Letter Sequence Approval |
---|
|
|
MONTHYEARML17291A1512017-10-18018 October 2017 NRR E-mail Capture - Accepted for Review - TVA Fleet License Amendment Request to Revise Sequoyah Emergency Plan Staffing Augmentation Times Project stage: Acceptance Review ML18065A4322018-02-0909 February 2018 Email - Sequoyah Nuclear Plant, Units 1 and 2 - Request for Additional Information Related to LAR for Emergency Response Plan Staff Augmentation Times (EPIC: L-2017-LLA-0310) Project stage: RAI ML18159A4612018-08-0606 August 2018 Issuance of Amendments Regarding Request to Change Emergency Plan Project stage: Approval ML18250A2042018-10-0303 October 2018 Correction to Amendment Nos. 342 and 335, Removed Nonapplicable Statement in Safety Evaluation to Change Emergency Plan Project stage: Approval 2018-10-03
[Table View] |
|
---|
Category:Letter
MONTHYEARCNL-24-021, Application to Revise Technical Specification Limiting Condition of Operation 3.5.2, ECCS – Operating, Note 1 to Include Residual Heat Removal Pump Flow Paths (SQN-TS-23-04 and WBN-TS-23-020)2024-11-12012 November 2024 Application to Revise Technical Specification Limiting Condition of Operation 3.5.2, ECCS – Operating, Note 1 to Include Residual Heat Removal Pump Flow Paths (SQN-TS-23-04 and WBN-TS-23-020) ML24312A1552024-11-0606 November 2024 Cycle 27 Core Operating Limits Report, Revision 1 IR 05000327/20240032024-11-0606 November 2024 Integrated Inspection Report 05000327/2024003 and 05000328/2024003 CNL-24-014, License Amendment Request to Revise the Sequoyah Nuclear Plant, Units 1 and 2 and Watts Bar Nuclear Plant, Units 1 and 2 Technical Specifications to Use Online Monitoring Methodology (SQN-TS-24-02 and WBN-TS-23-22)2024-11-0404 November 2024 License Amendment Request to Revise the Sequoyah Nuclear Plant, Units 1 and 2 and Watts Bar Nuclear Plant, Units 1 and 2 Technical Specifications to Use Online Monitoring Methodology (SQN-TS-24-02 and WBN-TS-23-22) ML24304A8492024-10-31031 October 2024 December 2024 Requalification Inspection Notification Letter IR 05000327/20250102024-10-29029 October 2024 Notification of Sequoyah, Units 1 and 2 - Comprehensive Engineering Team Inspection - U.S. Nuclear Regulatory Commission Inspection Report 05000327/2025010 and 05000328/2025010 ML24298A1172024-10-24024 October 2024 Cycle 26, 180-Day Steam Generator Tube Inspection Report CNL-24-074, Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revisions2024-10-23023 October 2024 Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revisions 05000327/LER-2024-001, Reactor Trip Due to a Turbine Trip2024-10-17017 October 2024 Reactor Trip Due to a Turbine Trip ML24282B0412024-10-15015 October 2024 Request for Withholding Information from Public Disclosure for Sequoyah Nuclear Plant, Units 1 and 2 and Watts Bar Nuclear Plant, Units 1 and 2 ML24260A1682024-10-0404 October 2024 Regulatory Audit Summary Related to Request to Add and Revise Notes Related to Technical Specification Table 3.3.2-1, Function 5 ML24284A1072024-09-26026 September 2024 Affidavit for Request for Withholding Information from Public Disclosure for Sequoyah Nuclear Plant, Units 1 and 2, and Watts Bar Nuclear Plant, Units 1 and 2 05000328/LER-2024-001, Reactor Trip Due to an Electrical Trouble Turbine Trip2024-09-25025 September 2024 Reactor Trip Due to an Electrical Trouble Turbine Trip CNL-24-047, Decommitment of Flood Mode Mitigation Improvement Systems2024-09-24024 September 2024 Decommitment of Flood Mode Mitigation Improvement Systems CNL-24-060, Supplement to Request for Approval of the Tennessee Valley Authority Nuclear Quality Assurance Program Description2024-09-24024 September 2024 Supplement to Request for Approval of the Tennessee Valley Authority Nuclear Quality Assurance Program Description ML24262A0602024-09-23023 September 2024 Summary of August 19, 2024, Meeting with Tennessee Valley Authority Regarding a Proposed Supplement to the Tennessee Valley Authority Nuclear Quality Assurance Plan ML24267A0402024-09-19019 September 2024 Cycle 27 Core Operating Limits Report Revision 0 ML24185A1742024-09-18018 September 2024 Cover Letter - Issuance of Exemption Related to Non-Destructive Examination Compliance Regarding Sequoyah Nuclear Plant Independent Spent Fuel Storage Installation CNL-24-065, Tennessee Valley Authority – Central Emergency Control Center Emergency Plan Implementing Procedure