MONTHYEARML24038A0222024-02-0505 February 2024 Achp Letter on Section 106 Programmatic Agreement Participation IR 05000289/20230062024-01-29029 January 2024 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report No. 05000289/2023006 ML23342A1242024-01-0909 January 2024 Independent Spent Fuel Storage Installation Security Inspection Plan ML23325A1092024-01-0505 January 2024 Review of the Management Plan for Three Mile Island Station, Unit No. 2, Debris Material ML23354A2062023-12-20020 December 2023 (TMI-2), Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23354A2112023-12-20020 December 2023 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 IR 05000320/20230032023-11-28028 November 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2, NRC Inspection Report No. 05000320/2023003 ML23243A9082023-08-29029 August 2023 Shpo Letter to TMI-2 Regarding Section 106 Activities IR 05000320/20230022023-08-17017 August 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2023002 ML23216A1742023-08-14014 August 2023 Consultation Letter to David Morrison for TMI-2 ML23216A1772023-08-14014 August 2023 Consultation Letter to Rebecca Countess for TMI-2 ML23216A1752023-08-14014 August 2023 Consultation Letter to Joanna Cain for TMI-2 ML23216A1732023-08-14014 August 2023 Consultation Letter to Christine Turner for TMI-2 IR 05000289/20230052023-08-14014 August 2023 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report 05000289/2023005 ML23216A1782023-08-14014 August 2023 Consultation Letter to Steve Letavic for TMI-2 ML23221A1402023-08-0808 August 2023 (TMI-2), Response to Requests for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 ML23200A1882023-07-31031 July 2023 TMI-2 Correction Letter Amendment 67 ML23209A7632023-07-28028 July 2023 Letter from PA Shpo to TMI-2 Solutions on Cultural and Historic Impacts of Decommissioning ML23192A8272023-07-10010 July 2023 TMI-2 Solutions, LLC - Response to Shpo Request for Additional Information for Er Project 2021PR03278.006, TMI-2 Decommissioning Project ML23167A4642023-07-0505 July 2023 Letter - TMI-2- Exemption 10 CFR Part 20 Append G Issuance ML23167A0312023-06-28028 June 2023 Acceptance Review and Schedule for the Request for Exemption from a Requirement from 10 CFR 20, Appendix G, Section Iii.E, EPID L-2023-LLE-0016 ML23171B0222023-06-19019 June 2023 (TMI-2) - Notification Pursuant to 10 CFR 72.140(d) Regarding Application of Previously Approved TMI-2 Quality Assurance Program to Independent Spent Fuel Storage Installation Activities ML23137A2822023-05-17017 May 2023 (TMI-2), Request for Exemption from 10 CFR 20, Appendix G, Section Iii.E ML23138A0662023-05-17017 May 2023 TMI-2 NHPA Section 106 Shpo Letter to NRC 5-17-23 ML23026A3132023-05-0202 May 2023 Issuance of Exemption from 10 CFR 70.24 (EPID-L-2023-LLE-0003) ML23122A1842023-05-0101 May 2023 Shpo_Er_Summary_Letter ML23121A2492023-05-0101 May 2023 License Amendment Request, Historic and Cultural Resources Review, Response to Request for Additional Information ML23117A0012023-04-26026 April 2023 Commitment Revision Summary Report ML23027A0832023-04-24024 April 2023 Environmental Assessment/Finding of No Significant Impact - Request for Exemption from 10 CFR 70.24 ML23108A0802023-04-18018 April 2023 Annual Radiological Effluent Release Report ML23108A0822023-04-18018 April 2023 Annual Radiological Environmental Operating Report IR 05000320/20230012023-04-12012 April 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report No. 05000320/2023001 ML23102A0382023-04-10010 April 2023 Occupational Radiation Exposure Annual Report ML23108A2002023-04-10010 April 2023 CFR 20.2206(b) Personnel Radiation Exposure Report for 2022 ML23094A2582023-04-0606 April 2023 Letter to Sidney Hill, Chief, Onondaga Nation, Re., Initiation of Consultation Under Section 106 of the NHPA for the Proposed License Amendment Request for TMI 2 ML23093A0572023-04-0606 April 2023 Letter to Joanna Cain, President, Re., Ongoing Activities Related to the Proposed License Amendment Request for Three Mile Island Nuclear Station, Unit 2 ML23094A2362023-04-0606 April 2023 Letter to Carissa Speck, Re., Initiation of Consultation Under Section 106 of the NHPA for the Proposed License Amendment Request for Three Mile Island Nuclear Station, Unit 2 ML23094A2542023-04-0606 April 2023 Ltr J Bendremer Thpo Stockbridge-Munsee Community Band of Mohican Indians Re Initiation of Consultation Under Section 106 of the NHPA for Proposed License Amendment Request for TMI 2 ML23086C0652023-04-0606 April 2023 Ltr Larry Heady, Thpo, De. Tribe