. Sample report summaries were to include unique sample identification, analytical method, radionuclide, result, and uncertainty of two standard deviations, laboratory data qualifiers, units, and the required and observed MDC.

4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans".

This survey was initially designed to ten (10) mrem/yr TEDE. At the time when the survey was designed, the dose contribution for existing and future groundwater had not yet been determined. Subsequently, a conservative value was chosen for the Operational DCGL. This approach is no longer required as the total dose from existing and future groundwater has been established. The dose for soil used for this survey unit to demonstrate compliance with the LTP criteria is nineteen (19) mrem/yr TEDE, as discussed in Section 2 of this Release Record.

The DQO process determined that Cs-137, Co-60 and Ni-63 were the radionuclides of concern (refer to Section 3). The sum of fractions or unity rule was used with the individual Operational DCGLs because multiple radionuclides (Cs-137, Co-60 and Ni-63) were considered in the survey design.

Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening process described in LTP Section 5.4.7.2, "Gross Activity DCGLs". Ni-63 concentrations in sediment and soil were ascertained by direct analysis.

Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations that are less than 5%

for individual radionuclides and that are less than 10% for the aggregate of all radionuclides that are de-selected. This process was applied to analysis data for this survey unit.

Revision 0 8 Revision 0 8

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD The Elevated Measurement Comparison (EMC) did not apply to this survey unit since the survey unit is a Class 2 and discrete, elevated areas of contamination were not expected.

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. This approach was conservative since it included background Cs-137 as part of the sample set.

The number of sediment samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Samples for Final Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.724 to maintain the relative shift (A/o) in the range of 1 and 3. The resulting relative shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.

This indicates that the survey unit has a high probability of rejecting the null hypothesis, assuming that the characterization data are representative of the FSS results. Survey design specified fifteen (15) sediment core samples for non-parametric statistical testing.

The grid pattern and locations of the sediment samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey. "

Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

Revision 0 9 Revision 0 9

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Table 3 -Sample&Muasurerne2nt Locations with iAssociated GPS C~oordinates' signtlonNorthing., FEasting, 9106-0009-001F 234282.36 673022.88 9106-0009-002F 234282.36 673113.80 9106-0009-003F 234203.62 673068.34 9106-0009-004F 234203.62 673159.25 9106-0009-005F 234124.88 673113.80 9106-0009-007F 234046.15 673159.25 9106-0009-008F 233967.41 673113.80 9106-0009-009F 233967.41 673204.71 9106-0009-01 OF 233888.68 673159.25 9106-0009-011 F 233888.68 673250.17 9106-0009-013F 233809.94 673204.71 9106-0009-014F 233731.21 673159.25 9106-0009-015F 233731.21 673250.17 9106-0009-016F 234078.97 673143.18 9106-0009-017F 234023.32 673157.00 The sample location designations of Table 3 are not sequentially inclusive because of the necessity to relocate some samples due to the accessibility of the original sample locations. Samples locations 9106-0009-006F and 9106-0009-01 2F were found to be on dry land, consequently, they were randomly relocated using the VSP software to two (2) new locations designated as 9106-0009-016F and 9106-0009-017F. Since sample 9106-0009-006F was randomly selected as a Quality Control (QC) split sample, 9106-0009-016F was designated as the replacement QC sample.

Four (4) sediment samples were analyzed for the full suite of radionuclides specified in Table 1, exceeding the requirement to analyze 5% of the sample population for HTD analysis specified in procedure RPM 5.1-11. Two (2) of the four (4) samples were randomly selected using the Microsoft Excel "RAND" function. The two (2) samples exhibiting the highest observed radionuclide concentrations by gamma analyses were also selected.

The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, " required the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RAND" function. The number of quality control samples exceeded the 5%

requirement as specified by the LTP.

Section 5.7.3.2.6 of the LTP specifies that scanning is not required for the FSS of the Discharge Canal. Table 4 provides a synopsis of the survey design.

Revision 0 10 Revision 0 10

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD liable Tci 4 -§Svn-osis of the Suiw esln  :

<Feature Des~ig 1 riterili i< Basis>>

Survey Unit Land m2 Based on AutoCAD-LT and Visual Area Sample Plan calculations Type I and Type 2 errors were 0.05, Number of 15 sigma was 0.138 the LBGR was set to Measurements 0.724 to maintain Relative Shift in the range of I and 3, Relative Shift was 2.0 Grid Spacing 27.4 m Based on triangular grid 3.16 pCi/g Cs-137 Design DCGL 1.52 pCi/g Co-60 To achieve ten (10) mrem/yr TEDE 289 pCi/g Ni-63 Operational 6.01 pCi/g Cs-137 To achieve nineteen (19) mrem/yr DCGL 2.90 pCi/g Co-60 TEDE (2)to demonstrate compliance

_ __ _ 549 pCi/g Ni-63 with Equation 2 of this Release Record Scan Coverage N/A The LTP exempts this area Sediment 6.01 pCi/g Cs-137 The Operational DCGL meets the LTP Investigation 2.90 pCi/g Co-60 criteria for a Class 2 survey unit Level 549 pCi/g Ni-63 (1) The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 as the total dose from existing and future groundwater had not been established at the time of planning the FSS

5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0021. The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates that were supplied to the sampling vendor, Ocean Survey, Inc.

(OSI) of Old Saybrook, Connecticut. Discharge Canal sampling was accomplished using direct push technology to collect composite samples of bottom and mean high water mark sediments. Sediment cores from the Discharge Canal were obtained by OSI using a vibrating corer that is platform mounted on a sampling vessel. The core barrel was a three (3) inch diameter thin-walled aluminum tube which also served as a core liner (ten (10) feet or less). A core catcher was available to prevent the sample from sliding out of the bottom of the tube. Vessel positioning and the determination of sample locations were accomplished using a GPS interfaced with a navigation and data logging system.

After extraction, water was drained from above the sample by drilling holes above the sediment. The liner was cut, capped, sealed, labeled and turned over Revision 0 I1I Revision 0 11

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD to site personnel who processed and controlled the samples under Chain of Custody (COC) protocols in accordance with procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples." Rinsing of the barrel and associated equipment was performed between sampling events. New aluminum tubes were used for each sample to prevent cross-contamination of subsequent samples.

The fifteen (15) sediment samples were collected and packaged in accordance with Haddam Neck Plant (I-INP) Procedure RPM 5.1-3, "Collection of Sample Mediafor Final Status Survey". Samples were controlled, transported, stored, and transferred to the off-site laboratory using COC protocols.

Four (4) samples (9106-0009-002F, 9106-0009-01 IF, 9106-0009-014F and 9106-0009-017F) were selected for HTD radionuclide analysis by the off-site laboratory. Two (2) of these samples (011F and 014F) were selected at random. The other two (2) were selected based of being the most dosimetrically significant samples based on spectroscopic gamma analyses.

The implementation of survey specific quality control measures included the collection of two (2) split samples at locations 9106-0009-013F and 9106-0009-016F for "split sample" analysis by the off-site laboratory.

6. SURVEY RESULTS The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) - Charleston, South Carolina. The laboratory analyzed the fifteen (15) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy. Ni-63 was analyzed by liquid scintillation analysis. All analyses were performed to the required MDC.

Cesium-137 was identified in eleven (11), Co-60 was identified in eleven (11),

and Ni-63 in none of the fifteen (15) samples. The results reported for the remaining sample analyses indicated that activity was present at levels approaching or below the established detection limits in the remaining samples collected and analyzed for non-parametric testing.

Several other radionuclides which were positively identified (i.e., a result greater than two (2) standard deviations uncertainty) could be de-selected or excluded using the 5% and 10% rule described in Section 5.4.7.2 of the LTP.

The off-site laboratory also processed four (4) samples for full HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy and liquid scintillation depending upon the radionuclide and the measurement method. All analyses were performed to the required MDC. A number of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty) in more than one (1)

Revision 0 12 Revision 0 12

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD sample. However, only H-3 and Cm-243/244 could not be de-selected based on the 5% and 10% rules.

None of the sample results exceeded the Operational DCGL or required further investigation. A summary of the sample results is provided in Table 5.

9106-0009-001 F 1.65E-01 1.18E-01 - 1.97E+00 6.46E-02 1.24E-01 9106-0009-002F 5.27E-01 9.04E-0 1 -1.20E+01 3.78E-01 3.91 E-0 I 9106-0009-003F O.OOE+00 1.52E-02 -7.67E+00 -8.73E-03 5.05E-02 9106-0009-004F -5.66E-03 1.99E-02 -2.23E+00 1.86E-03 6.11E-02 9106-0009-005F 1.91E-01 1.06E-01 -1.30E+01 4.47E-02 1.04E-01 9106-0009-007F 1.03E-01 6.71 E-02 -1.36E+01 1.55E-02 7.48E-02 9106-0009-008F 3.72E-02 4.83E-02 -1.29E+01 -6.52E-04 5.86E-02 9106-0009-009F 3.97E-01 4.58E-01 -7.24E+00 2.11 E-0 I 2.70E-01 9106-0009-01 OF 1.56E-01 1.53E-01 -4.44E+00 7.06E-02 1.30E-01 9106-0009-011 F 2.14E-03 -1.89E-02 -1.23E+01 -2.86E-02 4.64E-02 9106-0009-013F 2.85 E-02 0.OOE+00 -3.87E+00 -2.31 E-03 5.70E-02 9106-0009-014F 2.17E-01 6.26E-02 -1.04E+01 3.87E-02 1.89E-01 9106-0009-015F 1.86E-01 3.34E-01 -8.35E+00 1.31E-0I 1.90E-01 9106-0009-016F 1.70E-01 2.39E-01 -6.30E+00 9.92E-02 1.59E-01 9106-0009-017F 3.88E-0 1 5.37E-01 -5.48E+00 2.40E-01 2.38E-01 (1) The Operational DCGLs from Table 2 are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 549 for Ni-63; these are used in conjunction with the unity rule to achieve nineteen (19) mrem/yr TEDE.

(2) This column is the sum of the DCGL unity fraction from identified radionuclides of concern and HTD isotopes (H-3 and Cm-243/244) exceeding the 5%/10% rule for one or more FSS samples. For those samples not measured for HTD isotopes, an average calculated value of 5.9% of the DCGL was added to each sample. The average was calculated by adding the sample results for H-3 and Cm-243/244 of all the samples analyzed for those HTD isotopes, provided in Table 6 and dividing by the total number of samples analyzed for that radionuclide. This average value was applied to those samples that were not analyzed for HTD isotopes. If the sample was analyzed for HTDs, then the reported value was used instead of the average value.

NOTE: The off-site laboratory reported that all fifteen (15) of the samples analyzed for Ni-63, within this survey unit, had a negative value reported.

These negative values when used to determine the fraction of the Operational DCGL for the Radionuclide(s) of Concern had a maximum effect of lowering the fraction of the Operational DCGL present by less than 2.5% and the corresponding assigned dose for this survey unit by less than 0.5* mrem/yr TEDE.

Revision 0 13 Revision 0 13

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD

  • [-13.6 pCi/g (Maximum reported negative value for Ni-63) + 549 pCi/g (Operational DCGL for Ni-63) x 19 mrem/yr TEDE per DCGL = -0.471 mrem/yr TEDE z -0.5 mrem/yr TEDE]

The off-site laboratory also processed four (4) samples for HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC. Four (4) of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one sample. Each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules, with the exceptions of Cm-243/244 and H-3.

These results are presented in Table 6.

- T.able 6-H**d-to.-Detect Samp Results . . . ,.

~Samnple Number H. -3 Cmi243/244 .Fraction ofthe (2 PCiCu +c/Operational D('(; 1, 9106-0009-002F 4.12 0.013 0.0138 9106-0009-011F 3.69 1.39 0.0750 9106-0009-014F 46.9 0.00 0.1498 9106-0009-017F 0.58 -0.073 -0.0015 (1) The Operational DCGL from Table 2 is 313 pCi/g for H-3 and 22.0 pCi/g for Cm-243/244.

(2) This represents the unity fraction of the DCGL from nuclides that are were not considered nuclides of concern from the FSS.

Biased samples were not called for in the sample plan.

7. QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. Two (2) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 and as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey. " There was acceptable agreement between the field split results for both of the "split sample" pairs tested.

The sample analysis vendor, General Engineering Laboratories (GEL) -

Charleston, South Carolina, maintained quality control and quality assurance plans as part of normal operation. Refer to Attachment 2 for data and data quality analysis results.

8. INVESTIGATIONS AND RESULTS No investigations were required to be performed since none of the sample results exceeded the investigation levels.

Revision 0 14 Revision 0 14

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD

9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.
10. CHANGES FROM THE FINAL STATUS SURVEY PLAN The survey was designed to ten (10) mrem/yr TEDE which was conservative and necessary at the time of FSS planning. It is no longer required as the total dose from existing and future groundwater has been established. The dose for sediment used to demonstrate compliance with the LTP criteria is nineteen (19) mrem/yr TEDE as discussed in Section 2 of this Release Record.
11. DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment. " The sample design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs.

The evaluation of the Sign Test results indicates that the survey unit passes the unrestricted release criterion, thus, the null hypothesis is rejected.

Documenation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The sample standard deviation was slightly more than the value used for the survey design. This is represented by the shift in the retrospective power curve as shown in Attachment 2f. This would indicate a change to the original LBGR to maintain the number of samples at fifteen (15) to meet the Operational DCGL. However, the value of LBGR is less of a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL when used in conjunction with the unity rule. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the release criteria with adequate power as required by the DQOs.

Revision 0 15

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD The range of the data, about 3.58 standard deviations, was not unusually large.

The difference between the mean and median was 34% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 1.52.

All data, assessments, and graphical representations are provided in Attachment 2.

12. ANOMALIES The finding of two (2) HTD radionuclides in excess the screening criteria was the only anomaly associated with the FSS of this survey unit. Additionally, the testing of additional samples for HTDs has failed to yield additional positive results for either H-3 or Cm-243/244. For conservatism, the HTD results were factored into all statistical evaluations of the survey data for this survey unit accounting for any possible dose contributions. This action does not alter the conclusion that this survey unit meets the criteria for unconditional release.

No other anomalies were noted in the performance of this FSS.

13. CONCLUSION Survey Unit 9106-0009 has demonstrated compliance with the dose based, unrestricted release criterion. The sample data passed the Sign Test and the null hypothesis was rejected. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Reclassification and remediation of this survey unit was not required.

Graphical representation of data indicates some positive skewness that is probably due to localized differences in particulate deposition rates, hydraulic velocity and sedimentation rates. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit was properly designated as a Class 2 survey unit.

As stated in Section 6, all fifteen (15) sample results reported for Ni-63 were negative values. These negative values were used when determining the sum of the fractions (unity rule) and, therefore, lowered the reported fraction of the Operational DCGL. In the interests of conservatism, the maximum dose contribution from the negative impact of using these values will be added to the total dose for this survey unit. The maximum dose contribution for Ni-63 is less than 0.5 mrem/yr TEDE.

The dose contribution from sediment is 3.2 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

Revision 0 16 Revision 0 16

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD This survey unit is not affected by existing groundwater (reference CY memo ISC 06-024). It has been determined that the dose contribution from groundwater sources is zero (0) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component, is therefore zero (0) mrem/yr TEDE.

The average total dose from residual radioactivity in this survey unit, including that from sediment, will not exceed 3.2 mrem/yr Total Effective Dose Equivalent (TEDE).

14. ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Sample and Statistical Data Revision 0 17 Revision 0 17

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 1 Figures (5 pages)

n V; :

/ P 0 420 840 Cbadhow mmi NAD27CucoW~j Sh*bfl~w 1/P Connecdcut Yankee Atomic PowerCompany Site Map With Referece To Survey Unit9106-0008

Le wd Sample Location SInsoacesble saple Location NAD27Ccmweedo SA*Phwyw 13 0 0 42.5 55

Fed MWIZ=

14 0

Connecticut Yankee Atomic PowerCompany 9106-0009FinalStatus Survey Design

4..

Sample Location SInaccessible sample Location ANc Coamdbow m in NAtW27Wamw&U awhWn-M C-k!n-l37rm A~jW~iMzm$*

0.0285 0 0 42.5 85 Feet 0.217 Connecticut Yankee Atomic PowerCompany 9106-0009 FinalStatus Survey Cesium-137PostingPlot

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2 Sample and Statistical Data

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2a Sample Data (179 Pages)

General Narrative 1

CASE NARRATIVE For CONNECTICUT YANKEE RE: Soils PO# 002332 Work Order: 164542 SDG: MSR #06-0818 June 7, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address:

P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:

2040 Savage Road Charleston, South Carolina 29407 Telephone Number:

(843) 556-8171 Summary:

Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 164542001 9106-0009-016F 164542002 9106-0009-016FS 164542003 9106-0009-017F 164542004 9106-0009-013F 164542005 9106-0009-013FS 164542006 9106-0009-015F 164542007 9106-0009-001F 164542008 9106-0009-002F 164542009 9106-0009-003F 164542010 9106-0009-004F 164542011 9106-0009-005F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP,INC.

P.O. Box 30712

  • Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (843) 556-8171 - Fax843) 766-1178 ° www.gel.com

164542012 9106-0009-007F 164542013 9106-0009-008F 164542014 9106-0009-009F 164542015 9106-0009-OIOF 164542016 9106-0009-01 IF 164542017 9106-0009-014F Items of Note:

There are no items of note.

Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request:

Two soil samples were analyzed for FSSALL. Fifteen soil samples were analyzed for FSSGAM and Ni-63.

Internal Chain of Custody:

Custody was maintained for the sample(s).

Data Package:

The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP,INC.

RO. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)

Phone (843) 556-8171 - Fa 3 (843) 766-1178 ° www.gel.com

Chain of Custody and Supporting Documentation 4

Health Physics Procedure GPP-GGGR-R5] 04-003 -Attach ment B-CY-001 Major Health Physics Procedure

,/4*Lh2~

1W' s-

'A

,

~ *- - GPP-GGGR-R5 104-003-Attachment B-CY-00 1 Major Chain of Custody Form No. 2006-00380 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested LabUse. Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones z Priority: Z 30 D. [] 14 D. Li 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0009-016F 5/15/06 13:28 SE C BP x x Transferred from COC 2006-00352 C 9106-0009-016FS 5/15/06 13:28 SE C BP X X Transferred from COC 2006-00352

, 9106-0009-017F 5/15/06 14:03 SE C BP X X Transferred from COC 2006-00352 9106-0009-01 IF 5/15/06 08:05 SE C BP x Transferred from COC 2006-00351 O 9106-0009-013F 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 9106-0009-013FS 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 D17 9106-0009-014F 5/15/06 08:59 SE C BP X Transferred from COC 2006-00351 SA 9106-0009-015F 5/15/06 09:36 SE C BP x x Transferred from COC 2006-00351 NOTES: PO #: 002332 MSR #: 06-0S/1 SSWP# NA Z LTP QA Samples Shipped Via: Internal Container

[] Radwaste QA [] Non QA Z Fed Ex Temp.: __ Deg. C L] ups ni Hand Custody Sealed?

YE NO

1) Relinquisled By Date/Time 2) Rec v d y Date/Time Custody Seal Intact?

E] Other

3) Relinquished By Date/Time 4) Reteivelt By Date/Time YE Nn Bill of Lading #

- ?-T 2gu

Health Physics Procedure 1ýtj W__1 GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00381 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories <

2040 Savage Road. Charleston SC. 29407 C <;

843 556 8171. Attn. Cheryl Jones & ý5 z Priority: E 30 D. [:114 D. [:E7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0009-00 1F 5/11/06 13:22 SE C BP x x Transferred from COC 2006-00347 6 9106-0009-002F 5/11/06 13:46 SE C BP X X Transferred from COC 2006-00347 DI 9106-0009-003F 5/11/06 14:06 SE C BP X X Transferred from COC 2006-00347 01t 9106-0009-004F 5/11/06 14:30 SE C BP X X Transferred from COC 2006-00347 041I 9106-0009-005F 5/11/06 14:55 SE C BP X X Transferred from COC 2006-00347 0

lj 9106-0009-007F 5/12/06 07:44 SE C BP X X Transferred from COC 2006-00348

! 9106-0009-008F 5/12/06 08:16 SE C BP X X Transferred from COC 2006-00348 (4 9106-0009-009F 5/12/06 08:35 SE C BP X X Transferred from COC 2006-00348 9106-0009-01OF 5/12/06 09:07 SE C BP X X Transferred from COC 2006-00348 NOTES: PO #: 002332 MSR #: 06- SSWP#NA Z LTPQA ED Radwaste QA El Non QA Samples Shipped Via: Internal Container N Fed Ex Temp.: _- Deg. C QI uPs MI Hand Custody Sealed?

YE] NE

1) Relinquished By Date/Time 2) Rec *ey Date/Time Custody Seal Intact?
3) Reiqis c By1- Dat/:ime Ree*e 401*yo r6 LI Other
3) Relinquished By Date/Time 4) Received y DatefTime YE0 NE1 Bill of Lading #

3qtt lyf5. Z,5T

IjpqL614Z Z c40o C~ IV146Sly,51 Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-0OOI Figure 1. Samj pie Check*in List Date/Time Received: - - 0 eq o SDG#: MS ()4 O( 00 1 Work Order Number:

Shipping C ohtainer ID:_._,, _- _t, _- __, __ Chain of Custody A. il I. Custody Seals. ori shipping container intact? Yes I No [ I

2. Custody Seals dated and signed? Yes[ ].No N
3. Chain-of-Custo¶Iy record present? Yes [* No [ ]
4. Cooler temperature 6O,
5. Vermiculite/packing materials is: Wet [ Dry 6.: -Numberof samples in shipping container:
7. Sample holding times exceeded? Yes [X4 No [1
10. Were any anomalies identified in sample receipt? Yes [ No I 1.. ,Descriptionof anomalies,(include sample numbers):

Sample Custodian/Laboratory: , Datew _ G -1 '

Telephoned to: -On By It, 7

RADIOLOGICAL ANALYSIS 8

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 164542 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 542293 Prep Batch Number: 537131 Dry Soil Prep GL-RAD-A-021 Batch Number: 537124 Sample ID Client ID 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201121832 Method Blank (MB) 1201121833 165557001(1000-0000-119-C-i C-01) Sample Duplicate (DUP) 1201121834 165557001(1000-0000-119-C-iC-01) Matrix Spike (MS) 1201121835 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

9

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 165557001 (1000-0000-119-C-IC-01).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments The Cm-233/234 blank result is greater than the MDA but less than the detection limit.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 10

Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 542294 Prep Batch Number: 537131 Dry Soil Prep GL-RAD-A-021 Batch Number: 537124 Sample ID Client ID 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201121836 Method Blank (MB) 1201121837 165557001(1000-0000-119-C-i C-01) Sample Duplicate (DUP) 1201121838 165557001(1000-0000-119-C-i C-01) Matrix Spike (MS) 1201121839 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 165557001 (1000-0000-119-C-IC-01).

QC Information All of the QC samples met the required acceptance limits.

11

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-1 1-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 542295 Prep Batch Number: 537131 Dry Soil Prep GL-RAD-A-021 Batch Number: 537124 12

Sample ID Client ID 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201121840 Method Blank (MB) 1201121841 165557001(1000-0000-119-C-1C-01) Sample Duplicate (DUP) 1201121842 165557001(1000-0000-119-C-IC-01) Matrix Spike (MS) 1201121843 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 165557001 (1000-0000-119-C-1C-01).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 13

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS Analytical Method: EML HASL 300,4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 537866 Prep Batch Number: 537124 Sample ID Client ID 164542001 9106-0009-016F 164542002 9106-0009-016FS 164542003 9106-0009-017F 164542004 9106-0009-013F 164542005 9106-0009-013FS 164542006 9106-0009-015F 164542007 9106-0009-OOIF 164542008 9106-0009-002F 164542009 9106-0009-003F 164542010 9106-0009-004F 164542011 9106-0009-005F 164542012 9106-0009-007F 164542013 9106-0009-008F 164542014 9106-0009-009F 164542015 9106-0009-01 OF 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201111185 Method Blank (MB) 1201111186 164542001(9106-0009-016F) Sample Duplicate (DUP) 1201111187 Laboratory Control Sample (LCS) 14

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 11.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 164542001 (9106-0009-016F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 164542003 (9106-0009-017F) and 164542008 (9106-0009-002F) were recounted due to high MDAs.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The sample and the duplicate, 1201111186 (9106-0009-016F) and 164542001 (9106-0009-016F), did not meet the relative percent difference requirement for Co-60. However, they do meet the relative error ratio requirement with a value of 1.7.

