IN m :1ook10] of 17!m Or r kA Final Status Survey Final Report Phase IV Appendix A9 Survey Unit Release Record 9106-0009, Discharge Canal November 2006 CYAPCO FINAL STATUS SURVEY RELEASE RECORD DISCHARGE CANAL SURVEY UNIT 9106-0009 Prepared By: FSS Engineer ._Date: _ -_ -__Date: Reviewed By: Approved By//f 4,( c. ,/val,, Techni'cal Support Manager Date: /Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD TABLE OF CONTENTS 1. SURVEY UNIT DESCRIPTION

.................................................................

3 2. CLASSIFICATION BASIS ......................................................................

3 3. DATA QUALITY OBJECTIVES (DQO) ....................................................

5 4. SURVEY DESIG N .....................................................................................

8 5. SURVEY IMPLEMENTATION

................................................................

11 6. SURVEY RESULTS ...............................................................................

12 7. QUALITY CONTROL .............................................................................

14 8. INVESTIGATIONS AND RESULTS ......................................................

14 9. REMEDIATION AND RESULTS .............................................................

15 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN .....................

15 11. DATA QUALITY ASSESSMENT (DQA) .................................................

15 12. A NO M A LIES ...........................................................................................

16 13. CO NCLUSIO N .......................................................................................

16 14. ATTACHM ENTS .....................................................................................

17 14.1 Attachment 1 -Figures (6 pages including cover)14.2 Attachment 2 -Sample and Statistical Data (200 pages including covers)Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9106-0009 (Discharge Canal) is designated as Final Status Survey (FSS) Class 2 and consists of approximately 9,933 m 2 (2.45 acres) of water covered sediment in an area located approximately 1.02 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (HNP)(see Attachment 1, Figure 1). The Discharge Canal is a man-made mile long waterway that runs parallel to, and ultimately communicates with, the Connecticut River. The Discharge Canal is subdivided into fifteen (15) survey units including two (2) permanent wetland areas for FSS purposes.

The survey unit is bounded as follows: Discharge Canal Survey Unit 9106-0008 is to the north (called north as orientated with the north to south flow of the Connecticut River), Survey Area 9523 is to the east, Discharge Canal Survey Unit 9106-0010 is to the south and South Peninsula Survey Area 9531 (formerly a part of 9530) is to the west. The survey unit comprises the canal sediments to the deeper of three (3) feet or the original construction depth and it extends up the canal banks to the mean high water level.The reference coordinates associated with this survey unit are E018 through E027 by S148 through S161 (refer to License Termination Plan Section 5.4.4).The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10,"Survey Unit Classification. " The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9106-0009 as Class 2 in May 2006.The "Classification Basis Summary" conducted for this survey unit consisted of: a) A review of the IOCFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment (HSA) Supplement, " c) Historic and current survey records review, d) Visual inspections and a "walkdown." e) Formal or informal interviews with cognizant personnel.

A review of the 1OCFR50.75(g)(1) database report identified a number of events that may have impacted this survey unit. In 1986, samples were taken from the legacy dredge spoils removed in 1979 dredged spoils area and from recently dredged canal sediment.

The sample analyses indicated that the Revision 0 3 Revision 0 3 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD concentrations of Cs-137, Co-60 and other radionuclides were a small fraction of the DCGLs for those nuclides that could be identified by gamma spectroscopy. (refer to NE-86-RA-1142 dated 11-13-86).

None the available historical information reviewed would support a conclusion that any residual activity in this survey unit is likely to be present at concentrations greater than the respective DCGLs Additional information was provided by several historical documents, including the "Results of Scoping Survey", (completed 9/1/98), the "Historical Site Assessment", and the HSA Supplement (dated 6-30-00).

These documents presented the results of several sediment samples taken in 1997. These sample results indicated concentrations of 0.5 pCi/g for Co-60, 0.024pCi/g for Cs-134 and 0.722 pCi/g for Cs-137.An initial characterization survey was implemented during April and May of 2004. Six (6) samples from three (3) locations were obtained by biased sampling throughout the area. The samples were analyzed off-site by gamma spectroscopy and with radiochemical analyses for Sr-90 and Tritium. Hard-to-Detect analyses were also conducted on one (1) of the six (6) samples. The only plant-related dosimetrically significant radionuclides identified in the samples were Cs-137, Cobalt-60 and Ni-63. No samples indicated radioactive material in quantities above the ten (10) mrem/yr design DCGL. Cobalt-60 accounted for the majority of the dose in these samples with a maximum concentration of 0.57 pCi/g.A final characterization was performed by Site Closure personnel in April of 2006. Six (6) sediment samples from six (6) locations were taken. All of the samples were analyzed by gamma spectroscopy.

Based on the initial and final characterization results, the radionuclides of concern identified in the sample data for FSS planning purposes were Cesium-137, Cobalt-60 and Ni-63. Since HTD analyses were not performed for all radionuclides of interest during characterization, additional HTD analyses were performed as a part of the FSS.The statistics for each of the radionuclides of concern are listed in Table 1.Revision 0 4 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD iviinimum vaiue: i .VL-IJ -1 .&4t-uz -I .oL-1-uu Maximum Value: 4.24E-01 3.82E-01 3.47E+01 Mean: 1.34E-01 1.1 7E-01 1.65E+01 Median: 9.43E-02 8.56E-02 1.65E+01 Standard Deviation:

1.58E-01 1.41 E-0 1 2.57E+0 I NOTE: The Operational DCGLs are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 549 pCi/g for Ni-63; these are used in conjunction with the unity rule to achieve nineteen (19)mrem/yr TEDE The FSS Engineer performed a visual inspection and walk-down during May 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGLs justifying a final survey unit classification of Class 2 (refer to Section 3).3. DATA QUALITY OBJECTIVES (DQO)FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM).

A summary of the main features of the DQO process are provided herein.The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis.

Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition.

The baseline condition is technically known as the null hypothesis.

Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection.

In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria.

Rejection of the null hypothesis would satisfy the release criteria objective of the FSS.The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9106-0009 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).Revision 0 5 Revision 0 5 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the development of Derived Concentration Guideline Levels (DCGLs). The DCGLs represent the concentration of radioactivity above background, equivalent to a dose-based release criterion and is presented in terms of surface or mass activity concentrations.

Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), for existing groundwater radioactivity and for future groundwater radioactivity that will be contributed by building foundations and footings.As described in detail in the LTP, the dose model applied to the discharge canal presumes that the canal sediments are dredged to a depth of three (3) feet below the top of the sediment layer and spread for the planting of crops per the Resident Farmer Scenario.

Consequently, the soil DCGLs are directly applied to the canal sediment media.The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.Equation 1: HTotai=Hsoil (sediment)

+/- HExisting GW +/- HFuture GW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from sediment must be reduced when using the existing and future groundwater dose values discussed above.This survey unit is not affected by either existing groundwater or by future groundwater (reference CY memo ISC 06-024). Therefore, dose contribution from both existing and future groundwater is zero (0) mrem/yr TEDE, based on field data.Equation 2.19 mrem/yrTotal=

19 mrem/yrso 0 j+0 mrem/yrExisting GW+O mrem/yrFuture GW The allowable dose for sediment in this survey unit is nineteen (19) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in nineteen (19) mrem/yr TEDE is designated as the Revision 0 6 Revision 0 6 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.Table 2 -Radionuclide Specific Base Case Soil CG3L, Operatiokal DCGLs~Radioniuclide

()UBase Case Soil Operational DCGL ~Required MiC~DCGL (pCiig) () (I)Ci g) (3 (4 H-3 4.12E+02 3.131E+02 1.65E+01 C-14 5.66E+00 4.30E+00 2.26E-01 Mn-54 1.74E+O1 1.32E+01 6.96E-01 Fe-55 2.74E+04 2.08E+04 1.1OE+03 Co-60 3.81 E+00 2.90E+00 1.52E-0 I Ni-63 7.23E+02 5.49E+02 2.89E+O1 Sr-90 1.55E+00 1.1 8E+00 6.20E-02 Nb-94 7.12E+00 5.41 E+00 2.85E-0 1 Tc-99 1.26E+O1 9.58E+00 5.04E-01 Ag-108m 7.14E+00 5.43E+00 2.86E-01 Cs-134 4.67E+00 3.55E+00 1.87E-01 Cs-137 7.91E+00 6.01E+00 3.16E-01 Eu- 152 1.01 E+01 7.68E+00 4.04E-01 Eu-154 9.29E+00 7.06E+00 3.72E-01 Eu-155 3.92E+02 2.98E+02 1.57E+01 Pu-238 2.96E+01 2.25E+01 1.18E+00 Pu-239/240 2.67E+01 2.03 E+01 I1.07E+00 Pu-241 8.70E+02 6.61E+02 3.48E+01 Am-241 (5) 2.58E+01 1.96E+O 1.03E+00 Cm-243/244 2.90E+OI 2.20E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE (3) The Operational DCGL is equivalent to nineteen (19) mrem/yr TEDE (4) The required MDC is equivalent to one (1) mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Revision 0 7 Revision 0 7 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

Characterization was completed in April of 2006 as discussed in Section 2. Cesium-137, Cobalt-60 and Nickel-63 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137, Co-60 and Ni-63 are provided in Table 1.Laboratory DQOs and analysis results were to be reported as actual calculated results. Results reported as less than Minimum Detectable Concentration

(<MDC) would not be accepted for FSS. Sample report summaries were to include unique sample identification, analytical method, radionuclide, result, and uncertainty of two standard deviations, laboratory data qualifiers, units, and the required and observed MDC.4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans ".This survey was initially designed to ten (10) mrem/yr TEDE. At the time when the survey was designed, the dose contribution for existing and future groundwater had not yet been determined.

Subsequently, a conservative value was chosen for the Operational DCGL. This approach is no longer required as the total dose from existing and future groundwater has been established.

The dose for soil used for this survey unit to demonstrate compliance with the LTP criteria is nineteen (19) mrem/yr TEDE, as discussed in Section 2 of this Release Record.The DQO process determined that Cs-137, Co-60 and Ni-63 were the radionuclides of concern (refer to Section 3). The sum of fractions or unity rule was used with the individual Operational DCGLs because multiple radionuclides (Cs-137, Co-60 and Ni-63) were considered in the survey design.Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening process described in LTP Section 5.4.7.2, "Gross Activity DCGLs". Ni-63 concentrations in sediment and soil were ascertained by direct analysis.Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations that are less than 5%for individual radionuclides and that are less than 10% for the aggregate of all radionuclides that are de-selected.

This process was applied to analysis data for this survey unit.Revision 0 8 Revision 0 8 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD The Elevated Measurement Comparison (EMC) did not apply to this survey unit since the survey unit is a Class 2 and discrete, elevated areas of contamination were not expected.The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

This approach was conservative since it included background Cs-137 as part of the sample set.The number of sediment samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Samples for Final Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.724 to maintain the relative shift (A/o) in the range of 1 and 3. The resulting relative shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.This indicates that the survey unit has a high probability of rejecting the null hypothesis, assuming that the characterization data are representative of the FSS results. Survey design specified fifteen (15) sediment core samples for non-parametric statistical testing.The grid pattern and locations of the sediment samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14,"Identifying, and Marking Surface Sample Locations for Final Status Survey. " Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.Revision 0 9 Revision 0 9 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Table 3 -Sample&Muasurerne2nt Locations with iAssociated GPS C~oordinates' signtlonNorthing., FEasting, 9106-0009-001F 234282.36 673022.88 9106-0009-002F 234282.36 673113.80 9106-0009-003F 234203.62 673068.34 9106-0009-004F 234203.62 673159.25 9106-0009-005F 234124.88 673113.80 9106-0009-007F 234046.15 673159.25 9106-0009-008F 233967.41 673113.80 9106-0009-009F 233967.41 673204.71 9106-0009-01 OF 233888.68 673159.25 9106-0009-011 F 233888.68 673250.17 9106-0009-013F 233809.94 673204.71 9106-0009-014F 233731.21 673159.25 9106-0009-015F 233731.21 673250.17 9106-0009-016F 234078.97 673143.18 9106-0009-017F 234023.32 673157.00 The sample location designations of Table 3 are not sequentially inclusive because of the necessity to relocate some samples due to the accessibility of the original sample locations.

Samples locations 9106-0009-006F and 9106-0009-01 2F were found to be on dry land, consequently, they were randomly relocated using the VSP software to two (2) new locations designated as 9106-0009-016F and 9106-0009-017F.

Since sample 9106-0009-006F was randomly selected as a Quality Control (QC) split sample, 9106-0009-016F was designated as the replacement QC sample.Four (4) sediment samples were analyzed for the full suite of radionuclides specified in Table 1, exceeding the requirement to analyze 5% of the sample population for HTD analysis specified in procedure RPM 5.1-11. Two (2) of the four (4) samples were randomly selected using the Microsoft Excel"RAND" function.

The two (2) samples exhibiting the highest observed radionuclide concentrations by gamma analyses were also selected.The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, " required the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory.

These locations were selected randomly using the Microsoft Excel"RAND" function.

The number of quality control samples exceeded the 5%requirement as specified by the LTP.Section 5.7.3.2.6 of the LTP specifies that scanning is not required for the FSS of the Discharge Canal. Table 4 provides a synopsis of the survey design.Revision 0 10 Revision 0 10 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Tci liable 4 -§Svn-osis of the Suiw esln :<Feature 1 Des~ig riterili i< Basis>>Survey Unit Land m2 Based on AutoCAD-LT and Visual Area Sample Plan calculations Type I and Type 2 errors were 0.05, Number of 15 sigma was 0.138 the LBGR was set to Measurements 0.724 to maintain Relative Shift in the range of I and 3, Relative Shift was 2.0 Grid Spacing 27.4 m Based on triangular grid 3.16 pCi/g Cs-137 Design DCGL 1.52 pCi/g Co-60 To achieve ten (10) mrem/yr TEDE 289 pCi/g Ni-63 Operational 6.01 pCi/g Cs-137 To achieve nineteen (19) mrem/yr DCGL 2.90 pCi/g Co-60 TEDE (2) to demonstrate compliance

_ _ _ _ 549 pCi/g Ni-63 with Equation 2 of this Release Record Scan Coverage N/A The LTP exempts this area Sediment 6.01 pCi/g Cs-137 The Operational DCGL meets the LTP Investigation 2.90 pCi/g Co-60 criteria for a Class 2 survey unit Level 549 pCi/g Ni-63 (1) The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 as the total dose from existing and future groundwater had not been established at the time of planning the FSS 5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0021.

The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.Measurement locations were identified in North American Datum (NAD) 1927 coordinates that were supplied to the sampling vendor, Ocean Survey, Inc.(OSI) of Old Saybrook, Connecticut.

Discharge Canal sampling was accomplished using direct push technology to collect composite samples of bottom and mean high water mark sediments.

Sediment cores from the Discharge Canal were obtained by OSI using a vibrating corer that is platform mounted on a sampling vessel. The core barrel was a three (3) inch diameter thin-walled aluminum tube which also served as a core liner (ten (10) feet or less). A core catcher was available to prevent the sample from sliding out of the bottom of the tube. Vessel positioning and the determination of sample locations were accomplished using a GPS interfaced with a navigation and data logging system.After extraction, water was drained from above the sample by drilling holes above the sediment.

The liner was cut, capped, sealed, labeled and turned over Revision 0 I1I Revision 0 11 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD to site personnel who processed and controlled the samples under Chain of Custody (COC) protocols in accordance with procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples." Rinsing of the barrel and associated equipment was performed between sampling events. New aluminum tubes were used for each sample to prevent cross-contamination of subsequent samples.The fifteen (15) sediment samples were collected and packaged in accordance with Haddam Neck Plant (I-INP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey". Samples were controlled, transported, stored, and transferred to the off-site laboratory using COC protocols.

Four (4) samples (9106-0009-002F, 9106-0009-01 IF, 9106-0009-014F and 9106-0009-017F) were selected for HTD radionuclide analysis by the off-site laboratory.

Two (2) of these samples (011F and 014F) were selected at random. The other two (2) were selected based of being the most dosimetrically significant samples based on spectroscopic gamma analyses.The implementation of survey specific quality control measures included the collection of two (2) split samples at locations 9106-0009-013F and 9106-0009-016F for "split sample" analysis by the off-site laboratory.

6. SURVEY RESULTS The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) -Charleston, South Carolina.

The laboratory analyzed the fifteen (15) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy.

Ni-63 was analyzed by liquid scintillation analysis.

All analyses were performed to the required MDC.Cesium-137 was identified in eleven (11), Co-60 was identified in eleven (11), and Ni-63 in none of the fifteen (15) samples. The results reported for the remaining sample analyses indicated that activity was present at levels approaching or below the established detection limits in the remaining samples collected and analyzed for non-parametric testing.Several other radionuclides which were positively identified (i.e., a result greater than two (2) standard deviations uncertainty) could be de-selected or excluded using the 5% and 10% rule described in Section 5.4.7.2 of the LTP.The off-site laboratory also processed four (4) samples for full HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy and liquid scintillation depending upon the radionuclide and the measurement method. All analyses were performed to the required MDC. A number of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty) in more than one (1)Revision 0 12 Revision 0 12 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD sample. However, only H-3 and Cm-243/244 could not be de-selected based on the 5% and 10% rules.None of the sample results exceeded the Operational DCGL or required further investigation.

A summary of the sample results is provided in Table 5.9106-0009-001 F 1.65E-01 1.18E-01-1.97E+00 6.46E-02 1.24E-01 9106-0009-002F 5.27E-01 9.04E-0 1 -1.20E+01 3.78E-01 3.91 E-0 I 9106-0009-003F O.OOE+00 1.52E-02 -7.67E+00

-8.73E-03 5.05E-02 9106-0009-004F

-5.66E-03 1.99E-02 -2.23E+00 1.86E-03 6.11E-02 9106-0009-005F 1.91E-01 1.06E-01 -1.30E+01 4.47E-02 1.04E-01 9106-0009-007F 1.03E-01 6.71 E-02 -1.36E+01 1.55E-02 7.48E-02 9106-0009-008F 3.72E-02 4.83E-02 -1.29E+01

-6.52E-04 5.86E-02 9106-0009-009F 3.97E-01 4.58E-01 -7.24E+00 2.11 E-0 I 2.70E-01 9106-0009-01 OF 1.56E-01 1.53E-01 -4.44E+00 7.06E-02 1.30E-01 9106-0009-011 F 2.14E-03 -1.89E-02

-1.23E+01

-2.86E-02 4.64E-02 9106-0009-013F 2.85 E-02 0.OOE+00 -3.87E+00

-2.31 E-03 5.70E-02 9106-0009-014F 2.17E-01 6.26E-02 -1.04E+01 3.87E-02 1.89E-01 9106-0009-015F 1.86E-01 3.34E-01 -8.35E+00 1.31E-0I 1.90E-01 9106-0009-016F 1.70E-01 2.39E-01 -6.30E+00 9.92E-02 1.59E-01 9106-0009-017F 3.88E-0 1 5.37E-01 -5.48E+00 2.40E-01 2.38E-01 (1)(2)The Operational DCGLs from Table 2 are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 549 for Ni-63; these are used in conjunction with the unity rule to achieve nineteen (19)mrem/yr TEDE.This column is the sum of the DCGL unity fraction from identified radionuclides of concern and HTD isotopes (H-3 and Cm-243/244) exceeding the 5%/10% rule for one or more FSS samples. For those samples not measured for HTD isotopes, an average calculated value of 5.9% of the DCGL was added to each sample. The average was calculated by adding the sample results for H-3 and Cm-243/244 of all the samples analyzed for those HTD isotopes, provided in Table 6 and dividing by the total number of samples analyzed for that radionuclide.

This average value was applied to those samples that were not analyzed for HTD isotopes.

If the sample was analyzed for HTDs, then the reported value was used instead of the average value.NOTE: The off-site laboratory reported that all fifteen (15) of the samples analyzed for Ni-63, within this survey unit, had a negative value reported.These negative values when used to determine the fraction of the Operational DCGL for the Radionuclide(s) of Concern had a maximum effect of lowering the fraction of the Operational DCGL present by less than 2.5% and the corresponding assigned dose for this survey unit by less than 0.5* mrem/yr TEDE.Revision 0 13 Revision 0 13 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD*[-13.6 pCi/g (Maximum reported negative value for Ni-63) + 549 pCi/g (Operational DCGL for Ni-63) x 19 mrem/yr TEDE per DCGL = -0.471 mrem/yr TEDE z -0.5 mrem/yr TEDE]The off-site laboratory also processed four (4) samples for HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC. Four (4) of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one sample. Each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules, with the exceptions of Cm-243/244 and H-3.These results are presented in Table 6.-T. able Samp Results ...,.~Samnple Number H. -3 Cmi243/244 .Fraction ofthe (2 PCiCu +c/ Operational D('(; 1, 9106-0009-002F 4.12 0.013 0.0138 9106-0009-011F 3.69 1.39 0.0750 9106-0009-014F 46.9 0.00 0.1498 9106-0009-017F 0.58 -0.073 -0.0015 (1) The Operational DCGL from Table 2 is 313 pCi/g for H-3 and 22.0 pCi/g for Cm-243/244.(2) This represents the unity fraction of the DCGL from nuclides that are were not considered nuclides of concern from the FSS.Biased samples were not called for in the sample plan.7. QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis.

Two (2) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 and as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey. " There was acceptable agreement between the field split results for both of the "split sample" pairs tested.The sample analysis vendor, General Engineering Laboratories (GEL) -Charleston, South Carolina, maintained quality control and quality assurance plans as part of normal operation.

Refer to Attachment 2 for data and data quality analysis results.8. INVESTIGATIONS AND RESULTS No investigations were required to be performed since none of the sample results exceeded the investigation levels.Revision 0 14 Revision 0 14 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD 9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.10. CHANGES FROM THE FINAL STATUS SURVEY PLAN The survey was designed to ten (10) mrem/yr TEDE which was conservative and necessary at the time of FSS planning.

It is no longer required as the total dose from existing and future groundwater has been established.

The dose for sediment used to demonstrate compliance with the LTP criteria is nineteen (19)mrem/yr TEDE as discussed in Section 2 of this Release Record.11. DATA QUALITY ASSESSMENT (DQA)The DQO sample design and data were reviewed in accordance with Procedure The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment. " The sample design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs.The evaluation of the Sign Test results indicates that the survey unit passes the unrestricted release criterion, thus, the null hypothesis is rejected.Documenation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation).

The sample standard deviation was slightly more than the value used for the survey design. This is represented by the shift in the retrospective power curve as shown in Attachment 2f. This would indicate a change to the original LBGR to maintain the number of samples at fifteen (15) to meet the Operational DCGL. However, the value of LBGR is less of a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL when used in conjunction with the unity rule. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the release criteria with adequate power as required by the DQOs.Revision 0 15 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD The range of the data, about 3.58 standard deviations, was not unusually large.The difference between the mean and median was 34% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 1.52.All data, assessments, and graphical representations are provided in Attachment 2.12. ANOMALIES The finding of two (2) HTD radionuclides in excess the screening criteria was the only anomaly associated with the FSS of this survey unit. Additionally, the testing of additional samples for HTDs has failed to yield additional positive results for either H-3 or Cm-243/244.

For conservatism, the HTD results were factored into all statistical evaluations of the survey data for this survey unit accounting for any possible dose contributions.

This action does not alter the conclusion that this survey unit meets the criteria for unconditional release.No other anomalies were noted in the performance of this FSS.13. CONCLUSION Survey Unit 9106-0009 has demonstrated compliance with the dose based, unrestricted release criterion.

The sample data passed the Sign Test and the null hypothesis was rejected.

The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved.

Reclassification and remediation of this survey unit was not required.Graphical representation of data indicates some positive skewness that is probably due to localized differences in particulate deposition rates, hydraulic velocity and sedimentation rates. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved.

