SLs 2.0 2.0 SAFETY LIMITS (SLs) 2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10% rated core flow:
THERMAL POWER shall be s 25% RTP.
2.1.1.2 With the reactor steam dome pressure Ž 785 psig and core flow Ž 10% rated core flow:
For Unit 2 be Ž 1.11, MCPR shall For Unit 3 be Ž 1.12, MCPR shall two recirculation loop operation, MCPR shall or for single recirculation loop operation, be Ž 1.12.
two recirculation loop operation, MCPR shall or for single recirculation loop operation, be R t e 1.14.
I 2.1.1.3 Reactor vessel water level shall be greater than the top of. active irradiated fuel.
2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be : 1345 psig.
2.2 SL Violations With any SL violation, the following actions shall be completed within
.2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s:
2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.
Dresden 2 and 3 2.0-1 Amendment No. 199/213