15

Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to high peak-width. Bismuth-212 164542013 Cesium- 134 164542008 Cesium-137 164542009 UI Data rejected due to interference. Europium-155 164542009 UI Data rejected due to low abundance. Bismuth-214 164542008 164542015 Cesium-134 164542003 164542007 Cobalt-60 164542004 UI data rejected due to high peak width Manganese-54 164542010 Potassium-40 1201111185 UI data rejected due to low abundance Cesium-134 164542002 164542004 164542005 164542016 1201111186 Niobium-94 164542005 Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 541208 Prep Batch Number: 537131 Dry Soil Prep GL-RAD-A-021 Batch Number: 537124 16

Sample ID Client ID 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201119317 Method Blank (MB) 1201119318 164551004(9106-0002-019F) Sample Duplicate (DUP) 1201119319 164551004(9106-0002-019F) Matrix Spike (MS) 1201119320 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 164551004 (9106-0002-019F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

17

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 540445 Sample ID Client ID 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201117552 Method Blank (MB) 1201117553 165011005(1000-0000-125-C-i C-01) Sample Duplicate (DUP) 1201117554 165011005(1000-0000-125-C-i C-01) Matrix Spike (MS) 1201117555 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

18

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 165011005 (1000-0000-125-C-1C-01).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-i, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 538969 Prep Batch Number: 537131 Dry Soil Prep GL-RAD-A-021 Batch Number: 537124 19

Sample ID Client ID 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201113887 Method Blank (MB) 1201113888 163741008(9106-0008-007F) Sample Duplicate (DUP) 1201113889 163741008(9106-0008-007F) Matrix Spike (MS) 1201113890 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 163741008 (9106-0008-007F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

20

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 541424 Prep Batch Number: 537131 Dry Soil Prep GL-RAD-A-021 Batch Number: 537124 21

Sample ID Client ID 164542001 9106-0009-016F 164542002 9106-0009-016FS 164542003 9106-0009-017F 164542004 9106-0009-013F 164542005 9106-0009-013FS 164542006 9106-0009-015F 164542007 9106-0009-001F 164542008 9106-0009-002F 164542009 9106-0009-003F 164542010 9106-0009-004F 164542011 9106-0009-005F 164542012 9106-0009-007F 164542013 9106-0009-008F 164542014 9106-0009-009F 164542015 9106-0009-01OF 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201119883 Method Blank (MB) 1201119884 164542011(9106-0009-005F) Sample Duplicate (DUP) 1201119885 164542011(9106-0009-005F) Matrix Spike (MS) 1201119886 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 164542011 (9106-0009-005F).

QC Information All of the QC samples met the required acceptance limits.

22

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 542573 Sample ID Client ID 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201122404 Method Blank (MB) 1201122405 165702005(9106-0011-009F) Sample Duplicate (DUP) 1201122406 165702005(9106-0011-009F) Matrix Spike (MS) 1201122407 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.

23

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 165702005 (9106-0011-009F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 24

Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 545141 Sample ID Client ID 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201128388 Method Blank (MB) 1201128389 165011012(1000-0000-120-C-I C-02) Sample Duplicate (DUP) 1201128390 165011012(1000-0000-120-C-i C-02) Matrix Spike (MS) 1201128391 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 165011012 (1000-0000-120-C-1C-02).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

25

Sample Re-prep/Re-analysis Samples were reprepped due to low/high recovery.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date: . , 7/1//

26

SAMPLE DATA

SUMMARY

27

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-0818 GEL Work Order: 164542 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 28

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-016F Project: YANK01204 Sample ID: 164542001 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 32.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.865 +/-0.203 0.0598 +/-0.203 0.129 pCi/g MJH1 06/26/06 1925 537866 1 Americium-2 4 1 U 0.0409 +/-0.0866 0.0774 +/-0.0866 0.159 pCi/g Bismuth-212 0.562 +/-0.221 0.149 +/-0.221 0.315 pCi/g Bismuth-214 0.556 +/-0.116 0.0341 +/-0.116 0.072 pCi/g Cesium-134 LJ 0.0263 +/-0.0382 0.0263 +/-0.0382 0.0553 pCi/g Cesium- 137 0.170 +/-0.0433 0.0185 +/-0.0433 0.0392 pCi/g Cobalt-60 0.239 +/-0.0465 0.0197 +/-0.0465 0.0428 pCi/g Europium-152 tJ 0.0167 +/-0.0586 0.0506 +/-0.0586 0.105 pCi/g Europium-154 LJ -0.0172 +/-0.0755 0.0623 +/-0.0755 0.134 pCi/g Europium-155 LJ 0.0597 +/-0.0887 0.0526 +/-0.0887 0.108 pCi/g Lead-212 0.938 +/-0.0991 0.0287 +/-0.0991 0.0594 pCi/g Lead-214 0.688 +/-0.114 0.0321 +/-0.114 0.0672 pCi/g Manganese-54 t 0.0262 +/-0.025 0.0225 +/-0.025 0.0474 pCi/g Niobium-94 L -0.00291 +/-0.0206 0.0173 +/-0.0206 0.0366 pCi/g Potassium-40 14.4 +/-1.33 0.169 +/- 1.33 0.372 pCi/g Radium-226 0.556 +/-0.116 0.0341 +/-0.116 0.072 pCi/g Silver-108m L1 -0.00368 +/-0.0205 0.0169 +/-0.0205 0.0355 pCi/g Thallium-208 0.327 +/-0.0551 0.0182 +1-0.0551 0.0384 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 L -6.3 +/-8.63 7.41 +/-8.63 15.2 pCi/g SLNl 07/06/06 0552 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 29

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-016F Project: YANKO 1204 Sample ID: 164542001 Client ID: YANKOOl Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 93 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

30

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-016FS Project: YANKO 1204 Sample ID: 164542002 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 26.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.878 +/-0.189 0.0564 +/-0.189 0.122 pCi/g MJH1 06/26/06 1925 537866 1 Americium-241 U -0.0346 +/-0.106 0.081 +/-0.106 0.168 pCi/g Bismuth-212 0.587 +/-0.254 0.137 +/-0.254 0.292 pCi/g Bismuth-214 0.544 +/-0.0981 0.0327 +/-0.0981 0.0692 pCi/g Cesium-134 UI 0.00 +/-0.0439 0.0244 +/-0.0439 0.0514 pCi/g Cesium-137 0.231 +/-0.0415 0.0159 +/-0.0415 0.0339 pCi/g Cobalt-60 0.277 +/-0.061 0.0187 +/-0.061 0.0409 pCi/g Europium-152 U 0.0343 +/-0.0509 0.0443 +/-0.0509 0.0928 pCi/g Europium-154 U -0.031 +/-0.0614 0.0487 +/-0.0614 0.107 pCi/g Europium-155 U 0.0255 +/-0.0856 0.0484 +/-0.0856 0.100 pCi/g Lead-212 0.856 +/-0.0896 0.0244 +/-0.0896 0.0508 pCi/g Lead-214 0.647 +1-0.105 0.0294 +/-0.105 0.0619 pCi/g Manganese-54 U 0.0155 +/-0.0227 0.0199 +/-0.0227 0.0423 pCi/g Niobium-94 U -0.00637 +/-0.0187 0.0154 +/-0.0187 0.0327 pCi/g Potassium-40 13.0 +/-1.25 0.163 +/-1.25 0.361 pCi/g Radium-226 0.544 +/-0.0981 0.0327 +/-0.0981 0.0692 pCi/g Silver-108m U 0.0129 +/-0.0157 0.0161 +/-0.0157 0.0337 pCi/g Thallium-208 0.285 +/-0.0473 0.0177 +/-0.0473 0.0374 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -11.8 +/-9.16 8.00 +/-9.17 16.4 pCi/g SLNI 07/06/06 0614 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 88 (25/-,125%)

31

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-016FS Proiect: YANKO 1204 Sample ID: 164542002 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

32

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate

..........

of Analvwiv

"-r....... T *='-r Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Proiect: YANKO 1204 Sample ID: 164542003 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 28.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.965 +/-0.265 0.082 +/-0.265 0.176 pCi/g MJH1 07/06/06 1801 537866 1 Americium-241 U 0.0107 +/-0.0295 0.0256 +/-0.0295 0.0529 pCi/g Bismuth-212 0.823 +/-0.358 0.173 +/-0.358 0.370 pCi/g Bismuth-214 0.590 +/-0.108 0.0387 +/-0.108 0.0823 pCi/g Cesium-134 U! 0.00 +/-0.0622 0.0311 +/-0.0622 0.0659 pCi/g Cesium-137 0.388 +/-0.0535 0.0225 +/-0.0535 0.048 pCi/g Cobalt-60 0.537 +/-0.0744 0.0246 +/-0.0744 0.0541 pCi/g Europium-152 U -0.0211 +/-0.062 0.0502 +/-0.062 0.106 pCi/g Europium-154 U -0.00189 +/-0.0847 0.0701 +/-0.0847 0.153 pCi/g Europium-155 U 0.0848 +/-0.0505 0.0451 +1-0.0505 0.0933 pCi/g Lead-212 0.899 +/-0.0714 0.0289 +/-0.0714 0.0602 pCi/g Lead-214 0.693 +/-0.112 0.0345 +/-0.112 0.0728 pCi/g Manganese-54 U 0.00193 +/-0.0296 0.0244 +/-0.0296 0.0522 pCi/g Niobium-94 U -0.00651 +/-0.0298 0.0212 +/-0.0298 0.0451 pCi/g Potassium-40 14.0 +/-1.07 0.158 +/-1.07 0.365 pCi/g Radium-226 0.590 +/-0.108 0.0387 +/-0.108 0.0823 pCi/g Silver-108m U 0.0213 +/-0.0214 0.0198 +/-0.0214 0.0416 pCi/g Thallium-208 0.289 +/-0.0556 0.0197 +/-0.0556 0.0421 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -5.48 +/-9.76 8.34 +/-9.76 17.1 pCi/g SLNl 07/06/06 0635 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 90 (25%-125%)

33

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Project: YANK01204 Sample ID: 164542003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10,'2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-013F Project: YANKO 1204 Sample ID: 164542004 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 24.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.878 +/-0.180 0.0626 +/-0.180 0.135 pCi/g MJH1 06/26/06 1925 537866 1 Americium-241 U -0.047 +/-0.0919 0.0775 +/-0.0919 0.160 pCi/g Bismuth-212 0.870 +/-0.329 0.135 +/-0.329 0.288 pCi/g Bismuth-214 0.579 +/-0.0876 0.0328 +/-0.0876 0.0695 pCi/g Cesium-134 UI 0.00 +/-0.0372 0.0246 +/-0.0372 0.0519 pCi/g Cesium-137 U 0.0285 +/-0.0289 0.0185 +/-0.0289 0.0392 pCi/g Cobalt-60 UI 0.00 +/-0.0348 0.0197 +/-0.0348 0.0429 pCi/g Europium-152 U 0.0122 +/-0.0578 0.0497 +/-0.0578 0.104 pCi/g Europium-154 U - -0.00728 +/-0.0629 0.0533 +/-0.0629 0.116 pCi/g Europium-155 U 0.0493 +/-0.0549 0.0521 +/-0.0549 0.107 pCi/g Lead-2 12 0.976 +/-0.0702 0.0313 +/-0.0702 0.0645 pCi/g Lead-214 0.708 +/-0.0991 0.0337 +/-0.0991 0.0705 pCi/g Manganese-54 U -0.0103 +/-0.0211 0.0171 +/-0.0211 0.0367 pCi/g Niobium-94 U 0.0208 +/-0.0204 0.0187 +/-0.0204 0.0394 pCi/g Potassium-40 14.9 +/-0.995 0.211 +/-0.995 0.457 pCi/g Radium-226 0.579 +/-0.0876 0.0328 +/-0.0876 0.0695 pCi/g Silver-108m U - 0.00488 +/-0.0196 0.0161 +/-0.0196 0.0338 pCi/g Thallium-208 0.318 +/-0.0428 0.0166 +/-0.0428 0.0354 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -3.87 +/-9.05 7.70 +/-9.05 15.8 pCi/g SLNI 07/06/06 0657 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 DOE RESL Ni-l, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 90 (25%-125%)

35

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certifieate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-013F Proiect: YANKO 1204 Sample ID: 164542004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

36

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-013FS Proiect: YANKO 1204 Sample ID: 164542005 Client ID: YANKOO 1 Matrix: SE Vol. Recv.:

Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 25.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 1.08 +/-0.247 0.0754 +/-0.247 0.164 pCi/g MJHI 06/26/06 1926 537866 1 Americium-241 U -0.0339 +/-0.120 0.0907 +/-0.120 0.188 pCi/g Bismuth-212 0.626 +/-0.363 0.200 +/-0.363 0.426 pCi/g Bismuth-214 0.787 +/-0.144 0.0454 +/-0.144 0.0963 pCi/g Cesium-134 UI 0.00 +/-0.0439 0.0285 +/-0.0439 0.0608 pCi/g Cesium- 137 U 0.0462 +1-0.0552 0.0241 +/-0.0552 0.0514 pCi/g Cobalt-60 U -0.0278 +/-0.0303 0.0217 +/-0.0303 0.0482 pCi/g Europium-152 U -0.0132 +/-0.0736 0.0615 +/-0.0736 0.130 pCi/g Europium-154 U 0.0371 +/-0.0932 0.0794 +/-0.0932 0.172 pCi/g Europium-155 U 0.145 +/-0.113 0.0744 +/-0.113 0.154 pCi/g Lead-212 1.13 +/-0.128 0.0357 +/-0.128 0.0747 pCi/g Lead-214 0.940 +/-0.149 0.045 +/-0.149 0.0947 pCi/g Manganese-54 U 0.00369 +/-0.0305 0.026 +/-0.0305 0.0556 pCi/g Niobium-94 UI 0.00 +/-0.0696 0.019 +/-0.0696 0.0409 pCi/g Potassium-40 18.6 +/-1.66 0.206 +/-1.66 0.459 pCi/g Radium-226 0.787 +/-0.144 0.0454 +/-0.144 0.0963 pCi/g Silver-108m U 0.0214 +/-0.0237 0.021 +/-0.0237 0.0445 pCi/g Thallium-208 0.370 +/-0.0703 0.0216 +/-0.0703 0.0463 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -9.09 +/-8.91 7.72 +/-8.91 15.8 pCi/g SLNI 07/06/06 0754 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description I EML FIASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 89 (25%-125%)

37

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 9106-0009-013FS Proiect: YANKO 1204 Sample ID: 164542005 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

38

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-015F Project: YANKO 1204 Sample ID: 164542006 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 29.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.750 +/-0.165 0.069 +/-0.165 0.149 pCi/g MJHI 06/26/06 1926 537866 1 Americium-241 U 0.0322 +/-0.123 0.0837 +/-0.123 0.173 pCi/g Bismuth-212 0.554 +/-0.339 0.154 +/-0.339 0.328 pCi/g Bismuth-214 0.469 +/-0.0923 0.0348 +/-0.0923 0.0741 pCi/g Cesium-134 U 0.0282 +/-0.0277 0.0257 +/-0.0277 0.0545 pCi/g Cesium-137 0.186 +/-0.0599 0.0185 +/-0.0599 0.0397 pCi/g Cobalt-60 0.334 +/-0.0531 0.0185 +/-0.0531 0.0412 pCi/g Europium-152 U -0.0216 +/-0.0531 0.0465 +/-0.0531 0.098 pCi/g Europium-154 U -0.0217 +/-0.0697 0.0571 +/-0.0697 0.125 pCi/g Europium-155 U 0.0396 +/-0.0659 0.0536 +/-0.0659 0.111 pCi/g Lead-212 0.872 +/-0.0677 0.0275 +/-0.0677 0.0573 pCi/g Lead-214 0.602 +/-0.103 0.034 +/-0.103 0.0716 pCi/g Manganese-54 U 0.0235 +/-0.0254 0.0229 +/-0.0254 0.0488 pCi/g Niobium-94 U -0.00451 +/-0.0206 0.0172 +/-0.0206 0.0367 pCi/g Potassium-40 12.8 +/-0.916 0.172 +/-0.916 0.385 pCi/g Radium-226 0.469 +/-0.0923 0.0348 +/-0.0923 0.0741 pCi/g Silver-108m U -0.0106 +/-0.0194 0.0165 +/-0.0194 0.035 pCi/g Thallium-208 0.282 +/-0.0509 0.0187 +/-0.0509 0.0398 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -8.35 +/-12.6 10.8 +/-12.6 22.2 pCi/g SLN1 07/06/06 0816 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description I EML HIASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 72 (25%-125%)

39

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-015F Project: YANK0 1204 Sample ID: 164542006 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria
  • Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

40

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-00IF Project: YANK01204 Sample ID: 164542007 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 1 I-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 38.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS Actinium-228 0.947 +/-0.162 0.0626 +/-0.162 0.136 pCi/g MJH1 06/26/06 2131 537866 1 Americium-241 U -0.0496 +/-0.0955 0.0742 +/-0.0955 0.153 pCi/g Bismuth-212 0.584 +/-0.331 0.146 +/-0.331 0.313 pCi/g Bismuth-214 0.642 +/-0.110 0.0346 +/-0.110 0.0734 pCi/g Cesium-134 UI 0.00 +/-0.0515 0.0279 +/-0.0515 0.0589 pCi/g Cesium-137 0.165 +/-0.0351 0.0181 +/-0.0351 0.0387 pCi/g Cobalt-60 0.118 +/-0.0475 0.0219 +/-0.0475 0.048 pCi/g Europium- 152 U -0.0188 +/-0.0592 0.0474 +/-0.0592 0.0995 pCi/g Europium- 154 U -0.013 +/-0.0795 0.0666 +/-0.0795 0.144 pCi/g Europium-155 U 0.052 +/-0.0744 0.0472 +/-0.0744 0.0979 pCi/g Lead-212 1.04 +/-0.0711 0.0275 +/-0.0711 0.0571 pCi/g Lead-214 0.766 +/-0.0898 0.0323 +/-0.0898 0.0681 pCi/g Manganese-54 U 0.0113 +/-0.0265 0.0228 +/-0.0265 0.0485 pCi/g Niobium-94 U 0.0108 +/-0.0212 0.0185 +/-0.0212 0.0393 pCi/g Potassium-40 15.6 +/-1.05 0.164 +/-1.05 0.369 pCi/g Radium-226 0.642 +/-0.110 0.0346 +/-0.110 0.0734 pCi/g Silver-108m U 0.0094 +/-0.0195 0.0174 +/-0.0195 0.0366 pCi/g Thallium-208 0.375 +/-0.056 0.0164 +/-0.056 0.0353 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -1.97 +/-9.30 7.86 +/-9.30 16.1 pCi/g SLNI 07/06/06 0837 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 97 (25%-125%)

41

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-001F Project: YANK01204 Sample ID: 164542007 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Proiect: YANKO 1204 Sample ID: 164542008 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 1I-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 36.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS Actinium-228 0.933 +/-0.325 0.132 +/-0.325 0.282 pCi/g MJHI 07/06/06 1801 537866 1 Americium-241 U 0.0584 +1-0.0515 0.0426 +/-0.0515 0.0878 pCi/g Bismuth-212 0.963 +/-0.481 0.261 +/-0.481 0.558 pCi/g Bismuth-214 Ut 0.00 +/-0.157 0.122 +/-0.157 0.252 pCi/g Cesium-134 UI 0.00 +/-0.090 0.0391 +/-0.090 0.0836 pCi/g Cesium- 137 0.527 +/-0.0887 0.0329 +/-0.0887 0.070 pCi/g Cobalt-60 0.904 +/-0.124 0.0357 +/-0.124 0.0783 pCi/g Europium-152 U -0.00341 +/-0.0841 0.0727 +/-0.0841 0.153 pCi/g Europium-154 U 0.0363 +/-0.117 0.101 +/-0.117 0.220 pCi/g Europium-155 U 0.00509 +/-0.0767 0.0659 +/-0.0767 0.136 pCi/g Lead-212 1.04 +/-0.102 0.0392 +/-0.102 0.0819 pCi/g Lead-214 0.872 +/-0.160 0.0543 +/-0.160 0.114 pCi/g Manganese-54 U -0.00711 +/-0.0458 0.0369 +/-0.0458 0.0789 pCi/g Niobium-94 U 0.0283 +/-0.0342 0.0302 +/-0.0342 0.0643 pCi/g Potassium-40 15.1 +/-1.36 0.285 +/-1.36 0.638 pCi/g Radium-226 0.864 +/-0.157 0.0544 +/-0.157 0.116 pCi/g Silver-108m U 0.0067 +/-0.0301 0.0261 +/-0.0301 0.0551 pCi/g Thallium-208 0.313 +/-0.0898 0.0353 +/-0.0898 0.0748 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 12 +/-9.86 8.60 +/-9.87 17.6 pCi/g SLN1 07/06/06 0859 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 86 (25%-I125%)

43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Proiect: YANK01204 Sample ID: 164542008 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

U! Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analyvis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-003F Proiect: YANKO 1204 Sample ID: 164542009 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: I I-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 46.6%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.831 +/-0.208 0.0672 +/-0.208 0.146 pCi/g MJH1 06/26/062131 537866 1 Americium-241 U -0.0139 +/-0.109 0.0816 +/-0.109 0.168 pCi/g Bismuth-212 0.915 +/-0.395 0.154 +/-0.395 0.330 pCi/g Bismuth-214 0.479 +/-0.140 0.0406 +/-0.140 0.0859 pCi/g Cesium-134 U 0.051 +/-0.0395 0.0275 +/-0.0395 0.0583 pCi/g Cesium-137 UI 0.00 +/-0.0699 0.0204 +/-0.0699 0.0434 pCi/g Cobalt-60 U 0.0152 +/-0.0258 0.0228 +/-0.0258 0.0499 pCi/g Europium-152 U --0.00268 +/-0.0629 0.052 +/-0.0629 0.109 pCi/g Europium-154 U -0.0552 +/-0.0912 0.0716 +/-0.0912 0.155 pCi/g Europium-155 UI 0.00 +/-0.154 0.0554 +/-0.154 0.115 pCi/g Lead-212 0.989 +/-0.112 0.0314 +/-0.112 0.0653 pCi/g Lead-214 0.777 +/-0.126 0.0373 +/-0.126 0.0784 pCi/g Manganese-54 U 0.0118 +/-0.0292 0.0248 +/-0.0292 0.0528 pCi/g Niobium-94 U -0.0184 +/-0.0231 0.0181 +/-0.0231 0.0385 pCi/g Potassium-40 13.5 +/-1.42 0.214 +/-1.42 0.472 pCi/g Radium-226 0.479 +/-0.140 0.0406 +/-0.140 0.0859 pCi/g Silver-108m U -0.0159 +/-0.0225 0.0174 +/-0.0225 0.0368 pCi/g Thallium-208 0.320 +/-0.0617 0.0201 +/-0.0617 0.0428 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -7.67 +/-9.42 8.11 +/-9.42 16.6 pCi/g SLNI 07/06/06 0920 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 84 (25%-125%)

45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-003F Proiect: YANKO 1204 Sample ID: 164542009 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analwviq Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-004F Proiect: YANKO 1204 Sample ID: 164542010 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 11-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 39.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.627 +/-0.164 0.0613 +/-0.164 0.132 pCi/g MJHI 06/26/06 2132 537866 1 Americium-241 U -0.0965 +/-0.143 0.0901 +/-0.143 0.187 pCi/g Bismuth-212 0.708 +/-0.249 0.136 +/-0.249 0.290 pCi/g Bismuth-214 0.564 +/-0.084 0.027 +/-0.084 0.0576 pCi/g Cesium-134 U 0.00218 +/-0.0433 0.0201 +/-0.0433 0.0428 pCi/g Cesium-137 U -0.00566 +/-0.0197 0.0162 +/-0.0197 0.0346 pCi/g Cobalt-60 U 0.0199 +/-0.026 0.0211 +/-0.026 0.0457 pCi/g Europium-152 U 0.0303 +/-0.0491 0.0422 +/-0.0491 0.0887 pCi/g Europium-154 U 0.0292 +/-0.0621 0.0547 +/-0.0621 0.119 pCi/g Europium-155 U 0.0584 +/-0.0685 0.0477 +/-0.0685 0.0988 pCi/g Lead-212 0.641 +/-0.0581 0.0256 +/-0.0581 0.0533 pCi/g Lead-214 0.603 +/-0.0845 0.031 +/-0.0845 0.065 pCi/g Manganese-54 UI 0.00 +/-0.0295 0.0141 +/-0.0295 0.0308 pCi/g Niobium-94 U-0.000263 +/-0.018 0.0151 +/-0.018 0.0321 pCi/g Potassium-40 12.7 +/-0.870 0.127 +/-0.870 0.290 pCi/g Radium-226 0.564 +/-0.084 0.027 +/-0.084 0.0576 pCi/g Silver-108m U-0.000165 +/-0.0166 0.0145 +/-0.0166 0.0306 pCi/g Thallium-208 0.204 +/-0.044 0.0167 +/-0.044 0.0355 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -2.23 +/-9.09 7.69 +/-9.10 15.8 pCi/g SLNI 07/06/06 0942 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-l, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 87 (25/,- 25%)

