ML063170083

From kanterella
Revision as of 16:50, 10 February 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search

Technical Specification, 2.0 Safety Limits
ML063170083
Person / Time
Site: Dresden Constellation icon.png
Issue date: 11/07/2006
From: John Honcharik
NRC/NRR/ADRO/DORL/LPLIII-2
To: Crane C M
Exelon Generation Co
Williams J F, NRR/DLPM/LPD1, 415-1470
Shared Package
ml062990294 List:
References
TAC MD2706
Download: ML063170083 (1)


Text

SLs 2.0 2.0 SAFETY LIMITS (SLs)2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10% rated core flow: THERMAL POWER shall be s 25% RTP.2.1.1.2 With the reactor steam dome pressure 785 psig and core flow 10% rated core flow: For Unit 2 be 1.11, MCPR shall For Unit 3 be 1.12, MCPR shall two recirculation loop operation, MCPR shall or for single recirculation loop operation, be 1.12.two recirculation loop operation, MCPR shall or for single recirculation loop operation, be R t e 1.14.I 2.1.1.3 Reactor vessel water level shall be greater than the top of. active irradiated fuel.2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be : 1345 psig.2.2 SL Violations With any SL violation, the following actions shall be completed within.2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s: 2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.Dresden 2 and 3 2.0-1 Amendment No. 199/213