The survey unit was properly designated as a Class 2 survey unit.As stated in Section 6, all fifteen (15) sample results reported for Ni-63 were negative values. These negative values were used when determining the sum of the fractions (unity rule) and, therefore, lowered the reported fraction of the Operational DCGL. In the interests of conservatism, the maximum dose contribution from the negative impact of using these values will be added to the total dose for this survey unit. The maximum dose contribution for Ni-63 is less than 0.5 mrem/yr TEDE.The dose contribution from sediment is 3.2 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.Revision 0 16 Revision 0 16 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD This survey unit is not affected by existing groundwater (reference CY memo ISC 06-024). It has been determined that the dose contribution from groundwater sources is zero (0) mrem/yr TEDE.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component, is therefore zero (0) mrem/yr TEDE.The average total dose from residual radioactivity in this survey unit, including that from sediment, will not exceed 3.2 mrem/yr Total Effective Dose Equivalent (TEDE).14. ATTACHMENTS 14.1 Attachment 1 -Figures 14.2 Attachment 2 -Sample and Statistical Data Revision 0 17 Revision 0 17 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 1 Figures (5 pages) n V; :/ P 0 420 840 Cbadhow mmi NAD27CucoW~j Sh*bfl~w 1/P Connecdcut Yankee Atomic Power Company Site Map With Referece To Survey Unit 9106-0008 Le wd Sample Location SInsoacesble saple Location NAD27Ccmweedo SA*Phwyw 13 0 0 42.5 55 MWIZ== = Fed 14 0 Connecticut Yankee Atomic Power Company 9106-0009 Final Status Survey Design 4..Sample Location SInaccessible sample Location ANc Coamdbow m in NAtW27Wamw&U awhWn-M C-k!n-l37rm A~jW~iMzm$*

0.0285 0 0 42.5 85 Feet 0.217 Connecticut Yankee Atomic Power Company 9106-0009 Final Status Survey Cesium-13 7Posting Plot

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2 Sample and Statistical Data DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2a Sample Data (179 Pages)

General Narrative 1 CASE NARRATIVE For CONNECTICUT YANKEE RE: Soils PO# 002332 Work Order: 164542 SDG: MSR #06-0818 June 7, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID 164542001 164542002 164542003 164542004 164542005 164542006 164542007 164542008 164542009 164542010 164542011 Client Sample ID 9106-0009-016F 9106-0009-016FS 9106-0009-017F 9106-0009-013F 9106-0009-013FS 9106-0009-015F 9106-0009-001F 9106-0009-002F 9106-0009-003F 9106-0009-004F 9106-0009-005F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712

  • Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171 -Fax843) 766-1178 ° www.gel.com 164542012 9106-0009-007F 164542013 9106-0009-008F 164542014 9106-0009-009F 164542015 9106-0009-OIOF 164542016 9106-0009-01 IF 164542017 9106-0009-014F Items of Note: There are no items of note.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Two soil samples were analyzed for FSSALL. Fifteen soil samples were analyzed for FSSGAM and Ni-63.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.RO. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)Phone (843) 556-8171 -Fa 3 (843) 766-1178 ° www.gel.com Chain of Custody and Supporting Documentation 4

Health Physics Procedure ,/4Lh2~ 'A GPP-GGGR-R5]

04-003 -Attach ment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 1 Major 1W' ~ *- s- , -Chain of Custody Form No. 2006-00380 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested LabUse. Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones z Priority:

Z 30 D. [] 14 D. Li 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0009-016F 5/15/06 13:28 SE C BP x x Transferred from COC 2006-00352 9106-0009-016FS 5/15/06 13:28 SE C BP X X Transferred from COC 2006-00352 , 9106-0009-017F 5/15/06 14:03 SE C BP X X Transferred from COC 2006-00352 9106-0009-01 IF 5/15/06 08:05 SE C BP x Transferred from COC 2006-00351 O 9106-0009-013F 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 9106-0009-013FS 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 D17 9106-0009-014F 5/15/06 08:59 SE C BP X Transferred from COC 2006-00351 SA 9106-0009-015F 5/15/06 09:36 SE C BP x x Transferred from COC 2006-00351 C NOTES: PO #: 002332 MSR #: 06-0S/1 SSWP# NA Z LTP QA[] Radwaste QA[] Non QA 1) Relinquisled By Date/Time

2) Rec v d y Date/Time 3) Relinquished By Date/Time
4) Reteivelt By Date/Time Samples Shipped Via: Z Fed Ex L] ups ni Hand E] Other Bill of Lading #2gu -?-T Internal Container Temp.: __ Deg. C Custody Sealed?YE NO Custody Seal Intact?YE Nn Health Physics Procedure 1ýtj W__1 GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00381 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories

<2040 Savage Road. Charleston SC. 29407 C <;843 556 8171. Attn. Cheryl Jones & ý5 z Priority:

E 30 D. [:114 D. [:E7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0009-00 1F 5/11/06 13:22 SE C BP x x Transferred from COC 2006-00347 6 9106-0009-002F 5/11/06 13:46 SE C BP X X Transferred from COC 2006-00347 DI 9106-0009-003F 5/11/06 14:06 SE C BP X X Transferred from COC 2006-00347 t 9106-0009-004F 5/11/06 14:30 SE C BP X X Transferred from COC 2006-00347 1I 9106-0009-005F 5/11/06 14:55 SE C BP X X Transferred from COC 2006-00347 lj 9106-0009-007F 5/12/06 07:44 SE C BP X X Transferred from COC 2006-00348

! 9106-0009-008F 5/12/06 08:16 SE C BP X X Transferred from COC 2006-00348 (4 9106-0009-009F 5/12/06 08:35 SE C BP X X Transferred from COC 2006-00348 9106-0009-01OF 5/12/06 09:07 SE C BP X X Transferred from COC 2006-00348 01 04 0 NOTES: PO #: 002332 MSR #: 06-SSWP#NA Z LTPQA ED Radwaste QA El Non QA 1) Relinquished By Date/Time

2) Rec *ey Date/Time 3) Reiqis c By1- Dat/:ime 401 r6 3) Relinquished By Date/Time
4) Received y DatefTime Samples Shipped Via: N Fed Ex QI uPs MI Hand LI Other Bill of Lading #3qtt lyf5. Z,5T Internal Container Temp.: _- Deg. C Custody Sealed?YE] NE Custody Seal Intact?YE0 NE1 Ijp qL614Z Z C~ IV146 Sly,51 c40o Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-0OOI Figure 1. Samj Date/Time Received:

--0 SDG#: MS ()4 O( 0 0 1 Work Order Number: Shipping C ohtainer ID:_._,, _- _t, _- __, __I. Custody Seals. ori shipping container intact?2. Custody Seals dated and signed?3. Chain-of-Custo¶Iy record present?4. Cooler temperature 6O, 5. Vermiculite/packing materials is: 6.: -Number of samples in shipping container:

7. Sample holding times exceeded?pie Check*in List eq o Chain of Custody A. il Yes I No [ I Yes[ ].No N Yes No [ ]Wet [ Dry Yes [X4 No [1 10. Were any anomalies identified in sample receipt? Yes [ No I 1.. ,Description of anomalies,(include sample numbers): Sample Custodian/Laboratory: , Datew _ G -1 'Telephoned to: -On By It, 7 RADIOLOGICAL ANALYSIS 8 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 164542 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 542293 537131 537124 Sample ID 164542016 164542017 1201121832 1201121833 1201121834 1201121835 Client ID 9106-0009-01 IF 9106-0009-014F Method Blank (MB)165557001(1000-0000-119-C-i C-01) Sample Duplicate (DUP)165557001(1000-0000-119-C-iC-01)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

9 Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 165557001 (1000-0000-119-C-IC-01).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments The Cm-233/234 blank result is greater than the MDA but less than the detection limit.Qualifier information Manual qualifiers were not required.Method/Analysis Information 10 Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: Prep Method: DOE EML HASL-300, Pu- 11-RC Modified Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 542294 537131 537124 Sample ID 164542016 164542017 1201121836 1201121837 1201121838 1201121839 Client ID 9106-0009-01 IF 9106-0009-014F Method Blank (MB)165557001(1000-0000-119-C-i C-01) Sample Duplicate (DUP)165557001(1000-0000-119-C-i C-01) Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 165557001 (1000-0000-119-C-IC-01).

QC Information All of the QC samples met the required acceptance limits.11 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu-1 1-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 542295 537131 537124 12 Sample ID Client ID 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201121840 Method Blank (MB)1201121841 165557001(1000-0000-119-C-1C-01)

Sample Duplicate (DUP)1201121842 165557001(1000-0000-119-C-IC-01)

Matrix Spike (MS)1201121843 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 165557001 (1000-0000-119-C-1C-01).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 13 referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 164542001 164542002 164542003 164542004 164542005 164542006 164542007 164542008 164542009 164542010 164542011 164542012 164542013 164542014 164542015 164542016 164542017 1201111185 1201111186 1201111187 EML HASL 300,4.5.2.3 Dry Soil Prep 537866 537124 Client ID 9106-0009-016F 9106-0009-016FS 9106-0009-017F 9106-0009-013F 9106-0009-013FS 9106-0009-015F 9106-0009-OOIF 9106-0009-002F 9106-0009-003F 9106-0009-004F 9106-0009-005F 9106-0009-007F 9106-0009-008F 9106-0009-009F 9106-0009-01 OF 9106-0009-01 IF 9106-0009-014F Method Blank (MB)164542001(9106-0009-016F)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)14 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 164542001 (9106-0009-016F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 164542003 (9106-0009-017F) and 164542008 (9106-0009-002F) were recounted due to high MDAs.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments The sample and the duplicate, 1201111186 (9106-0009-016F) and 164542001 (9106-0009-016F), did not meet the relative percent difference requirement for Co-60. However, they do meet the relative error ratio requirement with a value of 1.7.15 Qualifier information Qualifier UI Reason Data rejected due to high peak-width.

Data rejected due to interference.

Data rejected due to low abundance.

UI UI Analyte Sample Bismuth-212 164542013 Cesium- 134 164542008 Cesium-137 164542009 Europium-155 164542009 Bismuth-214 164542008 164542015 Cesium-134 164542003 164542007 Cobalt-60 164542004 Manganese-54 164542010 Potassium-40 1201111185 Cesium-134 164542002 164542004 164542005 164542016 1201111186 Niobium-94 164542005 UI UI data rejected due to high peak width data rejected due to low abundance Method/Analysis Information Product: Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: GFPC, Sr90, solid-ALL FSS EPA 905.0 Modified Ash Soil Prep Dry Soil Prep 541208 537131 537124 16 Sample ID Client ID 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201119317 Method Blank (MB)1201119318 164551004(9106-0002-019F)

Sample Duplicate (DUP)1201119319 164551004(9106-0002-019F)

Matrix Spike (MS)1201119320 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 164551004 (9106-0002-019F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.17 Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS DOE EML HASL-300, Tc-02-RC Modified Analytical Method: Analytical Batch Number: 540445 Sample ID 164542016 164542017 1201117552 1201117553 1201117554 1201117555 Client ID 9106-0009-01 IF 9106-0009-014F Method Blank (MB)165011005(1000-0000-125-C-i C-01) Sample Duplicate (DUP)165011005(1000-0000-125-C-i C-01) Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

18 Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 165011005 (1000-0000-125-C-1C-01).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-i, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 538969 Prep Batch Number: 537131 Dry Soil Prep GL-RAD-A-021 Batch Number: 537124 19 Sample ID Client ID 164542016 9106-0009-01 IF 164542017 9106-0009-014F 1201113887 Method Blank (MB)1201113888 163741008(9106-0008-007F)

Sample Duplicate (DUP)1201113889 163741008(9106-0008-007F)

Matrix Spike (MS)1201113890 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 163741008 (9106-0008-007F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

20 Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Liquid Scint Ni63, Solid-ALL FSS DOE RESL Ni-1, Modified Ash Soil Prep Dry Soil Prep 541424 537131 537124 21 Sample ID 164542001 164542002 164542003 164542004 164542005 164542006 164542007 164542008 164542009 164542010 164542011 164542012 164542013 164542014 164542015 164542016 164542017 1201119883 1201119884 1201119885 1201119886 Client ID 9106-0009-016F 9106-0009-016FS 9106-0009-017F 9106-0009-013F 9106-0009-013FS 9106-0009-015F 9106-0009-001F 9106-0009-002F 9106-0009-003F 9106-0009-004F 9106-0009-005F 9106-0009-007F 9106-0009-008F 9106-0009-009F 9106-0009-01OF 9106-0009-01 IF 9106-0009-014F Method Blank (MB)164542011(9106-0009-005F)

Sample Duplicate (DUP)164542011(9106-0009-005F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 164542011 (9106-0009-005F).

QC Information All of the QC samples met the required acceptance limits.22 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: Analytical Batch Number: Sample ID 164542016 164542017 1201122404 1201122405 1201122406 1201122407 EPA 906.0 Modified 542573 Client ID 9106-0009-01 IF 9106-0009-014F Method Blank (MB)165702005(9106-0011-009F)

Sample Duplicate (DUP)165702005(9106-0011-009F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.23 Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 165702005 (9106-0011-009F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 24 Product: Liquid Scint C14, Solid AII,FSS EPA EERF C-01 Modified Analytical Method: Analytical Batch Number: 545141 Sample ID 164542016 164542017 1201128388 1201128389 1201128390 1201128391 Client ID 9106-0009-01 IF 9106-0009-014F Method Blank (MB)165011012(1000-0000-120-C-I C-02) Sample Duplicate (DUP)165011012(1000-0000-120-C-i C-02) Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 165011012 (1000-0000-120-C-1C-02).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.25 Sample Re-prep/Re-analysis Samples were reprepped due to low/high recovery.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

., 7/1//26 SAMPLE DATA

SUMMARY

27 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-0818 GEL Work Order: 164542 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 28 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result 9106-0009-016F 164542001 SE 15-MAY-06 08-JUN-06 Client 32.9%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-2 4 1 U Bismuth-212 Bismuth-214 0.865 0.0409 0.562 0.556 Cesium-134 L Cesium- 137 Cobalt-60 Europium-152 t Europium-154 L Europium-155 L Lead-212 Lead-214 Manganese-54 t Niobium-94 L Potassium-40 Radium-226 Silver-108m L Thallium-208 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 L J 0.0263 0.170 0.239 J 0.0167 J -0.0172 J 0.0597 0.938 0.688 0.0262-0.00291 14.4 0.556 1 -0.00368 0.327 Uncertainty

+/-0.203+/-0.0866+/-0.221+/-0.116+/-0.0382+/-0.0433+/-0.0465+/-0.0586+/-0.0755+/-0.0887+/-0.0991+/-0.114+/-0.025+/-0.0206+/-1.33+/-0.116+/-0.0205+/-0.0551 0.0598 0.0774 0.149 0.0341 0.0263 0.0185 0.0197 0.0506 0.0623 0.0526 0.0287 0.0321 0.0225 0.0173 0.169 0.0341 0.0169 0.0182+/-0.203+/-0.0866+/-0.221+/-0.116+/-0.0382+/-0.0433+/-0.0465+/-0.0586+/-0.0755+/-0.0887+/-0.0991+/-0.114+/-0.025+/-0.0206+/- 1.33+/-0.116+/-0.0205+1-0.0551 0.129 0.159 0.315 0.072 0.0553 0.0392 0.0428 0.105 0.134 0.108 0.0594 0.0672 0.0474 0.0366 0.372 0.072 0.0355 0.0384 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/26/06 1925 537866 1 SLNl 07/06/06 0552 541424 2 LC TPU MDA Units DF Analyst Date Time Batch Mtd-6.3 +/-8.63 7.41 +/-8.63 15.2 pCi/g The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description Analyst Date Time Prep Batch AXP2 06/08/06 1335 537124 1 2 EML HASL 300, 4.5.2.3 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 29 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-016F Project: YANKO 1204 Sample ID: 164542001 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 93 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.30 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-016FS 164542002 SE 15-MAY-06 08-JUN-06 Client 26.7%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.878 Americium-241 U -0.0346 Bismuth-212 0.587 Bismuth-214 0.544 Cesium-134 UI 0.00 Cesium-137 0.231 Cobalt-60 0.277 Europium-152 U 0.0343 Europium-154 U -0.031 Europium-155 U 0.0255 Lead-212 0.856 Lead-214 0.647 Manganese-54 U 0.0155 Niobium-94 U -0.00637 Potassium-40 13.0 Radium-226 0.544 Silver-108m U 0.0129 Thallium-208 0.285 Rad Liquid Scintillation Analysis+/-0.189+/-0.106+/-0.254+/-0.0981+/-0.0439+/-0.0415+/-0.061+/-0.0509+/-0.0614+/-0.0856+/-0.0896+1-0.105+/-0.0227+/-0.0187+/-1.25+/-0.0981+/-0.0157+/-0.0473 0.0564 0.081 0.137 0.0327 0.0244 0.0159 0.0187 0.0443 0.0487 0.0484 0.0244 0.0294 0.0199 0.0154 0.163 0.0327 0.0161 0.0177+/-0.189+/-0.106+/-0.254+/-0.0981+/-0.0439+/-0.0415+/-0.061+/-0.0509+/-0.0614+/-0.0856+/-0.0896+/-0.105+/-0.0227+/-0.0187+/-1.25+/-0.0981+/-0.0157+/-0.0473 0.122 0.168 0.292 0.0692 0.0514 0.0339 0.0409 0.0928 0.107 0.100 0.0508 0.0619 0.0423 0.0327 0.361 0.0692 0.0337 0.0374 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/26/06 1925 537866 1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -11.8 +/-9.16 8.00 +/-9.17 16.4 pCi/g SLNI 07/06/06 0614 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 88 (25/-,125%)

31 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-016FS Proiect: YANKO 1204 Sample ID: 164542002 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.32 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analvwiv..........

"-r ....... T Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-017F 164542003 SE 15-MAY-06 08-JUN-06 Client 28.8%Proiect: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.965 Americium-241 U 0.0107 Bismuth-212 0.823 Bismuth-214 0.590 Cesium-134 U! 0.00 Cesium-137 0.388 Cobalt-60 0.537 Europium-152 U -0.0211 Europium-154 U -0.00189 Europium-155 U 0.0848 Lead-212 0.899 Lead-214 0.693 Manganese-54 U 0.00193 Niobium-94 U -0.00651 Potassium-40 14.0 Radium-226 0.590 Silver-108m U 0.0213 Thallium-208 0.289 Rad Liquid Scintillation Analysis+/-0.265+/-0.0295+/-0.358+/-0.108+/-0.0622+/-0.0535+/-0.0744+/-0.062+/-0.0847+/-0.0505+/-0.0714+/-0.112+/-0.0296+/-0.0298+/-1.07+/-0.108+/-0.0214+/-0.0556 0.082 0.0256 0.173 0.0387 0.0311 0.0225 0.0246 0.0502 0.0701 0.0451 0.0289 0.0345 0.0244 0.0212 0.158 0.0387 0.0198 0.0197+/-0.265+/-0.0295+/-0.358+/-0.108+/-0.0622+/-0.0535+/-0.0744+/-0.062+/-0.0847+1-0.0505+/-0.0714+/-0.112+/-0.0296+/-0.0298+/-1.07+/-0.108+/-0.0214+/-0.0556 0.176 0.0529 0.370 0.0823 0.0659 0.048 0.0541 0.106 0.153 0.0933 0.0602 0.0728 0.0522 0.0451 0.365 0.0823 0.0416 0.0421 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/06/06 1801 537866 1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -5.48 +/-9.76 8.34 +/-9.76 17.1 pCi/g SLNl 07/06/06 0635 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 90 (25%-125%)

33 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Project: YANK01204 Sample ID: 164542003 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.34 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10,'2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-013F 164542004 SE 15-MAY-06 08-JUN-06 Client 24.5%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 UI Cesium-137 U Cobalt-60 UI Europium-152 U Europium-154 U -Europium-155 U Lead-2 12 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.878-0.047 0.870 0.579 0.00 0.0285 0.00 0.0122-0.00728 0.0493 0.976 0.708-0.0103 0.0208 14.9 0.579 0.00488 0.318+/-0.180+/-0.0919+/-0.329+/-0.0876+/-0.0372+/-0.0289+/-0.0348+/-0.0578+/-0.0629+/-0.0549+/-0.0702+/-0.0991+/-0.0211+/-0.0204+/-0.995+/-0.0876+/-0.0196+/-0.0428 0.0626 0.0775 0.135 0.0328 0.0246 0.0185 0.0197 0.0497 0.0533 0.0521 0.0313 0.0337 0.0171 0.0187 0.211 0.0328 0.0161 0.0166+/-0.180+/-0.0919+/-0.329+/-0.0876+/-0.0372+/-0.0289+/-0.0348+/-0.0578+/-0.0629+/-0.0549+/-0.0702+/-0.0991+/-0.0211+/-0.0204+/-0.995+/-0.0876+/-0.0196+/-0.0428 0.135 0.160 0.288 0.0695 0.0519 0.0392 0.0429 0.104 0.116 0.107 0.0645 0.0705 0.0367 0.0394 0.457 0.0695 0.0338 0.0354 15.8 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/26/06 1925 537866 1 SLNI 07/06/06 0657 541424 2-3.87 +/-9.05 7.70 +/-9.05 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 DOE RESL Ni-l, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 90 (25%-125%)

35 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certifieate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: 9106-0009-013F 164542004 Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.36 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-013FS 164542005 SE 15-MAY-06 08-JUN-06 Client 25.5%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 UI Cesium- 137 U Cobalt-60 U Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 UI Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Liquid Scintillation Analysis 1.08-0.0339 0.626 0.787 0.00 0.0462-0.0278-0.0132 0.0371 0.145 1.13 0.940 0.00369 0.00 18.6 0.787 0.0214 0.370+/-0.247+/-0.120+/-0.363+/-0.144+/-0.0439+1-0.0552+/-0.0303+/-0.0736+/-0.0932+/-0.113+/-0.128+/-0.149+/-0.0305+/-0.0696+/-1.66+/-0.144+/-0.0237+/-0.0703 0.0754 0.0907 0.200 0.0454 0.0285 0.0241 0.0217 0.0615 0.0794 0.0744 0.0357 0.045 0.026 0.019 0.206 0.0454 0.021 0.0216+/-0.247+/-0.120+/-0.363+/-0.144+/-0.0439+/-0.0552+/-0.0303+/-0.0736+/-0.0932+/-0.113+/-0.128+/-0.149+/-0.0305+/-0.0696+/-1.66+/-0.144+/-0.0237+/-0.0703 0.164 0.188 0.426 0.0963 0.0608 0.0514 0.0482 0.130 0.172 0.154 0.0747 0.0947 0.0556 0.0409 0.459 0.0963 0.0445 0.0463 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/26/06 1926 537866 1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -9.09 +/-8.91 7.72 +/-8.91 15.8 pCi/g SLNI 07/06/06 0754 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description I EML FIASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 89 (25%-125%)

37 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Sample ID: Qualifier Result Uncertainty 9106-0009-013FS Proiect: YANKO 1204 164542005 Client ID: YANKOO Vol. Recv.: LC TPU MDA Units DF Analyst Date Time Batch Mtd Parameter Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.38 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-015F 164542006 SE 15-MAY-06 08-JUN-06 Client 29.5%Project: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 0.750 Americium-241 U 0.0322 Bismuth-212 0.554 Bismuth-214 0.469 Cesium-134 U 0.0282 Cesium-137 0.186 Cobalt-60 0.334 Europium-152 U -0.0216 Europium-154 U -0.0217 Europium-155 U 0.0396 Lead-212 0.872 Lead-214 0.602 Manganese-54 U 0.0235 Niobium-94 U -0.00451 Potassium-40 12.8 Radium-226 0.469 Silver-108m U -0.0106 Thallium-208 0.282 Rad Liquid Scintillation Analysis+/-0.165+/-0.123+/-0.339+/-0.0923+/-0.0277+/-0.0599+/-0.0531+/-0.0531+/-0.0697+/-0.0659+/-0.0677+/-0.103+/-0.0254+/-0.0206+/-0.916+/-0.0923+/-0.0194+/-0.0509 0.069 0.0837 0.154 0.0348 0.0257 0.0185 0.0185 0.0465 0.0571 0.0536 0.0275 0.034 0.0229 0.0172 0.172 0.0348 0.0165 0.0187+/-0.165+/-0.123+/-0.339+/-0.0923+/-0.0277+/-0.0599+/-0.0531+/-0.0531+/-0.0697+/-0.0659+/-0.0677+/-0.103+/-0.0254+/-0.0206+/-0.916+/-0.0923+/-0.0194+/-0.0509 0.149 0.173 0.328 0.0741 0.0545 0.0397 0.0412 0.098 0.125 0.111 0.0573 0.0716 0.0488 0.0367 0.385 0.0741 0.035 0.0398 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/26/06 1926 537866 1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -8.35 +/-12.6 10.8 +/-12.6 22.2 SLN1 07/06/06 0816 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description I EML HIASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 72 (25%-125%)