47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-004F Project: YANK01204 Sample ID: 164542010 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-005F Project: YANK01204 Sample ID: 164542011 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 11-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 37.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.810 +/-0.177 0.0514 +/-0.177 0.110 pCi/g MJH1 06/26/06 2352 537866 1 Americium-241 U -0.0635 +/-0.0844 0.0694 +/-0.0844 0.143 pCi/g Bismuth-212 0.572 +/-0.216 0.118 +/-0.216 0.251 pCi/g Bismuth-214 0.563 +/-0.0915 0.0261 +/-0.0915 0.0552 pCi/g Cesium-134 U 0.00 +/-0.0319 0.0209 +/-0.0319 0.0438 pCi/g Cesium- 137 0.191 +/-0.0424 0.0143 +/-0.0424 0.0303 pCi/g Cobalt-60 0.106 +/-0.0417 0.0169 +/-0.0417 0.0366 pCi/g Europium-152 U 0.0201 +/-0.0463 0.0396 +/-0.0463 0.0825 pCi/g Europium-154 U 0.0417 +/-0.0763 0.0437 +/-0.0763 0.0949 pCi/g Europium-155 U 0.0655 +/-0.0642 0.0423 +/-0.0642 0.0871 pCi/g Lead-212 0.847 +/-0.0862 0.0217 +/-0.0862 0.0449 pCi/g Lead-214 0.593 +/-0.090 0.026 +/-0.090 0.0544 pCi/g Manganese-54 U 0.0171 +/-0.0157 0.0135 +/-0.0157 0.0289 pCi/g Niobium-94 U - 0.00235 +/-0.0154 0.0129 +/-0.0154 0.0273 pCi/g Potassium-40 12.5 +/-1.17 0.107 +/-1.17 0.242 pCi/g Radium-226 0.563 +/-0.0915 0.0261 +/-0.0915 0.0552 pCi/g Silver-108m U 0.00649 +/-0.0144 0.013 +/-0.0144 0.0273 pCi/g Thallium-208 0.259 +/-0.0444 0.0143 +/-0.0444 0.0302 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -13 +/-9.02 7.92 +/-9.03 16.3 pCi/g SLN1 07/06/06 1003 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-005F Proiect: YANKO 1204 Sample ID: 164542011 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 93 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Ci-rtifirntP nf A n2lv-ii Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-007F Proiect: YANK01204 Sample ID: 164542012 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 12-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 26.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.843 +/-0.157 0.060 +/-0.157 0.130 pCi/g MJH1 06/26/06 2132 537866 1 Americium-241 U 0.0298 +/-0.0903 0.0777 +/-0.0903 0.160 pCi/g Bismuth-212 0.329 +/-0.305 0.137 +/-0.305 0.294 pCi/g Bismuth-214 0.499 +/-0.102 0.0344 +/-0.102 0.0728 pCi/g Cesium-134 U 0.00886 +/-0.0266 0.0231 +/-0.0266 0.049 pCi/g Cesium- 137 0.103 +/-0.048 0.0176 +/-0.048 0.0376 pCi/g Cobalt-60 0.0671 +/-0.0364 0.0187 +/-0.0364 0.0413 pCi/g Europium-152 U 0.0806 +/-0.0694 0.0476 +/-0.0694 0.0998 pCi/g Europium- 154 U 0.020 +/-0.0702 0.0617 +/-0.0702 0.134 pCi/g Europium-155 U 0.0584 +/-0.0521 0.0494 +/-0.0521 0.102 pCi/g Lead-212 0.752 +/-0.0686 0.0291 +/-0.0686 0.0602 pCi/g Lead-214 0.660 +/-0.0977 0.0328 +/-0.0977 0.0689 pCi/g Manganese-54 U 0.0129 +/-0.0245 0.0215 +/-0.0245 0.0457 pCi/g Niobium-94 U --0.00677 +/-0.0196 0.0163 +/-0.0196 0.0348 pCi/g Potassium-40 12.7 +/-0.968 0.139 +/-0.968 0.316 pCi/g Radium-226 0.499 +/-0.102 0.0344 +/-0.102 0.0728 pCi/g Silver-108m U 0.00329 +/-0.0197 0.0165 +/-0.0197 0.0347 pCi/g Thallium-208 0.272 +/-0.0473 0.0175 +/-0.0473 0.0372 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -13.6 +/-9.31 8.18 +/-9.32 16.8 pCi/g SLNI 07/06/06 1025 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-l, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 87 (25 %r-125%)

51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-007F Project: YANKO 1204 Sample ID: 164542012 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-008F Proiect: YANKO 1204 Sample ID: 164542013 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 12-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 21%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.400 +/-0.170 0.0803 +/-0.170 0.176 pCi/g MJHI 06/26/06 2132 537866 1 Americium-241 U 0.0209 +/-0.089 0.085 +/-0.089 0.178 pCi/g Bismuth-212 UI 0.00 +/-0.369 0.166 +/-0.369 0.361 pCi/g Bismuth-214 0.384 +/-0.0728 0.0346 +/-0.0728 0.0753 pCi/g Cesium-134 U 0.0266 +/-0.0264 0.0252 +/-0.0264 0.0548 pCi/g Cesium-137 U 0.0372 +/-0.0247 0.0193 +/-0.0247 0.0422 pCi/g Cobalt-60 U 0.0483 +/-0.0265 0.0275 +/-0.0265 0.0607 pCi/g Europium-152 U -0.0559 +/-0.0623 0.0511 +/-0.0623 0.109 pCi/g Europium-154 U 0.014 +/-0.0855 0.0647 +/-0.0855 0.145 pCi/g Europium-155 U 0.00754 +/-0.062 0.0566 +/-0.062 0.118 pCi/g Lead-212 0.624 +/-0.0725 0.031 +/-0.0725 0.0652 pCi/g Lead-214 0.362 +/-0.0776 0.0329 +/-0.0776 0.0708 pCi/g Manganese-54 U 0.00129 +/-0.0255 0.0219 +/-0.0255 0.0479 pCi/g Niobium-94 U -0.0174 +/-0.0227 0.0182 +/-0.0227 0.0396 pCi/g Potassium-40 10.5 +/-1.01 0.184 +/-1.01 0.425 pCi/g Radium-226 0.384 +/-0.0728 0.0346 +/-0.0728 0.0753 pCi/g Silver-108m U 0.0113 +/-0.018 0.0181 +/-0.018 0.0389 pCi/g Thallium-208 0.160 +/-0.0447 0.0201 +/-0.0447 0.0436 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -12.9 +/-9.03 7.92 +/-9.04 16.3 pCi/g SLN1 07/06/06 1046 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 90 (25%-/125%)

53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-008F Project: YANK01204 Sample ID: 164542013 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria
  • Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis I I I r I Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-009F Proiect: YANK01204 Sample ID: 164542014 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 12-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 31.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS Actinium-228 0.760 +/-0.142 0.0393 +/-0.142 0.0821 pCi/g MJHl 06/26/06 2358 537866 1 Americium-241 U 0.0365 +/-0.0489 0.0459 +/-0.0489 0.0937 pCi/g Bismuth-212 0.474 +/-0.180 0.081 +/-0.180 0.169 pCi/g Bismuth-214 0.563 +/-0.080 0.0203 +/-0.080 0.0422 pCi/g Cesium-134 U 0.00 +/-0.0352 0.015 +/-0.0352 0.0311 pCi/g Cesium- 137 0.397 +/-0.0495 0.0113 +/-0.0495 0.0235 pCi/g Cobalt-60 0.458 +/-0.0512 0.0108 +/-0.0512 0.0229 pCi/g Europium-152 U 0.00306 +/-0.033 0.0293 +/-0.033 0.0605 pCi/g Europium-154 U -0.0266 +/-0.0415 0.033 +/-0.0415 0.0695 pCi/g Europium-155 U 0.0544 +/-0.0564 0.0349 +/-0.0564 0.0715 pCi/g Lead-212 0.817 +/-0.0755 0.018 +/-0.0755 0.037 pCi/g Lead-214 0.630 +/-0.0768 0.0202 +/-0.0768 0.0418 pCi/g Manganese-54 U 0.0157 +/-0.0198 0.0108 +/-0.0198 0.0227 pCi/g Niobium-94 U 0.00147 +/-0.0115 0.0102 +/-0.0115 0.0211 pCi/g Potassium-40 13.2 +/-0.946 0.0857 +/-0.946 0.184 pCi/g Radium-226 0.563 +/-0.080 0.0203 +/-0.080 0.0422 pCi/g Silver-108m U 0.0022 +/-0.0118 0.0103 +/-0.0118 0.0213 pCi/g Thallium-208 0.236 +/-0.0379 0.0112 +/-0.0379 0.0233 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -7.24 +/-8.52 7.35 +/-8.53 15.1 pCi/g SLNI 07/06/06 1108 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 94 (25%-125%)

55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-009F Proiect: YANKO 1204 Sample ID: 164542014 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-01 OF Proiect: YANKO 1204 Sample ID: 164542015 Client ID: YANKOO I Matrix: SE Vol. Recv.:

Collect Date: 12-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 24.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.886 +/-0.280 0.109 +/-0.280 0.235 pCi/g MJHI 06/26/06 2133 537866 1 Americium-241 U 0.0401 +/-0.0443 0.0427 +/-0.0443 0.0881 pCi/g Bismuth-212 U 0.345 +/-0.308 0.216 +/-0.308 0.465 pCi/g Bismuth-214 UI 0.00 +/-0.117 0.104 +/-0.117 0.214 pCi/g Cesium-134 U 0.0774 +/-0.0559 0.0375 +/-0.0559 0.0798 pCi/g Cesium- 137 0.156 +/-0.0589 0.0307 +/-0.0589 0.0654 pCi/g Cobalt-60 0.153 +/-0.0827 0.0293 +/-0.0827 0.0648 pCi/g Europium-152 U 0.00473 +/-0.0824 0.073 +/-0.0824 0.153 pCi/g Europium-154 U 0.117 +/-0.161 0.104 +/-0.161 0.225 pCi/g Europium-155 U 0.0356 +/-0.0726 0.0668 +/-0.0726 0.138 pCi/g Lead-212 0.640 +/-0.0741 0.0404 +/-0.0741 0.0842 pCi/g Lead-214 0.528 +/-0.123 0.0492 +/-0.123 0.104 pCi/g Manganese-54 U 0.0199 +/-0.0374 0.0335 +/-0.0374 0.0716 pCi/g Niobium-94 U -0.0113 +/-0.031 0.0263 +/-0.031 0.0562 pCi/g Potassium-40 12.5 +/-1.19 0.255 +/-1.19 0.570 pCi/g Radium-226 0.527 +/-0.117 0.0544 +/-0.117 0.116 pCi/g Silver-108m U - -0.00285 +/-0.0268 0.023 +/-0.0268 0.0489 pCi/g Thallium-208 0.170 +/-0.0791 0.0318 +/-0.0791 0.0673 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -4.44 +/-8.42 7.19 +/-8.43 14.8 pCi/g SLN1 07/06/06 1129 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 96 (25%-125%)

57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-OIOF Proiect: YANK01204 Sample ID: 164542015 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-011F Proiect: YANK01204 Sample ID: 164542016 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 19.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0337 +/-0.0307 0.00784 +/-0.0311 0.0343 pCi/g LCW1 06/29/06 1420 542293 1 Curium-242 U (0.00634 +/-0.0168 0.00951 +/-0.0168 0.0416 pCi/g Curium-243/244 1.39 +/-0.192 0.00787 +/-0.268 0.0344 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -( 0.00347 +/-0.015 0.0116 +/-0.015 0.0429 pCi/g LCWI 06/28/06 1831 542294 2 Plutonium-239/240 U 0.00 +/-0.0142 0.00 +/-0.0142 0.0196 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 0.137 +/-0.947 0.914 +/-0.947 1.87 pCi/g LCW1 07/03/06 0815 542295 3 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.638 +/-0.158 0.0456 +/-0.158 0.0992 pCi/g MJHI 06/26/062133 537866 4 Americium-241 U 0.0559 +/-0.064 0.0573 +/-0.064 0.119 pCi/g Bismuth-212 0.415 +/-0.242 0.104 +/-0.242 0.224 pCi/g Bismuth-214 0.449 +/-0.087 0.0259 +/-0.087 0.0554 pCi/g Cesium-134 UI 0.00 +/-0.0377 0.0191 +/-0.0377 0.0406 pCi/g Cesium-137 U 0.00214 +/-0.0184 0.0138 +/-0.0184 0.0297 pCi/g Cobalt-60 U -0.0233 +/-0.017 0.0112 +/-0.017 0.0254 pCi/g Europium-152 U -0.0189 +/-0.045 0.0394 +/-0.045 0.083 pCi/g Europium-154 U -0.0121 +/-0.0562 0.0459 +/-0.0562 0.0999 pCi/g Europium-155 U 0.036 +/-0.0542 0.051 +/-0.0542 0.106 pCi/g Lead-212 0.691 +/-0.0767 0.0239 +/-0.0767 0.050 pCi/g Lead-214 0.473 +/-0.0774 0.0271 +/-0.0774 0.0572 pCi/g Manganese-54 U -0.00471 +/-0.017 0.0145 +/-0.017 0.0313 pCi/g Niobium-94 U 0.00946 +/-0.0154 0.0142 +/-0.0154 0.0303 pCi/g Potassium-40 12.5 +/-1.07 0.124 +/-1.07 0.278 pCi/g Radium-226 0.449 +/-0.087 0.0259 +/-0.087 0.0554 pCi/g Silver-108m U -0.00842 +/-0.0138 0.0115 +/-0.0138 0.0246 pCi/g Thallium-208 0.209 +/-0.0433 0.0129 +/-0.0433 0.0277 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0 0446 +/-0.0171 0.0187 +/-0.0171 0.0408 pCi/g BXF1 07/05/06 1218 541208 5 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 3.69 +/-6.09 4.96 +/-6.09 10.3 pCi/g EGDI 07/04/06 2212 542573 6 Liquid Scint C14, SolidAllFSS 59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-011F Prolect: YANKO 1204 Sample ID: 164542016 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis I Liquid Scint C14, SolidAllFSS Carbon- 14 U -0.104 +/-0.106 0.0938 +/-0.106 0.196 pCi/g ATH2 07/07/06 0636 545141 7 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -1.14 +/-17.3 13.2 +/-17.3 27.7 pCi/g SLN1 06/21/06 0918 538969 9 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -12.3 +/-10.3 8.94 +/-10.3 18.3 pCi/g SLNI 07/06/06 1151 541424 10 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0332 +/-0.224 0.189 +/-0.224 0.391 pCi/g EGD1 06/25/06 1429 540445 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-1, Modified 10 DOE RESL Ni-l, Modified 11 DOE EML HASL-300, Tc-02-RC.Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 93 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 82 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 86 (25%-/125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 53 (25%- 125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 88 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 87 (25%/--125%)

60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-01 IF Proiect: YANK01204 Sample ID: 164542016 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 80 (15/-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier

  • QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-014F Project: YANKO 1204 Sample ID: 164542017 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 19.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 0.0409 +/-0.0368 0.00926 +/-0.0372 0.0405 pCi/g LCWI 06/29/06 1420 542293 1 Curium-242 U 0.00987 +/-0.0193 0.00 +/-0.0194 0.0267 pCi/g Curium-243/244 U 0.00 +/-0.016 0.00 +/-0.016 0.0221 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.( +/-0.035 0.0355 +/-0.035 0.0888 pCi/g LCW1 06/28/06 1831 542294 2 Plutonium-239/240 U 0 +/-0.0276 0.0227 +/-0.0276 0.0632 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U +/-0.928 0.894 +/-0.928 1.83 pCi/g LCW1 07/03/06 0916 542295 3 Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS Actinium-228 +/-0.140 0.0406 +/-0.140 0.0868 pCi/g MJH1 06/26/06 2358 537866 4 Americium-241 U -0 +/-0.101 0.0856 +/-0.101 0.177 pCi/g Bismuth-212 +/-0.240 0.0907 +/-0.240 0.192 pCi/g Bismuth-214 +/-0.0691 0.0249 +/-0.0691 0.0521 pCi/g Cesium-134 U 0 +/-0.0188 0.0155 +/-0.0188 0.0326 pCi/g Cesium- 137 +/-0.0362 0.0124 +/-0.0362 0.0262 pCi/g Cobalt-60 0 +/-0.0272 0.0132 +/-0.0272 0.0286 pCi/g Europium-152 U 0.C +/-0.0405 0.0348 +/-0.0405 0.0723 pCi/g Europium-154 U -0 +/-0.0486 0.0402 +/-0.0486 0.0862 pCi/g Europium-155 U 0 +/-0.041 0.0398 +/-0.041 0.0819 pCi/g Lead-212 +/-0.076 0.0186 +/-0.076 0.0385 pCi/g Lead-214 +/-0.0758 0.0237 +/-0.0758 0.0495 pCi/g Manganese-54 U -0.C +/-0.0156 0.013 +/-0.0156 0.0276 pCi/g Niobium-94 U-0.0C +/-0.0148 0.0111 +/-0.0148 0.0234 pCi/g Potassium-40 +/-0.985 0.110 +/-0.985 0.242 pCi/g Radium-226 +/-0.0691 0.0249 +/-0.0691 0.0521 pCi/g Silver-108m U -0.C +/-0.0128 0.0111 +/-0.0128 0.0232 pCi/g Thallium-208 +/-0.037 0.0121 +/-0.037 0.0255 pCi/g Rad Gas Flow Proportional Counting GFPC,S90, solid-ALL FSS Strontium-90 U -0. +/-0.0137 0.0197 +/-0.0137 0.0423 pCi/g BXF1 07/05/06 1218 541208 5 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium 46.9 +/-8.04 5.06 +/-8.08 10.5 pCi/g EGD1 07/04/06 2244 542573 6 Liquid Scint C14, SolidAllFSS 62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-014F Project: YANK01204 Sample ID: 164542017 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAllFSS Carbon-14 U 0.00873 +/-0.113 0.0948 +/-0.113 0.198 pCi/g ATH2 07/07/06 0724 545141 7 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 5.21 +/-16.9 12.5 +/-16.9 26.3 pCi/g SLN1 06/21/06 0934 538969 9 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -10.4 +/-10.9 9.41 +/-10.9 19.3 pCi/g SLNI 07/06/06 1212 541424 10 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0446 +/-0.211 0.178 +/-0.211 0.368 pCi/g EGD1 06/25/06 1446 540445 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-0I Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-1, Modified 10 DOE RESL Ni-I, Modified 11 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 69 (15%-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 101 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 86 (25%-/125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 66 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 91 (I5%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 82 (25%-/125%)

63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-014F Project: YANKO1204 Sample ID: 164542017 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 83 (15%- 125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL; MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

64

I QUALITY CONTROL DATA 65

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: July 10, 2006 Client : Connecticut Yankee Atomic Power Page 1 of 9 362 Injun Hollow Rd East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder: 164542 Parmname NOM Samnle Ouial tIC tJnit~ RPD% RF.C% Ranf'e Anist Date Time Parmname NOM Samnle Oual OC Units RRPD% REC%

Rad Alpha Spec Batch 542293 QC1201121833 165557001 DUP Americium-241 U 0.0069 0.0442 pCi/g 146 (0%- 100%) LCWI 06/29/06 14:20 Uncert: +/-0.013 +/-0.0412 TPU: +/-0.013 +/-0.0417 Curium-242 U 0.00685 U -0.00258 pCi/g 442 (0%- 100%)

Uncert: +/-0.0134 +/-0.0217 TPU: +/-0.0135 +/-0.0217 Curium-243/244 U 0.00332 U 0.0176 pCi/g 137 (0%- 100%)

Uncert: +/-0.0132 +/-0.0282 TPU: +/-0.0132 +/-0.0283 QCI201121835 LCS Americium-241 2.68 2.84 pCi/g" 106 (75%-125%)

Uncert: +/-0.266 TPU: +/-0.426 Curium-242 U 0.00 pCi/g Uncert: +/-0.0129 TPU: +/-0.0129 Curium-243/244 3.26 3.05 pCi/g 94 (75%-125%)

Uncert: +/-0.276 TPU: +/-0.452 QC1201121832 MB Americium-241 U 0.0049 pCi/g Uncert: +/-0.0157 TPU: +/-0.0157 Curium-242 U 0.00 pCi/g Uncert: +/-0.0141 TPU: +/-0.0141 Curium-243/244 0.0424 pCi/g Uncert: +/-0.034 TPU: +/-0.0343 QC1201121834 165557001 MS Americium-241 2.73 U 0.0069 2.70 pCi/g 99 (75%-125%)

Uncerl: +/-0.013 +/-0.250 TPU: +/-0.013 +/-0.398 Curium-242 U 0.00685 U 0.00644 pCi/g Uncert: +/-0.0134 +/-0.0126 TPU: +/-0.0135 +/-0.0126 Curium-243/244 3.33 U 0.00332 3.12 pCi/g 94 (75%-125%)

Uncert: +/-0.0132 +/-0.269 TPU: +/-0.0132 +/-0.447 Batch 542294 QC1201121837 165557001 DUP Plutonium-238 U 0.0117 U 0.0162 pCi/g 32 (0% - 100%) .CWI 06/28/06 23:03 66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164542 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 542294 Uncert: +/-0.0336 +/-0.0281 TPU: +/-0.0336 +/-0.0281 Plutonium-239/240 U 0.00369 U 0.0159 pCi/g 125 (0%- 100%)

Uncert: +/-0.0147 +/-0.0221 TPU: +/-0.0147 +/-0.0221 QC1201121839 LCS Plutonium-238 U 0.00893 pCi/g (75%-125%) 06/28/06 23:03 Uncert: +/-0.0143 TPU: +/-0.0143 Plutonium-239/240 2.48 2.10 pCi/g 85 (75%-125%)

Uncert: +/-0.202 TPU: +/-0.302 QC1201121836 MB Plutonium-238 U -0.00137 pCi/g 06/28/06 23:03 Uncert: +/-0.0115 TPU: +/-0.0115 Plutonium-239/240 U 0.00435 pCi/g Uncert: +/-0.0115 TPU: +/-0.0115 QC1201121838 165557001 MS Plutonium-238 U 0.0117 0.0336 pCi/g (75%-125%) 06/28/06 23:03 Uncert: +/-0.0336 +/-0.0295 TPU: +/-0.0336 +/-0.0297 Plutonium-239/240 2.52 U 0.00369 2.28 pCi/g 91 (75%-125%)

Uncert: +/-0.0147 +/-0.242 TPU: +/-0.0147 +/-0.355 Batch 542295 QC1201121841 165557001 DUP Plutonium-24 I U 0.395 U 1.16 pCi/g 0 (0% - 100%) -CWI 07/03/06 16:27 Uncert: +/-1.29 +/-1.89 TPU: +/-1.29 +/-1.89 QC1201121843 LCS Plutonium-241 35.0 27.3 pCi/g 78 (75%-125%) 07/03/06 18:31 Uncert: +/-1.43 TPU: +/-3.02 QC1201121840 MB Plutonium-241 U 0.499 pCi/g 07/03/06 15:26 Uncert: +/-0.891 TPU: +/-0.893 QC1201121842 165557001 MS Plutonium-241 35.3 U 0.395 31.7 pCi/g 90 (75%-125%) 07/03/06 17:29 Uncert: +/-1.29 +/-1.58 TPU: +/-1.29 +/-3.43 Rad Gamma Spec Batch 537866 QC1201111186 164542001 DUP Actinium-228 0.865 1.05 pCi/g 19 (0%- 100%) MJHI 06/28/06 22:50 Uncert: +/-0.203 +/-0.191

+/-0.191 67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164542 Page 3 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 537866 TPU: +/-0.203 Americium-241 U 0.0409 U -0.00664 pCi/g 277 (0% - 100%)

Uncert: +/-0.0866 +/-0.123 TPU: +/-0.0866 +/-0.123 Bismuth-212 0.562 0.777 pCi/g 32 (0% - 100%)

Uncert: +/-0.221 +/-0.333 TPU: +/-0.221 +/-0.333 Bismuth-214 0.556 0.668 pCi/g 18 (0% - 100%)

