Registration of Use of Cask to Store Spent Fuel
ML17284A080
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 10/11/2017
From: Vinyard H
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
RA17-082
Download: ML17284A080 (2)


Text

Exelon Generation RA17-082 October 11, 2017 ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 LaSalle County Station, Units 1 and 2 10 CFR 72.212 Renewed Facility Operating License Nos. NPF-11 and NPF-18 NRC Docket Nos. 50-373. 50-374, and 72-70

Subject:

Registration of Use of Cask to Store Spent Fuel LaSalle County Station 2601 North 21*1 Road Marseilles, IL 61341 815-415-2000 Telephone www exeloncorp.com In accordance with 1 O CFR 72.212, "Conditions of general license issued under 1 O CFR 72.21 O," paragraph (b)(2), LaSalle County Station is registering with the NRC the use of one cask under the general license to store spent fuel. The initial use of the cask listed below to store spent fuel occurred on September 13, 2017. This registration is required to be submitted within 30 days. Accordingly, this submittal is due by October 13, 2017. The following information is provided in accordance with 1 O CFR 72.212(b)(2):

Licensee Name and Address Reactor Licenses and Docket Numbers Independent Spent Fuel Storage Installation Docket Number Contact Person Name and Title Cask Certificate Number Cask Model Number Exelon Generation Company, LLC 2601 N. 21 51 Road Marseilles, IL 61341 NPF-11 and NPF-18 50-373 and 50-37 4 72-70 Guy V. Ford, Jr. Regulatory Assurance Manager 1014, Amendment 8 Revision 1 HI-STORM 1 OOS October 11, 2017 U.S. Nuclear Regulatory Commission Page 2 Service Date: Cask Identification Number: September 13, 2017 Multi-Purpose Canister Type 68M, S/N: 0456 HI-STORM 1 OOS, S/N: 0803 There are no regulatory commitments contained in this submittal.

Should you have any questions concerning this submittal, please contact Mr. Guy V. Ford, Jr., Regulatory Assurance Manager, at (815) 415-2800.

Harold Vinyard Plant Manager LaSalle County Station cc: Regional Administrator

-NRC Region Ill NRC Senior Resident Inspector

-LaSalle County Station