39 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-015F Project: YANK0 1204 Sample ID: 164542006 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.40 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-00IF 164542007 SE 1 I-MAY-06 08-JUN-06 Client 38.7%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Rad Liquid Scintillation Analysis FSS 0.947 U -0.0496 0.584 0.642 UI 0.00 0.165 0.118 U -0.0188 U -0.013 U 0.052 1.04 0.766 U 0.0113 U 0.0108 15.6 0.642 U 0.0094 0.375+/-0.162+/-0.0955+/-0.331+/-0.110+/-0.0515+/-0.0351+/-0.0475+/-0.0592+/-0.0795+/-0.0744+/-0.0711+/-0.0898+/-0.0265+/-0.0212+/-1.05+/-0.110+/-0.0195+/-0.056 0.0626 0.0742 0.146 0.0346 0.0279 0.0181 0.0219 0.0474 0.0666 0.0472 0.0275 0.0323 0.0228 0.0185 0.164 0.0346 0.0174 0.0164+/-0.162+/-0.0955+/-0.331+/-0.110+/-0.0515+/-0.0351+/-0.0475+/-0.0592+/-0.0795+/-0.0744+/-0.0711+/-0.0898+/-0.0265+/-0.0212+/-1.05+/-0.110+/-0.0195+/-0.056 0.136 0.153 0.313 0.0734 0.0589 0.0387 0.048 0.0995 0.144 0.0979 0.0571 0.0681 0.0485 0.0393 0.369 0.0734 0.0366 0.0353 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/26/06 2131 537866 1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -1.97 +/-9.30 7.86 +/-9.30 16.1 pCi/g SLNI 07/06/06 0837 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1335 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 97 (25%-125%)

41 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-001F Project: YANK01204 Sample ID: 164542007 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.42 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-002F 164542008 SE 1 I-MAY-06 08-JUN-06 Client 36.1%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Ut Cesium-134 UI Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.933 0.0584 0.963 0.00 0.00 0.527 0.904-0.00341 0.0363 0.00509 1.04 0.872-0.00711 0.0283 15.1 0.864 0.0067 0.313+/-0.325+1-0.0515+/-0.481+/-0.157+/-0.090+/-0.0887+/-0.124+/-0.0841+/-0.117+/-0.0767+/-0.102+/-0.160+/-0.0458+/-0.0342+/-1.36+/-0.157+/-0.0301+/-0.0898 0.132 0.0426 0.261 0.122 0.0391 0.0329 0.0357 0.0727 0.101 0.0659 0.0392 0.0543 0.0369 0.0302 0.285 0.0544 0.0261 0.0353+/-0.325+/-0.0515+/-0.481+/-0.157+/-0.090+/-0.0887+/-0.124+/-0.0841+/-0.117+/-0.0767+/-0.102+/-0.160+/-0.0458+/-0.0342+/-1.36+/-0.157+/-0.0301+/-0.0898 0.282 0.0878 0.558 0.252 0.0836 0.070 0.0783 0.153 0.220 0.136 0.0819 0.114 0.0789 0.0643 0.638 0.116 0.0551 0.0748 17.6 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/06/06 1801 537866 1 SLN1 07/06/06 0859 541424 2 12 +/-9.86 8.60 +/-9.87 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Carrier/Tracer Recovery Test Recovery%

Acceptable Limits Liquid Scint Ni63, Solid-ALL FS 86 (25%-I125%)

43 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Proiect: YANK01204 Sample ID: 164542008 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.U! Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.44 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analyvis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-003F 164542009 SE I I-MAY-06 08-JUN-06 Client 46.6%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 UI Cobalt-60 U Europium-152 U -Europium-154 U Europium-155 UI Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Liquid Scintillation Analysis 0.831-0.0139 0.915 0.479 0.051 0.00 0.0152-0.00268-0.0552 0.00 0.989 0.777 0.0118-0.0184 13.5 0.479-0.0159 0.320+/-0.208+/-0.109+/-0.395+/-0.140+/-0.0395+/-0.0699+/-0.0258+/-0.0629+/-0.0912+/-0.154+/-0.112+/-0.126+/-0.0292+/-0.0231+/-1.42+/-0.140+/-0.0225+/-0.0617 0.0672 0.0816 0.154 0.0406 0.0275 0.0204 0.0228 0.052 0.0716 0.0554 0.0314 0.0373 0.0248 0.0181 0.214 0.0406 0.0174 0.0201+/-0.208+/-0.109+/-0.395+/-0.140+/-0.0395+/-0.0699+/-0.0258+/-0.0629+/-0.0912+/-0.154+/-0.112+/-0.126+/-0.0292+/-0.0231+/-1.42+/-0.140+/-0.0225+/-0.0617 0.146 0.168 0.330 0.0859 0.0583 0.0434 0.0499 0.109 0.155 0.115 0.0653 0.0784 0.0528 0.0385 0.472 0.0859 0.0368 0.0428 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/26/062131 537866 1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -7.67 +/-9.42 8.11 +/-9.42 16.6 pCi/g SLNI 07/06/06 0920 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 84 (25%-125%)

45 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-003F Proiect: YANKO 1204 Sample ID: 164542009 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.46 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analwviq Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result 9106-0009-004F 164542010 SE 11-MAY-06 08-JUN-06 Client 39.7%Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.627 Americium-241 U -0.0965 Bismuth-212 0.708 Bismuth-214 0.564 Cesium-134 U 0.00218 Cesium-137 U -0.00566 Cobalt-60 U 0.0199 Europium-152 U 0.0303 Europium-154 U 0.0292 Europium-155 U 0.0584 Lead-212 0.641 Lead-214 0.603 Manganese-54 UI 0.00 Niobium-94 U-0.000263 Potassium-40 12.7 Radium-226 0.564 Silver-108m U-0.000165 Thallium-208 0.204 Rad Liquid Scintillation Analysis Uncertainty

+/-0.164+/-0.143+/-0.249+/-0.084+/-0.0433+/-0.0197+/-0.026+/-0.0491+/-0.0621+/-0.0685+/-0.0581+/-0.0845+/-0.0295+/-0.018+/-0.870+/-0.084+/-0.0166+/-0.044 LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.0613 0.0901 0.136 0.027 0.0201 0.0162 0.0211 0.0422 0.0547 0.0477 0.0256 0.031 0.0141 0.0151 0.127 0.027 0.0145 0.0167+/-0.164+/-0.143+/-0.249+/-0.084+/-0.0433+/-0.0197+/-0.026+/-0.0491+/-0.0621+/-0.0685+/-0.0581+/-0.0845+/-0.0295+/-0.018+/-0.870+/-0.084+/-0.0166+/-0.044 0.132 0.187 0.290 0.0576 0.0428 0.0346 0.0457 0.0887 0.119 0.0988 0.0533 0.065 0.0308 0.0321 0.290 0.0576 0.0306 0.0355 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/26/06 2132 537866 1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -2.23 +/-9.09 7.69 +/-9.10 15.8 SLNI 07/06/06 0942 541424 2 The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-l, Modified Analyst Date Time Prep Batch AXP2 06/08/06 1336 537124 Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 87 (25/,- 25%)47 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-004F Project: YANK01204 Sample ID: 164542010 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.48 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: 9106-0009-005F Project: YANK01204 Sample ID: 164542011 Client ID: YANKOO Matrix: SE Vol. Recv.: Collect Date: 11-MAY-06 Receive Date: 08-JUN-06 Collector:

Client Moisture:

37.8%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U -Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.810-0.0635 0.572 0.563 0.00 0.191 0.106 0.0201 0.0417 0.0655 0.847 0.593 0.0171 0.00235 12.5 0.563 0.00649 0.259+/-0.177+/-0.0844+/-0.216+/-0.0915+/-0.0319+/-0.0424+/-0.0417+/-0.0463+/-0.0763+/-0.0642+/-0.0862+/-0.090+/-0.0157+/-0.0154+/-1.17+/-0.0915+/-0.0144+/-0.0444 0.0514 0.0694 0.118 0.0261 0.0209 0.0143 0.0169 0.0396 0.0437 0.0423 0.0217 0.026 0.0135 0.0129 0.107 0.0261 0.013 0.0143+/-0.177+/-0.0844+/-0.216+/-0.0915+/-0.0319+/-0.0424+/-0.0417+/-0.0463+/-0.0763+/-0.0642+/-0.0862+/-0.090+/-0.0157+/-0.0154+/-1.17+/-0.0915+/-0.0144+/-0.0444 0.110 0.143 0.251 0.0552 0.0438 0.0303 0.0366 0.0825 0.0949 0.0871 0.0449 0.0544 0.0289 0.0273 0.242 0.0552 0.0273 0.0302 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/26/06 2352 537866 1 SLN1 07/06/06 1003 541424 2-13 +/-9.02 7.92 +/-9.03 16.3 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 49 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-005F Proiect: YANKO 1204 Sample ID: 164542011 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 93 (25%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.50 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Ci-rtifirntP nf A n2lv-ii Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-007F 164542012 SE 12-MAY-06 08-JUN-06 Client 26.7%Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U -Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Liquid Scintillation Analysis 0.843 0.0298 0.329 0.499 0.00886 0.103 0.0671 0.0806 0.020 0.0584 0.752 0.660 0.0129-0.00677 12.7 0.499 0.00329 0.272+/-0.157+/-0.0903+/-0.305+/-0.102+/-0.0266+/-0.048+/-0.0364+/-0.0694+/-0.0702+/-0.0521+/-0.0686+/-0.0977+/-0.0245+/-0.0196+/-0.968+/-0.102+/-0.0197+/-0.0473 0.060 0.0777 0.137 0.0344 0.0231 0.0176 0.0187 0.0476 0.0617 0.0494 0.0291 0.0328 0.0215 0.0163 0.139 0.0344 0.0165 0.0175+/-0.157+/-0.0903+/-0.305+/-0.102+/-0.0266+/-0.048+/-0.0364+/-0.0694+/-0.0702+/-0.0521+/-0.0686+/-0.0977+/-0.0245+/-0.0196+/-0.968+/-0.102+/-0.0197+/-0.0473 0.130 0.160 0.294 0.0728 0.049 0.0376 0.0413 0.0998 0.134 0.102 0.0602 0.0689 0.0457 0.0348 0.316 0.0728 0.0347 0.0372 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/26/06 2132 537866 1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -13.6 +/-9.31 8.18 +/-9.32 16.8 pCi/g SLNI 07/06/06 1025 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-l, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 87 (25 %r-125%)51 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-007F Project: YANKO 1204 Sample ID: 164542012 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.52 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-008F 164542013 SE 12-MAY-06 08-JUN-06 Client 21%Proiect: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 0.400 Americium-241 U 0.0209 Bismuth-212 UI 0.00 Bismuth-214 0.384 Cesium-134 U 0.0266 Cesium-137 U 0.0372 Cobalt-60 U 0.0483 Europium-152 U -0.0559 Europium-154 U 0.014 Europium-155 U 0.00754 Lead-212 0.624 Lead-214 0.362 Manganese-54 U 0.00129 Niobium-94 U -0.0174 Potassium-40 10.5 Radium-226 0.384 Silver-108m U 0.0113 Thallium-208 0.160 Rad Liquid Scintillation Analysis+/-0.170+/-0.089+/-0.369+/-0.0728+/-0.0264+/-0.0247+/-0.0265+/-0.0623+/-0.0855+/-0.062+/-0.0725+/-0.0776+/-0.0255+/-0.0227+/-1.01+/-0.0728+/-0.018+/-0.0447 0.0803 0.085 0.166 0.0346 0.0252 0.0193 0.0275 0.0511 0.0647 0.0566 0.031 0.0329 0.0219 0.0182 0.184 0.0346 0.0181 0.0201+/-0.170+/-0.089+/-0.369+/-0.0728+/-0.0264+/-0.0247+/-0.0265+/-0.0623+/-0.0855+/-0.062+/-0.0725+/-0.0776+/-0.0255+/-0.0227+/-1.01+/-0.0728+/-0.018+/-0.0447 0.176 0.178 0.361 0.0753 0.0548 0.0422 0.0607 0.109 0.145 0.118 0.0652 0.0708 0.0479 0.0396 0.425 0.0753 0.0389 0.0436 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/26/06 2132 537866 1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -12.9 +/-9.03 7.92 +/-9.04 16.3 pCi/g SLN1 07/06/06 1046 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 90 (25%-/125%)

53 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-008F Project: YANK01204 Sample ID: 164542013 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.54 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis I I I r I Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-009F 164542014 SE 12-MAY-06 08-JUN-06 Client 31.2%Proiect: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Liquid Scintillation Analysis 0.760 0.0365 0.474 0.563 0.00 0.397 0.458 0.00306-0.0266 0.0544 0.817 0.630 0.0157 0.00147 13.2 0.563 0.0022 0.236+/-0.142+/-0.0489+/-0.180+/-0.080+/-0.0352+/-0.0495+/-0.0512+/-0.033+/-0.0415+/-0.0564+/-0.0755+/-0.0768+/-0.0198+/-0.0115+/-0.946+/-0.080+/-0.0118+/-0.0379 0.0393 0.0459 0.081 0.0203 0.015 0.0113 0.0108 0.0293 0.033 0.0349 0.018 0.0202 0.0108 0.0102 0.0857 0.0203 0.0103 0.0112+/-0.142+/-0.0489+/-0.180+/-0.080+/-0.0352+/-0.0495+/-0.0512+/-0.033+/-0.0415+/-0.0564+/-0.0755+/-0.0768+/-0.0198+/-0.0115+/-0.946+/-0.080+/-0.0118+/-0.0379 0.0821 0.0937 0.169 0.0422 0.0311 0.0235 0.0229 0.0605 0.0695 0.0715 0.037 0.0418 0.0227 0.0211 0.184 0.0422 0.0213 0.0233 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 06/26/06 2358 537866 1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -7.24 +/-8.52 7.35 +/-8.53 15.1 pCi/g SLNI 07/06/06 1108 541424 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 94 (25%-125%)

55 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-009F Proiect: YANKO 1204 Sample ID: 164542014 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.56 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-01 OF 164542015 SE 12-MAY-06 08-JUN-06 Client 24.2%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 U Bismuth-214 UI Cesium-134 U Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.886 0.0401 0.345 0.00 0.0774 0.156 0.153 0.00473 0.117 0.0356 0.640 0.528 0.0199-0.0113 12.5 0.527-0.00285 0.170+/-0.280+/-0.0443+/-0.308+/-0.117+/-0.0559+/-0.0589+/-0.0827+/-0.0824+/-0.161+/-0.0726+/-0.0741+/-0.123+/-0.0374+/-0.031+/-1.19+/-0.117+/-0.0268+/-0.0791 0.109 0.0427 0.216 0.104 0.0375 0.0307 0.0293 0.073 0.104 0.0668 0.0404 0.0492 0.0335 0.0263 0.255 0.0544 0.023 0.0318+/-0.280+/-0.0443+/-0.308+/-0.117+/-0.0559+/-0.0589+/-0.0827+/-0.0824+/-0.161+/-0.0726+/-0.0741+/-0.123+/-0.0374+/-0.031+/-1.19+/-0.117+/-0.0268+/-0.0791 0.235 0.0881 0.465 0.214 0.0798 0.0654 0.0648 0.153 0.225 0.138 0.0842 0.104 0.0716 0.0562 0.570 0.116 0.0489 0.0673 14.8 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/26/06 2133 537866 1 SLN1 07/06/06 1129 541424 2-4.44 +/-8.42 7.19 +/-8.43 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Carrier/Tracer Recovery Test Recovery%

Acceptable Limits Liquid Scint Ni63, Solid-ALL FS 96 (25%-125%)

57 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-OIOF Proiect: YANK01204 Sample ID: 164542015 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.58 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-011F 164542016 SE 15-MAY-06 08-JUN-06 Client 19.2%Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U Curium-242 U (Curium-243/244 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -(Plutonium-239/240 U Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Gamma Spec Analysis 0.0337 +/-0.0307 0.00634 +/-0.0168 1.39 +/-0.192 0.00784 0.00951 0.00787+/-0.0311+/-0.0168+/-0.268 0.00347 +/-0.015 0.0116 +/-0.015 0.00 +/-0.0142 0.00 +/-0.0142 0.137 +/-0.947 0.914 +/-0.947 Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.638 Americium-241 U 0.0559 Bismuth-212 0.415 Bismuth-214 0.449 Cesium-134 UI 0.00 Cesium-137 U 0.00214 Cobalt-60 U -0.0233 Europium-152 U -0.0189 Europium-154 U -0.0121 Europium-155 U 0.036 Lead-212 0.691 Lead-214 0.473 Manganese-54 U -0.00471 Niobium-94 U 0.00946 Potassium-40 12.5 Radium-226 0.449 Silver-108m U -0.00842 Thallium-208 0.209 Rad Gas Flow Proportional Counting+/-0.158+/-0.064+/-0.242+/-0.087+/-0.0377+/-0.0184+/-0.017+/-0.045+/-0.0562+/-0.0542+/-0.0767+/-0.0774+/-0.017+/-0.0154+/-1.07+/-0.087+/-0.0138+/-0.0433 0.0456 0.0573 0.104 0.0259 0.0191 0.0138 0.0112 0.0394 0.0459 0.051 0.0239 0.0271 0.0145 0.0142 0.124 0.0259 0.0115 0.0129+/-0.158+/-0.064+/-0.242+/-0.087+/-0.0377+/-0.0184+/-0.017+/-0.045+/-0.0562+/-0.0542+/-0.0767+/-0.0774+/-0.017+/-0.0154+/-1.07+/-0.087+/-0.0138+/-0.0433 0.0343 0.0416 0.0344 0.0429 0.0196 1.87 0.0992 0.119 0.224 0.0554 0.0406 0.0297 0.0254 0.083 0.0999 0.106 0.050 0.0572 0.0313 0.0303 0.278 0.0554 0.0246 0.0277 0.0408 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LCW1 06/29/06 1420 542293 1 LCWI 06/28/06 1831 542294 2 LCW1 07/03/06 0815 542295 3 MJHI 06/26/062133 537866 4 BXF1 07/05/06 1218 541208 5 EGDI 07/04/06 2212 542573 6 GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.0 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS 0446 +/-0.0171 0.0187 +/-0.0171 3.69 +/-6.09 4.96 +/-6.09 10.3 pCi/g 59 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: 9106-0009-011F 164542016 Prolect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAllFSS Carbon- 14 U -0.104 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -1.14 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -12.3 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0332 I+/-0.106 0.0938 +/-0.106 0.196+/-17.3 13.2 +/-17.3 27.7 pCi/g pCi/g ATH2 07/07/06 0636 545141 7 SLN1 06/21/06 0918 538969 9 SLNI 07/06/06 1151 541424 10 EGD1 06/25/06 1429 540445 11+/-10.3 8.94 +/-10.3 18.3 pCi/g+/-0.224 0.189 +/-0.224 0.391 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-1, Modified 10 DOE RESL Ni-l, Modified 11 DOE EML HASL-300, Tc-02-RC.Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýGFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS 93 82 86 53 88 87 (15%-125%)

(15%-125%)

(25%-/125%)

(25%- 125%)(15%-125%)

(25%/--125%)

60 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-01 IF Proiect: YANK01204 Sample ID: 164542016 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 80 (15/-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier* QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.61 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-014F 164542017 SE 15-MAY-06 08-JUN-06 Client 19.8%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 0.0409 Curium-242 U 0.00987 Curium-243/244 U 0.00+/-0.0368+/-0.0193+/-0.016 0.00926 0.00 0.00+/-0.0372+/-0.0194+/-0.016 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.(Plutonium-239/240 U 0 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS Actinium-228 Americium-241 U -0 Bismuth-212 Bismuth-214 Cesium-134 U 0 Cesium- 137 Cobalt-60 0 Europium-152 U 0.C Europium-154 U -0 Europium-155 U 0 Lead-212 Lead-214 Manganese-54 U -0.C Niobium-94 U-0.0C Potassium-40 Radium-226 Silver-108m U -0.C Thallium-208 Rad Gas Flow Proportional Counting GFPC, S90, solid-ALL FSS Strontium-90 U -0.Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium Liquid Scint C14, SolidAllFSS

+/-0.035 0.0355 +/-0.035+/-0.0276 0.0227 +/-0.0276+/-0.928 0.894 +/-0.928+/-0.140+/-0.101+/-0.240+/-0.0691+/-0.0188+/-0.0362+/-0.0272+/-0.0405+/-0.0486+/-0.041+/-0.076+/-0.0758+/-0.0156+/-0.0148+/-0.985+/-0.0691+/-0.0128+/-0.037 0.0406 0.0856 0.0907 0.0249 0.0155 0.0124 0.0132 0.0348 0.0402 0.0398 0.0186 0.0237 0.013 0.0111 0.110 0.0249 0.0111 0.0121+/-0.140+/-0.101+/-0.240+/-0.0691+/-0.0188+/-0.0362+/-0.0272+/-0.0405+/-0.0486+/-0.041+/-0.076+/-0.0758+/-0.0156+/-0.0148+/-0.985+/-0.0691+/-0.0128+/-0.037 0.0405 0.0267 0.0221 0.0888 0.0632 1.83 0.0868 0.177 0.192 0.0521 0.0326 0.0262 0.0286 0.0723 0.0862 0.0819 0.0385 0.0495 0.0276 0.0234 0.242 0.0521 0.0232 0.0255 0.0423 10.5 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LCWI 06/29/06 1420 542293 1 LCW1 06/28/06 1831 542294 2 LCW1 07/03/06 0916 542295 3 MJH1 06/26/06 2358 537866 4 BXF1 07/05/06 1218 541208 5 EGD1 07/04/06 2244 542573 6+/-0.0137 0.0197 +/-0.0137 46.9 +/-8.04 5.06 +/-8.08 62 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 10, 2006 Project: YANK01204 Client ID: YANKOOI Vol. Recv.: Client Sample ID: Sample ID: 9106-0009-014F 164542017 Parameter Qualifier Result Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAllFSS Carbon-14 U 0.00873 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 5.21 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -10.4 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0446 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.113 0.0948 +/-0.113+/-16.9 12.5 +/-16.9+/-10.9 9.41 +/-10.9+/-0.211 0.178 +/-0.211 0.198 26.3 pCi/g pCi/g ATH2 07/07/06 0724 545141 7 SLN1 06/21/06 0934 538969 9 SLNI 07/06/06 1212 541424 10 EGD1 06/25/06 1446 540445 11 19.3 pCi/g 0.368 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/08/06 1336 537124 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-0I Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-1, Modified 10 DOE RESL Ni-I, Modified 11 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS 69 101 86 66 91 82 (15%-/125%)

(15%-125%)

(25%-/125%)

(25%-125%)(I5%-125%)

(25%-/125%)

63 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 10, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-014F Project: YANKO1204 Sample ID: 164542017 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 83 (15%- 125%)Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL; MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.64 I QUALITY CONTROL DATA 65 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client : Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: July 10, 2006 Page 1 of 9 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