Uncert: +/-0.116 +/-0.0991 TPU: +/-0.116 +/-0.0991 Cesium- 134 U 0.0263 U! 0.00 pCi/g 104 (0%- 100%)

Uncert: +/-0.0382 +/-0.0355 TPU: +/-0.0382 +/-0.0355 Cesium-137 0.170 0.173 pCi/g 2 (0%- 100%)

Uncert: +/-0.0433 +/-0.0473 TPU: +/-0.0433 +/-0.0473 Cobalt-60 0.239 0.175 pCi/g 31 (0% - 100%)

Uncert: +/-0.0465 +/-0.0566 TPU: +/-0.0465 +/-0.0566 Europium- 152 U 0.0167 U 0.0185 pCi/g 10 (0%- 100%)

Uncert: +/-0.0586 +/-0.0562 TPU: +/-0.0586 +/-0.0562 Europium- 154 U -0.0172 U -0.00751 pCi/g 78 (0%- 100%)

Uncert: +/-0.0755 +/-0.0707 TPU: +/-0.0755 +/-0.0707 Europium-155 U 0.0597 U 0.0287 pCi/g 70 (0% - 100%)

Uncert: +/-0.0887 +/-0.0603 TPU: +/-0.0887 +/-0.0603 Lead-212 0.938 0.904 pCi/g 4 (0%- 20%)

Uncert: +/-0.0991 +/-0.0688 TPU: +/-0.0991 +/-0.0688 Lead-214 0.688 0.671 pCi/g 3 (0%-20%)

Uncert: +/-0.114 +/-0.0836 TPU: +/-0.114 +/-0.0836 Manganese-54 U 0.0262 U 0.0253 pCi/g 3 (0%- 100%)

Uncert: +/-0.025 +/-0.0234 TPU: +/-0.025 +/-0.0234 Niobium-94 U -0.00291 U 0.0118 pCi/g 331 (0% - 100%)

Uncert: +/-0.0206 +/-0.0201 TPU: +/-0.0206 +/-0.0201 Potassium-40 14.4 14.3 pCi/g I (0%- 20%)

Uncert: +/-1.33 +/-1.02 TPU: +/-1.33 +/-1.02 Radium-226 0.556 0.668 pCi/g 18 (0% - 100%)

Uncert: +/-0.116 +/-0.0991 TPU: +/-0.116 +/-0.0991 Silver- 108m U -0.00368 U -0.0118 pCi/g 105 (0%- 100%)

Uncert: +/-0.0205 +/-0.0182 68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164542 Page 4 of 9 Parmname NOM Sample Qual[ QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 537866 TPU: +/-0.0205 +/-0.0182 Thallium-208 0.327 0.317 pCi/g 3 (0%- 100%)

Uncert: +/-0.0551 +/-0.0499 TPU: +/-0.0551 +/-0.0499 QC1201111187 LCS Actinium-228 U -0.00725 pCi/g 06/26/06 20:54 Uncert: +/-0.547 TPU: +/-0.547 Americium-241 23.4 25.4 pCi/g 109 (75%-125%)

Uncert: +/-4.04 TPU: +/-4.04 Bismuth-212 U 0.122 pCi/g Uncert: +/-1.02 TPU: +/-1.02 Bismuth-214 U -0.0901 pCi/g Uncert: +/-0.245 TPU: +/-0.245 Cesium- 134 U 0.0536 pCi/g Uncert: +/-0.148 TPU: +/-0.148 Cesium- 137 9.63 9.82 pCi/g 102 (75%-125%)

Uncert: +/-0.782 TPU: +/-0.782 Cobalt-60 14.9 15.0 pCi/g 100 (75%-125%)

Uncert: +/-1.13 TPU: +/-1.13 Europium- 152 U -0.193 pCi/g Uncert: +/-0.334 TPU: +/-0.334 Europium- 154 U 0.107 pCi/g Uncert: +/-0.334 TPU: +/-0.334 Europium-155 U -0.15 pCi/g Uncert: +/-0.350 TPU: +/-0.350 Lead-212 U -0.0252 pCi/g Uncert: +/-0.185 TPU: +/-0.185 Lead-214 U -0.025 pCi/g Uncert: +/-0.223 TPU: +/-0.223 Manganese-54 U 0.0331 pCi/g Uncert: +/-0.154 TPU: +/-0.154 Niobium-94 U 0.0941 pCi/g Uncert: +/-0.127 TPU: +/-0.127 Potassium-40 U 1.25 pci/g 69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164542 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 537866 Uncert: +/-1.28 TPU: +/-1.28 Radium-226 U -0.0901 pCi/g (75%-125%)

Uncert: +/-0.245, TPU: +/-0.245 Silver-I 08m U -0.0742 pCi/g Uncert: +/-0.115 TPU: +1-0.115 Thallium-208 U 0.0403 pCi/g Uncert: +/-0.124

. TPU: +/-0.124 QC1201111185 MB Actinium-228 U 0.0114 pCi/g 06/28/06 22:49 Uncert: +/-0.0487 TPU: +/-0.0487 Americium-241 U -0.0051 pCi/g Uncert: +/-0.0126 TPU: +/-0.0126 Bismuth-212 U 0.078 pCi/g Uncert: +/-0.093 TPU: +/-0.093 Bismuth-214 U 0.0244 pCi/g Uncert: +/-0.0241 TPU: +/-0.0241 Cesium- 134 U 0.00203 pCi/g Uncert: +/-0.0122 TPU: +/-0.0122 Cesium- 137 U 0.0037 pCi/g Uncert: +/-0.0112 TPU: +/-0.0112 Cobalt-60 U -0.00123 pCi/g Uncert: +/-0.0121 TPU: +/-0.0121 Europium- 152 U -0.00865 pCi/g Uncert: +/-0.0314 TPU: +/-0.0314 Europium- 154 U 0.016 pCi/g Uncert: +/-0.0325 TPU: +/-0.0325 Europium- 155 U -0.0182 pCi/g Uncert: +/-0.0238 TPU: +/-0.0238 Lead-212 U 0.0187 pCi/g Uncert: +/-0.0181 TPU: +/-0.0181 Lead-214 U 0.0118 pCi/g Uncert: +/-0.0221 TPU: +/-0.0221 70

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164542 Page 6 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 537866 Manganese-54 U -0.00601 pCi/g Uncert: +/-0.0127 TPU: +/-0.0127 Niobium-94 U -0.00535 pCi/g Uncert: +/-0.0123 TPU: +/-0.0123 Potassium-40 UI 0.00 pCi/g Uncert: +/-0.246 TPU: +/-0.246 Radium-226 U 0.0244 pCi/g Uncert: +/-0.0241 TPU: +/-0.0241 Silver-I 08m U -0.0068 pCi/g Uncert: +/-0.0102 TPU: +/-0.0102 Thalliun-208 U 0.013 pCi/g Uncert: +/-0.0121 TPU: +/-0.0121 Rad Gas Flow Batch 541208 QC1201119318 164551004 DUP Strontium-90 U -0.0131 U -0.0114 pCi/g 0 (0% - 100%) BXFI 07/05/06 12:18 Uncert: +/-0.0146 +/-0.0131 TPU: +/-0.0146 +/-0.0131 QCI201119320 LCS Strontium-90 1.38 1.27 pCi/g 92 (75%-125%) 07/05/06 14:24 Uncert: +/-0.0859 TPU: +/-0.0943 QC1201119317 MB Strontium-90 U 0.00252 pCi/g 07/05/06 12:18 Uncert: +/-0.0114 TPU: +/-0.0114 QC1201119319 164551004 MS Strontium-90 2.55 U -0.0131 2.38 pCi/g 93 (75%-125%) 07/05/06 14:25 Uncert: +/-0.0146 +/-0.153 TPU: +/-0.0146 +/-0.169 Rad Liquid Scintillation Batch 538969 QC1201113888 163741008 DUP Iron-55 U 21.1 U -1.03 pCi/g 0 (0% - 100%) SLNI 06/21/06 10:23 Uncert: +/-18.3 +/-16.3 TPU: +/-18.5 +/-16.3 QC1201113890 LCS Iron-55 575 529 pCi/g 92 (75%-125%) 06/21/06 10:40 Uncert: +/-44.0 TPU: +/-86.2 QC1201113887 MB Iron-55 U 5.38 pCi/g 06/21/06 09:51 71

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164542 Page 7 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 538969 Uncert: +/-26.8 TPU: +/-26.8 QCl201113889 163741008 MS Iron-55 594 U 21.1 546 pCi/g 92 (75%-125%) 06/21/06 10:07 Uncert: +/-18.3 +/-33.8 TPU: +/-18.5 +/-74.0 Batch 540445 QC1201117553 165011005 DUP Technetium-99 U -0.151 U 0.0323 pCi/g 0 (0% - 100%) EGDI 06/25/06 18:35 Uncert: +/-0.353 +/-0.398 TPU: +/-0.353 +/-0.398 QC1201117555 LCS Technetium-99 12.7 12.1 pCi/g 96 (75%-125%) 06/25/06 19:07 Uncert: +/-0.465 TPU: +/-0.552 QC1201117552 MB Technetium-99 U 0.0683 pCi/g 06/25/06 18:18 Uncert: +/-0.184 TPU: +/-0.184 QC1201117554 165011005 MS Technetium-99 22.4 U -0.151 20.2 pCi/g 90 (75%-125%) 06/25/06 18:51 Uncert: +1-0.353 +/-0.830 TPU: +/-0.353 +/-0.969 Batch 541424 QC1201119884 164542011 DUP Nickel-63 U -13 U -11.5 pCi/g 0 (0%- 100%) SLNI 07/06/06 12:55 Uncert: +/-9.02 +/-9.66 TPU: +/-9.03 +/-9.67 QC1201119886 LCS Nickel-63 512 408 pCi/g 80 (75%-125%) 07/06/06 13:38 Uncert: +/-16.6 TPU: +/-20.9 QC1201119883 MB Nickel-63 U -7.86 pCi/g 07/06/06 12:34 Uncert: +/-8.73 TPU: +/-8.73 QC1201119885 164542011 MS Nickel-63 553 U -13 474 pCi/g 86 (75%-125%) 07/06/06 13:17 Uncert: +/-9.02 +/-19.4 TPU: +/-9.03 +/-24.7 Batch 542573 QC1201122405 165702005 DUP Tritium U 2.71 U 4.56 pCi/g 0 (0% - 100%) EGDI 07/05/06 04:00 Uncert: +/-6.22 +/-6.50 TPU: +/-6.22 +/-6.50 QC1201122407 LCS Tritium 61.0 62.7 pCi/g 103 (75%-125%) 07/05/06 05:03 Uncert: +/-8.39 TPU: +/-8.46 72

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn QC Summary Workorder: 164542 Page 8 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Liquid Scintillation Batch 542573 QC1201122404 MB Tritium U 8.19 pCi/g 07/05/06 03:28 Uncert: +/-6.12 TPU: +/-6.12 QC1201122406 165702005 MS Tritium 63.4 U 2.71 71.0 pCi/g 112 (75%-125%) 07/05/06 04:32 Uncert: +/-6.22 +/-8.48 TPU: +/-6.22 +/-8.57 Batch 545141 QC1201128389 165011012 DUP Carbon-14 U -0.20 U -0.23 pCi/g 0 (0% - 100%) ATH2 07/07/06 18:35 Uncert: +/-0.313 +/-0.300 TPU: +/-0.313 +/-0.300 QC1201128391 LCS Carbon- 14 7.13 6.63 pCi/g 93 (75%-125%) 07/07/06 19:40 Uncert: +/-0.504 TPU: +/-0.514 QC1201128388 MB Carbon-14 U -0.0833 pCi/g 07/07/06 17:48 Uncert: +/-0.098 TPU: +/-0.098 QC1201128390 165011012 MS Carbon- 14 21.5 U -0.20 20.9 pCi/g 97 (75%-125%) 07/07/06 19:23 Uncert: +/-0.313 +/-1.56 TPU: +/-0.313 +/-1.59 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL 73

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164542 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time A

h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

74

General Narrative 1

CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 168404 SDG: MSR #06-0652, 06-0675, 06-0687, 06-0688, 06-0707, 06-0743, 06-0755 August 15, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address:

P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:

2040 Savage Road Charleston, South Carolina 29407 Telephone Number:

(843) 556-8171 Summary:

Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on May 5, May 9, May 12, May 17, May 26, June 2, June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP,INC.

P.O. Box 30712 ° Charleston, SC 29417 ° 2040 Savage Road (29407)

Page 2 of 105 Phone (843) 556-8171

  • Fax (843)1766-1178 °www.gel.com

168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F Items of Note:

At the request of Dale Randall on July 20, 2006, GEL analyzed the above samples according to the spreadsheet in the attached email.

Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request:

Seven soil samples were reanalyzed for FSSALL, except gamma and Sr-90.

Four soil samples were reanalyzed for FSSALL, except gamma and Ni-63.

Two soil samples were reanalyzed for FSSALL, except gamma.

Two soil samples were reanalyzed for FSALL, except gamma, Sr-90 and Ni-63.

Internal Chain of Custody:

Custody was maintained for the sample(s).

Data Package:

The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax (843) 766-1178
  • www.gel.com Page 3 of 105 I:

Additional HTD analyses

Subject:

Additional HTD analyses KP99c)WIt From: "Dale Randall" <randall @cyapco.com>

Date: Thu, 20 Jul 2006 11:04:54 -0400 To: "Cheryl Jones" <cj @gel.corn>

CC: "Clyde Newson" <Newson@CYAPCO.com>, "John McCarthy" <McCarthy@ CYAPCO.com>

Cheryl:

Per our earlier discussion, attached is a list of samples that we would like to have analyzed to the FSSALL protocol. I have included a list of test protocols performed on each sample to date. Once you have had an opportunity to determine our options for each sample please call or e-mail me at your convenience.

Thank You, Dale (860) 267-3133 Content-Description: GEL FSSALL analyses request.x Is GEL FSSALL analyses request.xls. Content-Type: appl)cat)onlvnd.ms-excel Content-Encoding: base64 I oflI Page 4 of 105 8/2/2006 7:04 PM

flnny, To be done Previous rGEL ID CY sample location IDs FSS Gam Sr-90 Ni-63 Am Pu Sr9O Pu241 Fe55 N163 Tc99 H3 C14 M164220008 9106-0002-007F x x x x x x x x x x 164220012 9106-0002-01iF x x x x. x x x x X x 0 162335004 9106-0003-004F x x x x x x x x x x 162335014 9106-0003-015F x x x x x x x x x x 162832015 9106-0004-005F x x x x x x x x x x 162832009 9106-0004-015F x x x x x x x x x x 162485008 9106-0005-01OF x x x x x x x x x x 162485011 9106-0005-014F x x x x I x x x x x 162850014 9106-0006-005F x x x x x x x x x x 163741005 9106-0008-006F x x x x x x x x x x 163741009 9106-0008-008F x x x x x x x x x x 164542008 9106-0009-002F x x x x x x x x x x 164542003 9106-0009-017F x x x x x x x x x x 163105009 9106-0010-001 F x x x x x x x x x x 1163105016 9106-0010-012F x x x x x x x x x x

Chain of Custody and Supporting Documentation Page 6 of 105

kV61 16 Sý q6 Lý Health Physics Procedure GPP-GGGR-RS 104-003 -Attachment B-CY-001 Major P eu Chain of Custody Form 1006-Major Connecticut Yankee Atomic Power Company No. 2006-00371 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, .State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones cc, W Priority: 0 30 D. [] 14 D. [] 7 D. Container Sample Size-,.

Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-OOIF 5/17/06 10:42 SE C BP x x Transferred from COC 2006-00357 9106-0002-002F 5118106 09:43 SE C BP X Transferred from COC 2006-00361 9106-0002-003F 5/18/06 10:14 SE C BP X X Transferred from COC 2006-00361 9106-0002-004F 5/18/06 10:39 SE C BP X X Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP X X Transferred from COC 2006-00364 9106-0002-006F 5/18/06 13:14 SE C BP x X Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP X X Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:3i7 SE C BP X x Transferred from COC 2006-00364 9106-0002-008F 5/18/06 114:04 SE C BP X x Transferred from COC 2006-00364 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA [] Radwaste QA [I Non QA Samples Shipped Via: Internal 15 Fed Ex Container ol UPS Temp.:

Deg. C E Hand Custody Sealed?

I e uDate/Time 2) P3.ived By Date/rime Custody Seal S c\'O intact?

IOther 3Ielinquishi ed B ) Date/Tim e 4) Received By Date/Tim e Bill of Lading Y Bill of Ladfing #

5)Reinuihe B Dt'Tme

5) Relinquished By Date/Ti 16) 6 Received i ByB Date/Time Doa 57/ &

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form N.20-07 No. 2006-00372 00 362 Injun Hollow Road, East Hampton, CT 06424 o 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 c) 843 556 8171. Attn. Cheryl Jones I Q Priority: Z 30 D. [] 14 D.E]7 D. Container

. Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample M 9106-0002-009F 5/18/06 14:28 SE C BP x Transferred from COC 2006-00364 9106-0002-OIOF 5/18/06 14:50 SE C BP x X Transferred from COC 2006-00364 9106-0002-011F 5/19/06 08:10 SE C BP x x Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP X x Transferred from COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X X Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP x x Transferred from COC 2006-00365 9106-0002-014FS 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:29 SE C BP x x Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X X - Transferred from COC 2006-00365 NOTES: P0 #: 002332 MSR #: 06- SSWP# NA 23 LTP QA [] Radwaste QA El Non QA Samples Shipped Via: Internal SFed Ex Container UPS Temp.:

Deg. C Dl Hand Custody Sealed?

I Relin ishe Date/Time 2)Repived By Dat1Time Custody Seal

~z1Q&1~

~ ,gi~ CL~[]E Other Intact?

3)'}(elinquished By Date/Time 4) Received By Date/Time BillofLading_# _Y Y N 0

5) Relinquished By "Date/Time 6) Received By Date/Time Bill of Lading-#

"i7o0 't/'t/3 *702

Connecticut Yankee Statement of Work for Analytical Lab Services L .CY-ISC-SOW-001 Figure 1. Sample Check-in List DatefTime Received:- .

SDG#: - 0(* - "-p5 '-

Work Order Number: C4 2-b'2 ".

Shipping Ccltainer IDYIO &' C/[(5 9/O Chain of Custody# - c r3 9

1. Custody Seals oii shipping container intact..? Yes jkVNo[I
2. Custody Seals dated and signed? YesANo
3. Chain-of-Custody record present? " Yes ¢A No t ]

.4. Cooler temperature '

5. Vermiculitelpacking materials is: Wet [ ] Dry
6. - Number of samples in shipping container: ______
7. Sample holding times exceeded? Yes []
8. Samples have:
  • tape *hazard labels

_.*custody seals _ appropriate sample labels

9. Samples are-S_)in good condition -leaking

.broken -have air bubbles

10. Were any anomalies identified in sample receipt? Yes [] NoX]

11.. .Description of anomalies (include sample numbers):

A Sample Custodian/Laboratory: Date.:______________

Telephoned to: On . B Page 9 of 105

Connecticut Yankee Statement of Work for Analytical Lab Services -CY-ISC-SOW-001 Figure 1. Sample Check-in List.

Date/Time Received,',ý "6 C,'_

Work Order Number:

Shipping Ccfntainer ID 1 q t/ 5 i.T Chain of Custody tJQ2V (aQV37 '

I. Custody Seals oxi shipping container intact?... Yes No []

2. Custody Seals dated and signed? Yes.1 No [1
3. Chain-of-Custody record present? ( Yes No

.4. Cooler temperature O(.) '

Dry ip] C '

5. Vermiculite/packing materials is: Wet [

~J.

6: Number ofsamples in shipping container:. *__

____ *____
7. Sample holding. times excieeded? - -Yes []No..

.9. Sa~s hve'.:

a.___.-hazard labels custody seals -appropriate sample labels

9. Samples are:

.Xiin good condition leaking

. _broken .ave air bubbles

10. Were any anomalies identified in sample receipt? Yes (I No
11. *.Description of anomalies (include sample numbers):

Sample Custodian/Laboratory: *(>.1L.' 1, Date: -

Telephoned to: On By.

Page 10 of;105

SAMLERECEIPT & REVIEW FORM mit I-Clet(,Ap4,r4ýnW0!-SDG/ARCOC/Work Order:

DateReceved:PM(A) Review (ensure non-conforming items are resolved prior to signing);

[Received By:

Sample Receipt Criteria Comments/Qualiliers (Required for Non-Conforming Items)

Shipping containers received intact Circle Applicable: seals broken damaged comainer lea$g container other (describe) and sealed? 7 Circle # ice bags blue icee dry ice none other describe)

Samples requiring cold Coolant 2 preservation within (4 +/- 2 C)?

Record preservation inethod.

Chain of custody documents included with shipment? rnt imicApplica ,s bren damaged container eakingconainer othe (describe)

Sample containers intact and sealed? ,_,___ID's. __ontainersaffe___d___dobservedpH:

5 Samples requiring chemical Sa IDs. containers affected and observed pH:

preservation at proper pH? ......

VOA vials free of headspace Sample 11's and containers affected:

(defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) .,,,"

and tes affected:

Id's 8 Samples received wi - holding time? _ ___ ___

9 Sample ID's OC match ID's sample ID's and containers affected:

on bottles?

Date & me on COC match date Sample ID's affected:

ti on bottles? ______ID'___ffe__ed_

Nu ber of containers received Sample ID's affected match number indicated on COC?

COC form is properly signed in relinquished/reccived sections? Co " .

Air Bill ,Tracking #'s, &

Suspected Hazard Information S t;.=. j *If > x2 area background is observed on samples identified as "non-Z dic regulated/non-radioactive", contact the Radiation Safety group for further

__ investigation.

A lRadiological Classification? Maximum. Counts Observed*:' C.r,"

B fPCB Regulated? V Comments:

IShipped as DpT Hazardous C IMaterial? If yes, contact Waste Hazard Class Shipped:

UN#:

Manager or PSH Manager.

PM (or PMA) review of Hazard classiticaiion: Initials Date: W 17L('.

(I Page 11 of 105

SAMPLE RECEIPT & REVIEW FORM PM use only Ccnr))_'"A--1C( *3SDG/ARCOC/Work Order: / ZIZZ Cicent:

Date Received: - 0' O~o PM(A) Review ( -

c nonconfor *ngI are resolved prior to signing):

Received By:

Sample Receipt Criteria 4 Z Comments/Qualil equired for Non-Conforming Items) damaged container leaking container other (describe) containers received intact Cir-e Applicable: seals br IShipping i and sealed?7 a boe ice dry ice none other describe)

F !u,A

&,s I " 9aU1- ut*ass 2 ]preservation within (4 +/- 2 C)?

_ Record preservation method. I I /I 3 Chain of custody documents included with shipment?

C pplicable: seals broken damaged container leaking container other (describe) 4 Sample containers intact and

,sealed?

gample ID's. 'conainers affected and observed pH:

sSamples requiring chemical Ipreservation at proper pH?

Sample ID's and containers affected:

616(defined VOA vials as free

< 6mamof headspace bubble)?

, l -Tu

/

- a 7 (ifIAreyes, inumediately deliver to ..

Encore containers present?

VIVOA laboratory) 8 Samples received within holdin Itime?' I d's and tests affected.

9 S ample ID's on COC mat ID's Sample ID's and contaners affected:

_ on bottles?/

1Date & time on COC ich date Sample ID's affected:

& time on bottles?

Number of containerreceived Sample ID's affected:

match number indic ted on COC?

COC form is pro ny signed in

& 1,6

. re.nuished/recve"

.. sections?.oo(,

14'24i Bill ,Tracking #'s, &

AAdditional Comments

--

" > RSO RAD Receipt#

Suspected Hazard Intormation o *If > x2 area background is observed on samples identified as "non-for further contact the Radiation Safety group

-2zregulated/non-radioactive-,

A_at.

  • -*gu RailgclMaaximurnCounts o ens Observed*:_ ,.

CMaterial? If yes, contact Waste Hazard Class Shipped:

,'Manager or ESH Manager. UN#:

PM (or PMA) review of Hazard classification: Initials Date:

Page 12 of 105

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Chain of Custody Form No. 260 Connecticut Yankee Atomic Power Company

- 362 Injun Hollow Road, East Hampton, CT 06424 4 ':g.4 [ '/

860-267-2556 1_____________________________________________

Project Name: Haddam Neck Decommissioning Analyses Requested _Lab.Use Only.

Contact Name & Phone: 'onu0 ents:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories .

2040 Savage Road. Charleston SC. 29407 9.

843 556 8171. Attn. Cheryl Jones Cn W Priority: Z 30 D.[E] 14 D. E] 7 D. Container Sample Size-Media Type &Type L m Sample Designation Date Time Code Code Code Comment, Preservation Lab Sampi*ig.

