RA06-058, Surveillance Capsule Removal

From kanterella
Revision as of 18:09, 10 February 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Surveillance Capsule Removal
ML062700181
Person / Time
Site: LaSalle Constellation icon.png
Issue date: 08/31/2006
From: Enright D J
Exelon Generation Co, Exelon Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RA06-058
Download: ML062700181 (2)


Text

~Exel j,n.Exelon Generation Company, LLC www.exeloncorp.com NEucleaT LaSalle County Station 2601 North 21't Road Marseilles, I L 61341-9757 RA06-058 August 31, 2006 United States Nuclear Regulatory Commission Attention:

Document Control Desk Washington, D.C. 20555 LaSalle County Station, Unit 2 Facility Operating License No. NPF-18 NRC Docket No. 50-374

Subject:

LaSalle Unit 2 Surveillance Capsule Removal

References:

1. BWRVIP-86A, "BWR Vessel and Internals Project, Updated BWR Integrated Surveillance Program (ISP) Implementation Plan" 2. August 13, 2003 letter from William A. Macon (USNRC) to John L.Skolds (Exelon), LaSalle County Station -Units 1 and 2 -Issuance of Amendment LaSalle County Station (LCS) License Amendment 146 authorized the use of the Boiling Water Reactor Vessel and Internals Project (BWRVIP) reactor pressure vessel Integrated Surveillance Program (ISP) as the basis for demonstrating compliance of LaSalle Unit 2 with the requirements of Appendix H to 10 CFR Part 50 [Reference 2]. The ISP is discussed in detail in Reference 1.During the Unit 2 Spring 2005 outage at LaSalle, the surveillance capsule holder, containing surveillance plate C9481-1 and the surveillance weld 5P7397, at the 1200 azimuth moved from its design location.

The spring inside the capsule holder failed which allowed the capsule holder to extend to its total length. In addition to the capsule holder extending to full length, the flow in the annulus has dislodged the bottom of the capsule holder out to the end of the capsule holder bracket attachment.

LaSalle County Station plans to remove this surveillance capsule from the reactor during the next Unit 2 outage, scheduled for February 2007. In accordance with the requirements of NUREG-1 801,Section XI.M31, Generic Aging Lessons Learned (GALL) Report, LCS will store the surveillance capsule and specimens contained within the capsule in the fuel pool indefinitely.

The Unit 2 surveillance capsule will have been in the reactor approximately 15.44 Effective Full Power Years (EFPY).A090 August 31, 2006 U.S. Nuclear Regulatory Commission Page 2 Indefinite storage of non-ISP capsules is consistent with the process agreed to by the NRC and the BWRVIP. This approach is technically justified for the following reasons: " LaSalle Unit 2 is not a host plant in the Integrated Surveillance Program (ISP)." The LaSalle Unit 2 capsules do not provide valuable information to the BWR fleet;the surveillance plate C9481-1 and the surveillance weld 5P7397 are not limiting plate or weld materials in the ISP." The Unit 2 capsule and its surveillance specimens will remain available in the fuel pool indefinitely should they be needed for any unforeseen contingency.

This letter is being transmitted for information only and Exelon Generation Company is not requesting any action from the NRC staff.Should you have any questions concerning this letter, please contact Mr. Terrence W. Simpkin, Regulatory Assurance Manager, at (815) 415-2800.Respectfully, Daniel J. Enright Plant Manager LaSalle County Station cc: Regional Administrator

-NRC Region III NRC Senior Resident Inspector

-LaSalle County Station NRR Project Manager, NRR -LaSalle County Station, Units I and 2 NRC BWRVIP Project Manager EPRI BWRVIP Project Manager