RCS PST Limits 3.4.9 0
0 w
0 I-
-Iw CD w
0 C.
w U,
0.
1400 1300 1200 1100 1000 900 Boo 700 600 500 400 300 200 100 0
H EATUP/COOLDOWN RATE OF COOLANT 5 20'F/HR UPPER VESSEL AND BELTLINE LIMITS BOTTOM HEAD CURVE 0
25 50 75 100 125 150 175 200 MINIMUM REACTOR VESSEL METAL TEMPERATURE (fF)
Figure 3.4.9-1 (Page 1 of 1)
Non-Nuclear Inservice Leak and Hydrostatic Testing Curve (Valid to 54 EFPY)
I Dresden 2 and 3
- 3. 4. 9-6 Amendment No. 217, 209
RCS PST Limits 3.4.9 1400 1300 1200 1100 Uj Or& Soo 0
-I LU a w
0 700 a:
600 z
X 50 0
'U ir,'
400
'U 300 200 100 0
I HEATUPICOOLDOWN RATE OF COOLANT s 1OOF/HR I UPPER VESSEL AND BELTLINE LIMITS BOTTOM HEAD CURVE 0
25 50 75 100 125 150 175 200 MINIMUM REACTOR VESSEL METAL TEMPERATURE
_. (F)
Figure 3.4.9-2 (Page 1 of 1)
Non-Nuclear Heatup/Cooldown Curve (Valid to 54 EFPY)
I Dresden 2 and 3 3.4.9-7 Amendment No. 217, 209
RCS P/T Limits 3.4.9 CD I-0P-I-j w9 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0
HEATUP/COOLDOWN RATE OF COOLANT c 100SF/HR BELTLINE AND NON-BELTLINE LIMITS o
25 50 75 100 125 150 176 20D 225 250 M.lINIMU M REACTOR VESSEL METAL TEMPERATURE
('F)
Figure 3.4.9-3 (Page 1 of 1)
Critical Operations Curve (Valid to 54 EFPY)
I Dresden 2 and 3 3.4.9 -8 Amendment No. 217, 209
RCS P/T Limits 3.4.9 1400 1300 1200 1100 laIn L) 0 w
z a_
0
-jw UJ Cn U) w 0
0 w
z w
U, w
a:
a.
1000 900 800 700 600 500 400 HEATUPICOOLDOWN RATE OF COOLANT
< 200F/HR UPPER VESSEL AND BELTLINE LIMITS
.BOTTOM HEAD CURVE 300 200 100 0
0 25 50 75 100 125 150 175 200 MINIMUM REACTOR VESSEL METAL TEMPERATURE (0F)
Figure 3.4.9-1 (Page 1 of 1)
Non-Nuclear Inservice Leak and Hydrostatic Testing Curve (Valid to 54 EFPY)
Quad Cities I and 2 3.4.9-6 Amendment No.228, 223
RCS P/T Limits 3.4.9 1400 1300 1200 1100 D
1000 w
I
- 0.
900 0
-j U) 800 U) o 700 LU 3
600 2 500 1U U) 400 U) trk aL 300 200 100 HEATUP/COOLDOWN RATE OF COOLANT
< 1000 F/HR UPPER VESSEL AND BELTILINE LIMITS BOTTOM HEAD CURVE 0
0 25 50 75 100 125 150 175 200 MINIMUM REACTOR VESSEL METAL TEMPERATURE (CF)
Figure 3.4.9-2 (Page 1 of 1)
Non-Nuclear Heatup/Cooldown Curve (Valid to 54 EFPY)
I Quad Ci ti es l and 2 3.4.9-7 Amendment No.
228, 223
RCS P/T Limits 3.4.9 1400 1300 1200 1100 i
1000 C-900 0I-
-jwcn 500 U)
CII o
700 v
M 600 z
500 w
400 a..
300 200 100 0
HEATUP/COOLDOWN RATE OF COOLANT E 1000F/HR BELTLINE AND NON-BELTLINE LIMITS 0
25 50 75 100 125 150 175 200 225 250 MINIMUM REACTOR VESSEL METAL TEMPERATURE
( 0F)
Figure 3.4.9-3 (Page 1 of 1)
Critical Operations Curve (Valid to 54 EFPY)
I Quad Cities I and 2 3.4.9 -8 Amendment No. 228, 223