of Indian; Re., Initiation of Consultation Under Section 106 of the NHPA for the Proposed License Amendment Request for TMI Nuclear Station, Unit 2 ML23093A0562023-04-0606 April 2023 Letter to Steve Minnick, Site Decommissioning Director, Re., Ongoing Activities Related to the Proposed License Amendment Request for Three Mile Island Nuclear Station, Unit 2 ML23094A2602023-04-0606 April 2023 Letter to William Tarrant, Seneca-Cayuga Nation, Re., Initiation of Consultation Under Section 106 of the NHPA for the Proposed License Amendment Request for TMI 2 ML23094A2392023-04-0606 April 2023 Letter to Courtney Gerzetich, Thpo, Onedia Nation of Wisconsin, Re., Initiation of Consultation Under Section 106 of the NHPA for the Proposed License Amendment Request for TMI 2 ML23093A0592023-04-0606 April 2023 Letter to Rebecca Countess, Chair, Re., Ongoing Activities Related to the Proposed License Amendment Request for Three Mile Island Nuclear Station, Unit 2 2024-02-05
[Table view] |
Text
10 CFR 50.55a TMI*12*070 April 18, 2012 U.S.Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555*0001 Three Mile Island Nuclear Station, Unit 1 Renewed Facility Operating License No.DPR*50 NRC Docket No.50*289
Subject:
Relief Request PR*05 Associated with the Fourth Inservice Testing (1ST)Interval
References:
1)Letter from M.Jesse (Exelon Generation Company, LLC)to U.S.Nuclear Regulatory Commission,"Submittal of Relief Request PR*05 Associated with the Fourth Inservice Testing (1ST)Interval," dated October 28,2011 2)Letter from P.Bamford (U.S.Nuclear Regulatory Commission) to M.Pacilio (Exelon Generation Company, LLC),"Three Mile Island Nuclear Station, Unit 1.Request for Additional Information Regarding Relief Request PR*05, Relief Request Associated with Fourth Inservice Testing Interval (TAC NO.ME7532)," dated April 4, 2012 In the Reference 1 letter, Exelon Generation Company, LLC submittedarelief request associated with the fourth Inservice Testing (1ST)ten*year interval for Three Mile Island Nuclear Station (TMI), Unit 1.TMI, Unit 1 requested relief to perform alternative testing of the Reactor Building Emergency Cooling River Water pumps.In the Reference 2 letter, the U.S.Nuclear Regulatory Commission requested additional information.
Attached is our response to this request.There are no regulatory commitments in this letter.If you have any questions conceming this letter, please contact Tom Loomis at (610)765*5510.RespectfUlly, Michael D.Jesse Director*Licensig&gulatory Affairs Exelon Generati mpany, LLC Relief Request PR-05 Associated with the Fourth Inservice Testing (1ST)Interval April 18, 2012 Page 2
Attachment:
Response to Request for Additional Information
-Relief Request PR-05 cc: Regional Administrator, Region I, USNRC USNRC Senior Resident Inspector, TMI USNRC Project Manager,[TMI]USNRC Attachment Response to Request for Additional Information*
Relief Request PR*05 Response to Request for Additional InformationRelief Request Page 1 Question:Request for Additional Information:
Does the test proposed in your submittal use a fixed system resistance to establish a repeatable reference condition and then measure, record, and evaluate pump differential pressure to assess pump performance trends?If so, then this approach does not appear to the NRC technical staff to be a deviation from the requirements of OM Code and, therefore, does not require relief.Please note that NRC regional inspection staff have previously reached a similar conclusion regarding testing of these pumps as documented in Inspection Report No.050000289/2004004, dated November 8, 2004 (ADAMS Accession No.ML043150481).
Also please note that, interpretation of ASME OM Code requirements is the purview of the ASME Committee on Operations and Maintenance and, if needed, their inquiry process is available for assistance in clarifying OM Code requirements." Response: Following additional review of the ASME OM Code and the conclusions in Inspection Report No.0500028912004004, Exelon Generation Company, LLC (Exelon)agrees that the proposed testing of Reactor Building Emergency Cooling River Water Pumps AlB meets the intent of the ASME OM Code for a Group B pump test and adequately monitors pump performance and therefore this relief request is not needed.The test condition is at a substantial, repeatable flow at the"readily duplicated" reference point.Pump performance is then evaluated between comprehensive pump tests by the trends of differential pressure.In view of this information, Exelon hereby withdraws this relief request.