RA21-052, Registration of Use of Cask Store Spent Fuel

From kanterella
Jump to navigation Jump to search
Registration of Use of Cask Store Spent Fuel
ML21259A037
Person / Time
Site: LaSalle  
Issue date: 09/17/2021
From: Van Fleet J
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
RA21-052
Download: ML21259A037 (2)


Text

Lasalle CountyStation i

=

815-415-2000 Telephone wwwexeloncorp com RA21-052 10CFR72.212 September 16,2021 ATTN:Document Control Desk

Director, Division ofSpentFuel Management Office ofNuclear Material Safety and Safeguards U.S.Nuclear Regulatory Commission Washington, DC20555-0001 LaSalle County
Station, Units 1and2 Renewed Facility OperatingLicense Nos.NPF-11andNPF-18

Subject:

Registration ofUseofCasktoStore Spent Fuel Inaccordance with10CFR72.212, "Conditions ofgeneral license issued under 10CFR 72.210,"

paragraph (b)(2),

LaSalle County Station isregistering withtheNRCtheuseofthree casks under thegeneral license tostore spent fuel.

Theinitial use ofthecasks listed below to store spent fuel occurred onAugust 19,2021;August 26,2021;and September 2,2021,as indicated below.

Thisregistration isrequired tobesubmitted within 30 days.

Accordingly, this submittal isduebySeptember 18,2021, Thefollowing information isprovided inaccordance with10CFR72.212(b)(2):

Licensee NameandAddress Exelon Generation

Company, LLC 2601N.21St Road Marseilles, IL61341 Reactor Licenses and NPF-11andNPF-18 Docket Numbers 50-373 and50-374 Independent Spent FuelStorage Installation Docket Number 72-70 Contact Person NameandTitle DanMearhoff, Regulatory Assurance Manager CaskCertificate Number 1014,Amendment 8Revision 1

CaskModelNumber HI-STORM 100S

September 16,2021 U.S.

Nuclear Regulatory Commission Page 2 ServiceDate:

August 19,2021 Cask Identification Number:

Multi-Purpose Canister Type68M,S/N:0603 HI-STORM 100S,S/N:1124 Service Date:

August 26,2021 CaskIdentification Number:

Multi-Purpose Canister Type68M,S/N:

0665 HI-STORM 100S,S/N:1257 Service Date:

September 2,2021 CaskIdentification Number:

Multi-Purpose Canister Type68M,S/N:

0666 HI-STORM 100S,S/N:1258 Therearenoregulatory commitments contained inthissubmittal. Should youhaveanyquestions concerning this submittal, please contact Mr.

Dan

Mearhoff, RegulatoryAssurance
Manager, at (815) 415-2800.

Respectfully, JohnVanFleet Plant Manager LaSalle County Station cc: Regional Administrator

- NRCRegion III NRCSenior Resident Inspector

- LaSalle County Station