164542 Parmname NOM Samnle Ouial tIC tJnit~ RPD% RF.C%Ranf'e Anist Date Time Parmname NOM Samnle Oual OC Units RRPD% REC%Rad Alpha Spec Batch 542293 QC1201121833 Americium-241 Curium-242 Curium-243/244 QCI201121835 Americium-241 Curium-242 Curium-243/244 QC1201121832 Americium-241 165557001 DUP U 0.0069 Uncert: +/-0.013 TPU: +/-0.013 U 0.00685 Uncert: +/-0.0134 TPU: +/-0.0135 U 0.00332 Uncert: +/-0.0132 TPU: +/-0.0132 LCS MB 2.68 Uncert: TPU: Uncert: TPU: 3.26 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 0.0442+/-0.0412+/-0.0417 U -0.00258+/-0.0217+/-0.0217 U 0.0176+/-0.0282+/-0.0283 2.84+/-0.266+/-0.426 U 0.00+/-0.0129+/-0.0129 3.05+/-0.276+/-0.452 U 0.0049+/-0.0157+/-0.0157 U 0.00+/-0.0141+/-0.0141 0.0424+/-0.034+/-0.0343 pCi/g 146 pCi/g 442 pCi/g 137 pCi/g" Curium-242 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (0%- 100%) LCWI 06/29/06 14:20 (0%- 100%)(0%- 100%)106 (75%-125%)

94 (75%-125%)

Curium-243/244 QC1201121834 165557001 MS Americium-241 Curium-242 Curium-243/244 2.73 U 0.0069 Uncerl: +/-0.013 TPU: +/-0.013 U 0.00685 Uncert: +/-0.0134 TPU: +/-0.0135 3.33 U 0.00332 Uncert: +/-0.0132 TPU: +/-0.0132 U 2.70+/-0.250+/-0.398 0.00644+/-0.0126+/-0.0126 3.12+/-0.269+/-0.447 99 (75%-125%)

94 (75%-125%)

Batch 542294 QC1201121837 165557001 DUP Plutonium-238 U 0.0117 U 0.0162 pCi/g 32 (0% -100%) .CWI 06/28/06 23:03 66 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164542 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 542294 Plutonium-239/240 QC1201121839 LCS Plutonium-238 Uncert: +/-0.0336 TPU: +/-0.0336 U 0.00369 Uncert: +/-0.0147 TPU: +/-0.0147 Plutonium-239/240 QC1201121836 MB Plutonium-238 Plutonium-239/240 QC1201121838 165557001 MS Plutonium-238 Plutonium-239/240 Uncert: TPU: 2.48 Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.0281+/-0.0281 U 0.0159+/-0.0221+/-0.0221 U 0.00893+/-0.0143+/-0.0143 2.10+/-0.202+/-0.302 U -0.00137+/-0.0115+/-0.0115 U 0.00435+/-0.0115+/-0.0115 0.0336+/-0.0295+/-0.0297 2.28+/-0.242+/-0.355 U 1.16+/-1.89+/-1.89 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 125 (0%- 100%)(75%-125%)

06/28/06 23:03 85 (75%-125%)

06/28/06 23:03 U 0.0117 Uncert: +/-0.0336 TPU: +/-0.0336 2.52 U 0.00369 Uncert: +/-0.0147 TPU: +/-0.0147 U 0.395 Uncert: +/-1.29 TPU: +/-1.29 (75%-125%)

06/28/06 23:03 91 (75%-125%)

Batch 542295 QC1201121841 165557001 DUP Plutonium-24 I QC1201121843 LCS Plutonium-241 pCi/g 0 (0% -100%) -CWI QC1201121840 MB Plutonium-241 35.0 Uncert: TPU: Uncert: TPU: 35.3 U Uncert: TPU: 27.3+/-1.43+/-3.02 U 0.499+/-0.891+/-0.893 pCi/g pCi/g pCi/g 78 (75%-125%)

07/03/06 16:27 07/03/06 18:31 07/03/06 15:26 07/03/06 17:29 QC1201121842 165557001 MS Plutonium-241 Rad Gamma Spec Batch 537866 QC1201111186 164542001 DUP Actinium-228 0.395+/-1.29+/-1.29 31.7+/-1.58+/-3.43 90 (75%-125%)

0.865+/-0.203 Uncert: 1.05+/-0.191+/-0.191 pCi/g 19 (0%- 100%) MJHI 06/28/06 22:50 67 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164542 Page 3 of 9 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Gamma Spec Batch 537866 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU: +/-0.203 U 0.0409 Uncert: +/-0.0866 TPU: +/-0.0866 0.562 Uncert: +/-0.221 TPU: +/-0.221 0.556 Uncert: +/-0.116 TPU: +/-0.116 U 0.0263 Uncert: +/-0.0382 TPU: +/-0.0382 0.170 Uncert: +/-0.0433 TPU: +/-0.0433 0.239 Uncert: +/-0.0465 TPU: +/-0.0465 U 0.0167 Uncert: +/-0.0586 TPU: +/-0.0586 U -0.0172 Uncert: +/-0.0755 TPU: +/-0.0755 U 0.0597 Uncert: +/-0.0887 TPU: +/-0.0887 0.938 Uncert: +/-0.0991 TPU: +/-0.0991 0.688 Uncert: +/-0.114 TPU: +/-0.114 U 0.0262 Uncert: +/-0.025 TPU: +/-0.025 U -0.00291 Uncert: +/-0.0206 TPU: +/-0.0206 14.4 Uncert: +/-1.33 TPU: +/-1.33 0.556 Uncert: +/-0.116 TPU: +/-0.116 U -0.00368 Uncert: +/-0.0205 U -0.00664+/-0.123+/-0.123 0.777+/-0.333+/-0.333 0.668+/-0.0991+/-0.0991 U! 0.00+/-0.0355+/-0.0355 0.173+/-0.0473+/-0.0473 0.175+/-0.0566+/-0.0566 U 0.0185+/-0.0562+/-0.0562 U -0.00751+/-0.0707+/-0.0707 U 0.0287+/-0.0603+/-0.0603 0.904+/-0.0688+/-0.0688 0.671+/-0.0836+/-0.0836 U 0.0253+/-0.0234+/-0.0234 U 0.0118+/-0.0201+/-0.0201 14.3+/-1.02+/-1.02 0.668+/-0.0991+/-0.0991 U -0.0118+/-0.0182 pCi/g 277 pCi/g 32 pCi/g 18 pCi/g 104 pCi/g 2 pCi/g 31 pCi/g 10 pCi/g 78 pCi/g 70 pCi/g 4 pCi/g 3 pCi/g 3 pCi/g 331 pCi/g I pCi/g 18 pCi/g 105 (0% -100%)(0% -100%)(0% -100%)(0%- 100%)(0%- 100%)(0% -100%)(0%- 100%)(0%- 100%)(0% -100%)(0% -20%)(0%-20%)(0%- 100%)(0% -100%)(0%- 20%)(0% -100%)(0%- 100%)Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m 68 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

164542 Parmname Rad Gamma Spec Batch 537866 Thallium-208 QC1201111187 LCS Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 QC Summary Page 4 of 9 NOM Sample Qual[ QC Units RPD% REC% Range Anist Date Time TPU: Uncert: TPU: Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.63 Uncert: TPU: 14.9 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.0205 0.327+/-0.0551+/-0.0551+/-0.0182 0.317+/-0.0499+/-0.0499 U -0.00725+/-0.547+/-0.547 25.4+/-4.04+/-4.04 U 0.122+/- 1.02+/-1.02 U -0.0901+/-0.245+/-0.245 U 0.0536+/-0.148+/-0.148 9.82+/-0.782+/-0.782 15.0+/-1.13+/-1.13 U -0.193+/-0.334+/-0.334 U 0.107+/-0.334+/-0.334 U -0.15+/-0.350+/-0.350 U -0.0252+/-0.185+/-0.185 U -0.025+/-0.223+/-0.223 U 0.0331+/-0.154+/-0.154 U 0.0941+/-0.127+/-0.127 U 1.25 pCi/g 3 (0%- 100%)pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pci/g 06/26/06 20:54 109 (75%-125%)

102 (75%-125%)

100 (75%-125%)

69 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164542 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 537866 Radium-226 Silver-I 08m Thallium-208 QC1201111185 Actinium-228 Americium-241 MB Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert:.TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-1.28+/-1.28 U -0.0901+/-0.245,+/-0.245 U -0.0742+/-0.115+1-0.115 U 0.0403+/-0.124+/-0.124 U 0.0114+/-0.0487+/-0.0487 U -0.0051+/-0.0126+/-0.0126 U 0.078+/-0.093+/-0.093 U 0.0244+/-0.0241+/-0.0241 U 0.00203+/-0.0122+/-0.0122 U 0.0037+/-0.0112+/-0.0112 U -0.00123+/-0.0121+/-0.0121 U -0.00865+/-0.0314+/-0.0314 U 0.016+/-0.0325+/-0.0325 U -0.0182+/-0.0238+/-0.0238 U 0.0187+/-0.0181+/-0.0181 U 0.0118+/-0.0221+/-0.0221 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 06/28/06 22:49 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 70 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164542 Page 6 of 9 Parmname Rad Gamma Spec Batch 537866 Manganese-54 NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Niobium-94 Potassium-40 Radium-226 Silver-I 08m Thalliun-208 Rad Gas Flow Batch Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U -0.00601+/-0.0127+/-0.0127 U -0.00535+/-0.0123+/-0.0123 UI 0.00+/-0.246+/-0.246 U 0.0244+/-0.0241+/-0.0241 U -0.0068+/-0.0102+/-0.0102 U 0.013+/-0.0121+/-0.0121 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 541208 QC1201119318 164551004 DUP Strontium-90 U -0.0131 Uncert: +/-0.0146 TPU: +/-0.0146 U QCI201119320 Strontium-90 LCS-0.0114+/-0.0131+/-0.0131 1.27+/-0.0859+/-0.0943 pCi/g 0 (0% -100%) BXFI QC1201119317 MB Strontium-90 QC1201119319 164551004 MS Strontium-90 Rad Liquid Scintillation Batch 538969 QC1201113888 163741008 DUP Iron-55 QC1201113890 LCS Iron-55 QC1201113887 MB Iron-55 1.38 Uncert: TPU: Uncert: TPU: 2.55 U Uncert: TPU: U 0.00252+/-0.0114+/-0.0114 pCi/g pCi/g pCi/g 92 (75%-125%)

07/05/06 12:18 07/05/06 14:24 07/05/06 12:18 07/05/06 14:25-0.0131+/-0.0146+/-0.0146 2.38+/-0.153+/-0.169 93 (75%-125%)

U 21.1 Uncert: +/-18.3 TPU: +/-18.5 U-1.03+/-16.3+/-16.3 529+/-44.0+/-86.2 pCi/g pCi/g 0 (0% -100%) SLNI 575 Uncert: TPU: 92 (75%-125%)

06/21/06 10:23 06/21/06 10:40 06/21/06 09:51 U 5.38 pCi/g 71 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164542 Page 7 of 9 Parmname Rad Liquid Scintillation Batch 538969 NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Uncert: TPU: QCl201113889 163741008 MS Iron-55 594 U Uncert: TPU: 21.1+/-18.3+/-18.5 Batch 540445+/-26.8+/-26.8 546+/-33.8+/-74.0 0.0323+/-0.398+/-0.398 12.1+/-0.465+/-0.552 pCi/g 92 (75%-125%)

06/21/06 10:07 QC1201117553 Technetium-99 165011005 DUP U -0.151 Uncert: +/-0.353 TPU: +/-0.353 U pCi/g 0 (0% -100%) EGDI 06/25/06 18:35 QC1201117555 LCS Technetium-99 QC1201117552 MB Technetium-99 12.7 Uncert: TPU: Uncert: TPU: 22.4 U Uncert: TPU: U 0.0683+/-0.184+/-0.184 pCi/g pCi/g pCi/g 96 (75%-125%)

06/25/06 19:07 06/25/06 18:18 06/25/06 18:51 QC1201117554 Technetium-99 165011005 MS-0.151+1-0.353+/-0.353 Batch 541424 QC1201119884 164542011 DUP Nickel-63 QC1201119886 LCS Nickel-63 QC1201119883 MB Nickel-63 QC1201119885 164542011 MS Nickel-63 U -13 Uncert: +/-9.02 TPU: +/-9.03 U 20.2+/-0.830+/-0.969-11.5+/-9.66+/-9.67 408+/-16.6+/-20.9 90 (75%-125%)

pCi/g 0 (0%- 100%) SLNI 512 Uncert: TPU: Uncert: TPU: 553 U Uncert: TPU: U -7.86+/-8.73+/-8.73 pCi/g pCi/g pCi/g 80 (75%-125%)

07/06/06 12:55 07/06/06 13:38 07/06/06 12:34 07/06/06 13:17-13+/-9.02+/-9.03 474+/-19.4+/-24.7 86 (75%-125%)

Batch 542573 QC1201122405 165702005 DUP Tritium QC1201122407 LCS Tritium U 2.71 Uncert: +/-6.22 TPU: +/-6.22 U 4.56+/-6.50+/-6.50 pCi/g 0 (0% -100%) EGDI 07/05/06 04:00 07/05/06 05:03 61.0 Uncert: TPU: 62.7+/-8.39+/-8.46 pCi/g 103 (75%-125%)

72 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn QC Summary Workorder:

164542 Page 8 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Liquid Scintillation Batch 542573 QC1201122404 MB Tritium Uncert: TPU: U 8.19+/-6.12+/-6.12 pCi/g pCi/g 07/05/06 03:28 07/05/06 04:32 QC1201122406 165702005 MS Tritium 63.4 U Uncert: TPU: 2.71+/-6.22+/-6.22 71.0+/-8.48+/-8.57 112 (75%-125%)

Batch 545141 QC1201128389 165011012 DUP Carbon-14 QC1201128391 LCS Carbon- 14 QC1201128388 MB Carbon-14 QC1201128390 165011012 MS Carbon- 14 U -0.20 Uncert: +/-0.313 TPU: +/-0.313 7.13 Uncert: TPU: Uncert: TPU: U -0.23+/-0.300+/-0.300 6.63+/-0.504+/-0.514 U -0.0833+/-0.098+/-0.098 20.9+/-1.56+/-1.59 pCi/g 0 (0% -100%) ATH2 07/07/06 18:35 pCi/g pCi/g pCi/g 93 (75%-125%)

07/07/06 19:40 07/07/06 17:48 07/07/06 19:23 21.5 U Uncert: TPU:-0.20+/-0.313+/-0.313 97 (75%-125%)

Notes: The Qualifiers in this report are defined as follows:*A B BD C D H J N/A R U UI X Y A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product Target analyte was detected in the associated blank Results are either below the MDC or tracer recovery is low Analyte has been confirmed by GC/MS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL 73 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164542 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time A h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.** Indicates analyte is a surrogate compound.A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.74 General Narrative 1 CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 168404 SDG: MSR #06-0652, 06-0675, 06-0687, 06-0688, 06-0707, 06-0743, 06-0755 August 15, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on May 5, May 9, May 12, May 17, May 26, June 2, June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712 ° Charleston, SC 29417 ° 2040 Savage Road (29407)Page 2 of 105 Phone (843) 556-8171

  • Fax (843)1766-1178

° www.gel.com 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F Items of Note: At the request of Dale Randall on July 20, 2006, GEL analyzed the above samples according to the spreadsheet in the attached email.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Seven soil samples were reanalyzed for FSSALL, except gamma and Sr-90.Four soil samples were reanalyzed for FSSALL, except gamma and Ni-63.Two soil samples were reanalyzed for FSSALL, except gamma.Two soil samples were reanalyzed for FSALL, except gamma, Sr-90 and Ni-63.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)Phone (843) 556-8171
  • Fax (843) 766-1178
  • www.gel.com Page 3 of 105 I :

Additional HTD analyses

Subject:

Additional HTD analyses From: "Dale Randall" <randall @cyapco.com>

Date: Thu, 20 Jul 2006 11:04:54 -0400 To: "Cheryl Jones" <cj @gel.corn>

KP99c)WIt CC: "Clyde Newson" <Newson@CYAPCO.com>, "John McCarthy" <McCarthy@

CYAPCO.com>

Cheryl: Per our earlier discussion, attached is a list of samples that we would like to have analyzed to the FSSALL protocol.

I have included a list of test protocols performed on each sample to date. Once you have had an opportunity to determine our options for each sample please call or e-mail me at your convenience.

Thank You, Dale (860) 267-3133 Content-Description:

GEL FSSALL analyses request.x Is GEL FSSALL analyses request.xls.

Content-Type:

appl) cat) onlvnd.ms-excel Content-Encoding:

base64 Page 4 of 105 I oflI 8/2/2006 7:04 PM flnny, To be done Previous rGEL ID CY sample location IDs FSS Gam Sr-90 Ni-63 Am Pu Sr9O Pu241 Fe55 N163 Tc99 H3 C14 M164220008 9106-0002-007F x x x x x x x x x x 164220012 9106-0002-01iF x x x x. x x x x X x 0 162335004 9106-0003-004F x x x x x x x x x x 162335014 9106-0003-015F x x x x x x x x x x 162832015 9106-0004-005F x x x x x x x x x x 162832009 9106-0004-015F x x x x x x x x x x 162485008 9106-0005-01OF x x x x x x x x x x 162485011 9106-0005-014F x x x x I x x x x x 162850014 9106-0006-005F x x x x x x x x x x 163741005 9106-0008-006F x x x x x x x x x x 163741009 9106-0008-008F x x x x x x x x x x 164542008 9106-0009-002F x x x x x x x x x x 164542003 9106-0009-017F x x x x x x x x x x 163105009 9106-0010-001 F x x x x x x x x x x 1163105016 9106-0010-012F x x x x x x x x x x Chain of Custody and Supporting Documentation Page 6 of 105 kV61 Health Physics Procedure 16 Sý q6 LýGPP-GGGR-RS 104-003 -Attachment B-CY-001 Major Chain of Custody Form P eu 1006-Major Connecticut Yankee Atomic Power Company No. 2006-00371 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, .State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones cc W , Priority:

0 30 D. [] 14 D. [] 7 D. Container Sample Size-,.Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-OOIF 5/17/06 10:42 SE C BP x x Transferred from COC 2006-00357 9106-0002-002F 5118106 09:43 SE C BP X Transferred from COC 2006-00361 9106-0002-003F 5/18/06 10:14 SE C BP X X Transferred from COC 2006-00361 9106-0002-004F 5/18/06 10:39 SE C BP X X Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP X X Transferred from COC 2006-00364 9106-0002-006F 5/18/06 13:14 SE C BP x X Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP X X Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:3i7 SE C BP X x Transferred from COC 2006-00364 9106-0002-008F 5/18/06 114:04 SE C BP X x Transferred from COC 2006-00364 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA [] Radwaste QA [I Non QA Samples Shipped Via: Internal 15 Fed Ex Container ol UPS Temp.: Deg. C E Hand Custody Sealed?I e uDate/Time

2) P3.ived By Date/rime Custody Seal S c\'O IOther intact?3Ielinquishi ed B ) Date/Tim e 4) Received By Date/Tim e Bill of Lading Y Bill of Ladfing #5) Relinquished By Date/Ti 6 i B Doa 57/ &5)Reinuihe B Dt'Tme 16) Received By Date/Time Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 1 Major Chain of Custody Form N.20-07 Connecticut Yankee Atomic Power Company No. 2006-00372 00 362 Injun Hollow Road, East Hampton, CT 06424 o 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 c)843 556 8171. Attn. Cheryl Jones I Q Priority:

Z 30 D. [] 14 D.E]7 D. Container Sample Size-.Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample M 9106-0002-009F 5/18/06 14:28 SE C BP x Transferred from COC 2006-00364 9106-0002-OIOF 5/18/06 14:50 SE C BP x X Transferred from COC 2006-00364 9106-0002-011F 5/19/06 08:10 SE C BP x x Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP X x Transferred from COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X X Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP x x Transferred from COC 2006-00365 9106-0002-014FS 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:29 SE C BP x x Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X X -Transferred from COC 2006-00365 NOTES: P0 #: 002332 MSR #: 06- SSWP# NA 23 LTP QA [] Radwaste QA El Non QA Samples Shipped Via: Internal SFed Ex Container UPS Temp.: Deg. C Dl Hand Custody Sealed?I Relin ishe Date/Time

2) Repived By Dat1Time Custody Seal~z1Q&1~ ~ ,gi~ CL~[]E Other Intact?3)'}(elinquished By Date/Time
4) Received By Date/Time BillofLading_#

_Y Y N 0 Bill of Lading-#5) Relinquished By "Date/Time

6) Received By Date/Time "i7o0 't/'t/3 Connecticut Yankee Statement of Work for Analytical Lab Services L .CY-ISC-SOW-001 Figure 1. Sample Check-in List DatefTime Received:-

.SDG#: --"-p5 '-Work Order Number: 4 2 C 2 2-b' ".Shipping Ccltainer IDYIO &' C/[(5 9/O Chain of Custody# -c r3 9 1. Custody Seals oii shipping container intact..?

Yes jkVNo[I 2. Custody Seals dated and signed? YesANo 3. Chain-of-Custody record present? " Yes ¢A No t ].4. Cooler temperature

'5. Vermiculitelpacking materials is: Wet [ ] Dry 6. -Number of samples in shipping container:

______7. Sample holding times exceeded?

Yes []8. Samples have:*tape labelscustody seals _ appropriate sample labels 9. Samples are-S_)in good condition -leaking.broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [] NoX]11.. .Description of anomalies (include sample numbers): A Sample Custodian/Laboratory:

Date.:______________

Telephoned to: On .B Page 9 of 105 Connecticut Yankee Statement of Work for Analytical Lab Services-CY-ISC-SOW-001 Figure 1. Sample Check-in List.Date/Time Received,',ý " 6 C,'_Work Order Number: Shipping Ccfntainer ID 1 q t/ 5 i.T Chain of Custody tJQ2V (a QV37 'I. Custody Seals oxi shipping container intact?...

Yes No []2. Custody Seals dated and signed? Yes.1 No [1 3. Chain-of-Custody record present? ( Yes No.4. Cooler temperature O(.) '5. Vermiculite/packing materials is: Wet [ Dry ip] C '6: Number of samples in shipping container:.

  • __ ;____ *____7. Sample holding. times excieeded?

--Yes []No...9. Sa~s hve'.: a.___.-hazard labels custody seals -appropriate sample labels 9. Samples are:.Xiin good condition leaking._broken .ave air bubbles 10. Were any anomalies identified in sample receipt? Yes ( I No 11. * .Description of anomalies (include sample numbers): Sample Custodian/Laboratory: 1 , Date: -Telephoned to: On By.~J.Page 10 of;105 SAMLERECEIPT

& REVIEW FORM mit I-Clet(,Ap4,r4ýnW0!-SDG/ARCOC/Work Order: DateReceved:PM(A)

Review (ensure non-conforming items are resolved prior to signing);[Received By: Sample Receipt Criteria Comments/Qualiliers (Required for Non-Conforming Items)Shipping containers received intact Circle Applicable:

seals broken damaged comainer lea$g container other (describe) and sealed? 7 Samples requiring cold Circle Coolant # ice bags blue icee dry ice none other describe)2 preservation within (4 +/- 2 C)?Record preservation inethod.Chain of custody documents included with shipment?

rnt Sample containers intact and imic Applica ,s bren damaged container eaking conainer othe (describe) sealed? ,_,___ID's.

__ontainersaffe___d___dobservedpH:

5 Samples requiring chemical Sa IDs. containers affected and observed pH: preservation at proper pH? ......VOA vials free of headspace Sample 11's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

.,,," 8 Samples received wi -holding Id's and tes affected: time? _ ___ ___9 Sample ID's OC match ID's sample ID's and containers affected: on bottles?Date & me on COC match date Sample ID's affected: ti on bottles? ______ID'___ffe__ed_

Nu ber of containers received Sample ID's affected match number indicated on COC?COC form is properly signed in relinquished/reccived sections?

Co " .Air Bill ,Tracking

  1. 's, &S j *If > x2 area background is observed on samples identified as "non-Suspected Hazard Information t;.=.Z dic regulated/non-radioactive", contact the Radiation Safety group for further__ investigation.

A lRadiological Classification?

Maximum. Counts Observed*:'

C.r," B fPCB Regulated?

V Comments: IShipped as DpT Hazardous C I Material?