"9106-0003-01F 4/24/06 14:13 BP x Transferred from C.C2006-00221 i'z 9106-0003-002F 4/24/06 14:39 SE C BP X Transferred from COC2006-00221

-!?9106-0003-003F 4/24/06 15:01 SE C BP X Transferred from COC2006-00221 9106-0003-004F 4/25/06 08:41 SE C BP X Transferred from C0C2006-00223 9106-0003-004FS 4/25/06 08:41 SE C B3P x Transferred from COC2006-00223 9106-0003-005F 4/25/06 09:21 SE C BP X Transferred from COC2006-00223 9106-0003-006F 4/25/06 09:46 SE C BP X Transferred from COC2006-00223

_ 9106-0003-007F 4/25/06 10:28 SE C BP X Transferred from COC2006-00223 9106-0003-008F 4/25/06 11:15 SE C BP X Transferred from COC2006-00223 NOTES: PO #: 002332 MSR #: 06- SSWP#NA Z LTP QA E Radwaste QA E Non QA Samples Shipped Via: ":',Jnternbj1 Coi6t r Combined samples 9106-0003-003F taken on 4/25/06 @08:19 and 9106-0003-003FB taken on 4/25/06 @ 08:19 in order to have sufficient sample for counting. (Z[]UPS Fed Ex e mp.

4..*.:..:""

-. Deg

  • '

[ Hand Custody :Sealed? .::

1) Relinquished By Date/Time 2)/ec ived By Custody cDatefTime Se61 Intact?

-.5- "c0g//.3.3O , d j(rl _ El Other

3) Relinquished By Date/Time 4) Received By -,a./Time_.__"__ .. ) ..N.

Bill of Lading #

5) Relinquished By Date/Time 6) Received By Date/Time .- 92O- '*2T- 02 4*)

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major (b Chain of Custody Form No. 2006-00313 Connecticut Yankee Atomic Power Company CD 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 --

/(.Z:3

_____-- _____o/, /

Project Name: Haddam Neck Decommissioning Analyses Requested US&R  :

Contact Name & Phone: .

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones ..

Priority: Z 30 D. E 14 D. [ 7 D. Container Sample Size- ._,__.._._-___._,. ._._

Media Type &Type li S !i *i Sample Designation Date Time Code Code Code Comment, Preservation pie 9106-0003-009F 9106-0003-010F 4/25/06 13:00 SE C BP xX ' Transferred from COC 2006-00236  ;'"

4/25/06 13:23 SE C BP "'

-TransfcrredfromCOC2006-00236 S9106-0003-00FS 4/25/06 13:23 SE C BP X - Transferred from COC 2006-00236 010 9106-0003-012F 4/25/06 15:12 SE C BP Transferred from COC 2006-00236 9106-0003-013F 4/25/06 14:21 SE C BP xTrnsferred from COC 2006-00236 9106-0003-014F 4/25/06 14:48 SE C BP x Transferred from COC 2006-00236 01 9106-0003-015F 4/26/06 08:16 SE C BP x Transferred from COC 2006-002376 9106-0003-016F 4/26/06 09:41 SE C BP x Transferred from COC 2006-00237 9106-0003-017F 4/26/06 09:18 SE C BP X ""_Transferred from COC 2006-00237 I ,'Qf-lflfAO'*-O1RF 4/26/06 0R:59 gE IC BP x Transferred from COu 2006-002-7

,9106-0003-01 8F 4/26/06 08:59 SE C BP NOTES: PO #:002332 MSR #: 06- 0& SSWP#NA Z LTP QA LI Radwaste QA jj Non QA Samples Shipped Via:

[ Fed Ex 'eTernp.;' ",Pg

[] UPS I] Hand A,r

1) Relinquished By Date ime 2)Received By Dat* fime El Other
3) Relinquished By Date/Time 4) Received By Dafe/Time Bill of Lading 4
  • t912-Sg/j2- 0261

cvxJ" ~I Connecticut Yankee CY-ISC-SOW-001 Statement of Work for Analytical Lab Services Figure 1. Sample Che*k-in List Date/Time Received: .

t4 ,0) $

SDG#: /AA6f&,4-C)

Work Order Number: i Shipping Ccohtainer IDl: 1' 0 li IChain of Custgdy # ,G _

t. Custody Seals on shipping container intact?.- -Yes t No
2. Custody Seals dated and signed? Yes[ No
3. Chain-of-Custody record present? Yes No [
4. Cooler temperature
  • CIl C-
5. Vermiculite/packing materials is: Wet DrynI] _

6- Number of samples in shipping container: [i (A§ico I (I1 i ,

7- Sample holding times exceeded? Yes [ No

8. Sampleshot S"tp * . .hazard labels

.J custody seals -appropriate sample labels

9. Samples are-good condition *leaking

-broken -have air bubbles

10. Were any anomalies identified in sample receipt? Yes ' ] No
11. .Description of anomalies (include sample numbers): -_

Sample, Custodian/Laboratory: (C),(vY (:" tt.

Telephoned to: On By -

Page 15 of 105

SAMPL RECEIPT & REVIEW FORM uaGV 3~~5 Client: SDG/ARCOC/Work Order:

DaeReceived: roý 45 5 6P()Rve ensure ne fo

  • a re resolved prior to siging)l:

Received By: Cý "C*r _'-

Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items) 1 Shipping containers received intact Circle Applicable: seals broken damaged container leaking contalner oter (describe) and sealed? C Samples requiring cold Circl Coolnt U ice bagt blue e dr ice none 2 preservation within (4 +/- 2 C)?

Record preservation method. _ _ _ _ _ _ _ _ _"_ Pen__

_ _

Chain of custody documents included with shipment?

4 Sample containers intact and Circle Applicable: seals broken damaged container leaking comainer odwe (describe) sealed?

5 Samples requiring chemical Sample ID's. containers affected and observed pH:

_ preservationat proper pH? ....

VOA vials free of headspace Sample ID's and containers affected:

(defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) --

Samples received within holding and tests affected; rd's 8 time,?...

.

9 Sample ID's on COC match ID's Sample ID's and containers affected:

on bottles?

Date & time on COC match date Sample ID's affected:

i&time on bottles?

received Sample ID's affected:

Number match of containers number indicated on COC?

12COC form is properly signed in relinquished/received sections?

Air Bill ,Tracking #'s, & jCY '"c iLO ZO ?-(A Additional Comments C ?7..-

,aWl V rd RSO RAD Receipt #

0 *I"jý A c *f>

-t x2 area background is observed on samples identified as "non-Suspected Hazard Information S Hazar regulated/non-radioactive", contact die Radiation Safety group for further

_ _ __~_i nvestigation.

A Radiological Classification! ' Maximum Counts Observed*:

Shipped as JX)I Haaous C Material? If yes, contact Waste Hazard Class Shipped:

Manager or ESH Manager. /N#: /

PM (or PMA) review of Hazard classification: Initials r, P Page 16 of 105 a I ýI

Health Physics Procedure GPP-GGGR-R5 104-003 -Attachment B-CY- 001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 i860-267-2556

-Project Name: Haddam Neck Decommissioning

'Contact Name & Phone:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: Z 30 D.[114 D. [] 7 D.

Samples Shipped Via:

0 Fed Ex E uPs

[] Hand M Other Bill of Lading #

"Health Pbys~s, Pr~edure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major Cqnu!qjvc Yankee Atomic Power Company

' " njun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: H-laddam Neck Decommissic Contact Name & Phone:

Jack McCarthy 860-267-2556 Ext. 3024 u

Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:Z30D. [] 14 D M7 D.

Samples Shipped Via:

[ Fed Ex El UPS El Hand Ml Other Bill of Lading #

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O01 Figure 1. Samplc Check-in List c- ,

Date/Time Received: ,,. /,'. 0 G 6I SDG#: IA6 R O -

Work Order Number: /-,*32 1 Shipping Container ID: -_71+i Z- 8-32. Chain of Custody # ~ooo - 60 S.7 -

1. Custody Seals on shipping container intact? Yes No ]
2. Custody Seals dated and signed? Yes No []
3. Chain-of-Custody record present? Yes No [J
4. Cooler temperature
5. Vermiculite/packing materials is: Wet J$ Dry []
6. Number of samples in shipping container:
7. Sample holding times exceeded? Yes [I No
8. Samples have:

. tape hazard labels

  • custody seals __._appropriate sample labels
9. Samples are:

_ in good condition _4 leaking broken have air bubbles

10. Were any anomalies identified in sample receipt? Yes, No []
11. Description of anomalies (include sample numbers):

Sample Custodiar/Laboratory: A- Date: ~*~.e 0, d 9'..e v-Telephoned to: On By .

Page 45 of 56 Page 19 of 105

Connecticut Yankee Statement of Work for Analytical Lab Services CY-isC-SOW-O0 Figure 1. Sample Check-in List.

Date/Time Received: ( oq "

SDG#: . 1.&.O -

__ _ __ _

Work Order Num benr :__ _(_a_

Shipping CainerlID:. Chain of Custody# 3*pO3

- 1. CustodySeals onshipping container intact? Yes [ ] No

2. Custody Seals dated and signed? Yes' [ ] No J
3. Chain-of-Custody record present? Yes No0 [1
4. Coolef lmperature* _
s. Velite/packing materials is: Wet w Dry t',yI 6J . .iNumberof samples in shipping container: "_

_-_"_ -__-

7. Sample holding times exceeded? Yes No

.8.. Samples have:'

2 tpl ea

-h az ad la be ls

.2mgody Seals -. appropriate Sample labels

9. Samples ar:

-M good condition ickn

  • bkc .... ave air bubbles
0. Were any aunoaliesidentifiedin sample receptYs[JNo1 psrtino nmlc(inClude sarinple numer): CQIOL S4ample. C .stodIn/Laboratory. . _-

Telephoned to:_ _

_______________

_

Page 20 of 105

4~

h)h- 4V 4~~

SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM DIM 112 C)o 3j -ACJ+( rV

-Iq* c 3gq:5 cas ~oo V2,so Ni5c -61v had ox_ c _ _ _ __ _ _ _ _

bU-5f e- -5CLry)i'LeA .

F G~ v- _ __ __ __ __ __ _

Page 21 of 105 I 'II

0 SAMPLE RECEIPT & REVIEW FORM a

PM use onrly Client: C4./ CL fr. " ,, SDG/ARCOC/Work Order: / (. o3 7..-

Date Received: , . ,PM(A) Review (ensure non-conforming items are resolved prior to signing):

Veccived By: /7 1 ,Ih '.j _ _ _ _ _ _ __ _ _ _ _ _

Sample Receipt Criteria Z Comments/Quafiriers (Required for Non-Conforming Items) 1 Shipping containers received intact Circle Applicable: seals broken damaged container leaking container other (descrnbe) 1and sealed?

Samples requiring cold Cicle Coolant # ice bag blue ice dry ice none other describe) 2 preservation within (4 + /- 2 C)?

Record preservation method.

Chain of custody documents 3included with shipment? Y 4 Sample containers intact and Circle Applicable: seals broken damaged container lqtaiip other (describe) sealed? - <Wli 2/s (a - Qo0a0 o j - 1p 5 Samples requiring chemical Saple W's. consiven affected and observed pH preservation at proper pH?

6 JVOA vials free of headspace Sawple ID's and containers affected:

((defined as < 6mm bubble)? ... . .. .

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) __

Samples received within holding Id's and tests 2afected:

8 time?

Sample ID's on COC match ID's i ID's ard comnine" affected:

on bottles?

10 Date & time on COC match date San* ID'S affect:

& time on bottles?

1 Number of containers received Sarpl ID's aftected:

match number indicated on COC? _

12 COC form is properly signed in 1relinquished/received sections? .d A-to- r , ,d.A A7 k4 Al Air Bill ,Tracking #'s, &

Additional Comments RAD Receipt________

ected..Hazrd Info tIf > x2 area background is observed on samples identified as .on-

  • r,. :-: -m ' _Pl _a .n*,,regulated/non.-radioactive, contact the Radiaon Safttyngroup for further

. ... "_______.

_____ _______ _ [ uinvest tion.

SRadeoogieal Classification? - Maximum Counts Ob. ,.cd < c.

CB Rp,1,egulated?.

stuppe as Ur H7azardlous CMaterial? If-yes, contact Waste ardlmW e-Manager or ESH Manager.

r/*P] h-1ijw of Hazard classification:nials U

SAMPLE RECEIPT & REVIEW FORM PhM use only Cflent: Van kj b ~SDGIARCOC/Work Order: /6. Z 91 7, Da'te Received: týL 14!() PM(A) Review (esurre nom-coafornuItiU ft re resolved pdio to sipalug):

-Received By: (21r *jv CC* I __....

Sample Receipt Criteria CommentsiQtillrie-s (Required for Non-Conforming Items)

Shipping containers received intact Circle Applicable. seals broken damaged container leaking cornainer other (describe) and sealed? ,_ _ _ __ ___,__

Circle Coolant I ice bags blue ice dry ice other describe)

Samples requiring cold 2 preservation within (4 +/- 2 C)?

... ....

Record preservation method.

Chain of custody documents .. Co C) (S Cxx C> V Ur

.,

included with shipet *

._.mnT*

Sample containers intact and ircie able seats hi damagedconainer leaking contaner (descri sealed? O4c~5v"lleu_ O 'Ji i Samples requiring chemical aple IDa. conainers affecied and observed pH:

preservation at proper pH? .. .. . ....

VOA vials free of headspace Sample ID's and containers affected:

(defined as < 6mm bubble)? ,,_._........

Are Encore containers present? ,,

7 (If yes, immediately deliver to VOA laboratory),,

Samples received within holding Id's and em affected:

time? .....

Sample ID's on COC match ID's Sample iD'S and conie affected:

on bottles?

Date & time on COC match date Sample ID's affected:

& time on bottles?

Number of containers received a ID'3 affected:

match number indicated on COC? 1_

COC form is properly signed in no, Cb'.Ls "L, vYL_ "%Ll 3ikp Ct 1relin uised/received sections? 0 %1 T., :i Ise- CEf ,'Y") U . ,f t--

Air Bill ,Tracking #s, &

Additional Comments V TU RSORAD Receipt#

S Hn *If > x2 area background is observed on samples identified as "non-Suspted Hazard Information "F regulatedlnon-radioactive-" contact the Radiation Safety group for further e

MG investigation.

A Radiological Classification? V/ Maximum Counts Observed*: q ,

B lPCB Regulated? o jShipped as DUV1 Hazardous McMaterial? If yes, contact Waste t Hazard Class Shipped:

JManager or ESH Manager. . UN-PM (or PMA) review of Hazard classification: Initials Date: ., -

Fage2_3 f 10 O"

'1!

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Contact Name & Phone:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) 7 7 General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: N 30 D. [] 14 D. n 7 D.

Samples Shipped Via:

E Fed Ex EL- Harnd

[] UPS El Other Bill of Lading #

7qA'7 ?/9S 413-S

Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-001 Figure 1. Sample Check-in List.

Date/Time Received:

SDG#:

Work Order Number: \X 9 2- A ",.

Shipping Cdctainer ID, -!A - ,%"4'ý 5 7)t o6 Chain of Custody # 06b3,-0C / eOOAt

1. Custody Seals onishipping container intact? Yes ,No[]
2. Custody Seals dated and signed? Yes e4No [].
3. Chain-of-Custody ecord present? Yes SINo []
4. Cooler temperature q
5. Vermiculite/packing materials is: Wet WDry ]

6.' Number of samples in shipping container.: _ _ _ _"

7. Sample holding times exceeded? Yes [ ] No
8. Samples have:*

ttape _" hazard labels

." Z* custody seals -appropriate sample labels

9. Samples ar".:.

ingood condition -/--leaking(gst. .. )

.broken have air bubbles

10. Were any anomalies identified in sample receipt? Yes [INo L'

.I. Description of anomalies. (include sample numbers):

Sample - .ustodiannLaboratoyD Telephoned to:.nB____________

POn 25Byf

  • .Page 25 of 105 . ,- .

.I. Il

9 SAMPLE RECEIPT & REVIEW FORM 01 PM use only jClient: &[ 6 ,SDGIARCOCIWork Order: IG 2-(86 lDate Received:

,Rcie yPM(A)

By:

Review (ensure non-coaFormipg items are resolved prior to signing):

I Sample Receipt Criteria Z Comments/Qualifiers (Required for Non-Conforming Items)

Circle Applicable: seals broken damaged container leaking container other (describe)

Shipping containers received intact a sealed?

ice bags blue ice dry ice none other deseribe)

Samp requiring cold Circle Coolant #

2 preservati within (4 +/- 2 C)?

Record preserv' n method.

Chain of custody d nts 3.

included with shipment?

SSample containers intact and Circle Applicable: seals broken damaged container leaking container other (describe)

,sealed?

Samples requiring chemical Sampl ID's. containers affected and observed pH

preservation at proper pH?

6 VOA vials free of headspace Sample ID's and containers affected:

- (defined as < 6mm bubble)?

Are Encore containers present?

_7 (If yes, immediately deliver to VOA laboratory) 6~

8 Samples received within holding Id's and tests affected:

time?

9 Sample ID's on COC match ID's Sample ID's and containers affected:

on bottles?

Date & time on COC match date Sample ID's affected:

- & time on bottles?

Number of containers received Sample ID's affected:

match number indicated on COC?

COC form is properly signed in 12 relinquished/received sections?

F1( i q g cf 1q5- 4 ' b2f. - /7 o--

14 Air Bill ,Tracking #'s, &

Additional Comments - /PC,'

(*>t).

,a P0 - RSO RAD Receipt #

Suspected Hazard Information Sn e"0r U

  • If > x2 area background is observed on samples identified as "non-regulated/non-radioactive". contact the Radiation Safety group for further cc investigation.

PCB1Ra gilate? Maximum Counts Observed*:

~ P' Reglate?0, Shipped as D01 Hazardous Commients; CMaterial? If yes, contact Waste C Hazard Class Shipped:

-Manager or ESH Manager. UN#:

PM (or PMA) review of Hazard classification:

-a~0, *. o1*

Initials Date: 7t 77 iFavc; /-U 01 IV) U

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company .. " .

362 Injun Hollow Road, East Hampton, CT 06424

'860-267-2556 ______.-._--_. ___-__________ ______"_. ., ...

Project Name: Haddam Neck Decommissioning Analyses Requested -,

ý2ontact Name & Phone: - 4 #i . , 4 JackMcCarthy 860-267-2556 Ext. 3024 '

Analytical Lab (Name, City, State) '" '" :

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 (J 843 556 8171. Attn. Cheryl Jones U). .

Priority: [ 30 D. [ 14 D.-] 7 D. Container . .

_________________ _______ _______Sample Size-Media Type &Type ,

Sample Designation Date Time Code Code Code Comment, Preservation 9106-0006-004F 4/28/06 12:46 SE C BP X x Transferred from COC 2006-00317 9106-0006-005F 4/28/06 13:03 SE C BP X X Transferred from COC 2006-00317 9106-0006-006F 4/28/06 13:22 SE C BP X x Transferred from COC 2006-00317 9106-0006-007F 4/28/06 13:41 SE C BP X - -- Transferred from COC 2006-00317 9106-0006-007FS 4/28/06 13:41 SE C BP X x Transferred from COC 2006-00317 9106-0006-012F. 5/01/06 13:40 SE C BP X X Transferred from COC 2006-00317 9106-0006-017F. 5/01/06 14:03 SE C BP X x Transferred from COC 2006-00317 NOTES: PO #: 002332 MSR #: 06- cýT"1 SSWP# NA [A M I . n Non Sample s Shipped Via:

_' Fed Ex L] ups El Hand 1)Relinquished By DatefTime 2) Received By ate/Time L_,. [U other

3) Relinquished By Date/Time 4) Received By ate/Time Bill of Lading #
  • Connecticut Yankee Statement of Work for Analytical Lab Services . CY-ISC-SOW-901 Figure 1. Sample Check-in List.

Date/Time Received: J @OTZ()* 7 SDG#:

Work OrderaNumber ___._1_ __-

Shipping CdhtainerID: 'QE* c..t ,Th*t ChainofCustody# Steej'f-o s I. Custody Seals.oishpping container intact? ... -Yes ( NokJ:

2. Custody Seals dated and signed?

Yes [] No

3. Chain-of-Custody recordpresent?

Yes W)N0 [ ]

4. Cooler temperature C-.>
5. Vermiculite/packing materials is:

Wet J) Dry , "

6: Numb"rofsranWesin'shippingcon-ain,,.. c "..

7. Sample holding tiMes exceeded?

Yes[]No

8. Sample have--

.!~..ape ....- hazard labels

-custody seals appropriate sample labels

9. Samples are:

good co,,ditionl broken -: "j have air bubbles

10. Were any anomalies identified in salple reipt?

Yes [] No *)

IL. -Descriptjon of anomalies (include sample numbers):,"

Sample Custodian/LAboratory. 2 > 4Jat: /j~

Telephoned to:___________________

Page28of 105

- 11rR ° SAMPLE RECEIPT & REVIEW FORM ON_,ToRt P* weM only Chient:

Date Received:

Received By: C t1Q-evj fl

__

JnriSDG/ARCOC/Work I

PM(A) Review(nuenncnomn Order: /~~16M!, /6 Z765-0 tm ame resolved prior to sigaiag): J sample Receipt Criteria

  • z I Comments/Qualirlers (Required for Non-Coaforming Items)

I Shipping containers received intact Circe Applicable: seats broken damaged cotamier leakiag container odher (descrbe) and sealed ? - C # bbd=3 Samples requiring cold/r- Coolant N iebags blue ice dry ice other 2 preservation within (4 +/- 2 C)?

Record preservation method .... *_____

_ ..,

,3 Chain of custody documents / C.SOU S ox L \V LA included with shipment? I 4 lSample containers intact ad QixcApp na btbI damag/d cornsaer lcakntiguiner ýoda (d_ ibe)*

5 Samples requiring chemical Sp ID's. coinr affce a obsmed pH: ab .

Preservation at proper pH?

6 VOA vials free of headspace Sample IDs sad conainers affected:

(defined as < 6mrnm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to V VOA laboratory) ......

Id's and tests affected:

8 Samples received within holding lime? v e_

9 Sample ID's on COC match ID's Siaile ID's andccoaines affected:

on bottles? I Date & time on COC match date Sattiple ID*affected:

& time on bottles?_____________________________

Number of containers received S/i ID's rm:

match number indicated on COC?

CbC cx.-, v Li YA, licl 12COC form is properly signed in relinquished/received sections?

y M________"I,___U__________1___VU__

4 Air Bill ,Tracking #'s, & SU C(+/-lY)t.L A,- -

Additional Comments V RSO RAD ReceiptI_ ....

(--as *Jf > x2 area background is observed on samples identified as -non-SuspectedHazardInformation rguatd/non-radioactivel, contact the Radiation Safely group for further

, F. investigation.

AIRadological Classification? MIMaximum Counts Obseed*: 4 ,f) 1PCD Regulated? Commentse:

Shipped as LD)01 Hazardous Hi Material? If yes, contact Waste Hazard Class Shipped:

Manager or ESH Manager. UN#:

PM (or PMA) review of Hazard classification: initials Date: -

r'age /Y of1 U._ a

,11

-1,1itl

SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM Fid F, -r--ft- CooCw ______________-

La 1055 a ýw' - o*_0 (0 (50) i*>~

5 bm-slud UaA4 -.

(CG~_!*

e h tnavdF, hcooa

,tamD.-ui*"

_

"

_ _ ___

Page 30 of 105

'1 T.R1!

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003 -Attachment B-CY-0O I Major Chain of Custody Form N.20-06 (5 Connecticut Yankee Atomic Power Company No. 2006-00367 362 Injun Hollow Road, East Hampton, CT 06424 0 860-267-2556 3-7...... .

Project Name: Haddam Neck Decommissioning - - Analyses Requested Lab Use Only 0

(A Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 , o 843 556 817 1. Atta. Cheryl Jones * * * .

Priority: Z 30 D.[] 14 D. ] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0008-OO1F 5/05/06 11:13 SE C BP x x x . Transferred from COC # 2006-00324 9106-0008-003F 5/5/06 13:35 SE C BP X xX " Transferred from COC # 2006-00325 9106-0008-004F 5/5/06 13:51 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-005F 5/5/06 14:17 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-006F 5/5/06 14:36 SE C BP X" x - Transferred from COC # 2006-00325 9106-0008-006FS 5/5/06 14:36 SE C BP X X x Transferred from COC # 2006-00325 9106-0008-007F 5/5/06 15:03 SE C BP x Transferred from COC # 2006-00325 9106-0008-002F 5/5/06 13:10 SE C BP x x x Transferred from COC # 2006-00325 NOTES: PO #: 002332 MSR#: 06-0-K{3 SSWPfNA M LTP QA E Radwaste QA El Non QA Samaples Shipped Via: Internal Container Fed Ex Temp.: - Deg. C E

E lUPS H

Rand Custody Sealed?