If yes, contact Waste Hazard Class Shipped: Manager or PSH Manager. UN#: PM (or PMA) review of Hazard classiticaiion:

Initials Date: W 17L(' .(I Page 11 of 105 SAMPLE RECEIPT & REVIEW FORM PM use only Cicent: Ccnr))_'"A--1C(

Order: / ZIZZ Date Received:

-0' O~o PM(A) Review ( c -nonconfor

  • ng I are resolved prior to signing): Received By: Sample Receipt Criteria 4 Z Comments/Qualil equired for Non-Conforming Items)IShipping containers received intact Cir-e Applicable:

seals br damaged container leaking container other (describe) i and sealed?7 F 9aU1- I " !u, &,s a A boe ice dry ice none other describe)2 ]preservation within (4 +/- 2 C)?_ Record preservation method. I I /I 3 Chain of custody documents included with shipment?4 Sample containers intact and ,sealed?sSamples requiring chemical Ipreservation at proper pH?61 VOA vials free of headspace 6 (defined as < 6mam bubble)?C pplicable:

seals broken damaged container leaking container other (describe) gample ID's. 'conainers affected and observed pH: Sample ID's and containers affected:-, a -Tu l IAre Encore containers present? ..7 (if yes, inumediately deliver to /VIVOA laboratory) 8 Samples received within holdin d's and tests affected.Itime?' I S 9 ample ID's on COC mat ID's Sample ID's and contaners affected:_ on bottles?/1Date & time on COC ich date Sample ID's affected:& time on bottles?Number of containerreceived Sample ID's affected: match number indic ted on COC?COC form is pro ny signed in...re.nuished/recve" sections?.oo(, & 1,6 14'24 i Bill ,Tracking

  1. 's, &AAdditional Comments" > RSO RAD Receipt# --Suspected Hazard Intormation o *If > x2 area background is observed on samples identified as "non--2zregulated/non-radioactive-, contact the Radiation Safety group for furtherat. o ens A_ RailgclMaaximurnCounts Observed*:_

,.CMaterial?

If yes, contact Waste Hazard Class Shipped: ,'Manager or ESH Manager. UN#: PM (or PMA) review of Hazard classification:

Initials Date: Page 12 of 105 Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Chain of Custody Form Connecticut Yankee Atomic Power Company No. 260-362 Injun Hollow Road, East Hampton, CT 06424 4 [ ':g.4 '/860-267-2556 1_____________________________________________

Project Name: Haddam Neck Decommissioning Analyses Requested

_Lab.Use Only.Contact Name & Phone: 'onu0 ents: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories

.2040 Savage Road. Charleston SC. 29407 9.843 556 8171. Attn. Cheryl Jones Cn W Priority:

Z 30 D.[E] 14 D. E] 7 D. Container Sample Size-Media Type &Type L m Sample Designation Date Time Code Code Code Comment, Preservation Lab "9106-0003-01F 4/24/06 14:13 BP x Transferred from C.C2006-00221 i'z 9106-0003-002F 4/24/06 14:39 SE C BP X Transferred from COC2006-00221

-!? 9106-0003-003F 4/24/06 15:01 SE C BP X Transferred from COC2006-00221 9106-0003-004F 4/25/06 08:41 SE C BP X Transferred from C0C2006-00223 9106-0003-004FS 4/25/06 08:41 SE C B3P x Transferred from COC2006-00223 9106-0003-005F 4/25/06 09:21 SE C BP X Transferred from COC2006-00223 9106-0003-006F 4/25/06 09:46 SE C BP X Transferred from COC2006-00223

_ 9106-0003-007F 4/25/06 10:28 SE C BP X Transferred from COC2006-00223 9106-0003-008F 4/25/06 11:15 SE C BP X Transferred from COC2006-00223 NOTES: PO #: 002332 MSR #: 06- SSWP#NA Z LTP QA E Radwaste QA E Non QA Samples Shipped Via: ":',Jnternbj1 Coi6t r Combined samples 9106-0003-003F taken on 4/25/06 @08:19 and 9106-0003-003FB taken on 4/25/06 @ 08:19 in order to have sufficient sample for counting. (Z Fed Ex -.e mp. Deg[]UPS [ Hand Custody :Sealed? .:: 1) Relinquished By Date/Time

2) /ec ived By cDatefTime Custody Se61 Intact?-.5- "c0g//.3.3O , d j(rl _ El Other 3) Relinquished By Date/Time
4) Received By -,a./Time_.__"__

..) ..N.Bill of Lading #5) Relinquished By Date/Time

6) Received By Date/Time

.- 92O- 02 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major (b CD 010 01 Chain of Custody Form No. 2006-00313 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 /(.Z:3 860-267-2556

-- / _____-- _____o/, Project Name: Haddam Neck Decommissioning Analyses Requested US&R : Contact Name & Phone: .Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones ..Priority:

Z 30 D. E 14 D. [ 7 D. Container Sample Size- ._,__.._._-___._,.

._._Media Type &Type li S !i Sample Designation Date Time Code Code Code Comment, Preservation pie 9106-0003-009F 4/25/06 13:00 SE C BP x ' Transferred from COC 2006-00236

'" 9106-0003-010F 4/25/06 13
23 SE C BP X "' -TransfcrredfromCOC2006-00236 S9106-0003-00FS 4/25/06 13:23 SE C BP X -Transferred from COC 2006-00236 9106-0003-012F 4/25/06 15:12 SE C BP Transferred from COC 2006-00236 9106-0003-013F 4/25/06 14:21 SE C BP xTrnsferred from COC 2006-00236 9106-0003-014F 4/25/06 14:48 SE C BP x Transferred from COC 2006-00236 9106-0003-015F 4/26/06 08:16 SE C BP x Transferred from COC 2006-00237 6 9106-0003-016F 4/26/06 09:41 SE C BP x Transferred from COC 2006-00237 9106-0003-017F 4/26/06 09:18 SE C BP X ""_Transferred from COC 2006-00237 I

4/26/06 0R:59 gE IC BP x Transferred from COu 2006-002-7

,9106-0003-01 8F 4/26/06 08:59 SE C BP NOTES: PO #: 002332 MSR #: 06- 0& SSWP#NA Z LTP QA LI Radwaste QA jj Non QA 1) Relinquished By Date ime 2)Received By fime 3) Relinquished By Date/Time

4) Received By Dafe/Time Samples Shipped Via:[ Fed Ex[] UPS I] Hand El Other Bill of Lading 4*t912-Sg/j2-0261'eTernp.;'

",Pg A ,r cvxJ" ~I Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Che*k-in List Date/Time Received:

t4 .,0) $SDG#: /AA6f&,4-C)

Work Order Number: i Shipping Ccohtainer IDl: 1' 0 li IChain of Custgdy # ,G _t. Custody Seals on shipping container intact?.- -Yes t No 2. Custody Seals dated and signed? Yes[ No 3. Chain-of-Custody record present? Yes No [4. Cooler temperature

  • CIl C-5. Vermiculite/packing materials is: Wet DrynI] _6- Number of samples in shipping container:

[i (A§ico I (I1 i , 7- Sample holding times exceeded?

Yes [ No:8. Sampleshot S"tp ..hazard labels.J custody seals -appropriate sample labels 9. Samples are-good condition -broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes ' ] No 11. .Description of anomalies (include sample numbers):

-_Sample, Custodian/Laboratory: (C) ,(vY (:" tt.Telephoned to: On By -Page 15 of 105 SAMPL RECEIPT & REVIEW FORM uaGV 3~~5 Client: SDG/ARCOC/Work Order: DaeReceived:

roý 45 5 6P()Rve ensure ne fo a re resolved prior to siging)l: Received By: Cý r _'-Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items)1 Shipping containers received intact Circle Applicable:

seals broken damaged container leaking contalner oter (describe) and sealed? C Samples requiring cold Circl Coolnt U ice bagt blue e dr ice none 2 preservation within (4 +/- 2 C)?Record preservation method. _ _ _ _ _ _ _ _ _ Pen__ _"_ _Chain of custody documents included with shipment?4 Sample containers intact and Circle Applicable:

seals broken damaged container leaking comainer odwe (describe) sealed?5 Samples requiring chemical Sample ID's. containers affected and observed pH:_ preservation at proper pH? ....VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

--Samples received within holding rd's and tests affected;8 time,?...

.9 Sample ID's on COC match ID's Sample ID's and containers affected: on bottles?Date & time on COC match date Sample ID's affected: i& time on bottles?Number of containers received Sample ID's affected: match number indicated on COC?12COC form is properly signed in relinquished/received sections?Air Bill ,Tracking

  1. 's, & '"c iLO j C Y ZO ?-(A Additional Comments C ?7..-,a V RSO RAD Receipt #Wl rd jý A c -t *f> x2 area background is observed on samples identified as "non-Suspected Hazard Information 0 S Hazar regulated/non-radioactive", contact die Radiation Safety group for further_ _ __~_i nvestigation.

A Radiological Classification!

' Maximum Counts Observed*:

Shipped as JX)I Haaous C Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. /N#: /PM (or PMA) review of Hazard classification:

Initials Page 16 of 105 a r, P I ý I Health Physics Procedure GPP-GGGR-R5 104-003 -Attachment B-CY- 001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 i860-267-2556-Project Name: Haddam Neck Decommissioning

'Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

Z 30 D. [114 D. [] 7 D.Samples Shipped Via: 0 Fed Ex E uPs[] Hand M Other Bill of Lading #

" Health Pbys~s, Pr~edure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major Cqnu!qjvc Yankee Atomic Power Company' " njun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: H-laddam Neck Decommissic Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 u Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

Z30D. [] 14 D M7 D.Samples Shipped Via:[ Fed Ex El UPS El Hand Ml Other Bill of Lading #

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O01 Figure 1. Samplc Check-in List c- , Date/Time Received:

,,. /,'. 0 G SDG#: I A6 R O -Work Order Number: 1 Shipping Container ID: -_71+i Z- 8-32.1. Custody Seals on shipping container intact?2. Custody Seals dated and signed?3. Chain-of-Custody record present?4. Cooler temperature

5. Vermiculite/packing materials is: 6. Number of samples in shipping container:
7. Sample holding times exceeded?6 I Chain of Custody #~ooo -60 S.7 -Yes No ]Yes No []Yes No [J Wet J$ Dry []Yes [I No 8. Samples have:.tape hazard labelscustody seals __._appropriate sample labels 9. Samples are:_ in good condition

_4 leaking broken have air bubbles 10. Were any anomalies identified in sample receipt? Yes, No []11. Description of anomalies (include sample numbers): Sample Custodiar/Laboratory:

A-Telephoned to: On Date: ~~.e 0 , d 9'. .e B y .v-Page 45 of 56 Page 19 of 105 Connecticut Yankee Statement of Work for Analytical Lab Services CY-isC-SOW-O0 Figure 1. Sample Check-in List.Date/Time Received: ( " oq SDG#: 1.&. .O -W ork Order Num ben r :__ _(_a_ __ _ __ _Shipping CainerlID:.

Chain of Custody# -1. CustodySeals onshipping container intact? Yes [ ] No 2. Custody Seals dated and signed? Yes' [ ] No J 3. Chain-of-Custody record present? Yes 0 No [1 4. Coolef

_s. Velite/packing materials is: Wet w Dry t',yI 6J ..iNumber of samples in shipping container:

"_ _-_"_ -__-7. Sample holding times exceeded?

Yes No.8.. Samples have:'2 tpl ea -h a z ad la b e ls.2mgody Seals -.appropriate Sample labels 9. Samples ar:-M good condition ickn*bkc ....ave air bubbles 0. Were any aunoalies identifiedin sample receptYs[JNo1 psrtino nmlc(inClude sarinple numer): CQIOL S4ample. C .stodIn/Laboratory.

._-Telephoned to:_ _ _ _______________

Page 20 of 105 4~h)h- 4V 4~~SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM DIM C)o 112 3j -ACJ+( rV-Iq* c 3gq:5 cas ~oo V2,so N i5c -61v had c ox_ _ _ _ __ _ _ _ _bU-5f e- -5CL ry)i'LeA .F ~ G v- _ __ __ __ __ __ _Page 21 of 105 I 'II 0 SAMPLE RECEIPT & REVIEW FORM a PM use onrly Client: C4./ CL " fr. ,, SDG/ARCOC/Work Order: / (. o3 7..-Date Received: , .,PM(A) Review (ensure non-conforming items are resolved prior to signing): Veccived By: /7 1 ,Ih '.j _ _ _ _ _ _ __ _ _ _ _ _Sample Receipt Criteria Z Comments/Quafiriers (Required for Non-Conforming Items)1 Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (descrnbe) 1and sealed?Samples requiring cold Cicle Coolant # ice bag blue ice dry ice none other describe)2 preservation within (4 + /- 2 C)?Record preservation method.Chain of custody documents 3included with shipment?

Y 4 Sample containers intact and Circle Applicable:

seals broken damaged container lqtaiip other (describe) sealed? -<W li 2/s ( -Qo0a0 j -a 1 o p 5 Samples requiring chemical Saple W's. consiven affected and observed pH preservation at proper pH?6 JVOA vials free of headspace Sawple ID's and containers affected: ( (defined as < 6mm bubble)? ... ... .Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

__Samples received within holding Id's and tests 2afected: 8 time?Sample ID's on COC match ID's i ID's ard comnine" affected: on bottles?10 Date & time on COC match date San* ID'S affect:& time on bottles?1 Number of containers received Sarpl ID's aftected: match number indicated on COC? _12 COC form is properly signed in 1relinquished/received sections? .d A-to- r , ,d.A 7 A k4 Al Air Bill ,Tracking

  1. 's, &Additional Comments RAD Receipt________

..ected Hazrd Info tIf > x2 area background is observed on samples identified as .on-*r,. :-: -m ' a _Pl _ contact the Radiaon Safttyngroup for further...._____ "_______.

_______ _ [ uinvest tion.SRadeoogieal Classification?

-Maximum Counts Ob. ,.cd < c.CB Rp,1,egulated?.

stuppe as Ur H7azardlous CMaterial?

If-yes, contact Waste ardlmW e-Manager or ESH Manager.h- 1ijw of Hazard classification:nials U

SAMPLE RECEIPT & REVIEW FORM PhM use only Cflent: Van kj b ~SDGIARCOC/Work Order: /6. Z 91 7, Da'te Received:

L 14!() PM(A) Review (esurre nom-coafornuItiU ft re resolved pdio to sipalug):-Received By: (21 r I __....Sample Receipt Criteria CommentsiQtillrie-s (Required for Non-Conforming Items)Shipping containers received intact Circle Applicable.

seals broken damaged container leaking cornainer other (describe) and sealed? ,_ _ _ __ ___,__Samples requiring cold Circle Coolant I ice bags blue ice dry ice other describe)2 preservation within (4 +/- 2 C)?Record preservation method. ... ....Chain of custody documents Co C) (S Cxx C> V Ur., ..included with shipet Sample containers intact and ircie able seats hi damagedconainer leaking contaner (descri sealed? O4c~5v"lleu_

O 'Ji i Samples requiring chemical aple IDa. conainers affecied and observed pH: preservation at proper pH? .. .. .....VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)? ,,_._........

Are Encore containers present? ,, 7 (If yes, immediately deliver to VOA laboratory),, Samples received within holding Id's and em affected: time? .....Sample ID's on COC match ID's Sample iD'S and conie affected: on bottles?Date & time on COC match date Sample ID's affected:& time on bottles?Number of containers received a ID'3 affected: match number indicated on COC? 1_COC form is properly signed in no, Cb'.Ls "L, vYL_ "%Ll 3ikp Ct 1relin uised/received sections?

0 %1 Air Bill ,Tracking

  1. s, & T., CEf ,'Y") U .,f :i Ise- t- -Additional Comments V TU RSO RAD Receipt#S Hn *If > x2 area background is observed on samples identified as "non-Suspted Hazard Information "F regulatedlnon-radioactive-" contact the Radiation Safety group for further MG e investigation.

A Radiological Classification?

V/ Maximum Counts Observed*:

q , B lPCB Regulated?

o jShipped as DUV1 Hazardous McMaterial?

If yes, contact Waste t Hazard Class Shipped: JManager or ESH Manager. .UN-PM (or PMA) review of Hazard classification:

Initials Date: ., -Fage2_3 f 10 O"'1!

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 7 7 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

N 30 D. [] 14 D. n 7 D.Samples Shipped Via: E Fed Ex[] UPS EL- Harnd El Other Bill of Lading #7qA'7 ?/9S 413-S Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-001 Figure 1. Sample Check-in List.Date/Time Received: SDG#: Work Order Number: \X 9 2- A ",.Shipping Cdctainer ID, -!A -,%" 4'ý 5 7)t o6 Chain of Custody # 06b 3,-0C / e OOAt 1. Custody Seals onishipping container intact? Yes ,No[]2. Custody Seals dated and signed? Yes e4No [].3. Chain-of-Custody ecord present? Yes SINo []4. Cooler temperature q 5. Vermiculite/packing materials is: Wet WDry ]6.' Number of samples in shipping container.:

_ _ _ _" 7. Sample holding times exceeded?

Yes [ ] No 8. Samples have:*t tape _" hazard labels." custody seals -appropriate sample labels 9. Samples ar".:.ingood condition

-/--leaking(gst.

..).broken have air bubbles 10. Were any anomalies identified in sample receipt? Yes [INo L'.I. Description of anomalies. (include sample numbers): Sample .ustodiannLaboratoyD

-Telephoned to:.nB____________

POn 25Byf*.Page 25 of 105 .,- ..I. Il 9 SAMPLE RECEIPT & REVIEW FORM 01 PM use only jClient: &[ 6 ,SDGIARCOCIWork Order: IG 2-(86lDate Received:

yPM(A) Review (ensure non-coaFormipg items are resolved prior to signing): ,Rcie By: I Sample Receipt Criteria Z Comments/Qualifiers (Required for Non-Conforming Items)Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe) a sealed?Samp requiring cold Circle Coolant # ice bags blue ice dry ice none other deseribe)2 preservati within (4 +/- 2 C)?Record preserv' n method.Chain of custody d nts 3.included with shipment?SSample containers intact and Circle Applicable:

seals broken damaged container leaking container other (describe),sealed?; Samples requiring chemical Sampl ID's. containers affected and observed pH: preservation at proper pH?6 VOA vials free of headspace Sample ID's and containers affected:-(defined as < 6mm bubble)?Are Encore containers present?_7 (If yes, immediately deliver to VOA laboratory) 6~8 Samples received within holding Id's and tests affected: time?9 Sample ID's on COC match ID's Sample ID's and containers affected: on bottles?Date & time on COC match date Sample ID's affected:-& time on bottles?Number of containers received Sample ID's affected: match number indicated on COC?COC form is properly signed in 12 relinquished/received sections?14 Air Bill ,Tracking

  1. 's, & F1( i q g cf 1q5- 4 ' b2 f. -/7 o--Additional Comments /PC,' -,a P0 -RSO RAD Receipt #n *If > x2 area background is observed on samples identified as "non-Suspected Hazard Information "0 S e r U regulated/non-radioactive".

contact the Radiation Safety group for further cc investigation.

PCB1 Ra gilate? Maximum Counts Observed*:

~ P' Reglate?0, Commients; Shipped as D01 Hazardous C CMaterial?

If yes, contact Waste Hazard Class Shipped:-Manager or ESH Manager. UN#: PM (or PMA) review of Hazard classification:

Initials Date: 7t 77-a~ 0, iFavc; /-U 01 IV)U Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company .. " .362 Injun Hollow Road, East Hampton, CT 06424'860-267-2556

., ______.-._--_.

...___-__________

______"_.Project Name: Haddam Neck Decommissioning Analyses Requested

-,ý2ontact Name & Phone: -4 #i ., 4 JackMcCarthy 860-267-2556 Ext. 3024 'Analytical Lab (Name, City, State) '" '" : General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 (J 843 556 8171. Attn. Cheryl Jones U). .Priority:

[ 30 D. [ 14 D.-] 7 D. Container

.._________________

_______ _______Sample Size-Media Type &Type , Sample Designation Date Time Code Code Code Comment, Preservation 9106-0006-004F 4/28/06 12:46 SE C BP X x Transferred from COC 2006-00317 9106-0006-005F 4/28/06 13:03 SE C BP X X Transferred from COC 2006-00317 9106-0006-006F 4/28/06 13:22 SE C BP X x Transferred from COC 2006-00317 9106-0006-007F 4/28/06 13:41 SE C BP X ---Transferred from COC 2006-00317 9106-0006-007FS 4/28/06 13:41 SE C BP X x Transferred from COC 2006-00317 9106-0006-012F.

5/01/06 13:40 SE C BP X X Transferred from COC 2006-00317 9106-0006-017F.

5/01/06 14:03 SE C BP X x Transferred from COC 2006-00317 NOTES: PO #: 002332 MSR #: 06- cýT"1 SSWP# NA M I .n Non [A Sample s Shipped Via:_' Fed Ex L] ups El Hand 1) Relinquished By DatefTime

2) Received By ate/Time L_,. [U other 3) Relinquished By Date/Time
4) Received By ate/Time Bill of Lading #
  • Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-901 Figure 1. Sample Check-in List.Date/Time Received:

J 7 SDG#: Work OrderaNumber

___._1_ __-Shipping CdhtainerID: c..t ChainofCustody#

Ste o ej'f- s I. Custody Seals. oishpping container intact? ... -Yes ( NokJ: 2. Custody Seals dated and signed? Yes [] No 3. Chain-of-Custody recordpresent?

Yes W)N0 [ ]4. Cooler temperature C-.>5. Vermiculite/packing materials is: Wet J) Dry , " 6: Numb"rofsranWesin'shippingcon-ain,,..

c "..7. Sample holding tiMes exceeded?

Yes[]No 8. Sample have--.!~..ape ....-hazard labels-custody seals appropriate sample labels 9. Samples are: good co,,ditionl broken -: "j have air bubbles 10. Were any anomalies identified in salple reipt? Yes [] No IL. -Descriptjon of anomalies (include sample numbers):," Sample Custodian/LAboratory.

2 > 4Jat: /j~Telephoned to:___________________

Page28of 105

-11 SAMPLE RECEIPT & REVIEW FORM rR °ON_,ToRt weM only Chient: JnriSDG/ARCOC/Work Order: /~~16M!, /6 Z765-0 Date Received:

fl PM(A) Review (nuenncnomn tm ame resolved prior to sigaiag):

J Received By: C t1Q-evj I __sample Receipt Criteria z I Comments/Qualirlers (Required for Non-Coaforming Items)I Shipping containers received intact C irce Applicable:

seats broken damaged cotamier leakiag container odher (descrbe)and sealed ? -C # bbd=3 Samples requiring cold/r- Coolant N iebags blue ice dry ice other 2 preservation within (4 +/- 2 C)?Record preservation method .... _ .., ,3 Chain of custody documents

/ U C.SO S ox L \V LA included with shipment?

I 4 lSample containers intact ad QixcApp na bt bI damag/d cornsaer lcakntiguiner

ýoda (d_ 5 Samples requiring chemical Sp ID's. coinr affce a obsmed pH: ab .Preservation at proper pH?6 VOA vials free of headspace Sample IDs sad conainers affected: (defined as < 6mrnm bubble)?Are Encore containers present?7 (If yes, immediately deliver to V VOA laboratory)

......8 Samples received within holding Id's and tests affected: lime? v e_9 Sample ID's on COC match ID's Siaile ID's andc coaines affected: on bottles? I Date & time on COC match date Sattiple ID* affected:& time on bottles?_____________________________

Number of containers received S/i ID's rm: match number indicated on COC?COC form is properly signed in y CbC cx.-, v Li YA, licl 12 relinquished/received sections?

M________"I,___U__________1___VU__

4 Air Bill ,Tracking

  1. 's, & SU C(+/-lY)t.L A,- -Additional Comments V RSO RAD ReceiptI_

....(--as *Jf > x2 area background is observed on samples identified as -non-SuspectedHazardInformation rguatd/non-radioactivel, contact the Radiation Safely group for further , F. investigation.

AIRadological Classification?

M IMaximum Counts Obseed*: 4 ,f)1PCD Regulated?

Commentse:

Shipped as LD)01 Hazardous Hi Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. UN#: PM (or PMA) review of Hazard classification:

initials Date: -r'age /Y of1 U._a ,11 -1,1 itl SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM Fid F, -r--ft- CooCw ______________-

La 1055 a ýw' -(50) (0tnavdF, " UaA4 -.5 e hcoo h a _ _ _ ___bm-sl ud Page 30 of 105'1 T. R1!

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003 -Attachment B-CY-0O I Major (5 0 0 (A Chain of Custody Form N.20-06 Connecticut Yankee Atomic Power Company No. 2006-00367 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556

...... 3-7 .Project Name: Haddam Neck Decommissioning

--Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 , o 843 556 817 1. Atta. Cheryl Jones .Priority:

Z 30 D.[] 14 D. ] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0008-OO1F 5/05/06 11:13 SE C BP x x x .Transferred from COC # 2006-00324 9106-0008-003F 5/5/06 13:35 SE C BP X X x " Transferred from COC # 2006-00325 9106-0008-004F 5/5/06 13:51 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-005F 5/5/06 14:17 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-006F 5/5/06 14:36 SE C BP X" x -Transferred from COC # 2006-00325 9106-0008-006FS 5/5/06 14:36 SE C BP X X x Transferred from COC # 2006-00325 9106-0008-007F 5/5/06 15:03 SE C BP x Transferred from COC # 2006-00325 9106-0008-002F 5/5/06 13:10 SE C BP x x x Transferred from COC # 2006-00325 NOTES: PO #: 002332 MSR#: 06-0-K{3 SSWPfNA M LTP QA E Radwaste QA El Non QA Sa E E-1-1 I,10 1) elinqm'sh iv de e "1-'I~at 3) kinmquished By k,0 Date/Time

4) y v \X I b~ate/Time B maples Shipped Via: Fed Ex lUPS H Rand] Other 11 of Lading #:Z-t 515 5 11/92.-Internal Container Temp.: -Deg. C Custody Sealed?YO NO Custody Seal Intact?YO NO i gq Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00366 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & %one: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road, Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones W r .Priority:

N 30 D. " 14 D. E) 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID j 9106-0008-008F 5/08/06 08:01 SE C BP X X X Transferrmd from COC # 2006-00327 0 9106-0008-009F 5/08/06 08:32 SE C BP X X X Transferred from COC # 2006-00327 oil 9106-0008-01OF 5/08/06 09:09 SE C BP X X X Transferred from COC # 2006-00327 01* 9106-0008-01OFS 5/08/06 09:09 SE C BP x x x Transferred from COC # 2006-00327

)'A 9106-0008-01IF 5/08/06 09:30 SE C BP x x x Transferred from COC'# 2006-00327

)1 9106-0008-012F 5/08/06 09:53 SE C BP x Transferred from COC # 2006-00327 9106-0008-013F 5/08/06 10:16 SE C BP x x x Transferred from COC i 2006-00327 9106-0008-014F 5/08/06 10:47 SE C BP x x x Transferred from COC # 2006-00327 NOTES: PO #: 002332 MSR #: 06-61q3 SSWP# NA Z LTP QA [I Radwaste QA El Non QA Samples Shipped Via: 0 Fed Ex 0I UPS[] Hand[] Other Bill of Lading #Internal Container Temp.: 2-J Deg. C 1) Relinquished By Date/Time 2) Received By r ei Date/Time Custody Sealed?Y 0 N)'Custody Seal Intact?Y50 NO 3) Relinquished By Date/Time

4) Received By Date/Time Connecticut Yankee Statement of Work for Analytical Lab Services A6371 4Z CY-ISC-SOW-001 Figure 1. Sample Cheek-in List.Date/Time Received:

AQbhUI('M\eJ SDG#: Work Order Number:____

Shipping Cdotainer ID: .I Chain of Custody 1# 00ý -0 0 1. Custody Seals. on" shipping container intact? .. -Yes [TNo [ ]2. Custody Seals dated and signed? Yes[ ] No [II.3. Chain-of-Custody record present? Yes [-4.0o [ ]4. Cooler temperature

.7 5. Vermiculite/packing materials is: Wet [ Dry 't,] A/A 6.' Number of samples in shipping container:

.___"_'____

"_"______7. Sample holding times exceeded?

Yes [ No 10. Were any anomalies identified in sample receipt? Yes'[] No 11....Description of anomalies. (include sample numbers):

_Telephoned to:_________

______ By -on_____ __________

Page 33 of 105 ENGZ 0 SAMPLE RECEIPT & REVIEW FORM PM e omly I Best: SDG/ARCOCPWark Order:[Date Received:

A0 , F( ev (u*sure Item wreisned prier to nlag): Received By~ (KJ __________________

Sample Receipt Criteria CommeunsIQuallfiers (Required for Non-Conforming Items)Shipping containers received intact C/Alweip k e seals: sc ab , damma e , com ume

,.er(d scru- -c)and sealed? I =4 Samples requiring cold Ckk Cooln lee bags ble i dry ice I 2 preservation within (4 +/- 2 Q?R eco rd p rese rv ation m eth od ..._._'____ ....Chain of custody documents included with shipment?Sample containers intact and eats k dmadcoine k o.f e sealed?Saniples requiring chermical npk D'MP. comalam affected and observed pH: Dreseration at proper PH?VOA vials free of headspace sa pe sD', ta OF-, (defined as < 6umm bubble)?_/

Are Encore containers present?7 (If yes, Inuediately deliver to VOA laboratory)

Samples received within holding Id's and am affected: time?9 le ID's on COC match ID's /eID'S Md comiafffected:

onbottles?

Da1 & [t on COC match date ID'S affecid:& time on bottles?Number of containers received /awk ID'S affwted: match number indicated on COC?12 COC form is properly signed in relinquished/received sections?Air Bil ,Tracking

  1. 's, &14 ki ICommnents l q ..i: .-----Suspeed Hazard Information ii Vu 0 LORAD Remo "#" If > x2 area backgound is observed On samoples idezitill as non.Did ai e radioctive', contact the Radiation Safety group for further r m i n-eigation.

..I A l'maoogical "amuncaotjon

j'RI] B u p e as D T a ar o u s- -TiMatenPtrial?.

If yes, contact Waste L IManager or ESH Manager.Counts Observed*:

IMuAM Clas Shipped:]NI: PM (or PMA) review of Ha-nrd classifcaion:, I LNAm S .5,L'/.~ýOla Date: Page 34 of 105 SAMLERECEIPT

& REVIEW FORM v Uen,"l Client: -an k.. ..DGARCOCIWork Order:7 Date Received: kv PM(A) Review (ensure non-conronnlng items are resolved prior to signing): Received By: C ,olti. ¢J7- I 'Sample Receipt Criteria Z Z CommentslQualiflers (Required for Non-Conforinng Items)Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe) and sealed? __Samples requiring cold Circle Coolant # ice bags blue ice dry ice i5 ow describ 2 preservation within (4 +/- 2 C)?-Record preservation method. ___ ___Chain of custody documents 3included with shipment?

.___.--_._

4 Sample containers intact and Cire Applicable:

seals broken damaged container leaking container oece (describe) sealed? _Samples requiring chemical Sample ID's. containers affected and observed pH: preservation at proper pH? _6 VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to l r VOA laboratory) 8 8i1eSamples received within holding "d'sandmaffected:

time? _____________________________

9 Sample ID's on COC march ID's Sample ID's and containers affected: 9on bottles?10 Date & time on COC match date Sample ID's affected:& lime on bottles? __________________________

Number of containers received -lSample ID's affected: match number indicated on COC? I COC form is properly signed in 4 w ,,,/ w" d 2 relinquished/received sections?14 Air Bill ,Tracking

  1. s, & , ( I 5 .Additional Comments Suspected Hazard Information lvl Is,'l.~l I~I KJ 5, RSO RAD Receipt #S*lf > x2 area background is observed on samples identified as "non-regulated/non-radioactive', contact the Radiation Safety group for further EEivestigation.

[A jkadiological Classification?

nP F VI red*: 00 frpm PCB Regulated?

Shipped as DOT Hazardous Material?

If yes, contact Waste Manager or ESH Manager.(.ornments:

lazard Class Shippe-d: IN#: Initials 0e./ Date: PM (or PMA) review of Hazard classification:

9-Page 35 of 105 J(0 a1r/Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:-

z Ibt) (t. O3zb SDG#: Work Order Number: Shipping Container ID: -19 ZI 5 -t_ i I "7 Chain of Custody# , _ T_1p " La-.C i. Custody Seals on shipping container intact?.-

Yes o 2. Custody Seals dated and signed? Yes L,4-0o [ ]-S3. Chai;k-of-Custody record present? Yes L.1o [ ]4. Cooler temperature

5. Vermiculite/packing materials is: Wet VrD ry [ ]& Number of samples in shipping container: (i 'La'"I hk1-7. Sample holding times exceeded?

Yes-[] No 8. Samples have: tape hazard labels.custody seals ____appropriate sample labels 9. Samples are..it/in good condition leaking-r__ obrken .have air bubbles 10. Were any anomalies identified in sample receipt? Yes [] No [.I--11. Description of anomalies (include sample numbers): Sample Custodian/Laboratory:

t '/ ---i .... Date:______

____Telephoned to: -On By Page 36 of 105 Health Physics Procedure/_ Ij g-a-1 , J.OPP-GGGR-R5104-003 -Attachment B-CY-00 I Major H h sP dG G 10 t m B0*Cs-1 0 0 A Chain of Custody Form No. 2006-003 80 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested LabiUs Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories

<2040 Savage Road. Charleston SC. 29407 C <843 556 8171. Attn. Cheryl Jones En z Priority:

Z 30 D. [] 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0009-016F 5/15/06 13:28 SE C BP X -Transferred from COC 2006-00352 9106-0009-016FS 5/15/06 13:28 SE C BP X X " Transferred from COC 2006-00352 9106-0009-017F 5/15/06 14:03 SE C BP x x Transferred from COC 2006-00352 9106-0009-01 IF 5/15/06 08:05 SE C BP x Transferred from COC 2006-00351 9106-0009-013F 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 9106-0009-013FS 5/15/06 08:35 SE C BP X X Transferred from COG 2006-00351 9106-0009-014F 5/15/06 08:59 SE C BP x Transferred from COC 2006-00351 9106-0009-015F 5/15/06 09:36 SE C BP x x Transferred from COC 2006-00351 910-009-05F

/1506 9:36 S C_____ BP X Tanfere rmC 20-05 OVA?NOTES: PO #: 002332 MSR #: 06-O/9' SSWP# NA SLTP QA F] Radwaste QA E] Non QA 1) Relinquisd By Date/Time 2)=yecv Date/Time Rni evcy-t 3) Relinquished By Date/Time

4) Rdelevell By Date/Tirne Samples Shipped Via:[ Fed Ex 0 Hand El Other Bill of Lading #_ýq21-z/.?

/Y 2AtF Internal Container Temp.: __ Deg. C Custody Sealed?YO NI]Custody Seal Intact?Y ['1 N ]-

Health Physics Procedure l(o0~;~4'~

I GPP-GGGR-R5104-003-Attachment B-CY-001 Major-I -C U Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00381 362 Injun Hollow Road, East Hampton, CT 06424 D860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones n z Priority:

30 D. [] 14 D. [17 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0009-OOIF 5/11/06 13:22 SE C BP X X Transferrod from COC 2006-00347) 9106-0009-002F 5/11/06 13:46 SE C BP x x Transferred from COC 2006-00347 1 9106-0009-003F 5/11/06 14:06 SE C BP X X Transferred from COC 2006-00347 ( 9106-0009-004F 5/11/06 14:30 SE C BP X X Transferred from COC 2006-00347 IA 9106-0009-005F 5/11/06 14:55 SE C BP X X Transferred from COC 2006-00347

?,- 9106-0009-007F 5/12/06 07:44 SE C BP X X Transferred from COC 2006-00348 9106-0009-008F 5/12/06 08:16 SE C BP X x Transferred from COC 2006-00348 4' 9106-0009-009F 5/12/06 08:35 SE C BP X X Transferred from COC 2006-00348

{ 9106-0009-01OF 5/12/06 09:07 SE C BP X X Transferred from COC 2006-00348 a'7 of 0(of NOTES: PO #: 002332 MSR#: 06-SSWP# NA Z LTP QA El Radwaste QA El Non QA 1) Relinquished By Date/Time

2) Rec Date/Time 3) Relinquished By Date/Time
4) Received t By Date/Time Samples Shipped Via: Z Fed Ex El Hand El Other Bill of Lading #4tC?11 ZYTT Internal Container Temp.: _ Deg. C Custody Sealed?YO NO Custody Seal Intact?Y 0 ND U"I TVoýCy-lSC-SOw-o00 Connecticut Yankee Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List Date/Time Received: (b7- 0jW SDG#: Ms 0-4C_)-ý I' 19 0S I Work Order Number: Shipping Cchtainer ID.'_ /I Chain of Custody # __'__________
1. Custody Seals ori shipping container intact?. -Yes iX No [2. Custody Seals dated and signed? Yes [ No 3. Chain-of-Custody record present? Yes 14 No t ]4. Cooler temperature

..'L-5. Vermiculite/packing materials is: Wet [ J Dry 6- Number of samples in shipping container:

7. Sample holding times exceeded?

Yes ( No 10. Were any anomalies identified in sample receipt? Yes I I No 11. ..Description ofanomalies.(include sample numbers): Sample Custodian/Laboratory:

Date: -Z -O IG, Telephoned to: On By_Page 39 of t05 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00349 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: 'Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Z Priority:

Z 30 D. [] 14 D. [ 7 D. Container Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID i 9106-0010-OOIF 5/04/06 10:49 SE C BP X X Transferred from COC 2006-00321 51O 9106-0010-002F 5/04/06 11:12 SE C BP X X TransfemrAd from COC 2006-00321 Ot 9106-0010-004F 5/04/06 12:48 SE C BP X x Transferred from COC 2006-00321 0i 9106-0010-006F 5/04/06 13:34 SE C BP X X Transferred from COC 2006-00321 9106-0010-007F 5/04/06 13:21 SE C BP X x Transferred from COC 2006-00321 9106-0010-009F 5/04/06 14:01 SE C BP X X Tramferred from COC 2006-00321 9106-0010-OIOF 5/04/06 14:21 SE C BP X X Transferred from COGC2006-00321 9106-0010-012F 5/04/06 14:44 SE C BP X X Transferred from COC 2006-00321 9106-0010-013F 5/04/06 15:06 SE C BP X Tranlsferred from COC 2006-00321 NOTES: PO #: 002332 MSR#: 06- 0o70 SSWP#NA SLTP QA[I Radwaste QA El Non QA 1) Relinquish eBy Date/Ti e 2) Received y Date/Time 3) Relinquished By DateTime 4) Received By Date/Time Samples Shipped Via: 0 Fed Ex D UPS[] Hand El Other Bill of Lading #3q04-3 113- g;-41 Intemal Container Temp.: _7Deg. C CustoddSealed?

Y 0' NO0 Custody Seal Intact?Y 0"N 0 Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-o0l Figure 1. Sample Check-in List Date/Time Received:

qqr S"/17/I06 Work Order Number: __ _ _ _ __ _ _ _ __ _ _ _ _Shipping Cdntainer ID: ] 'I 8 Chain of Custody '04# 603V 1. Custody Seals ori shipping container intact?. -Yes.[( No []2. Custody Seals dated and signed? Yes' [M No [ ].3. Chain-of-Custo'jy record present? Yes [,Q No []4. Cooler temperature (7' C 5. Vermiculitefpacking materials is: Wet $, Dry (\]6. Number of samples in shipping container:

q_;7. Sample holding times exceeded?

Yes No P.8. Samples have:-tape -hazard labels.- custody seals -_appropriate sample labels 9. Samples are--!---in good condition

... eaking-broken .have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ ] No j~j 1 1.. Description of anomalies (include sample numbers): Sample Custodian/Laboratory:

Date- "--O Telephoned to: On 0y " .Page 41 of 105 GI/N SSAMPLE RECEIPT & REVIEW FORM 00~~1roRVPM uiiese only Client: SDG/ARCOcWork Or Date Received:

5" -0b]PM(A)

Review ( ites are resolved prior to signng): Received By: A-U'1,_,__

__ ___ __ ___ _, Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items)Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe) and sealed? ___Samples requiring cold Circle Coolant # ice bags blue ice dry ice g other describe)2 preservation within (4 +/- 2 C)?Record preservation method.Chain of custody documents included with shipment?4 Sample containers intact and Circle Applicable:

seals broken damaged container leaking container other (describe).sealed?Samples requiring chemical Sample ID's. containers affected and observed pH: preservation at proper pH?6 VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory) 8 Samples received within holding I's and tests affected: time?9 Sample ID's on COC match ID's Smple ID's and containers affected: on bottles?Date & time on COC match date Sample UDs affected:&time onbottles?

on Number of containers received Sample ID's affected: match number indicated on COC?12 COC form is properly signed in relinquished/received sections?14 Air Bill ,Tracking

  1. 's, & QiIl Additional Comments 7"7 V RSO RAD Receipt # _____________

j *If > x2 area background is observed on samples identified as "non-Suspected Hazard Information regulated/non-radioactive", contact the Radiation Safety group for further__ investigation.

A Radiological Classification?

V111 Maximum Counts Observed*:

lSnippeda as DUuT azardous r aadCasSipd c Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. a InN#: r PM (,o- PMA) review of Hazard classification: ,Initials t ,Date: ,,f.0 /Page 42 of 105 List of current GEL Certifications as of 15 August 2006 r State Alaska Arizona Arkansas CLIA-California Colorado... ....Connecticut

.. ... .. .Dept. of Navy EPA Florida/NELAP Georgia Idaho Illinois Indiana Kansas Kentucky Maryland Massachusetts Michigan Nevada New Jersey New York North Carolina North Carolina Drinking W North Dakota Oklahoma Pennsylvania -A South Carolina Tennessee Texas U.S. Dept. of Agriculture US Army Corps of Engineer Utah Vermont Virginia Washington Certification UST-062 AZO068 88-0651 42D0904046 01 15 ICA GenEngLabs PH-0169 NFESC 413 WG-15J E187156 E87156 (FL/NELAP)

N/A 200029 C-SC-0 I E-10332 90129 270 M-SC012 9903 sci2§C002 11501 233 45709 R-158 9904 68-485 10120001/10585001/10120002 TX213-2006A S-52597 N/A 8037697376 GEL.. .. .. .N /A ......00151 C223 Page 43 of 105 RADIOLOGICAL ANALYSIS Page 44 of 105 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 168404 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555696 554650 554649 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404011 168404012 168404013 168404014 168404015 1201153129 1201153130 1201153131 1201153132 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011 (9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Page 45 of 105 Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 168404003 (9106-0003-004F) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Page 46 of 105 Product: Alphaspec Am241, Cm, Solid ALL FSS DOE EML HASL-300, Am-05-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 557837 554650 554649 Sample ID 168404009 168404010 1201158316 1201158317 1201158318 1201158319 Client ID 9106-0006-005F 9106-0008-006F Method Blank (MB)168404009(9106-0006-005F)

Sample Duplicate (DUP)168404009(9106-0006-005F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404009 (9106-0006-005F).

QC Information Page 47 of 105 All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS DOE EML HASL-300, Pu- 11-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555697 554650 554649 Page 48 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201153133 1201153134 1201153135 1201153136 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-OOIF 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Page 49 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu-I 1-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555698 554650 554649 Page 50 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201153137 1201153138 1201153139 1201153140 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-01OF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Guality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Page 51 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 556350 554650 554649 Page 52 of 105 Sample ID 168404003 168404004 168404012 168404013 168404014 168404015 1201154644 1201154645 1201154646 1201154647 Client ID 9106-0003-004F 9106-0003-015F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168404003(9106-0003-004F)

Sample Duplicate (DUP)168404003(9106-0003-004F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Page 53 of 105 Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Samples 1201154644 (MB), 1201154645 (9106-0003-004F), 1201154646 (9106-0003-004F), 1201154647 (LCS), 168404003 (9106-0003-004F), 168404004 (9106-0003-015F), 168404012 (9106-0009-002F), 168404013 (9106-0009-017F), 168404014 (9106-0010-001F) and 168404015 (9106-0010-012F) were dried and reweighed due to low matrix spike/laboratory control sample recovery.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 554580 Page 54 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150561 1201150562 1201150563 1201150564 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-01OF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-OO1F 9106-0010-012F Method Blank (MB)168340012(9304-02-003C)

Sample Duplicate (DUP)168340012(9304-02-003C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Page 55 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555722 554650 554649 Page 56 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201153222 1201153223 1201153224 1201153225 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-OO1F 9106-0010-012F Method Blank (MB)168340012(9304-02-003C)

Sample Duplicate (DUP)168340012(9304-02-003C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Page 57 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: Prep Method: DOE RESL Ni-1, Modified Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555723 554650 554649 Page 58 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 1201153226 1201153227 1201153228 1201153229 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F Method Blank (MB)168340012(9304-02-003C)

Sample Duplicate (DUP)168340012(9304-02-003C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Page 59 of 105 Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Analytical Batch Number: Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150569 1201150570 1201150571 1201150572 LSC, Tritium Dist, Solid-HTD2,ALL FSS EPA 906.0 Modified 554582 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)Page 60 of 105 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 168404010 (9106-0008-006F) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Page 61 of 105 Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: Analytical Batch Number: Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150573 1201150574 1201150575 1201150576 EPA EERF C-01 Modified 554583 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168404003(9106-0003-004F)

Sample Duplicate (DUP)168404003(9106-0003-004F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Page 62 of 105 Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.Page 63 of 105 The following data validator verified the information presented in this case narrative:

Reviewer/Date:

KýJ§6ý ze ý6 Page 64 of 105 SAMPLE DATA

SUMMARY

Page 65 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: 168404 GEL Work Order: 168404 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by Page 66 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Ctertifieate nf Analwivd Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Project: YANKO 1204 Sample ID: 168404001 Client ID: YANKOO Matrix: SE Vol. Recv.: Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector:

Client Moisture:

20.9%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0762 Curium-242 U 0.00 Curium-243/244 U -0.00853+/-0.102+/-0.0995+/-0.0717 0.00 0.00 0.0405+/-0.102+/-0.0995+/-0.0717 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U (Plutonium-239/240 U 0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U).199 0341+/-0.228 0.181 +/-0.229+/-0.129 0.120 +/-0.129 10.0 +/-6.64 5.08 +/-6.72 4.17 +/-6.67 5.28 +/-6.67 0.0956 0.138 0.177 0.444 0.323 10.7 11.4 0.132 65.9 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1336 555696 1 BXLI 08/11/06 1633 555697 2 BXL1 08/16/06 1220 555698 3 DFAl 08/09/06 1128 554582 4 ATH2 08/09/06 0324 554583 5 MXPI 08/12/06 1633 555722 6 MXPI 08/11/06 0738 555723 7 EGD1 08/11/062027 554580 8 Liquid Scint C14, SolidAllFSS Carbon-14 U Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 0.0813+/-0.0797 0.0634 +/-0.0797 9.90 +/-48.1 32.0 +/-48.1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.02 +/-6.39 5.18 +/-6.40 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.139 +/-0.213 0.173 +/-0.213 10.6 pCi/g 0.360 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300.