1 I,10 YO NO

1) elinqm'sh e "1-'I~at iv de Custody Seal Intact?

] Other

3) kinmquished By k,0 Date/Time 4) R'eeive* y v \X I b~ate/Time B YO NO i 11of Lading #
Z-t 5155 11/92.-

gq

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00366 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & %one: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road, Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones W r .

Priority: N 30 D. " 14 D. E) 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID j 9106-0008-008F 5/08/06 08:01 SE C BP X X X Transferrmd from COC # 2006-00327 0 9106-0008-009F 5/08/06 08:32 SE C BP X X X Transferred from COC # 2006-00327 oil 9106-0008-01OF 5/08/06 09:09 SE C BP X X X Transferred from COC # 2006-00327 01* 9106-0008-01OFS 5/08/06 09:09 SE C BP x x x Transferred from COC # 2006-00327

)'A 9106-0008-01IF 5/08/06 09:30 SE C BP x x x Transferred from COC'#2006-00327

)1 9106-0008-012F 5/08/06 09:53 SE C BP x Transferred from COC #2006-00327 9106-0008-013F 5/08/06 10:16 SE C BP x x x Transferred from COC i 2006-00327 9106-0008-014F 5/08/06 10:47 SE C BP x x x Transferred from COC #2006-00327 NOTES: PO #: 002332 MSR #: 06-61q3 SSWP# NA Z LTP QA [I Radwaste QA El Non QA Samples Shipped Via: Internal Container 0 Fed Ex Temp.: 2-J Deg. C 0I UPS

[] Hand Custody Sealed?

Y 0 N)'

1) Relinquished By Date/Time 2) Received By Date/Time Custody Seal Intact?

r ei [] Other

3) Relinquished By Date/Time 4) Received By Date/Time Y50 NO Bill of Lading #

Connecticut Yankee A63714Z Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Cheek-in List.

Date/Time Received: AQbhUI('M\eJ SDG#:

Work Order Number:____

Shipping Cdotainer ID:. *- I Chain of Custody 1# 00ý - 0 0

1. Custody Seals. on"shipping container intact? .. -Yes [TNo [ ]
2. Custody Seals dated and signed? Yes[ ] No [II.
3. Chain-of-Custody record present? Yes [-4.0o [ ]
4. Cooler temperature . 7
5. Vermiculite/packing materials is: Wet [ Dry 't,] A/A 6.' Number of samples in shipping container: .___"_'____ "_"______
7. Sample holding times exceeded? Yes [ No
10. Were any anomalies identified in sample receipt? Yes'[] No 11....Description of anomalies. (include sample numbers): _

Telephoned to:_________ ______ By -

on_____ __________

Page 33 of 105

ENGZ 0

SAMPLE RECEIPT & REVIEW FORM PM e omly Best: SDG/ARCOCPWark Order:

[Date Received: A0 , F( ev (u*sure nos.cafm*g Itemwreisned prier to nlag):

Received By~ (KJ __________________

Sample Receipt Criteria CommeunsIQuallfiers (Required for Non-Conforming Items)

C/Alweip k e seals: sc ab , , e com ume damma ,.er(d eakigcoeamf,* - scru-c)

Shipping containers received intact and sealed? I =4 Ckk Cooln leebags ble i dry ice I Samples requiring cold 2 preservation within (4 +/- 2 Q?

R ecord p rese rvation method . ..

_._'____ ....

Chain of custody documents included with shipment?

Sample containers intact and CJkAm*k eats k dmadcoine k o.f e *(desctc) sealed?

Saniples requiring chermical npk D'MP. comalam affected and observed pH:

Dreseration at proper PH?

sa pe sD', ta OF-,

  • VOA vials free of headspace (defined as < 6umm bubble)?_/

Are Encore containers present?

7 (If yes, Inuediately deliver to VOA laboratory)

Id's and am affected:

Samples received within holding time?

9 le ID's on COC match ID's /eID'S Md comiafffected:

onbottles?

on COC match date ID'Saffecid:

Da1 & [t

& time on bottles?

Number of containers received /awk ID'S affwted:

match number indicated on COC?

12COC form is properly signed in relinquished/received sections?

Air Bil ,Tracking #'s, &

14 ki ICommnents l q . .

i: .-----

Vu LORAD 0 Remo "#"

Suspeed Hazard Information ii Did If > x2 area backgound is observed On samoples idezitill as non.

aie rm i n-eigation.

radioctive', contact the Radiation Safety group for further

..

L I

j'RI A l'maoogical "amuncaotjon  : Counts Observed*:

-

T a ar ous- Clas Shipped:

u pe asIf D IMuAM

] BTiMatenPtrial?. yes, contact Waste ]NI:

IManager or ESH Manager.

II PM (or PMA) review of Ha-nrd classifcaion:,

LNAm S .5,L'/.~ýOla Date:

Page 34 of 105

SAMLERECEIPT & REVIEW FORM v *4)ORl** ,"l Uen Client:-an k.. .. DGARCOCIWork Order:7 Date Received: 3L'* kv PM(A) Review (ensure non-conronnlng items are resolved prior to signing):

Received By: C ,olti. ¢J7- I '

Sample Receipt Criteria Z Z CommentslQualiflers (Required for Non-Conforinng Items) other (describe)

Circle Applicable: seals broken damaged container leaking container Shipping containers received intact and sealed? __

Samples requiring cold Circle Coolant # ice bags blue ice dry ice i5 ow describ 2 preservation within (4 +/- 2 C)?

- Record preservation method. ___ ___

Chain of custody documents 3included with shipment? .___.--_._

4 Sample containers intact and Cire Applicable: seals broken damaged container leaking container oece (describe) sealed?

_

Samples requiring chemical Sample ID's. containers affected and observed pH:

preservation at proper pH? _

6 VOA vials free of headspace Sample ID's and containers affected:

(defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to l r VOA laboratory) 8i1eSamples received within holding "d'sandmaffected:

8 time? _____________________________

9 Sample ID's on COC march ID's Sample ID's and containers affected:

9on bottles?

10 Date & time on COC match date Sample ID's affected:

& lime on bottles? __________________________

Number of containers received -lSample ID's affected:

match number indicated on COC? I COC form is properly signed in 4 w ,,,/ w".'q4l/*IA d 2 relinquished/received sections?

14 Air Bill ,Tracking #s, & , * ( I 5 .

Additional Comments lvl Is,' RSO RAD Receipt #

l.~l S*lf > x2 area background is observed on samples identified as "non-Suspected Hazard Information I~I

[A jkadiological Classification?

KJ nP F 5,

VI regulated/non-radioactive', contact the Radiation Safety group for further EEivestigation.

red*: 00 frpm PCB Regulated? (.ornments:

Shipped as DOT Hazardous lazard Class Shippe-d:

Material? If yes, contact Waste IN#:

Manager or ESH Manager.

PM (or PMA) review of Hazard classification: Initials 0e./ Date:

9-Page 35 of 105

J(0 a1r/

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:- z Ibt) (t. O3zb SDG#:

Work Order Number:

Shipping Container ID: -19 ZI 5 i I -t_"7 Chain of Custody# _, T_1p " La-.C

i. Custody Seals on shipping container intact?.- Yes o
2. Custody Seals dated and signed? Yes L,4-0o [ ]-

S3. Chai;k-of-Custody record present? Yes L.1*o [ ]

4. Cooler temperature
5. Vermiculite/packing materials is: Wet VrDry [ ]

& Number of samples in shipping container: (i 'La'"Ihk1-

7. Sample holding times exceeded? Yes-[] No
8. Samples have:

tape hazard labels

.custody seals ____appropriate sample labels

9. Samples are..

it/in good condition leaking

- obrken .have r__ air bubbles

10. Were any anomalies identified in sample receipt? Yes [] No [.I--
11. Description of anomalies (include sample numbers):

Sample Custodian/Laboratory: t '/ i --- .... Date:______ ____

Telephoned to: - On By Page 36 of 105

OPP-GGGR-R5104-003 -Attachment B-CY-00 I Major Health Physics Procedure

/_Ijg-a-1 ,J.

Hh sP dG G 10 t m B0*

Chain of Custody Form No. 2006-003 80 Cs Connecticut Yankee Atomic Power Company

-1 362 Injun Hollow Road, East Hampton, CT 06424 0 860-267-2556 0

Project Name: Haddam Neck Decommissioning Analyses Requested LabiUs Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories <

2040 Savage Road. Charleston SC. 29407 C <

843 556 8171. Attn. Cheryl Jones En z Priority: Z 30 D. [] 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0009-016F 5/15/06 13:28 SE C BP X - Transferred from COC 2006-00352 9106-0009-016FS 5/15/06 13:28 SE C BP X X " Transferred from COC 2006-00352 A 9106-0009-017F 5/15/06 14:03 SE C BP x x Transferred from COC 2006-00352 9106-0009-01 IF 5/15/06 08:05 SE C BP x Transferred from COC 2006-00351 9106-0009-013F 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 9106-0009-013FS 5/15/06 08:35 SE C BP X X Transferred from COG 2006-00351 9106-0009-014F OVA? 5/15/06 08:59 SE C BP x Transferred from COC 2006-00351 9106-0009-015F 5/15/06 09:36 SE C BP x x Transferred from COC 2006-00351 910-009-05F /1506 9:36 S C_____ BP X Tanfere rmC 20-05 NOTES: PO #: 002332 MSR #: 06-O/9' SSWP# NA SLTP QA F] Radwaste QA E] Non QA Samples Shipped Via: Internal Container

[ Fed Ex Temp.: __ Deg. C 0 Hand Custody Sealed?

YO NI]

1) Relinquisd By Custody Seal Intact?

Date/Time 2)=yecv *y Date/Time Rni evcy-t El Other

3) Relinquished By Date/Time 4) Rdelevell By Date/Tirne Y ['1 N ]-

Bill of Lading #

_ýq21-z/.? /Y 2AtF

Health Physics Procedure l(o0~;~4'~

- I -

I GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00381 C

D860-267-2556 362 Injun Hollow Road, East Hampton, CT 06424 U

Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones n z Priority: 30 D. [] 14 D. [17 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0009-OOIF 5/11/06 13:22 SE C BP X X Transferrod from COC 2006-00347

) 9106-0009-002F 5/11/06 13:46 SE C BP x x Transferred from COC 2006-00347 1 9106-0009-003F 5/11/06 14:06 SE C BP X X Transferred from COC 2006-00347 a ( 9106-0009-004F 5/11/06 5/11/06 14:30 14:55 SE SE C

C BP BP X

X X

X Transferred from COC 2006-00347 Transferred from COC 2006-00347

'7IA 9106-0009-005F of?,- 9106-0009-007F 5/12/06 07:44 SE C BP X X Transferred from COC 2006-00348 5/12/06 08:16 SE C BP X x Transferred from COC 2006-00348 0( 9106-0009-008F of4' 9106-0009-009F 5/12/06 08:35 SE C BP BP X

X X

X Transferred from COC 2006-00348 Transferred from COC 2006-00348

{ 9106-0009-01OF 5/12/06 09:07 SE C NOTES: PO #: 002332 MSR#: 06- SSWP# NA Z LTP QA El Radwaste QA El Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: _ Deg. C El Hand Custody Sealed?

YO NO

1) Relinquished By Date/Time 2) Rec Date/Time Custody Seal Intact?

El Other

3) Relinquished By Date/Time 4) Received t By Date/Time Y0 ND Bill of Lading #

4tC?11 N*/3" ZYTT

TVo U"I Connecticut Yankee ýCy-lSC-SOw-o00 Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List Date/Time Received: (b7- 0jW SDG#: Ms 0-4C_)-ý I' 19 0S I Work Order Number:

Shipping Cchtainer ID.'_ /I Chain of Custody # __'__________

1. Custody Seals ori shipping container intact?. -Yes iX No [
2. Custody Seals dated and signed? Yes [ No
3. Chain-of-Custody record present? Yes 14 No t ]
4. Cooler temperature . .'L-
5. Vermiculite/packing materials is: Wet [ J Dry 6- Number of samples in shipping container:
7. Sample holding times exceeded? Yes ( No
10. Were any anomalies identified in sample receipt? Yes I I No
11. .. Description ofanomalies.(include sample numbers):

Sample Custodian/Laboratory: Date: Z- -O IG, Telephoned to: On By_

Page 39 of t05

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00349 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

'Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Z Priority: Z 30 D. [] 14 D. [ 7 D. Container Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID i 9106-0010-OOIF 5/04/06 10:49 SE C BP X X Transferred from COC 2006-00321 51O 9106-0010-002F 5/04/06 11:12 SE C BP X X TransfemrAd from COC 2006-00321 Ot 9106-0010-004F 5/04/06 12:48 SE C BP X x Transferred from COC 2006-00321 0i 9106-0010-006F 5/04/06 13:34 SE C BP X X Transferred from COC 2006-00321 9106-0010-007F 5/04/06 13:21 SE C BP X x Transferred from COC 2006-00321 9106-0010-009F 5/04/06 14:01 SE C BP X X Tramferred from COC 2006-00321 9106-0010-OIOF 5/04/06 14:21 SE C BP X X Transferred from COGC2006-00321 9106-0010-012F 5/04/06 14:44 SE C BP X X Transferred from COC 2006-00321 9106-0010-013F 5/04/06 15:06 SE C BP X Tranlsferred from COC 2006-00321 NOTES: PO #: 002332 MSR#: 06- 0o70 SSWP#NA SLTP QA [I Radwaste QA El Non QA Samples Shipped Via: Intemal Container 0 Fed Ex Temp.: _7Deg. C D UPS

[] Hand CustoddSealed?

Y 0' NO0

1) Relinquish eBy Custody Seal Intact?

Date/Ti e 2) Received y Date/Time El Other

3) Relinquished By DateTime 4) Received By Date/Time Y 0"N 0

Bill of Lading #

3q04-3 113- g;-41

Connecticut Yankee

.CY-ISC-SOW-o0l Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List Date/Time Received: qqr S"/17/I06

__ _ _ _ __ _ _ _ __ _ _ _ _

Work Order Number:

'I 8 Chain of Custody '04# 603V Shipping Cdntainer ID: ]

1. Custody Seals ori shipping container intact?. -Yes.[( No []
2. Custody Seals dated and signed? Yes' [M No [ ].
3. Chain-of-Custo'jy record present? Yes [,Q No []
4. Cooler temperature (7' C
5. Vermiculitefpacking materials is: Wet $, Dry (\]
6. Number of samples in shipping container: q_;
7. Sample holding times exceeded? Yes No P

.8. Samples have:

-tape -hazard labels

.- custody seals - _appropriate sample labels

9. Samples are-

-!---in good condition ... eaking

-broken .have air bubbles

10. Were any anomalies identified in sample receipt? Yes [ ] No j~j 11.. Description of anomalies (include sample numbers):

Sample Custodian/Laboratory: Date- "--O Telephoned to: On 0y " .

Page 41 of 105

  • .EN GI/N SSAMPLE RECEIPT & REVIEW FORM 00

~~1roRVPM uiiese only Client: SDG/ARCOcWork Or Date Received: 5" -0b]PM(A) Review ( ites are resolved prior to signng):

Received By: A-U'1,_,__ __ ___ __ ___ _,

Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items)

Shipping containers received intact Circle Applicable: seals broken damaged container leaking container other (describe)

___

and sealed?

Samples requiring cold Circle Coolant # ice bags blue ice dry ice g other describe) 2 preservation within (4 +/- 2 C)?

Record preservation method.

Chain of custody documents included with shipment?

Circle Applicable: seals broken damaged container leaking container other (describe) 4 Sample containers intact and

.sealed?

Samples requiring chemical Sample ID's. containers affected and observed pH:

preservation at proper pH?

Sample ID's and containers affected:

6 VOA vials free of headspace (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) 8 Samples received within holding I's and tests affected:

time?

9 Sample ID's on COC match ID's Smple ID's and containers affected:

on bottles?

Sample UDs affected:

Date time

& on on COC match date onbottles?

&time Number of containers received Sample ID's affected:

match number indicated on COC?

12 COC form is properly signed in relinquished/received sections?

14 Air Bill ,Tracking #'s, & QiIl Additional Comments 7"7 V RSO RAD Receipt # _____________

j *If > x2 area background is observed on samples identified as "non-Suspected Hazard Information regulated/non-radioactive", contact the Radiation Safety group for further

__ investigation.

A Radiological Classification? V111 Maximum Counts Observed*:

lSnippeda as DUuT azardous r aadCasSipd c Material? If yes, contact Waste Hazard Class Shipped:

InN#:

Manager or ESH Manager. a r PM (,o- PMA) review of Hazard classification: ,Initials t ,Date: ,,f

.0 /

Page 42 of 105

List of current GEL Certifications as of 15 August 2006 r State Certification Alaska UST-062 Arizona AZO068 Arkansas 88-0651 CLIA 42D0904046

-California 01 15 ICA Colorado GenEngLabs

.... . . .Connecticut .. ... .. .

PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E187156 Georgia E87156 (FL/NELAP)

Idaho N/A Illinois 200029 Indiana C-SC-0 I Kansas E-10332 Kentucky 90129 Maryland 270 Massachusetts M-SC012 Michigan 9903 Nevada sci2 New Jersey §C002 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania -A 68-485 South Carolina 10120001/10585001/10120002 Tennessee Texas TX213-2006A U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont .... .. . N/A . . . . ..

Virginia 00151 Washington C223 Page 43 of 105

RADIOLOGICAL ANALYSIS Page 44 of 105

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 168404 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555696 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201153129 Method Blank (MB) 1201153130 168340011(9304-01-005C) Sample Duplicate (DUP) 1201153131 168340011 (9304-01-005C) Matrix Spike (MS) 1201153132 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Page 45 of 105

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 168404003 (9106-0003-004F) was recounted due to high MDA.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Page 46 of 105

Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 557837 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Sample ID Client ID 168404009 9106-0006-005F 168404010 9106-0008-006F 1201158316 Method Blank (MB) 1201158317 168404009(9106-0006-005F) Sample Duplicate (DUP) 1201158318 168404009(9106-0006-005F) Matrix Spike (MS) 1201158319 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168404009 (9106-0006-005F).

QC Information Page 47 of 105

All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555697 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 48 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OOIF 168404015 9106-0010-012F 1201153133 Method Blank (MB) 1201153134 168340011(9304-01-005C) Sample Duplicate (DUP) 1201153135 168340011(9304-01-005C) Matrix Spike (MS) 1201153136 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Page 49 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-I 1-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555698 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 50 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01OF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201153137 Method Blank (MB) 1201153138 168340011(9304-01-005C) Sample Duplicate (DUP) 1201153139 168340011(9304-01-005C) Matrix Spike (MS) 1201153140 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Guality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Page 51 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 556350 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 52 of 105

Sample ID Client ID 168404003 9106-0003-004F 168404004 9106-0003-015F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201154644 Method Blank (MB) 1201154645 168404003(9106-0003-004F) Sample Duplicate (DUP) 1201154646 168404003(9106-0003-004F) Matrix Spike (MS) 1201154647 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Page 53 of 105

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Samples 1201154644 (MB), 1201154645 (9106-0003-004F), 1201154646 (9106-0003-004F),

1201154647 (LCS), 168404003 (9106-0003-004F), 168404004 (9106-0003-015F), 168404012 (9106-0009-002F), 168404013 (9106-0009-017F), 168404014 (9106-0010-001F) and 168404015 (9106-0010-012F) were dried and reweighed due to low matrix spike/laboratory control sample recovery.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 554580 Page 54 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01OF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201150561 Method Blank (MB) 1201150562 168340012(9304-02-003C) Sample Duplicate (DUP) 1201150563 168340012(9304-02-003C) Matrix Spike (MS) 1201150564 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.

Page 55 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555722 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 56 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201153222 Method Blank (MB) 1201153223 168340012(9304-02-003C) Sample Duplicate (DUP) 1201153224 168340012(9304-02-003C) Matrix Spike (MS) 1201153225 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.

Page 57 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555723 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 58 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 1201153226 Method Blank (MB) 1201153227 168340012(9304-02-003C) Sample Duplicate (DUP) 1201153228 168340012(9304-02-003C) Matrix Spike (MS) 1201153229 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Page 59 of 105

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 554582 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201150569 Method Blank (MB) 1201150570 168340011(9304-01-005C) Sample Duplicate (DUP) 1201150571 168340011(9304-01-005C) Matrix Spike (MS) 1201150572 Laboratory Control Sample (LCS)

Page 60 of 105

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 168404010 (9106-0008-006F) was recounted due to high MDA.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Page 61 of 105

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 554583 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201150573 Method Blank (MB) 1201150574 168404003(9106-0003-004F) Sample Duplicate (DUP) 1201150575 168404003(9106-0003-004F) Matrix Spike (MS) 1201150576 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Page 62 of 105

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

Page 63 of 105

The following data validator verified the information presented in this case narrative:

Reviewer/Date: KýJ§6ý ze ý6 Page 64 of 105

SAMPLE DATA

SUMMARY

Page 65 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: 168404 GEL Work Order: 168404 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by Page 66 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Ctertifieate nf Analwivd Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Project: YANKO 1204 Sample ID: 168404001 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 20.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0762 +/-0.102 0.00 +/-0.102 0.0956 pCi/g BXLI 08/11/06 1336 555696 1 Curium-242 U 0.00 +/-0.0995 0.00 +/-0.0995 0.138 pCi/g Curium-243/244 U -0.00853 +/-0.0717 0.0405 +/-0.0717 0.177 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U ().199 +/-0.228 0.181 +/-0.229 0.444 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0. 0341 +/-0.129 0.120 +/-0.129 0.323 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 10.0 +/-6.64 5.08 +/-6.72 10.7 pCi/g BXL1 08/16/06 1220 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.17 +/-6.67 5.28 +/-6.67 11.4 pCi/g DFAl 08/09/06 1128 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0813 +/-0.0797 0.0634 +/-0.0797 0.132 pCi/g ATH2 08/09/06 0324 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 9.90 +/-48.1 32.0 +/-48.1 65.9 pCi/g MXPI 08/12/06 1633 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.02 +/-6.39 5.18 +/-6.40 10.6 pCi/g MXPI 08/11/06 0738 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.139 +/-0.213 0.173 +/-0.213 0.360 pCi/g EGD1 08/11/062027 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300. Am-05-RC Modified DOE EML HASL-300, Pu-I l-RC Modified 2

DOE EML HASL-300, Pu-1 I-RC Modified 3

4 EPA 906.0 Modified Page 67 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Project: YANKO 1204 Sample ID: 168404001 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA EERF C-01 Modified 6 DOE RESL Fe-i, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 80 (15%-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 100 (15°/o- 125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 98 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fc55, Solid-ALL FS 75 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 74 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 68 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-01 IF Proiect: YANK01204 Sample ID: 168404002 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 17.4%

Parameter Qualifier Reesult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U C.120 +/-0.154 0.0683 +1-0.155 0.251 pCi/g BXLI 08/11/06 1336 555696 1 Curium-242 U -0.10146 +/-0.122 0.0692 +/-0.123 0.303 pCi/g Curium-243/244 U -0.10103 +/-0.0861 0.0487 +/-0.0862 0.213 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.'0121 +/-0.125 0.127 +/-0.125 0.344 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.10254 +/-0.0675 0.0381 +/-0.0675 0.167 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.72 +/-7.02 5.56 +/-7.05 11.7 pCi/g BXLI 08/16/06 1237 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -0 '.521 +/-7.03 5.94 +/-7.03 12.8 pCi/g DFAI 08/09/06 1143 554582 4 LiquidScint C14, SolidAllFSS Carbon-14 U 0'.023 +/-0.0828 0.0685 +/-0.0828 0.143 pCi/g ATH2 08/09/06 0426 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 3.93 +/-47.7 31.9 +/-47.7 65.7 pCi/g MXPI 08/12/06 1649 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.52 +/-5.81 4.68 +/-5.81 9.60 pCi/g MXPI 08/11/06 0825 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.173 +/-0.203 0.164 +/-0.203 0.341 pCi/g EGD1 08/11/06 2043 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I 1-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 69 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-01 IF Project: YANKO 1204 Sample ID: 168404002 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 76 (15%-1125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 100 (15°%r- 125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 88 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%/o- 125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria
  • Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 70 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Proiect: YANKO 1204 Sample ID: 168404003 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 25-APR-06 Receive Date: 05-MAY-06 Collector: Client Moisture: 23.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.027 +/-0.117 0.153 +/-0.117 0.488 pCi/g BXLI 08/13/06 0819 555696 1 Curium-242 U 0.112 +/-0.315 0.245 +/-0.315 0.781 pCi/g Curium-243/244 U 0.0217 +/-0.206 0.205 +/-0.206 0.594 pCi/g Alphaspec Pu, Solid-ALL FSS 0.176 Plutonium-238 U 0.061 +/-0.189 +/-0.189 0.449 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0551 +/-0.103 0.0584 +/-0.103 0.215 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 +/-5.73 4.40 +/-5.78 9.25 pCi/g BXLI 08/16/06 1253 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.00343 +/-0.0203 0.0172 +/-0.0203 0.036 pCi/g BXFI 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.603 +/-8.25 6.87 +/-8.25 14.8 pCi/g DFA I 08/09/06 1159 554582 5 Liquid Scint C14, Solid AlFSS Carbon-14 U 0.0937 +/-0.0813 0.0642 +/-0.0813 0.134 pCi/g ATH2 08/09/06 0529 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 7.68 +/-51.2 34.2 +/-51.2 70.4 pCi/g MXPI 08/12/06 1706 555722 7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.74 +/-7.12 6.58 +/-7.13 13.6 pCi/g MXPI 08/11/06 0912 555723 8 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0643 +/-0.198 0.169 +/-0.198 0.351 pCi/g EGD I 08/11/06 2059 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified Page 71 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Project: YANKO 1204 Sample ID: 168404003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 DOE EML HASL-300, Pu-I 1-RC Modified 4 EPA 905.0 Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-l, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 42 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 92 (15°/o-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL F5 113 (25%-6125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 59 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 71 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 83 (25%1.- 125%)

Carrier/Tracer Recovery. Liquid Scint Tc99, Solid-ALL FS 76 (15%/,-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 72 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Project: YANK01204 Sample ID: 168404003 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.

Page 73 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Proiect: YANKO 1204 Sample ID: 168404004 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 25-APR-06 Receive Date: 05-MAY-06 Collector: Client Moisture: 22.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0456 +1-0.155 0.139 +1-0.155 0.387 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0.113 +/-0.181 0.0733 +/-0.182 0.321 pCi/g Curium-243/244 U 0.180 +/-0.239 0.181 +/-0.240 0.472 pCi/g Alphaspec Pu, Solid-ALL FSS +/-0.121 Plutonium-238 U 0.0196 0.118 +/-0.121 0.324 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0326 +/-0.0639 0.00 +/-0.064 0.0884 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.63 +/-6.19 4.86 +/-6.22 10.2 pCi/g BXLI 08/16/06 1309 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.00477 +/-0.0216 0.0179 +/-0.0216 0.0375 pCi/g BXF1 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 1.03 +/-7.06 5.85 +/-7.06 12.6 pCi/g DFAI 08/09/06 1215 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 0.156 +/-0.0912 0.0699 +/-0.0913 0.146 pCi/g ATH2 08/09/06 0632 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -9.99 +/-42.7 28.7 +/-42.7 59.2 pCi/g MXPI 08/12/06 1722 555722 7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.939 +/-10.1 10.3 +/-10.1 21.6 pCi/g MXPI 08/11/06 1001 555723 8 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.237 +/-0.213 0.170 +/-0.213 0.353 pCi/g EGDI 08/11/06 2115 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified Page 74 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Project: YANK01204 Sample ID: 168404004 Client ID: YANKO0I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified 5 EPA 906.0 Modified 6 EPA EERF C-0I Modified 7 DOE RESL Fe-1, Modified 8 DOE RESL Ni-1, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 78 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 94 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 101 (25%-/125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 58 (25%- 125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 75 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 62 (25%-7125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 75 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate. of Anavldw Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Project: YANK01204 Sample ID: 168404004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.

Page 76 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005F Proiect: YANKO 1204 Sample ID: 168404005 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 03-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 15.4%

Parameter Qualifier Riesult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -( 0.036 +/-0.123 0.157 +/-0.123 0.437 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0. 0169 +/-0.033 0.080 +/-0.03 31 0.350 pCi/g Curium-243/244 U -0. 0129 +/-0.227 0.247 +/-0.227 0.619 pCi/g Aiphaspec Pu, Solid-ALL FSS Plutonium-238 U -0. 0217 +/-0.163 0.181 +/-0.163 0.444 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -0. 0708 +/-0.0791 0.128 +/-0.0795 0.337 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 9.52 +/-6.00 4.57 +/-6.07 9.61 pCi/g BXLI 08/16/06 1326 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U ().854 +/-5.88 4.87 +/-5.88 10.5 pCi/g DFAI 08/09/06 1231 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 01.347 +/-0.097 0.0674 +/-0.0972 0.141 pCi/g ATH2 08/09/06 0734 554583 5 Liquid Scint Fe55, Solid-ALL FSS lron-55 U - -1.57 +/-46.0 30.7 +/-46.0 63.2 pCi/g MXP1 08/12/06 1738 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 6.39 +/-7.62 7.40 +/-7.62 15.5 pCi/g MXPI 08/11/06 1017 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0198 +/-0.187 0.156 +/-0.187 0.324 pCi/g EGDI 08/11/06 2131 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-0I Modified Page 77 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005F Project: YANKO 1204 Sample ID: 168404005 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 65 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 95 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 105 (25%/a- 125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 78 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 80 (25%-61259/6)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 80 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 78 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-01 5F Project: YANKO 1204 Sample ID: 168404006 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 03-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 26.5%

Parameter Qualifier RIesult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0. 0823 +/-0.203 0.178 +/-0.203 0.469 pCi/g BXL1 08/11/06 1434 555696 1 Curium-242 U -0. 0154 +/-0.0301 0.0729 +/-0.0302 0.319 pCi/g Curium-243/244 U -0. 0994 +/-0.251 0.300 +/-0.251 0.713 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0. 0466 +/-0.213 0.210 +/-0.213 0.521 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -( 1.142 +/-0.108 0.191 +/-0.109 0.483 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.64 +/-6.53 5.16 +/-6.57 10.8 pCi/g BXLI 08/16/06 1342 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -2.9 +/-7.59 6.60 +/-7.59 14.2 pCi/g DFA I 08/09/06 1247 554582 4 Liquid Scint C14, Solid Al, FSS Carbon-14 U 0.0352 +/-0.0868 0.0713 +/-0.0868 0.149 pCi/g ATH2 08/09/06 0837 554583 5 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 1.88 +/-46.8 31.3 +/-46.8 64.4 pCi/g MXPI 08/12/06 1754 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 3.88 +/-7.46 7.40 +/-7.46 15.5 pCi/g MXPI 08/11/06 1033 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.10894 +/-0.198 0.163 +/-0.198 0.338 pCi/g EGDI 08/11/06 2147 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 79 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-015F Project: YANK01204 Sample ID: 168404006 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 72 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 72 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 94 (25%-I125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 73 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 80 (25%-.125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 78 (15%-125%o)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 80 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-OIOF Project: YANKO 1204 Sample ID: 168404007 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 02-MAY-06 Receive Date: 09-MAY-06 Collector: Client Moisture: 56.2%

Parameter Qualifier Riesult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -( 1.128 +/-0.0939 0.142 +/-0.0942 0.385 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0. 0115 +/-0.128 0.147 +/-0.128 0.450 pCi/g Curium-243/244 U -0. 0333 +/-0.122 0.149 +/-0.122 0.401 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0. 0548 +/-0.169 0.158 +/-0.170 0.403 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0. 0195 +/-0.121 0.117 +/-0.121 0.322 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 10.4 +/-6.89 5.27 +/-6.97 11.1 pCi/g BXLI 08/16/06 1358 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 +/-6.86 5.76 +/-6.86 12.4 pCi/g DFA I 08/09/06 1303 554582 4 Liquid Scint C14, SolidAIlFSS Carbon-14 U 0. 0636 +/-0.0801 0.0644 +/-0.0801 0.135 pCi/g ATH2 08/09/06 1017 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 36.1 +/-44.1 28.7 +/-44.1 59.0 pCi/g MXP1 08/12/06 1811 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.26 +/-10.2 10.0 +/-10.2 20.9 pCi/g MXPI 08/11/06 1049 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U - 0.05 +/-0.199 0.169 +/-0.199 0.351 pCi/g EGD 1 08/11/06 2203 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-0I Modified Page 81 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-011OF Project: YANK01204 Sample ID: 168404007 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 85 (15%-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15°/-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 92 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 (15%-1125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 64 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 77 (15%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 82 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-014F Project: YANKO1204 Sample ID: 168404008 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 02-MAY-06 Receive Date: 09-MAY-06 Collector: Client Moisture: 32.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00591 +/-0.219 0.231 +/-0.219 0.608 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0.04 +/-0.0554 0.134 +/-0.0557 0.494 pCi/g Curium-243/244 U 0.0634 +/-0.261 0.249 +/-0.261 0.646 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0694 +/-0.106 0.160 +/-0.106 0.434 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -0.0287 +/-0.098 0.127 +/-0.0981 0.369 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.68 +/-8.01 6.48 +/-8.02 13.6 pCi/g BXLI 08/16/06 1415 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 6.02 +/-6.38 4.90 +/-6.38 10.6 pCi/g DFAI 08/09/06 1319 554582 4 Liquid Scint C14, SolidAIlFSS Carbon-14 U 0.0892 +/-0.0827 0.0655 +/-0.0827 0.137 pCi/g ATH2 08/09/06 1424 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 19.8 +/-46.3 30.6 +/-46.3 62.9 pCi/g MXPI 08/12/06 1827 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.41 +/-7.91 7.77 +/-7.91 16.2 pCi/g MXPI 08/11/06 1106 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.134 +/-0.192 0.167 +/-0.192 0.346 pCi/g EGD1 08/11/06 2218 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu- 11-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 83 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-014F Project: YANKO 1204 Sample ID: 168404008 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 50 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 61 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 74 (25%-I 25%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 76 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 84 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005F Proiect: YANKO 1204 Sample ID: 168404009 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 16.5%

Parameter Qualifier Re suit Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.( 0851 +/-0.136 0.106 +/-0.136 0.390 pCi/g BXL1 08/16/06 0949 557837 1 Curium-242 U -0.( 0253 +/-0.0495 0.120 +/-0.0496 0.525 pCi/g Curium-243/244 U -0.(0479 +/-0.0542 0.131 +/-0.0545 0.443 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.(0183 +/-0.113 0.110 +/-0.113 0.303 pCi/g BXLI 08/11/06 1633 555697 3 Plutonium-239/240 U 0.0(0122 +/-0.0662 0.0694 +/-0.0662 0.221 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.43 +/-5.83 4.67 +/-5.85 9.82 pCi/g BXLI 08/16/06 1431 555698 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U - 2.02 +/-6.67 5.76 +/-6.67 12.4 pCi/g DFAI 08/09/06 1335 554582 5 Liquid Scint C14, SolidAllFSS Carbon- 14 0.142 +/-0.0798 0.061 +/-0.0799 0.127 pCi/g ATH2 08/09/06 1719 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 12.6 +/-47.6 31.7 +/-47.6 65.3 pCi/g MXPI 08/12/06 1843 555722 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.70 +/-9.56 9.31 +/-9.56 19.5 pCi/g MXPI 08/11/06 1122 555723 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0( 0659 +/-0.185 0.156 +/-0.185 0.323 pCi/g EGD1 08/11/06 2234 554580 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 DOE EML HASL-300, Pu-l 1-RC Modified 5 EPA 906.0 Modified Page 85 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Anaivsis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005F Project: YANKO 1204 Sample ID: 168404009 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 76 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 93 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 105 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15°/-6125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 64 (25%-.125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 81 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 86 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-006F Proiect: YANK01204 Sample ID: 168404010 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 05-MAY-06 Receive Date: 26-MAY-06 Collector: Client Moisture: 34.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U I +/-0.195 0.0758 +/-0.196 0.332 pCi/g BXLI 08/16/06 0949 557837 1 Curium-242 U +/-0.202 0.00 +/-0.203 0.280 pCi/g Curium-243/244 U -0. +/-0.0316 0.0766 +/-0.0317 0.335 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0. +/-0.0711 0.0967 +/-0.0712 0.275 pCi/g BXLI 08/11/06 1633 555697 3 Plutonium-239/240 U 0.0 +/-0.113 0.118 +/-0.113 0.317 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 14.9 +/-6.37 4.64 +/-6.51 9.75 pCi/g BXLI 08/16/06 1447 555698 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 +/-6.06 5.09 +/-6.06 10.7 pCi/g DFAI 08/10/06 2150 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U M.107 +/-0.0846 0.0664 +/-0.0846 0.139 pCi/g ATH2 08/09/06 1822 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 15.1 +/-41.4 27.5 +/-41.4 56.6 pCi/g MXPI 08/12/06 1900 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U ).258 +/-0.225 0.179 +/-0.225 0.373 pCi/g EGDI 08/11/06 2251 554580 " 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 DOE EML HASL-300, Pu-1 I-RC Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-1, Modified Page 87 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-006F Project: YANK01204 Sample ID: 168404010 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 8 DOE EML HASL-300. Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALl 77 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 94 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 103 (25/.-1 25%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%/o-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 71 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 88 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-008F Project: YANKO1204 Sample ID: 168404011 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 08-MAY-06 Receive Date: 26-MAY-06 Collector: Client Moisture: 35.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Ailphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0. +/-0.192 0.152 +/-0.193 0.426 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0. +/-0.142 0.132 +/-0.142 0.446 pCi/g Curium-243/244 U -0. +/-0.202 0.240 +/-0.203 0.603 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0. +/-0.096 0.125 +/-0.096 0.328 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -0. +/-0.114 0.137 +/-0.114 0.353 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 11.5 +/-6.72 5.08 +/-6.80 10.7 pCi/g BXLI 08/16/06 1504 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 +/-5.92 4.97 +/-5.92 10.7 pCi/g DFAI 08/09/06 1407 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U -0. 0238 +/-0.0745 0.0636 +/-0.0745 0.133 pCi/g ATH2 08/09/06 1924 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U - -10.7 +/-40.9 27.5 +/-40.9 56.8 pCi/g MXPI 08/12/06 1916 555722 6 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0. 0956 +/-0.211 0.174 +/-0.211 0.361 pCi/g EGD1 08/11/062307 554580 7 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu-l -RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified 6 DOE RESL Fe-I, Modified Page 89 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-008F Project: YANKO 1204 Sample ID: 168404011 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 7 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 65 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 96 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 76 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 74 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCiMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

U1 Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier

  • QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 90 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Project: YANK01204 Sample ID: 168404012 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 11-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 33%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.00144 +1-0.155 0.166 +/-0.155 0.458 pCi/g BXL1 08/11/06 1434 555696 1 Curium-242 U 0.0192 +/-0.145 0.135 +/-0.145 0.455 pCi/g Curium-243/244 U 0.013 +/-0.268 0.281 +/-0.268 0.687 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00587 +/-0.0493 0.0279 +/-0.0494 0.122 pCi/g BXLI 08/11/06 1632 555697 2 Plutonium-239/240 U 0.0186 +/-0.0492 0.0278 +/-0.0493 0.122 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.6 +/-6.90 5.13 +/-7.01 10.8 pCi/g BXL1 08/16/06 1520 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0151 +/-0.0146 0.0114 +/-0.0146 0.0242 pCi/g BXF1 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.12 +/-8.36 6.70 +/-8.36 14.5 pCi/g DFAI 08/09/06 1422 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.046 +/-0.0755 0.0613 +/-0.0755 0.128 pCi/g ATH2 08/09/06 2027 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 12.9 +/-40.6 26.8 +/-40.6 55.2 pCi/g MXPI 08/12/06 1932 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.078 +/-0.203 0.168 +/-0.203 0.348 pCi/g EGDI 08/11/06 2323 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300. Am-05-RC Modified DOE EML HASL-300, Pu-I11-RC Modified 2

DOE EML HASL-300, Pu-I I-RC Modified 3

4 EPA 905.0 Modified Page 91 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Project: YANK0 1204 Sample ID: 168404012 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 61 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15%- 125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 94 (25°/o- 125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (25°%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 ( 15%- 125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 92 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Project: YANKO 1204 Sample ID: 168404013 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 28.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0755 +/-0.242 0.230 +/-0.243 0.574 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0.0957 +/-0.220 0.171 +/-0.220 0.509 pCi/g Curium-243/244 U -0.073 +/-0.214 0.256 +/-0.214 0.627 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00629 +/-0.0529 0.0299 +/-0.0529 0.131 pCi/g BXLI 08/11/06 1632 555697 2 Plutonium-239/240 U 0.0262 +/-0.0513 0.00 +/-0.0514 0.0709 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.3 +/-6.66 4.95 +/-6.77 10.4 pCi/g BXLI 08/16/06 1536 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0205 +/-0.0151 0.0116 +/-0.0151 0.0246 pCi/g BXFI 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.583 +/-7.98 6.65 +/-7.98 14.4 pCi/g DFAI 08/09/06 1438 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0271 +/-0.0759 0.0625 +/-0.0759 0.131 pCi/g ATH2 08/09/06 2129 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -61.9 +1-150 102 +1-150 210 pCi/g MXPI 08/12/06 1949 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0628 +/-0.200 0.165 +/-0.200 0.343 pCi/g EGD1 08/11/06 2338 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 93 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Project: YANKO 1204 Sample ID: 168404013 Client ID: YANKOOl Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 64 (15/%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 96 (25%- 125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 73 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 94 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-OO1F Proiect: YANKO 1204 Sample ID: 168404014 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 27.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0 +/-0.227 0.238 +/-0.227 0.628 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0. +/-0.167 0.00 +/-0.168 0.231 pCi/g Curium-243/244 U 0. +/-0.242 0.241 +/-0.242 0.634 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U ( +/-0.181 0.143 +/-0.182 0.331 pCi/g BXL1 08/11/06 2250 555697 2 Plutonium-239/240 U -0. +/-0.0865 0.0951 +/-0.0866 0.235 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.0 +/-6.44 4.78 +/-6.54 10.0 pCi/g BXLI 08/16/06 1553 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0. 0128 +/-0.0141 0.0125 +/-0.0141 0.0262 pCi/g BXF1 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U ( 0.548 +/-7.50 6.25 +/-7.50 13.5 pCi/g DFAI 08/09/06 1454 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.'0555 +/-0.0809 0.0655 +/-0.0809 0.137 pCi/g ATH2 08/09/06 2232 554583 6 Liquid Scint Fe55, Solid-ALL FSS lron-55 U - -18.1 +/-47.6 32.3 +/-47.6 66.6 pCi/g MXPI 08/12/06 2005 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U C1.134 +/-0.205 0.167 +/-0.205 0.347 pCi/g EGD1 08/11/06 2354 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 95 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-00IF Project: YANK01204 Sample ID: 168404014 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 50 (15%-125/)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 85 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 99 (25%-6125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25%-6125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 70 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 96 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Project: YANKO 1204 Sample ID: 168404015 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 28.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.110 +/-0.184 0.140 +/-0.184 0.386 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0.0547 +/-0.141 0.192 +/-0.141 0.544 pCi/g Curium-243/244 U -0.126 +/-0.184 0.245 +/-0.185 0.597 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00157 +/-0.126 0.122 +/-0.126 0.291 pCi/g BXLI 08/11/06 2250 555697 2 Plutonium-239/240 U 0.0867 +/-0.0869 0.0406 +/-0.0872 0.128 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 +/-6.16 4.77 +/-6.21 10.0 pCi/g BXLI 08/16/06 1609 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid ALL FSS Strontium-90 U -0.00771 +/-0.0144 0.0124 +/-0.0144 0.0263 pCi/g BXFI 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.896 +/-6.17 5.11 +/-6.17 11.0 pCi/g DFAI 08/09/06 1510 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0162 +/-0.0763 0.0633 +/-0.0763 0.132 pCi/g ATH2 08/09/06 2334 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 23.3 +/-49.3 32.5 +/-49.3 67.0 pCi/g MXPI 08/12/06 2021 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0577 +/-0.206 0.171 +/-0.206 0.354 pCi/g EGDI 08/12/06 0010 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu- 11-RC Modified 4 EPA 905.0 Modified Page 97 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Project: YANK01204 Sample ID: 168404015 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 81 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 99 (25%-I125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 68 (25%-6125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 74 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 98 of 105

I QUALITY CONTROL DATA Page 99 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Renort Date: August 21, 2006 Client: Connecticut Yankee Atomic Power Page 1 of 6 362 Injun Hollow Rd East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder: 168404 Parmname NOM Sample Qual OC Units RPD% REC% Ranee Anlst Date Time Rad Alpha Spec Batch 555696 QC1201153130 168340011 DUP Americium-241 U -0.000522 U 0.0578 pCi/g 204 (0%- 100%) BXLI 08/11/06 14:34 Uncert: +/-0.0385 +/-0.278 TPU: +/-0.0385 +/-0.279 Curium-242 U 0.00 U -0.0405 pCi/g 200 (0%- 100%)

Uncert: +/-0.0756 +/-0.0562 TPU: +/-0.0756 +/-0.0565 Curium-243/244 U -0.0177 U -0.0517 pCi/g 98 (0%- 100%)

Uncert: +/-0.0764 +/-0.257 TPU: +/-0.0765 +/-0.257 QC1201153132 LCS Americium-24 I 12.8 12.8 pCi/g 100 (75%-125%)

Uncert: +/-1.84 TPU: +/-2.70 Curium-242 U -0.0328 pCi/g Uncert: +/-0.0454 TPU: +/-0.0457 Curium-243/244 15.5 14.3 pCi/g 92 (75%-125%)

Uncert: +/-1.94 TPU: +/-2.92 QC1201153129 MB Americium-241 U 0.0471 pCi/g Uncert: +/-0.157 TPU: +/-0.157 Curium-242 U -0.0469 pCi/g Uncert: +/-0.0459 TPU: +/-0.0464 Curium-243/244 U -0.00385 pCi/g Uncert: +/-0.210 TPU: +/-0.210 QC1201153131 168340011 MS Americium-241 13.3 U -0.000522 "12.0 pCi/g 91 (75%-125%)

Uncert: +/-0.0385 +/-1.38 TPU: +/-0.0385 +/-2.08 Curium-242 U 0.00 U 0.0427 pCi/g Uncert: +/-0.0756 +/-0.0837 TPU: +/-0.0756 +/-0.0839 Curium-243/244 16.1 U -0.0177 15.9 pCi/g 99 (75%-125%)

Uncert: +/-0.0764 +/-I.58 TPU: +/-0.0765 +/-2.61 Batch 555697 QC1201153134 168340011 DUP Plutonium-238 U -0.0155 U 0.0237 pCi/g 956 (0%- 100%) BXLI 08/11/06 22:51 Page 100 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 2 of 6 Parmname NOM Sample Oual QC Units RPD% REC% Range AnIst Date Time Rad Alpha Spec Batch 555697 Uncert: +/-0.0215 +/-0.0465 TPU: +/-0.0216 +/-0.0466 Plutonium-239/240 U 0.0414 U -0.0489 pCi/g 2410 (0%- 100%)

Uncert: +/-0.0934 +/-0.124 TPU: +/-0.0935 +/-0.124 QC1201153136 LCS Plutonium-238 U 0.155 pCi/g (75%-125%)

Uncert: +/-0.141 TPU: +/-0.142 Plutonium-239/240 11.8 11.5 pCi/g 98 (75%-125%)

Uncert: +/-0.856 TPU: +/-1.32 QC1201153133 MB Plutonium-238 U 0.0552 pCi/g 08/11/06 22:50 Uncert: +/-0.186 TPU: +/-0.186 Plutonium-239/240 U -0.0978 pCi/g Uncert: +/-0.0892 TPU: +/-0.0899 QC1201153135 168340011 MS Plutonium-238 U -0.0155 U 0.0539 pCi/g (75%-125%) 08/11/06 22:51 Uncert: +/-0.0215 +/-0.112 TPU: +/-0.0216 +/-0.112 Plutonium-239/240 12.3 U 0.0414 10.3 pCi/g 84 (75%-125%)