Am-05-RC Modified 2 3 4 DOE EML HASL-300, Pu-I l-RC Modified DOE EML HASL-300, Pu-1 I-RC Modified EPA 906.0 Modified Page 67 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Project: YANKO 1204 Sample ID: 168404001 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA EERF C-01 Modified 6 DOE RESL Fe-i, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 80 (15%-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 100 (15°/o- 125%)Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 98 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fc55, Solid-ALL FS 75 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 74 (15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 68 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0002-01 IF 168404002 SE 19-MAY-06 02-JUN-06 Client 17.4%Proiect: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Re Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U C Curium-242 U -0.1 Curium-243/244 U -0.1 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.'Plutonium-239/240 U 0.1 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -0 Liquid Scint C14, SolidAllFSS Carbon-14 U 0 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0 esult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd.120 0146 0103 0121 0254 6.72'.521'.023 3.93 7.52.173+/-0.154+/-0.122+/-0.0861+/-0.125+/-0.0675+/-7.02+/-7.03+/-0.0828+/-47.7+/-5.81+/-0.203 0.0683 0.0692 0.0487 0.127 0.0381 5.56 5.94 0.0685 31.9 4.68 0.164+1-0.155+/-0.123+/-0.0862+/-0.125+/-0.0675+/-7.05+/-7.03+/-0.0828+/-47.7+/-5.81+/-0.203 0.251 0.303 0.213 0.344 0.167 11.7 12.8 0.143 65.7 9.60 0.341 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1336 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1237 555698 3 DFAI ATH2 MXPI MXPI EGD1 08/09/06 1143 554582 08/09/06 0426 554583 08/12/06 1649 555722 08/11/06 0825 555723 08/11/06 2043 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I 1-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 69 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-01 IF Project: YANKO 1204 Sample ID: 168404002 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 76 (15%-1125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 100 ( 15°%r- 125%)Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 88 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%/o- 125%)Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 70 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0003-004F 168404003 SE 25-APR-06 05-MAY-06 Client 23.5%Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.027 Curium-242 U 0.112 Curium-243/244 U 0.0217 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.061 Plutonium-239/240 U 0.0551 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.00343 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.603 Liquid Scint C14, Solid AlFSS Carbon-14 U 0.0937 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 7.68 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.74 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0643 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.117+/-0.315+/-0.206+/-0.189+/-0.103+/-5.73 0.153 0.245 0.205 0.176 0.0584 4.40+/-0.117+/-0.315+/-0.206+/-0.189+/-0.103+/-5.78+/-0.0203 0.0172 +/-0.0203 0.488 0.781 0.594 0.449 0.215 9.25 0.036 14.8 0.134 70.4 13.6 0.351 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/13/06 0819 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1253 555698 3 BXFI 08/14/06 0834 556350 4+/-8.25+/-0.0813+/-51.2+/-7.12+/-0.198 6.87 0.0642 34.2 6.58 0.169+/-8.25+/-0.0813+/-51.2+/-7.13+/-0.198 DFA I ATH2 MXPI MXPI EGD I 08/09/06 1159 554582 08/09/06 0529 554583 08/12/06 1706 555722 08/11/06 0912 555723 08/11/06 2059 554580 5 6 7 8 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified Page 71 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-004F 168404003 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 4 5 6 7 8 9 DOE EML HASL-300, Pu-I 1-RC Modified EPA 905.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-l, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery.Test Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL F5 GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%42 92 113 59 71 83 76 Acceptable Limits (15%-125%)

(15°/o-125%)

(25%-6125%)

(25%-/125%)

(15%-125%)

(25%1.- 125%)(15%/,-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 72 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Project: YANK01204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: 9106-0003-004F 168404003 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.Page 73 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0003-015F 168404004 SE 25-APR-06 05-MAY-06 Client 22.5%Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0456 Curium-242 U 0.113 Curium-243/244 U 0.180 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0196 Plutonium-239/240 U 0.0326 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.63 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00477 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 1.03 Liquid Scint C14, SolidAllFSS Carbon-14 0.156 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -9.99 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.939 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.237 The following Prep Methods were performed Method Description Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+1-0.155+/-0.181+/-0.239+/-0.121+/-0.0639+/-6.19 0.139 0.0733 0.181 0.118 0.00 4.86+1-0.155+/-0.182+/-0.240+/-0.121+/-0.064+/-6.22+/-0.0216 0.0179 +/-0.0216 0.387 0.321 0.472 0.324 0.0884 10.2 0.0375 12.6 0.146 59.2 21.6 0.353 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1309 555698 3 BXF1 08/14/06 0834 556350 4+/-7.06+/-0.0912+/-42.7+/-10.1+/-0.213 5.85 0.0699 28.7 10.3 0.170+/-7.06+/-0.0913+/-42.7+/-10.1+/-0.213 DFAI ATH2 MXPI MXPI EGDI 08/09/06 1215 554582 08/09/06 0632 554583 08/12/06 1722 555722 08/11/06 1001 555723 08/11/06 2115 554580 5 6 7 8 9 Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified Page 74 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-015F 168404004 Project: YANK01204 Client ID: YANKO0I Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 4 5 6 7 8 9 DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified EPA 906.0 Modified EPA EERF C-0I Modified DOE RESL Fe-1, Modified DOE RESL Ni-1, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%78 94 101 58 75 62 75 Acceptable Limits (15%-125%)

(15%-125%)

(25%-/125%)

(25%- 125%)(15%-125%)

(25%-7125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 75 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate.

of Anavldw Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: 9106-0003-015F 168404004 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.Page 76 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0004-005F 168404005 SE 03-MAY-06 12-MAY-06 Client 15.4%Proiect: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Ri Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -(Curium-242 U -0.Curium-243/244 U -0.Aiphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.Plutonium-239/240 U -0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U (Liquid Scint C14, SolidAllFSS Carbon-14 0 Liquid Scint Fe55, Solid-ALL FSS lron-55 U -Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.esult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.036 0169 0129 0217 0708 9.52).854 1.347-1.57 6.39 0198+/-0.123+/-0.033+/-0.227+/-0.163+/-0.0791+/-6.00+/-5.88+/-0.097+/-46.0+/-7.62+/-0.187 0.157 0.080 0.247 0.181 0.128 4.57 4.87 0.0674 30.7 7.40 0.156+/-0.123+/-0.03 31+/-0.227+/-0.163+/-0.0795+/-6.07+/-5.88+/-0.0972+/-46.0+/-7.62+/-0.187 0.437 0.350 0.619 0.444 0.337 9.61 10.5 0.141 63.2 15.5 0.324 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1326 555698 3 DFAI ATH2 MXP1 MXPI EGDI 08/09/06 1231 554582 08/09/06 0734 554583 08/12/06 1738 555722 08/11/06 1017 555723 08/11/06 2131 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-0I Modified Page 77 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0004-005F 168404005 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 DOE RESL Fe-I, Modified DOE RESL Ni-1, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%65 95 105 78 80 80 Acceptable Limits (15%-125%)

(15%-125%)

(25%/a- 125%)(15%-125%)

(25%-61259/6)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 78 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0004-01 5F 168404006 SE 03-MAY-06 12-MAY-06 Client 26.5%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier RI Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.Curium-242 U -0.Curium-243/244 U -0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.Plutonium-239/240 U -(Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, Solid Al, FSS Carbon-14 U 0.Liquid Scint Fe55, Solid-ALL FSS lron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.1 esult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 0823 0154 0994 0466 1.142 6.64-2.9 0352 1.88 3.88 0894+/-0.203+/-0.0301+/-0.251+/-0.213+/-0.108+/-6.53+/-7.59+/-0.0868+/-46.8+/-7.46+/-0.198 0.178 0.0729 0.300 0.210 0.191 5.16 6.60 0.0713 31.3 7.40 0.163+/-0.203+/-0.0302+/-0.251+/-0.213+/-0.109+/-6.57+/-7.59+/-0.0868+/-46.8+/-7.46+/-0.198 0.469 0.319 0.713 0.521 0.483 10.8 14.2 0.149 64.4 15.5 0.338 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1342 555698 3 DFA I ATH2 MXPI MXPI EGDI 08/09/06 1247 554582 4 08/09/06 0837 554583 5 08/12/06 1754 555722 6 08/11/06 1033 555723 7 08/11/06 2147 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 79 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0004-015F 168404006 Project: YANK01204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýLiquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%72 72 94 73 80 78 Acceptable Limits (15%-125%)

(15%-125%)

(25%-I125%)

(15%-125%)

(25%-.125%)

(15%-125%o)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 80 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0005-OIOF 168404007 SE 02-MAY-06 09-MAY-06 Client 56.2%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Ri Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -(Curium-242 U -0.Curium-243/244 U -0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.Plutonium-239/240 U 0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAIlFSS Carbon-14 U 0.Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -esult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 1.128 0115 0333 0548 0195 10.4 0.00 0636 36.1 7.26 0.05+/-0.0939+/-0.128+/-0.122+/-0.169+/-0.121+/-6.89+/-6.86+/-0.0801+/-44.1+/-10.2+/-0.199 0.142 0.147 0.149 0.158 0.117 5.27 5.76 0.0644 28.7 10.0 0.169+/-0.0942+/-0.128+/-0.122+/-0.170+/-0.121+/-6.97+/-6.86+/-0.0801+/-44.1+/-10.2+/-0.199 0.385 0.450 0.401 0.403 0.322 11.1 12.4 0.135 59.0 20.9 0.351 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1358 555698 3 DFA I ATH2 MXP1 MXPI EGD 1 08/09/06 1303 554582 08/09/06 1017 554583 08/12/06 1811 555722 08/11/06 1049 555723 08/11/06 2203 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-0I Modified Page 81 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-011OF Project: YANK01204 Sample ID: 168404007 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 85 (15%-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15°/-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 92 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 (15%-1125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 64 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 77 (15%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 82 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0005-014F 168404008 SE 02-MAY-06 09-MAY-06 Client 32.3%Project: YANKO1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00591 Curium-242 U -0.04 Curium-243/244 U 0.0634 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0694 Plutonium-239/240 U -0.0287 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.68 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 6.02 Liquid Scint C14, SolidAIlFSS Carbon-14 U 0.0892 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 19.8 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.41 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.134 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.219+/-0.0554+/-0.261+/-0.106+/-0.098+/-8.01+/-6.38+/-0.0827+/-46.3+/-7.91+/-0.192 0.231 0.134 0.249 0.160 0.127 6.48 4.90 0.0655 30.6 7.77 0.167+/-0.219+/-0.0557+/-0.261+/-0.106+/-0.0981+/-8.02+/-6.38+/-0.0827+/-46.3+/-7.91+/-0.192 0.608 0.494 0.646 0.434 0.369 13.6 10.6 0.137 62.9 16.2 0.346 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1415 555698 3 DFAI ATH2 MXPI MXPI EGD1 08/09/06 1319 554582 08/09/06 1424 554583 08/12/06 1827 555722 08/11/06 1106 555723 08/11/06 2218 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu- 11-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 83 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0005-014F 168404008 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%50 61 74 76 76 75 Acceptable Limits (15%-125%)

(15%-125%)

(25%-I 25%)(15%-125%)

(25%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 84 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0006-005F 168404009 SE 28-APR-06 12-MAY-06 Client 16.5%Proiect: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Re Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.(Curium-242 U -0.(Curium-243/244 U -0.(Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.(Plutonium-239/240 U 0.0(Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -Liquid Scint C14, SolidAllFSS Carbon- 14 0 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0(suit Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 0851 0253 0479 0183 0122 4.43 2.02.142 12.6 7.70 0659+/-0.136+/-0.0495+/-0.0542+/-0.113+/-0.0662+/-5.83+/-6.67+/-0.0798+/-47.6+/-9.56+/-0.185 0.106 0.120 0.131 0.110 0.0694 4.67 5.76 0.061 31.7 9.31 0.156+/-0.136+/-0.0496+/-0.0545+/-0.113+/-0.0662+/-5.85+/-6.67+/-0.0799+/-47.6+/-9.56+/-0.185 0.390 0.525 0.443 0.303 0.221 9.82 12.4 0.127 65.3 19.5 0.323 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 08/16/06 0949 557837 1 BXLI 08/11/06 1633 555697 3 BXLI 08/16/06 1431 555698 4 DFAI ATH2 MXPI MXPI EGD1 08/09/06 1335 554582 08/09/06 1719 554583 08/12/06 1843 555722 08/11/06 1122 555723 08/11/06 2234 554580 5 6 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 DOE EML HASL-300, Pu-l 1-RC Modified 5 EPA 906.0 Modified Page 85 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Anaivsis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0006-005F 168404009 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 9 EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%76 93 105 72 64 81 Acceptable Limits (15%-125%)

(15%-125%)

(25%-125%)

(15°/-6125%)

(25%-.125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 86 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0008-006F 168404010 SE 05-MAY-06 26-MAY-06 Client 34.8%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U I Curium-242 U Curium-243/244 U -0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.Plutonium-239/240 U 0.0 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS Carbon-14 U Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U+/-0.195+/-0.202+/-0.0316 0.0758 0.00 0.0766+/-0.196+/-0.203+/-0.0317+/-0.0711 0.0967 +/-0.0712+/-0.113 0.118 +/-0.113 14.9 +/-6.37 4.64 +/-6.51 0.00 +/-6.06 5.09 +/-6.06 M.107 +/-0.0846 0.0664 +/-0.0846 15.1 +/-41.4 27.5 +/-41.4).258 +/-0.225 0.179 +/-0.225 0.332 0.280 0.335 0.275 0.317 9.75 10.7 0.139 56.6 0.373 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/16/06 0949 557837 1 BXLI 08/11/06 1633 555697 3 BXLI 08/16/06 1447 555698 4 DFAI 08/10/06 2150 554582 5 ATH2 08/09/06 1822 554583 6 MXPI 08/12/06 1900 555722 7 EGDI 08/11/06 2251 554580 " 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 6 7 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-1 I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-1, Modified Page 87 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: 9106-0008-006F 168404010 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 8 DOE EML HASL-300.

Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Recovery%

Acceptable Limits Alphaspec Am241, Cm, Solid ALl Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 77 94 103 72 71 (15%-125%)

(15%-125%)

(25/.-1 25%)(15%/o-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 88 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Report Date: August 21, 2006 Project: Soils PO# 002332 Client Sample ID: 9106-0008-008F Project: YANKO1204 Sample ID: 168404011 Client ID: YANK001 Matrix: SE Vol. Recv.: Collect Date: 08-MAY-06 Receive Date: 26-MAY-06 Collector:

Client Moisture:

35.7%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Ailphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.Curium-242 U -0.Curium-243/244 U -0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.Plutonium-239/240 U -0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS Carbon-14 U -0.Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.+/-0.192+/-0.142+/-0.202 0.152 +/-0.193 0.132 +/-0.142 0.240 +/-0.203+/-0.096 0.125 +/-0.096+/-0.114 0.137 +/-0.114 0.426 0.446 0.603 0.328 0.353 10.7 10.7 0.133 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 11.5 +/-6.72 5.08 +/-6.80 0.00 +/-5.92 4.97 +/-5.92 0238 +/-0.0745 0.0636 +/-0.0745-10.7 +/-40.9 27.5 +/-40.9 0956 +/-0.211 0.174 +/-0.211 BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1504 555698 3 DFAI 08/09/06 1407 554582 4 ATH2 08/09/06 1924 554583 5 MXPI 08/12/06 1916 555722 6 EGD1 08/11/062307 554580 7 56.8 pCi/g 0.361 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 6 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I 1-RC Modified DOE EML HASL-300, Pu-l -RC Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified Page 89 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0008-008F 168404011 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 7 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýLiquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 65 98 96 76 74 (15%-125%)

(15%-/125%)

(25%-/125%)

(15%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCiMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.U1 Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier* QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 90 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.00144 Curium-242 U 0.0192 Curium-243/244 U 0.013 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00587 Plutonium-239/240 U 0.0186 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.6 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.0151 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.12 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.046 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 12.9 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.078 9106-0009-002F 168404012 SE 11-MAY-06 08-JUN-06 Client 33%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+1-0.155+/-0.145+/-0.268 0.166 0.135 0.281+/-0.155+/-0.145+/-0.268+/-0.0493 0.0279 +/-0.0494+/-0.0492 0.0278 +/-0.0493+/-6.90 5.13 +/-7.01+/-0.0146 0.0114 +/-0.0146+/-8.36 6.70 +/-8.36+/-0.0755 0.0613 +/-0.0755+/-40.6 26.8 +/-40.6+/-0.203 0.168 +/-0.203 0.458 0.455 0.687 0.122 0.122 10.8 0.0242 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 08/11/06 1434 555696 1 BXLI 08/11/06 1632 555697 2 BXL1 08/16/06 1520 555698 3 BXF1 08/14/06 0834 556350 4 DFAI 08/09/06 1422 554582 5 ATH2 08/09/06 2027 554583 6 MXPI 08/12/06 1932 555722 7 EGDI 08/11/06 2323 554580 8 14.5 pCi/g 0.128 55.2 0.348 pCi/g pCi/g pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300.

Am-05-RC Modified 2 3 4 DOE EML HASL-300, Pu-I11-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified Page 91 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Project: YANK0 1204 Sample ID: 168404012 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 61 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15%- 125%)Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 94 (25°/o- 125%)Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (25°%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 ( 15%- 125%)Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 92 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-017F 168404013 SE 15-MAY-06 08-JUN-06 Client 28.4%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0755 Curium-242 U 0.0957 Curium-243/244 U -0.073 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00629 Plutonium-239/240 U 0.0262 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.3 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.0205 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.583 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0271 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -61.9 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0628+/-0.242+/-0.220+/-0.214 0.230 0.171 0.256+/-0.243+/-0.220+/-0.214 0.574 0.509 0.627 0.131 0.0709 pCi/g pCi/g pCi/g pCi/g pCi/g+/-0.0529 0.0299 +/-0.0529+/-0.0513 0.00 +/-0.0514+/-6.66 4.95 +/-6.77+/-0.0151 0.0116 +/-0.0151+/-7.98 6.65 +/-7.98+/-0.0759 0.0625 +/-0.0759+1-150 102 +1-150+/-0.200 0.165 +/-0.200 10.4 pCi/g 0.0246 14.4 0.131 210 0.343 pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1632 555697 2 BXLI 08/16/06 1536 555698 3 BXFI 08/14/06 0833 556350 4 DFAI 08/09/06 1438 554582 5 ATH2 08/09/06 2129 554583 6 MXPI 08/12/06 1949 555722 7 EGD1 08/11/06 2338 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 3 4 DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified Page 93 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0009-017F 168404013 Project: YANKO 1204 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 6 7 8 EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%64 91 96 72 73 79 Acceptable Limits (15/%-125%)

(15%-125%)

(25%- 125%)(25%-/125%)

(15%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 94 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0010-OO1F 168404014 SE 04-MAY-06 17-MAY-06 Client 27.3%Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0 Curium-242 U 0.Curium-243/244 U 0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U (Plutonium-239/240 U -0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U (Liquid Scint C14, SolidAllFSS Carbon-14 U 0.'Liquid Scint Fe55, Solid-ALL FSS lron-55 U -Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U C+/-0.227+/-0.167+/-0.242+/-0.181+/-0.0865 0.238 0.00 0.241+/-0.227+/-0.168+/-0.242 0.143 +/-0.182 0.0951 +/-0.0866 0.628 0.231 0.634 0.331 0.235 10.0 0.0262 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 13.0 +/-6.44 4.78 +/-6.54 0128 +/-0.0141 0.0125 +/-0.0141 0.548 +/-7.50 6.25 +/-7.50 0555 +/-0.0809 0.0655 +/-0.0809-18.1 +/-47.6 32.3 +/-47.6 1.134 +/-0.205 0.167 +/-0.205 BXLI 08/11/06 1434 555696 1 BXL1 08/11/06 2250 555697 2 BXLI 08/16/06 1553 555698 3 BXF1 08/14/06 0833 556350 4 DFAI 08/09/06 1454 554582 5 ATH2 08/09/06 2232 554583 6 MXPI 08/12/06 2005 555722 7 EGD1 08/11/06 2354 554580 8 13.5 pCi/g 0.137 66.6 0.347 pCi/g pCi/g pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 3 4 DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified Page 95 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0010-00IF 168404014 Project: YANK01204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 6 7 8 EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%50 85 99 74 70 75 Acceptable Limits (15%-125/)

(15%-125%)

(25%-6125%)

(25%-6125%)

(15%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 96 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0010-012F 168404015 SE 04-MAY-06 17-MAY-06 Client 28.1%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.110 Curium-242 U -0.0547 Curium-243/244 U -0.126 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00157 Plutonium-239/240 U 0.0867 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 Rad Gas Flow Proportional Counting GFPC, Sr90, solid ALL FSS Strontium-90 U -0.00771 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.896 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0162 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 23.3 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0577 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.184+/-0.141+/-0.184 0.140 0.192 0.245+/-0.184+/-0.141+/-0.185+/-0.126 0.122 +/-0.126+/-0.0869 0.0406 +/-0.0872+/-6.16 4.77 +/-6.21+/-0.0144 0.0124 +/-0.0144+/-6.17 5.11 +/-6.17+/-0.0763 0.0633 +/-0.0763+/-49.3 32.5 +/-49.3+/-0.206 0.171 +/-0.206 0.386 0.544 0.597 0.291 0.128 10.0 0.0263 11.0 0.132 67.0 0.354 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 2250 555697 2 BXLI 08/16/06 1609 555698 3 BXFI 08/14/06 0833 556350 4 DFAI 08/09/06 1510 554582 5 ATH2 08/09/06 2334 554583 6 MXPI 08/12/06 2021 555722 7 EGDI 08/12/06 0010 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 3 4 DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu- 11-RC Modified EPA 905.0 Modified Page 97 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0010-012F 168404015 Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 6 7 8 EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýGFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%81 91 99 68 74 75 Acceptable Limits (15%-125%)

(15%-125%)

(25%-I125%)

(25%-6125%)

(15%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 98 of 105 I QUALITY CONTROL DATA Page 99 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client: Connecticut Yankee Atomic Power 362 Injun Hollow Rd Renort Date: August 21, 2006 Page 1 of 6 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

168404 Parmname Rad Alpha Spec Batch 555696 QC1201153130 168340011 DUP Americium-241 Curium-242 Curium-243/244 QC1201153132 LCS Americium-24 I Curium-242 Curium-243/244 QC1201153129 MB Americium-241 Curium-242 Curium-243/244 QC1201153131 168340011 MS Americium-241 Curium-242 Curium-243/244 NOM Sample Qual OC Units RPD%REC% Ranee Anlst Date Time U -0.000522 Uncert: +/-0.0385 TPU: +/-0.0385 U 0.00 Uncert: +/-0.0756 TPU: +/-0.0756 U -0.0177 Uncert: +/-0.0764 TPU: +/-0.0765 12.8 Uncert: TPU: Uncert: TPU: 15.5 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 13.3 U -0.000522 Uncert: +/-0.0385 TPU: +/-0.0385 U 0.00 Uncert: +/-0.0756 TPU: +/-0.0756 16.1 U -0.0177 Uncert: +/-0.0764 TPU: +/-0.0765 U 0.0578+/-0.278+/-0.279 U -0.0405+/-0.0562+/-0.0565 U -0.0517+/-0.257+/-0.257 12.8+/- 1.84+/-2.70 U -0.0328+/-0.0454+/-0.0457 14.3+/-1.94+/-2.92 U 0.0471+/-0.157+/-0.157 U -0.0469+/-0.0459+/-0.0464 U -0.00385+/-0.210+/-0.210 pCi/g 204 pCi/g 200 pCi/g 98 pCi/g (0%- 100%) BXLI 08/11/06 14:34 (0%- 100%)(0%- 100%)100 (75%-125%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 92 (75%-125%)

U"12.0+/-1.38+/-2.08 0.0427+/-0.0837+/-0.0839 15.9+/-I.58+/-2.61 91 (75%-125%)

99 (75%-125%)

Batch 555697 QC1201153134 168340011 DUP Plutonium-238 U -0.0155 U 0.0237 pCi/g 956 (0%- 100%) BXLI 08/11/06 22:51 Page 100 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 2 of 6 Parmname NOM Sample Oual QC Units RPD% REC% Range AnIst Date Time Rad Alpha Spec Batch 555697 Plutonium-239/240 QC1201153136 LCS Plutonium-238 Plutonium-239/240 QC1201153133 MB Plutonium-238 Plutonium-239/240 QC1201153135 168340011 MS Plutonium-238 Uncert: +/-0.0215 TPU: +/-0.0216 U 0.0414 Uncert: +/-0.0934 TPU: +/-0.0935 Uncert: TPU: 11.8 Uncert: TPU: Uncert: TPU: Uncert: TPU: U -0.0155 Uncert: +/-0.0215 TPU: +/-0.0216 12.3 U 0.0414 Uncert: +/-0.0934 TPU: +/-0.0935 U 7.28 Uncert: +/-6.30 TPU: +/-6.35 U+/-0.0465+/-0.0466-0.0489+/-0.124+/-0.124 pCi/g 2410 (0% -100%)(75%-125%)