Uncert: +/-0.0934 +/-0.796 TPU: +/-0.0935 +/-1.19 Batch 555698 QC1201153138 168340011 DUP Plutonium-24 I U 7.28 U 10.1 pCi/g 0 (0% - 100%) BXLI 08/16/06 16:41 Uncert: +/-6.30 +/-6.39 TPU: +/-6.35 +/-6.46 QC1201153140 LCS Plutonium-241 137 145 pCi/g 106 (75%-125%) 08/16/06 17:14 Uncert: +/-12.5 TPU: +/-19.9 QC1201153137 MB Plutonium-241 U 8.57 pCi/g 08/16/06 16:25 Uncert: +/-6.93 TPU: +/-6.98 QC1201153139 168340011 MS Plutonium-241 138 U 7.28 142 pCi/g 103 (75%-125%) 08/16/06 16:58 Uncert: +/-6.30 +/-12.4 TPU: +/-6.35 +/-19.7 Batch 557837 QC1201158317 168404009 DUP Americium-241 U -0.0851 U 0.167 pCi/g 616 (0%- 100%) BXLI 08/16/06 09:49 Uncert: +/-0.136 +/-0.220 TPU: +/-0.136 +/-0.221 Curium-242 U -0.0253 U 0.241 pCi/g 247 (0% - 100%)

Page 101 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 3 of 6 Parmname NOM Samnle Oual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 557837 Uncert: +/-0.0495 +/-0.334 TPU: +/-0.0496 +/-0.335 Curium-243/244 U -0.0479 U 0.0761 pCi/g 879 (0% - 100%)

Uncert: +/-0.0542 +/-0.149 TPU: +/-0.0545 +/-0.149 QC1201158319 LCS Americium-241 24.5 25.4 pCi/g 104 (75%-125%)

Uncert: +/-2.47 TPU: +/-4.16 Curium-242 U 0.0477 pCi/g Uncert: +/-0.127 TPU: +/-0.127 Curium-243/244 29.7 27.0 pCi/g 91 (75%-125%)

Uncert: +/-2.54 TPU: +/-4.38 QC1201158316 MB Americium-241 U 0.234 pCi/g Uncert: +/-0.275 TPU: +/-0.277 Curium-242 U 0.00 pCi/g Uncert: +/-0.152 TPU: +/-0.152 Curium-243/244 U -0.0551 pCi/g Uncert: +/-0.0624 TPU: +/-0.0628 QC1201158318 168404009 MS Americium-241 26.4 U -0.0851 29.1 pCi/g 110 (75%-125%)

Uncert: +/-0.136 +/-2.97 TPU +/-0.136 +/-5.01 Curium-242 U -0.0253 U 0.126 pCi/g Uncert: +/-0.0495 +/-0.247 TPU +/-0.0496 +/-0.248 Curium-243/244 32.4 U -0.0479 31.7 pCi/g 98 (75%-125%)

Uncert: +/-0.0542 +/-3.12 TPU +/-0.0545 +/-5.39 Rad Gas Flow Batch 556350 QC1201154645 168404003 DUP Strontium-90 U -0.00343 U -0.00637 pCi/g 0 (0%- 100%) BXFI 08/14/06 08:33 Uncert: +/-0.0203 +/-0.0152 TPU: +/-0.0203 +/-0.0152 QC1201154647 LCS Strontium-90 1.56 1.30 pCi/g 83 (75%-125%)

Uncert: +/-0.0563 TPU: +/-0.0881 QC1201154644 MB Strontium-90 U 0.0176 pCi/g Uncert: +/-0.018 TPU: +/-0.018 Page 102 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 4 of 6 Parmname NOM Samnle Oual QC Units RPD% REC% Range AnIst Date Time NOM Rad Gas Flow Batch 556350 QC1201154646 168404003 MS Strontium-90 1.58 U -0.00343 1.29 pCi/g 82 (75%-125%)

Uncert: +/-0.0203 +/-0.0535 TPU: +/-0.0203 +/-0.0813 Rad Liquid Scintillation Batch 554580 QC1201150562 168340012 DUP Technetium-99 U 0.0338 U 0.266 pCi/g 0 (0% - 100%) EGDI 08/12/06 00:42 Uncert: +/-0.192 +/-0.226 TPU: +/-0.192 +/-0.226 QCI201150564 LCS Technetium-99 13.1 13.6 pCi/g 103 (75%-125%) 08/12/06 01:14 Uncert: +/-0.496 TPU: +/-0.599 QC1201150561 MB Technetium-99 U 0.0311 pCi/g 08/12/06 00:26 Uncert: +/-0.177 TPU: +/-0.177 QC1201150563 168340012 MS Technetium-99 13.0 U 0.0338 12.0 pCi/g 92 (75%-125%) 08/12/06 00:58 Uncert: +/-0.192 +/-0.523 TPU: +/-0.192 +/-0.602 Batch 554582 QC1201150570 168340011 DUP Tritium U 1.77 U 1.62 pCi/g 0 (0% - 100%) DFA I 08/09/06 15:42 Uncert: +/-8.20 +/-7.47 TPU: +/-8.20 +/-7.47 QC1201150572 LCS Tritium 68.3 76.2 pCi/g 111 (75%-125%) 08/09/06 16:14 Uncert: +/-14.0 TPU: +/-14.1 QCI201150569 MB Tritium U 0.586 pCi/g 08/09/06 15:26 Uncert: +/-8.01 TPU: +/-8.01 QC1201150571 168340011 MS Tritium 61.3 U 1.77 61.8 pCi/g 101 (75%-125%) 08/09/06 15:58 Uncert: +/-8.20 +/-12.2 TPU: +/-8.20 +/-12.3 Batch 554583 QC1201150574 168404003 DUP Carbon-14 U 0.0937 I11 0.0422 pCi/g 0 (0% - 100%) ATH2 08/10/06 01:39 Uncert: +/-0.0813 +/-0.075 TPU: +/-0.0813 +/-0.0751 QC1201150576 LCS Carbon- 14 7.27 7.14 pCi/g 98 (75%-125%) 08/10/06 03:00 Uncert: +/-0.508 TPU: +/-0.520 QC1201150573 MB Page 103 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 5 of 6 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 554583 Carbon- 14 U -0.0315 pCi/g Uncert: +/-0.0776 TPU +/-0.0776 QC1201150575 168404003 MS Carbon- 14 15.1 u 0.0937 13.8 pCi/g 92 (75%-125%) 08/10/06 02:43 Uncert: +/-0.0813 +/-1.00 TPU +/-0.0813 +/-1.03 Batch 555722 QC1201153223 168340012 DUP Iron-55 U -26.5 U 5.83 pCi/g 0 (0% - 100%) vlXP1 08/12/06 20:54 Uncert: +/-65.1 +/-36.9 TPU +/-65.1 +/-36.9 QC1201153225 LCS Iron-55 641 660 pCi/g 103 (75%-125%) 08/12/06 21:27 Uncert: +/-56.2 TPU +/-67.2 QC1201153222 MB Iron-55 U 18.2 pCi/g 08/12/06 20:38 Uncert: +/-39.6 TPU +/-39.6 QC1201153224 168340012 MS Iron-55 717 U -26.5 688 pCi/g 96 (75%-125%) 08/12/06 21:11 Uncert: +/-65.1 +/-60.2 TPU +/-65.1 +/-71.6 Batch 555723 QC1201153227 168340012 DUP Nickel-63 U 3.79 U 6.68 pCi/g 0 (0% - 100%) vlXPI 08/11/06 11:55 Uncert: +/-5.39 +//-7.43 TPU: +/-5.40 +/'-7.43 QC1201153229 LCS Nickel-63 512 479 pCi/g 94 (75%-125%) 08/11/06 12:27 Uncert: +//-22.4 TPU: +/'-27.1 QC1201153226 MB Nickel-63 U 15.7 pCi/g 08/11/06 11:38 Uncert: +/'-9.92 TPU: +/'-9.93 QC1201153228 168340012 MS Nickel-63 530 U 3.79 511 pCi/g 96 (75%-125%) 08/11/06 12:11 Uncert: +/-5.39 +/-23.5 TPU: +/-5.40 +/'-28.7 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported Result is greater than value reported Page 104 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 6 of 6 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

Page 105 of 105

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2b Split Sample Assessment Forms (2 Pages)

Connecticut Yankee Decommissioning Project Health 24265-000-GPR-GGGR-R5124-000 Attachment A Physics Procedure Split Sample Assessment Form Survey 9106 Survey 0009 Survey Unit Discharge Canal Area#: Unit #: Name:

Sample Plan or WPIR#: 2006-0021 SML #: 9106-0009-013 Sample

Description:

Comparison of split samples collected from sample measurement location #13 and analyzec using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9106-0009-013F, thc comparison sample was 9106-0009-013FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)

Cs-137 2.85E-02 1.45E-02 2 N/A 4.62E-02 2.76E-02 1.62 N/A Co-60 0.OOE+00 1.74E-02 0 N/A -2.78E-02 1.52E-02 N/A N/A Ni-63 -3.87E+00 4.53E+00 -1 N/A -9.09E+00 4.46E+00 2.35 N/A K-40 1.44E+01 6.65E-01 22 0.75 1.33 1.86E+01 6.25E-01 1.29 Y Comments/Corrective Actions: In consideration of the Cs-137, Table is provided to show acceptance criteria Co-60 and Ni-63 results, guidance for agreement ranges, used to assess split samples.

obtained from USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination Resolution Agreement Range of acceptability for such rations cannot be made. Since K-40 4 7 0.50 2.00 was found to be present at an acceptable levels of agreement, no 8 15 0.60 1.66 further action is warranted. 16 50 0.75 1.33 51 200 0.80 1.25

> 200 0.85 1.18 Performed By: Date: Reviewed By: Date:

.tý &J yzVV'a/(-ýOz ý ////1ID 6-WPIR - Work Plan and Inspection Record SML - Sample Measurement Location designation Page I of I

Connecticut Yankee Decommissioning Project Health 24265-000-GPR-GGGR-R5124-000 Attachment A Physics Procedure Split Sample Assessment Form Survey Area Survey 0009 Survey Discharge Canal

  1. 9106 Unit #: UnitName:

Sample Plan or WPIR#: 2006-021 SML #: 9106-0009-016 Sample

Description:

Comparison of split samples collected from sample measurement location #16 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9106-0009-016F the comparison sample was 9106-0009-016FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)

Cs-137 1.70E-01 2.17E-02 8 0.6 1.66 2.31E-01 2.08E-02 1.36 Y Co-60 2.39E-01 2.33E-02 10 0.6- 1.66 2.77E-01 3.05E-02 1.16 Y Ni-63 -6.30E+00 4.32E+00 -1 N/A -1.18E+01 4'.58E+00 1.87 N/A K-40 1.44E+01 6.65E-01 22 0.75 1.33 1.30E+01 6.25E-01 0.90 Y Comments/Corrective Actions: In consideration of the Ni-63 Table is provided to show acceptance criteria results, guidance for agreement ranges, obtained from USNRC used to assess split samples.

Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such Resolution Agreement Range rations cannot be made. Since Cs-137, Co-60 and K-40 were 4 7 0.50 2.00 found to be present at an acceptable levels of agreement, no 8 15 0.60 1.66 further action is warranted. 16 50 0.75 1.33 51 200 0.80 1.25

> 200 0.85 1.18 Performed By: Date: Reviewed By:

10o-31 -04 a

WPIR - Work Plan and Inspection Record SML - Sample Measurement Location designation Page I of I

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2c Preliminary Data Form (1 Page)

Health Physics Procedure GPP-GGGR-R5121-001 Attachment B, Rev. CY-001 MAJOR Health Physics Procedure GPP-GGGR-R5 121-001 Attachment B, Rev. CY-00 1 MAJOR Preliminary Data Review Form - Samples for the Sign Test Survey Unit: 9106- 0009 Survey Unit Name: Discharge Canal Classification: 2 Survey Media: Soil Type of Survey: Final Status Survey Type of Measurement: Gross Measurement Number of Measurements: 15 Operational DCGL: 1 BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Ni-63 Minimum Value: -5.66E-03 -2.33E-02 -1.36E+01 Maximum Value: 5.27E-01 9.04E-01 -1.97E+00 Mean: 1.71E-01 2.03E-01 -8.12E+00 Median: 1.65E-01 1.06E-01 -7.67E+00 Standard Deviation: 1.60E-01 2.58E-01 4.05E+00 RADIONUCLIDE CONCENTRATION (pCi/g)

NUMBER Cs-137 Co-60 Ni-63 Identified? Identified? Identified?

9106-0009-001F 1.65E-01 1.18E-01 -1.97E+00 Y Y N 9106-0009-002F 5.27E-01 9.04E-01 -1.20E+01 Y Y N 9106-0009-003F O.OOE+00 1.52E-02 -7.67E+00 N N N 9106-0009-004F -5.66E-03 1.99E-02 -2.23E+00 N N N 9106-0009-005F 1.91E-01 1.06E-01 -1.30E+01 Y Y N 9106-0009-007F 1.03E-01 6.71 E-02 -1.36E+01 Y Y N 9106-0009-008F 3.72E-02 4.83E-02 -1.29E+01 Y Y N 9106-0009-009F 3.97E-01 4.58E-01 -7.24E+00 Y Y N 9106-0009-01 OF 1.56E-01 1.53E-01 -4.44E+00 Y Y N 9106-0009-01 IF 2.14E-03 -2.33E-02 -1.23E+01 N N N 9106-0009-013F 2.85E-02 O.OOE+0O -3.87E+00 N N N 9106-0009-014F 2.17E-01 6.26E-02 -1.04E+01 Y Y N 9106-0009-015F 1.86E-01 3.34E-01 -8.35E+00 Y Y N 9106-0009-016F 1.70E-01 2.39E-01 -6.30E+00 Y Y N 9106-0009-017F 3.88E-01 5.37E-01 -5.48E+00 Y Y N Performed By: Date: #-/- 0,ý fM 2X.ý-

Independent Review: Date:

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2d Graphical Representation of Data (6 Pages)

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cesium - 137 Survey Unit: 9106-0009 Survey Unit Name: Discharge Canal Mean: 1.71E-01 pCi!g 6.OOE-01

,, 5.OOE-01 - -

O 4.OOE-01 , * -

0 3.OOE-01-.......

., 2.OOE-01 - --- *

=o1.00E-01 *" '

0 C) .OOE+OO --

20 40 60' 80 "1q Percentage Cs-1 37 Rank Percentage

-5.66E-03 1 3 %

0.OOE+00 2 10 %

2.14E-03 3 17 %

2.85E-02 4 23 %

3.72E-02 5 30 %

1.03E-01 6 37 %

1.56E-01 7 43 %

1.65E-01 8 50 %

1.70E-01 9 57 %

1.86E-01 10 63 %

1.91E-01 11 70%

2.17E-01 12 77 %

3.88E-01 13 83 %

3.97E-01 14 90 %

5.27E-01 15 97 %

Prepared By: Date: -Oz Reviewed By: Date: ///,_

Quantile Plot For Cobalt - 60 Survey Unit: 9106-0009 Survey Unit Name: Discharge Canal Mean: 2.03E-01 pCi/g 1.OOE+00

.. 8.OOE-01 c 6.OOE-01 0

4.00E-01 o 2.OOE-01 - -

0 "0 0 0.00E+00 * *- - - - -

2'0 40 60 8 1e0 Percentage Co-60 Rank Percentage

-2.33E-02 1 3 %

0.OOE+00 2 10 %

1.52E-02 3 17 %

1.99E-02 4 23 %

4.83E-02 5 30 %

6.26E-02 6 37 %

6.71 E-02 7 43 %

1.06E-01 8 50 %

1.18E-01 9 57 %

1.53E-01 10 63 %

2.39E-01 11 70 %

3.34E-01 12 77 %

4.58E-01 13 83 %

5.37E-01 14 90 %

9.04E-01 15 97 %

Prepared By: , I-V"" zo,

  1. 2,1 Date: //- -,9/

Reviewed By: , Date: /1 /-! tb

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attaclunent C Quantile Plot For Nickel-63 Survey Unit: 9106-0009 Survey Unit Name: Discharge Canal Mean: -8.12E+00 pCi/g 0.OOE+00

-2.OOE+00 20 40 6, 80

-4.OOE+O0 --

0.-6.00E+00

"- -8.OOE+0 -

5-1.20E+01 -

-1.40E+01 -

-1.60E+01 _-

Percentage Ni-63 Rank Percentage

-1.36E+01 1 3 %

-1.30E+01 2 10 %

-1.29E+01 3 17 %

-1.23E+01 4 23 %

-1.20E+01 5 30 %

-1.04E+01 6 37%

-8.35E+00 7 43 %

-7.67E+00 8 50 %

-7.24E+00 9 57 %

-6.30E+00 10 63 %

-5.48E+00 11 70 %

-4.44E+00 12 77 %

-3.87E+00 13 83 %

-2.23E+00 14 90 %

-1.97E+00 15 97 %

Prepared By: Date: /( -j'- ",1 Reviewed By: Date: ii /D

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cesium-137 Survey Unit: 9106-0009 Survey Unit Name: Discharge Canal Mean: 0.171 pCi/g 7

6 5

C.) 4 d) 3 LL 2 1

0 I- -K -- -I 0.00 0.10 0.20 0.30 0.40 0.50 0.60 Upper End Value (pCi/g)

Upper End Observation Observation %

Value Frequency Frequency 0.00 2 13%

0.10 3 20%

0.20 6 40%

0.30 1 7%

0.40 2 13%

0.50 0 0%

0.60 1 7%

Total 15 100%

Prepared By: Date: / )--- 0, Reviewed By: Date: o, z/"/,

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cobalt-60 Survey Unit: 9106-0009 Survey Unit Name: Discharge Canal Mean: 0.203 pCi/g Upper End Observation Observation %

Value Frequency Frequency 0.00 2 13%

0.20 8 53%

0.40 2 13%

0.60 2 13%

0.80 0 0%

1.00 1 7%

Total 15 100%

Prepared By: Date: / -3/-Q Reviewed By: -ý '44ý Date: /1 .16

/7

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Nickel-63 Survey Unit: 9106-0009 Survey Unit Name: Discharge Canal Mean: -8.117 pCi/g 6

5 4--4 "m0*

2

-12 -10 -8 -6 -4 -2 0 Upper End Value (pCi/g)

Upper End Observation Observation %

Value Frequency Frequency

-12 5 33%

-10 1 7%

-8 1 7%

-6 3 20%

-4 2 13%

-2 2 13%

0 1 7%

Total 15 100%

Prepared By: Date: #-/-az Reviewed By: Date: Il / 4 7

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2e Sign Test Calculation (1 Page)

Health Physics Procedure GPP-GGGR-R5121-000 Attachment A, Rev. CY-001 MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes Survey Unit Number: 9106-0009 Survey Unit Name: Discharge Canal WP&IR#: 2006-021 Classification : 2 [ TYPE I (a error):0.05 ITYPE I (P3error):0.05[

Radionuclides: Cs-137 Co-60 Ni-63 Survey Design DCGL (pCi/g): 6.01 2.9 549 Results Cs-137 Results Co-60 Results Ni-63 Weighted Sum (W,) DCGL-Result Sign 1.65E-01 1.18E-01 1.18E-01 1.24E-01 8.76E-0I

  • 5.27E-01 9.04E-01 9.04E-01 3.91E-01 6.09E-01 0.00E+00 1.52E-02 1.52E-02 5.05E-02 9.49E-01

-5.66E-03 1.99E-02 1.99E-02 6.11E-02 9.39E-01 1.91E-01 1.06E-01 1.06E-01 1.04E-01 8.96E-01 1.03E-01 6.71 E-02 6.71E-02 7.48E-02 9.25E-01 3.72E-02 4.83E-02 4.83E-02 5.86E-02 9.41E-01 3.97E-01 4.58E-01 4.58E-01 2.70E-01 7.30E-01 1.56E-01 1.53E-01 1.53E-01 1.30E-01 8.70E-01 2.14E-03 -2.33E-02 -2.33E-02 4.49E-02 9.55E-01 2.85E-02 0.OOE+00 0.OOE+00 5.70E-02 9.43 E-01 2.17E-01 6.26E-02 6.26E-02 1.89E-01 8.11E-01 1.86E-01 3.34E-01 3.34E-01 1.90E-01 8.10E-01 1.70E-01 2.39E-01 2.39E-01 1.59E-01 8.41E-01 3.88E-01 5.37E-01 5.37E-01 2.38E-01 7.62E-01 Number of Positive Differences (S+): 15 Critical Value: 11 Survey Unit: Meets Acceptance Criterion Date: */( -/-Q~ 2 Performed By: _'-* )'L"*-*'

Independent Review: Date: 4 16,;

Note Weighted Sum values i des HTD components. See Compass run for more detail.

Page 1 of 1

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (4 Pages)

DQA Surface Soil Report Assessment Summary Site: 9106-0009 (19mrem/yr)

Planner(s): Dale Randall Survey Unit Name: 9106-0009 Report Number: 1 Survey Unit Samples: 15 Reference Area Samples: 0 Test Performed: Sign Test Result: Not Performed Judgmental Samples: 0 EMC Result: Not Performed Assessment

Conclusion:

Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve 1

U 0.9 zJ~zz_ _-

_--71-I-

.4-

=

0.8 *zzI~z ______ ___ - ______

I-0.7 zii! ______ ___ i

  • ______

______

___

___ - Zilijili ______

0.6 C,

0.5 zz!~z

-I:- ______

-

-

- zizzii[

0.4 4 0.3 -Ii-0.2 ztIz

-.1:---

______ -

-~_

-

1~

0.1 ______ - - -4 0 iizIizzz ______ ______ - - ______

0.0 0.2 0.4 0.6 0.8 1.0 1.2 Unity Rule Sum-of-Ratios, including background

- - Prospective Power I1-beta .... Actual Power

,,- LBGR - - Estimated Power i DCGL ---- Retrospective Power COMPASS vl.0.0 1013112006 Page I

DQA Surface Soil Report Survey Unit Data NOTE: Type = "S" indicates survey unit sample.

Type = "R" indicates reference area sample.

Sample Number Type Cm-244 (pCi/g) Co-60 (pCi/g) Cs-137 (pCi/g) 9106-0009-001 F S 0.33 0.12 0.16 9106-0009-002F S 0.01 0.9 0.53 9106-0009-003F S 0.33 0.02 0 9106-0009-004F S 0.33 0.02 -0.01 9106-0009-005F S 0.33 0.11 0.19 9106-0009-007F S 0.33 0.07 0.1 9106-0009-008F S 0.33 0.05 0.04 9106-0009-009F S 0.33 0.46 0.4 9106-0009-01OF S 0.33 0.15 0.16 9106-0009-011 F S 1.39 -0.02 0 9106-0009-013F S 0.33 0 0.03 9106-0009-014F S 0 0.06 0.22 9106-0009-015F S 0.33 0.33 0.19 9106-0009-016F S 0.33 0.24 0.17 9106-0009-017F S -0.07 0.54 0.39 Sample Number Type H-3 (pCi/g) Ni-63 (pCi/g) 9106-0009-001 F S 13.82 -1.97 9106-0009-002F S 4.12 -12 9106-0009-003F S 13.82 -7.67 9106-0009-004F S 13.82 -2.23 9106-0009-005F S 13.82 -13 9106-0009-007F S 13.82 -13.6 9106-0009-008F S 13.82 -12.9 9106-0009-009F S 13.82 -7.24 9106-0009-01 OF S 13.82 -4.44 9106-0009-011 F S 3.69 -12.3 9106-0009-013F S 13.82 -3.87 9106-0009-014F S 46.9 -10.4 9106-0009-015F S 13.82 -8.35 9106-0009-016F S 13.82 -6.3 9106-0009-017F S 0.58 -5.48 COMPASS vI.0.0 1013112006 Page 2

'IWJ DQA Surface Soil Report Modified Data (Unity Rule SOR)

NOTE: Type = "S" indicates survey unit sample.

Type = "R" indicates reference area sample.

Sample Number Type Sum-of-Ratios (SOR) 9106-0009-001 F S 0.12 9106-0009-002F S 0.39 9106-0009-003F S 0.05 9106-0009-004F S 0.06 9106-0009-005F S 0.1 9106-0009-007F S 0.07 9106-0009-008F S 0.06 9106-0009-009F S 0.27 9106-0009-01 OF S 0.13 9106-0009-011 F S 0.05 9106-0009-013F S 0.06 9106-0009-014F S 0.19 9106-0009-015F S 0.19 9106-0009-016F S 0.16 9106-0009-017F S 0.24 COMPASS vI.0.P 10/3112006 Page 3

  • ff? DQA Surface Soil Report Basic Statistical Quantities Summary Statistic Survey Unit Background DQO Results Sample Number 15 N/A N=13 Mean (SOR) 0.14. N/A 0.09 Median (SOR) 0.12 N/A N/A Std Dev (SOR) 0.10 N/A 0.07 High Value (SOR) 0.39 N/A N/A Low Value (SOR) 0.05 N/A N/A COMPASS vl.0.0 10/3112006 Page 4