U 0.155+/-0.141+/-0.142 11.5+/-0.856+/-1.32 U 0.0552+/-0.186+/-0.186 U -0.0978+/-0.0892+/-0.0899 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 98 (75%-125%)

08/11/06 22:50 U 0.0539+/-0.112+/-0.112 10.3+/-0.796+/-1.19 (75%-125%)

08/11/06 22:51 Plutonium-239/240 84 (75%-125%)

Batch 555698 QC1201153138 168340011 DUP Plutonium-24 I QC1201153140 LCS Plutonium-241 QC1201153137 MB Plutonium-241 QC1201153139 168340011 MS Plutonium-241 U 10.1+/-6.39+/-6.46 pCi/g 0 (0% -100%) BXLI 137 Uncert: TPU: Uncert: TPU: 138 U Uncert: TPU: 145+/-12.5+/-19.9 U 8.57+/-6.93+/-6.98 pCi/g pCi/g pCi/g 106 (75%-125%)

08/16/06 16:41 08/16/06 17:14 08/16/06 16:25 08/16/06 16:58 7.28+/-6.30+/-6.35 Batch 557837 QC1201158317 168404009 DUP Americium-241 Curium-242 142+/-12.4+/-19.7 0.167+/-0.220+/-0.221 0.241 103 (75%-125%)

U -0.0851 Uncert: +/-0.136 TPU: +/-0.136 U -0.0253 U U pCi/g 616 pCi/g 247 (0%- 100%) BXLI 08/16/06 09:49 (0% -100%)Page 101 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 3 of 6 Parmname NOM Samnle Oual QC Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 557837 Curium-243/244 QC1201158319 Americium-241 Curium-242 Curium-243/244 QC1201158316 Americium-241 Uncert: +/-0.0495 TPU: +/-0.0496 U -0.0479 Uncert: +/-0.0542 TPU: +/-0.0545 LCS MB 24.5 Uncert: TPU: Uncert: TPU: 29.7 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.334+/-0.335 U 0.0761+/-0.149+/-0.149 25.4+/-2.47+/-4.16 U 0.0477+/-0.127+/-0.127 27.0+/-2.54+/-4.38 U 0.234+/-0.275+/-0.277 U 0.00+/-0.152+/-0.152 U -0.0551+/-0.0624+/-0.0628 29.1+/-2.97+/-5.01 U 0.126+/-0.247+/-0.248 31.7+/-3.12+/-5.39 pCi/g 879 Curium-242 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 91 (75%-125%)

(0% -100%)104 (75%-125%)

Curium-243/244 QC1201158318 Americium-241 168404009 MS Curium-242 26.4 Uncert: TPU Uncert: TPU 32.4 Uncert: TPU U -0.0851+/-0.136+/-0.136 U -0.0253+/-0.0495+/-0.0496 U -0.0479+/-0.0542+/-0.0545 110 (75%-125%)

Curium-243/244 98 (75%-125%)

Rad Gas Flow Batch 556350 QC1201154645 168404003 DUP Strontium-90 QC1201154647 LCS Strontium-90 U -0.00343 Uncert: +/-0.0203 TPU: +/-0.0203 1.56 Uncert: TPU: U -0.00637+/-0.0152+/-0.0152 1.30+/-0.0563+/-0.0881 U 0.0176+/-0.018+/-0.018 pCi/g 0 (0%- 100%) BXFI 08/14/06 08:33 pCi/g pCi/g 83 (75%-125%)

QC1201154644 MB Strontium-90 Uncert: TPU: Page 102 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 4 of 6 Parmname NOM Samnle Oual QC Units RPD%REC% Range AnIst Date Time NOM Rad Gas Flow Batch 556350 QC1201154646 168404003 MS Strontium-90 Rad Liquid Scintillation Batch 554580 QC1201150562 168340012 DUP Technetium-99 QCI201150564 LCS Technetium-99 1.58 U Uncert: TPU:-0.00343+/-0.0203+/-0.0203 U 0.0338 Uncert: +/-0.192 TPU: +/-0.192 U 1.29+/-0.0535+/-0.0813 0.266+/-0.226+/-0.226 13.6+/-0.496+/-0.599 pCi/g 82 (75%-125%)

pCi/g 0 (0% -100%) EGDI QC1201150561 MB Technetium-99 13.1 Uncert: TPU: Uncert: TPU: 13.0 U Uncert: TPU: U 0.0311+/-0.177+/-0.177 pCi/g pCi/g pCi/g 103 (75%-125%)

08/12/06 00:42 08/12/06 01:14 08/12/06 00:26 08/12/06 00:58 QC1201150563 168340012 MS Technetium-99 0.0338+/-0.192+/-0.192 12.0+/-0.523+/-0.602 92 (75%-125%)

Batch 554582 QC1201150570 168340011 DUP Tritium U 1.77 Uncert: +/-8.20 TPU: +/-8.20 U 1.62+/-7.47+/-7.47 pCi/g 0 (0% -100%) DFA I QC1201150572 LCS Tritium QCI201150569 MB Tritium 68.3 Uncert: TPU: Uncert: TPU: 61.3 U Uncert: TPU: 76.2+/-14.0+/-14.1 U 0.586+/-8.01+/-8.01 pCi/g pCi/g pCi/g 111 (75%-125%)

08/09/06 15:42 08/09/06 16:14 08/09/06 15:26 08/09/06 15:58 QC1201150571 168340011 MS Tritium 1.77+/-8.20+/-8.20 Batch 554583 QC1201150574 168404003 DUP Carbon-14 QC1201150576 LCS Carbon- 14 QC1201150573 MB U 0.0937 Uncert: +/-0.0813 TPU: +/-0.0813 I11 61.8+/-12.2+/-12.3 0.0422+/-0.075+/-0.0751 7.14+/-0.508+/-0.520 101 (75%-125%)

pCi/g pCi/g 0 (0% -100%) ATH2 08/10/06 01:39 08/10/06 03:00 7.27 Uncert: TPU: 98 (75%-125%)

Page 103 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

168404 Parmname Rad Liquid Scintillation Batch 554583 Carbon- 14 QC1201150575 168404003 MS Carbon- 14 Batch 555722 QC1201153223 168340012 DUP Iron-55 QC1201153225 LCS Iron-55 QC1201153222 MB Iron-55 QC1201153224 168340012 MS Iron-55 Batch 555723 QC1201153227 168340012 DUP Nickel-63 NOM Uncert: TPU 15.1 Uncert: TPU Uncert: TPU 641 Uncert: TPU Uncert: TPU 717 Uncert: TPU QC Summary Sample Qual QC U -0.0315+/-0.0776+/-0.0776 u 0.0937 13.8+/-0.0813

+/-1.00+/-0.0813

+/-1.03 U -26.5 U 5.83+/-65.1 +/-36.9+/-65.1 +/-36.9 660+/-56.2+/-67.2 U 18.2+/-39.6+/-39.6 U -26.5 688+/-65.1 +/-60.2+/-65.1 +/-71.6 U 3.79 U 6.68 Page 5 of 6 Units RPD% REC% Range Anist Date Time pCi/g pCi/g 92 (75%-125%)

08/10/06 02:43 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 0 (0% -100%) vlXP1 103 (75%-125%)

96 (75%-125%)

08/12/06 20:54 08/12/06 21:27 08/12/06 20:38 08/12/06 21:11 08/11/06 11:55 08/11/06 12:27 08/11/06 11:38 08/11/06 12:11 0 Uncert: +/-5.39 +/TPU: +/-5.40 +/QC1201153229 LCS Nickel-63 512 Uncert: +/TPU: +/QC1201153226 MB Nickel-63 U Uncert: +/TPU: +/QC1201153228 168340012 MS Nickel-63 530 U 3.79 Uncert: +/-5.39 +/TPU: +/-5.40 +/Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported Result is greater than value reported/-7.43'-7.43 479/-22.4'-27.1 15.7'-9.92'-9.93 511-23.5'-28.7 (0% -100%) vlXPI 94 (75%-125%)

96 (75%-125%)

Page 104 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 6 of 6 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.** Indicates analyte is a surrogate compound.^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.Page 105 of 105 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2b Split Sample Assessment Forms (2 Pages)

Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey 9106 Survey 0009 Survey Unit Discharge Canal Area#: Unit #: Name: Sample Plan or WPIR#: 2006-0021 SML #: 9106-0009-013 Sample

Description:

Comparison of split samples collected from sample measurement location #13 and analyzec using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0009-013F, thc comparison sample was 9106-0009-013FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)Cs-137 2.85E-02 1.45E-02 2 N/A 4.62E-02 2.76E-02 1.62 N/A Co-60 0.OOE+00 1.74E-02 0 N/A -2.78E-02 1.52E-02 N/A N/A Ni-63 -3.87E+00 4.53E+00 -1 N/A -9.09E+00 4.46E+00 2.35 N/A K-40 1.44E+01 6.65E-01 22 0.75 1.33 1.86E+01 6.25E-01 1.29 Y Comments/Corrective Actions: In consideration of the Cs-137, Table is provided to show acceptance criteria Co-60 and Ni-63 results, guidance for agreement ranges, used to assess split samples.obtained from USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination Resolution Agreement Range of acceptability for such rations cannot be made. Since K-40 4 7 0.50 2.00 was found to be present at an acceptable levels of agreement, no 8 15 0.60 1.66 further action is warranted.

16 50 0.75 1.33 51 200 0.80 1.25> 200 0.85 1.18 Performed By: Date: Reviewed By: Date:.tý &J yzVV'a/(-ýOz

ý ////1ID 6-WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation Page I of I Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey Area Survey 0009 Survey Discharge Canal#: 9106 Unit #: UnitName: Sample Plan or WPIR#: 2006-021 SML #: 9106-0009-016 Sample

Description:

Comparison of split samples collected from sample measurement location #16 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0009-016F the comparison sample was 9106-0009-016FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)Cs-137 1.70E-01 2.17E-02 8 0.6 1.66 2.31E-01 2.08E-02 1.36 Y Co-60 2.39E-01 2.33E-02 10 0.6- 1.66 2.77E-01 3.05E-02 1.16 Y Ni-63 -6.30E+00 4.32E+00 -1 N/A -1.18E+01 4'.58E+00 1.87 N/A K-40 1.44E+01 6.65E-01 22 0.75 1.33 1.30E+01 6.25E-01 0.90 Y Comments/Corrective Actions: In consideration of the Ni-63 results, guidance for agreement ranges, obtained from USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such rations cannot be made. Since Cs-137, Co-60 and K-40 were found to be present at an acceptable levels of agreement, no further action is warranted.

Table is provided to show acceptance criteria used to assess split samples.Resolution Agreement Range 4 8 16 51 7 15 50 200> 200 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 Performed By: Date: 10o-31 -04 Reviewed By: a WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation Page I of I DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2c Preliminary Data Form (1 Page)

Health Physics Procedure GPP-GGGR-R5121-001 Attachment B, Rev. CY-001 MAJOR Health Physics Procedure GPP-GGGR-R5 121-001 Attachment B, Rev. CY-00 1 MAJOR Preliminary Data Review Form -Samples for the Sign Test Survey Unit: 9106- 0009 Survey Unit Name: Discharge Canal Classification:

2 Survey Media: Soil Type of Survey: Final Status Survey Type of Measurement:

Gross Measurement Number of Measurements:

Operational DCGL: 15 1 BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Ni-63 Minimum Value: -5.66E-03

-2.33E-02

-1.36E+01 Maximum Value: 5.27E-01 9.04E-01 -1.97E+00 Mean: 1.71E-01 2.03E-01 -8.12E+00 Median: 1.65E-01 1.06E-01 -7.67E+00 Standard Deviation:

1.60E-01 2.58E-01 4.05E+00 RADIONUCLIDE CONCENTRATION (pCi/g)NUMBER 9106-0009-001F 9106-0009-002F 9106-0009-003F 9106-0009-004F 9106-0009-005F 9106-0009-007F 9106-0009-008F 9106-0009-009F 9106-0009-01 OF 9106-0009-01 IF 9106-0009-013F 9106-0009-014F 9106-0009-015F 9106-0009-016F 9106-0009-017F Cs-137 1.65E-01 5.27E-01 O.OOE+00-5.66E-03 1.91E-01 1.03E-01 3.72E-02 3.97E-01 1.56E-01 2.14E-03 2.85E-02 2.17E-01 1.86E-01 1.70E-01 3.88E-01 Co-60 1.18E-01 9.04E-01 1.52E-02 1.99E-02 1.06E-01 6.71 E-02 4.83E-02 4.58E-01 1.53E-01-2.33E-02 O.OOE+0O 6.26E-02 3.34E-01 2.39E-01 5.37E-01 Ni-63-1.97E+00-1.20E+01-7.67E+00-2.23E+00-1.30E+01-1.36E+01-1.29E+01-7.24E+00-4.44E+00-1.23E+01-3.87E+00-1.04E+01-8.35E+00-6.30E+00-5.48E+00 Identified?

Y Y N N Y Y Y Y Y N N Y Y Y Y Identified?

Y Y N N Y Y Y Y Y N N Y Y Y Y Identified?

N N N N N N N N N N N N N N N Performed By: Independent Review: fM 2 X. ý-Date: #-/- 0,ýDate:

DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2d Graphical Representation of Data (6 Pages)

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cesium -137 Survey Unit: 9106-0009 Survey Unit Name: Discharge Canal Mean: 1.71E-01 pCi!g 6.OOE-01 ,, 5.OOE-01 --O 4.OOE-01 , * -0 3.OOE-01-.......

., 2.OOE-01 ----*=o1.00E-01

  • " '0 C) .OOE+OO

--20 40 60' 80 "1q Percentage Cs-1 37 Rank Percentage

-5.66E-03 1 3 %0.OOE+00 2 10 %2.14E-03 3 17 %2.85E-02 4 23 %3.72E-02 5 30 %1.03E-01 6 37 %1.56E-01 7 43 %1.65E-01 8 50 %1.70E-01 9 57 %1.86E-01 10 63 %1.91E-01 11 70%2.17E-01 12 77 %3.88E-01 13 83 %3.97E-01 14 90 %5.27E-01 15 97 %Prepared By: Reviewed By: Date: -Oz Date: ///,_

Quantile Plot For Cobalt -60 Survey Unit: Survey Unit Name: Mean: 9106-0009 Discharge Canal 2.03E-01 pCi/g 1.OOE+00.. 8.OOE-01 c 6.OOE-01 0 4.00E-01 o 2.OOE-01 --0 "0 0 0.00E+00 * -* ----2'0 40 60 8 1e0 Percentage Co-60 Rank Percentage

-2.33E-02 1 3 %0.OOE+00 2 10 %1.52E-02 3 17 %1.99E-02 4 23 %4.83E-02 5 30 %6.26E-02 6 37 %6.71 E-02 7 43 %1.06E-01 8 50 %1.18E-01 9 57 %1.53E-01 10 63 %2.39E-01 11 70 %3.34E-01 12 77 %4.58E-01 13 83 %5.37E-01 14 90 %9.04E-01 15 97 %#2,1 I-V"" zo, Prepared By: , Reviewed By: , Date: //- -,9/Date: /1 /-! tb Health Physics Procedure GGGR-R5123-Rev.CY-001 Attaclunent C Quantile Plot For Nickel-63 Survey Unit: 9106-0009 Survey Unit Name: Discharge Canal Mean: -8.12E+00 pCi/g 0.OOE+00-2.OOE+00 20 40 6, 80-4.OOE+O0

--0.-6.00E+00"- -8.OOE+0 1.20E+01

--1.40E+01

--1.60E+01

_-Percentage Ni-63 Rank Percentage

-1.36E+01 1 3 %-1.30E+01 2 10 %-1.29E+01 3 17 %-1.23E+01 4 23 %-1.20E+01 5 30 %-1.04E+01 6 37%-8.35E+00 7 43 %-7.67E+00 8 50 %-7.24E+00 9 57 %-6.30E+00 10 63 %-5.48E+00 11 70 %-4.44E+00 12 77 %-3.87E+00 13 83 %-2.23E+00 14 90 %-1.97E+00 15 97 %Prepared By: Reviewed By: Date: /( -j'- ",1 Date: ii /D Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cesium-137 Survey Unit: 9106-0009 Survey Unit Name: Discharge Canal Mean: 0.171 pCi/g C.)d)LL 7 6 5 4 3 2 1 0 I--K---I 0.00 0.10 0.20 0.30 0.40 0.50 0.60 Upper End Value (pCi/g)Upper End Observation Observation

%Value Frequency Frequency 0.00 2 13%0.10 3 20%0.20 6 40%0.30 1 7%0.40 2 13%0.50 0 0%0.60 1 7%Total 15 100%Prepared By: Date: / )--- 0, Reviewed By: Date: z/"/, o, Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cobalt-60 Survey Unit: 9106-0009 Survey Unit Name: Discharge Canal Mean: 0.203 pCi/g Upper End Observation Observation

%Value Frequency Frequency 0.00 2 13%0.20 8 53%0.40 2 13%0.60 2 13%0.80 0 0%1.00 1 7%Total 15 100%Prepared By:-ý '44ýDate: / -3/-Q Date: /1 .16 Reviewed By:/7 Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Nickel-63 Survey Unit: 9106-0009 Survey Unit Name: Discharge Canal Mean: -8.117 pCi/g 6 5 4--4"m 2 0*-12 8 4 -2 0 Upper End Value (pCi/g)Upper End Observation Observation

%Value Frequency Frequency-12 5 33%-10 1 7%-8 1 7%-6 3 20%-4 2 13%-2 2 13%0 1 7%Total 15 100%Prepared By: Date: #-/-az Reviewed By: Date: Il / 4 7 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2e Sign Test Calculation (1 Page)

Health Physics Procedure GPP-GGGR-R5121-000 Attachment A, Rev. CY-001 MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes Survey Unit Number: 9106-0009 Survey Unit Name: Discharge Canal WP&IR#: 2006-021 Classification

2 [ TYPE I (a error):0.05 I TYPE I (P3 error):0.05[

Radionuclides:

Cs-137 Co-60 Ni-63 Survey Design DCGL (pCi/g): 6.01 2.9 549 Results Cs-137 Results Co-60 Results Ni-63 Weighted Sum (W,) DCGL-Result Sign 1.65E-01 1.18E-01 1.18E-01 1.24E-01 8.76E-0I* 5.27E-01 9.04E-01 9.04E-01 3.91E-01 6.09E-01 0.00E+00 1.52E-02 1.52E-02 5.05E-02 9.49E-01-5.66E-03 1.99E-02 1.99E-02 6.11E-02 9.39E-01 1.91E-01 1.06E-01 1.06E-01 1.04E-01 8.96E-01 1.03E-01 6.71 E-02 6.71E-02 7.48E-02 9.25E-01 3.72E-02 4.83E-02 4.83E-02 5.86E-02 9.41E-01 3.97E-01 4.58E-01 4.58E-01 2.70E-01 7.30E-01 1.56E-01 1.53E-01 1.53E-01 1.30E-01 8.70E-01 2.14E-03 -2.33E-02

-2.33E-02 4.49E-02 9.55E-01 2.85E-02 0.OOE+00 0.OOE+00 5.70E-02 9.43 E-01 2.17E-01 6.26E-02 6.26E-02 1.89E-01 8.11E-01 1.86E-01 3.34E-01 3.34E-01 1.90E-01 8.10E-01 1.70E-01 2.39E-01 2.39E-01 1.59E-01 8.41E-01 3.88E-01 5.37E-01 5.37E-01 2.38E-01 7.62E-01 Number of Positive Differences (S+): 15 Critical Value: 11 Survey Unit: Meets Acceptance Criterion Performed By: Date: */( -/-Q~2 Independent Review: Date: 4 16,;Note Weighted Sum values i des HTD components.

See Compass run for more detail.Page 1 of 1 DISCHARGE CANAL SURVEY UNIT 9106-0009 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (4 Pages)

DQA Surface Soil Report Assessment Summary Site: Planner(s):

Survey Unit Name: Report Number: Survey Unit Samples: Reference Area Samples: Test Performed:

Judgmental Samples: Assessment

==

Conclusion:==

9106-0009 (19mrem/yr)

Dale Randall 9106-0009 1 15 0 Sign Test Result: Not Performed 0 EMC Result: Not Performed Reject Null Hypothesis (Survey Unit PASSES)Retrospective Power Curve U.4-=I-C, 4 1~1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 zJ~zz_ _-_--71-I-* zzI~z ______ ___ -____________ ___ ii zii! ______ ___ ______* ______ ___ -Zilijili zz!~z ______ --I:- --zizzii[-Ii- -~_ztIz ______ ---.1:---______ ---4 iizIizzz ______ ______ --______0.0 0.2 0.4 0.6 0.8 1.0 Unity Rule Sum-of-Ratios, including background

--Prospective Power I 1-beta ....Actual Power ,,- LBGR --Estimated Power i DCGL ---- Retrospective Power 1.2 COMPASS vl.0.0 1013112006 Page I DQA Surface Soil Report Survey Unit Data NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0009-001 F 9106-0009-002F 9106-0009-003F 9106-0009-004F 9106-0009-005F 9106-0009-007F 9106-0009-008F 9106-0009-009F 9106-0009-01OF 9106-0009-011 F 9106-0009-013F 9106-0009-014F 9106-0009-015F 9106-0009-016F 9106-0009-017F Sample Number 9106-0009-001 F 9106-0009-002F 9106-0009-003F 9106-0009-004F 9106-0009-005F 9106-0009-007F 9106-0009-008F 9106-0009-009F 9106-0009-01 OF 9106-0009-011 F 9106-0009-013F 9106-0009-014F 9106-0009-015F 9106-0009-016F 9106-0009-017F Type S S S S S S S S S S S S S S S Cm-244 (pCi/g)0.33 0.01 0.33 0.33 0.33 0.33 0.33 0.33 0.33 1.39 0.33 0 0.33 0.33-0.07 Co-60 (pCi/g)0.12 0.9 0.02 0.02 0.11 0.07 0.05 0.46 0.15-0.02 0 0.06 0.33 0.24 0.54 Cs-137 (pCi/g)0.16 0.53 0-0.01 0.19 0.1 0.04 0.4 0.16 0 0.03 0.22 0.19 0.17 0.39 Type S S S S S S S S S S S S S S S H-3 (pCi/g)13.82 4.12 13.82 13.82 13.82 13.82 13.82 13.82 13.82 3.69 13.82 46.9 13.82 13.82 0.58 Ni-63 (pCi/g)-1.97-12-7.67-2.23-13-13.6-12.9-7.24-4.44-12.3-3.87-10.4-8.35-6.3-5.48 COMPASS vI.0.0 1013112006 Page 2

'IWJ DQA Surface Soil Report Modified Data (Unity Rule SOR)NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0009-001 F 9106-0009-002F 9106-0009-003F 9106-0009-004F 9106-0009-005F 9106-0009-007F 9106-0009-008F 9106-0009-009F 9106-0009-01 OF 9106-0009-011 F 9106-0009-013F 9106-0009-014F 9106-0009-015F 9106-0009-016F 9106-0009-017F Type S S S S S S S S S S S S S S S Sum-of-Ratios (SOR)0.12 0.39 0.05 0.06 0.1 0.07 0.06 0.27 0.13 0.05 0.06 0.19 0.19 0.16 0.24 COMPASS vI.0.P 10/3112006 Page 3 DQA Surface Soil Report Basic Statistical Quantities Summary Statistic Survey Unit Background DQO Results Sample Number 15 N/A N=13 Mean (SOR) 0.14. N/A 0.09 Median (SOR) 0.12 N/A N/A Std Dev (SOR) 0.10 N/A 0.07 High Value (SOR) 0.39 N/A N/A Low Value (SOR) 0.05 N/A N/A COMPASS vl.0.0 10/3112006 Page 4