Revisions2024-09-18018 September 2024 Tennessee Valley Authority – Central Emergency Control Center Emergency Plan Implementing Procedure Revisions ML24253A0152024-09-0808 September 2024 Emergency Plan Implementing Procedure Revisions ML24247A2212024-08-29029 August 2024 Notification of Deviation from Pressurized Water Reactor Owners Group (PWROG) Letter OG-21-160, NEI 03-08 Needed Guidance: PWR Lower Radial Support Clevis Insert X-750 Bolt Inspection Requirements, September 1, 2021 ML24247A1802024-08-28028 August 2024 Application to Revise the Fuel Handling Accident Analysis, to Delete Technical Specification 3.9.4, Containment Penetrations, and to Modify Technical Specification 3.3.6, Containment Ventilation Isolation Instrumentation for Sequoyah Nuclea IR 05000327/20240052024-08-26026 August 2024 Updated Inspection Plan for Sequoyah Nuclear Plant, Units 1 and 2 - Report 05000327/2024005 and 05000328/2024005 ML24239A3972024-08-23023 August 2024 Rssc Wire & Cable LLC Dba Marmon - Part 21 Final Notification - 57243-EN 57243 CNL-24-061, Supplement to Application to Revise Function 5 of Technical Specification Table 3.3.2-1, ‘Engineered Safety Feature Actuation System Instrumentation,’ for the Sequoyah and Watts Bar (SQN-TS-23-02 and WBN-TS-23-08),2024-08-19019 August 2024 Supplement to Application to Revise Function 5 of Technical Specification Table 3.3.2-1, ‘Engineered Safety Feature Actuation System Instrumentation,’ for the Sequoyah and Watts Bar (SQN-TS-23-02 and WBN-TS-23-08), IR 05000327/20240022024-07-31031 July 2024 Integrated Inspection Report 05000327/2024002 and 05000328/2024002 ML24211A0542024-07-29029 July 2024 Operator License Examination Report ML24211A0572024-07-29029 July 2024 Submittal of Emergency Plan Implementing Procedure Revision ML24211A0412024-07-26026 July 2024 Unit 1 Cycle 26 Refueling Outage - 90-Day Inservice Inspection Summary Report ML24199A0012024-07-22022 July 2024 Clarification and Correction to Exemption from Requirement of 10 CFR 37.11(c)(2) ML24172A1342024-07-15015 July 2024 Exemptions from 10 CFR 37.11(C)(2) (EPID L-2023-LLE-0024) - Letter ML24191A4652024-07-0909 July 2024 Response to NRC Regulatory Issue Summary 2024-01, Preparation and Scheduling of Operator Licensing Examinations ML24177A0282024-06-25025 June 2024 Emergency Plan Implementing Procedure Revisions ML24176A0222024-06-24024 June 2024 Retraction of Interim Report of a Deviation or Failure to Comply – Transducer Model 8005N ML24089A1152024-06-21021 June 2024 Transmittal Letter, Environmental Assessments and Findings of No Significant Impact Related to Exemption Requests from 10 CFR 37.11(c)(2) ML24145A0852024-05-30030 May 2024 1B-B Diesel Generator Failure - Final Significance Determination Letter ML24145A1052024-05-29029 May 2024 301 Exam Approval Letter ML24134A1762024-05-13013 May 2024 Submittal of 2023 Annual Radiological Environmental Operating Report CNL-24-040, Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revisions2024-05-0808 May 2024 Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revisions ML24128A0352024-05-0707 May 2024 Providing Supplemental Information to Apparent Violation ML24120A0582024-04-26026 April 2024 10 CFR 50.46 Annual Report for Sequoyah Nuclear Plant Units 1 and 2 ML24116A2612024-04-25025 April 2024 Interim Report of a Deviation or Failure to Comply - Transducer Model 8005N ML24114A0482024-04-23023 April 2024 Annual Radioactive Effluent Release Report for 2023 Monitoring Period CNL-24-037, Clinch River, Sequoyah, Units 1 and 2, Watts Bar, Unit 1 and 2, Nuclear Quality Assurance Plan, TVA-NQA-PLN89-A, Revision 422024-04-22022 April 2024 Clinch River, Sequoyah, Units 1 and 2, Watts Bar, Unit 1 and 2, Nuclear Quality Assurance Plan, TVA-NQA-PLN89-A, Revision 42 ML24144A2322024-04-20020 April 2024 Tennessee Multi-Sector Permit (Tmsp), 2024 Annual Discharge Monitoring Report for Outfalls SW-3, SW-3, and SW-9 ML24144A2362024-04-20020 April 2024 Discharge Monitoring Report (Dmr), March 2024 ML24102A1212024-04-18018 April 2024 Summary of Conference Call with Tennessee Valley Authority Regarding Sequoyah Nuclear Plant, Unit 1 Spring 2024 Steam Generator Tube Inspections ML24089A0882024-04-18018 April 2024 – Exemption from Select Requirements of 10 CFR Part 73; Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting CNL-24-033, Central Emergency Control Center Emergency Plan Implementing Procedure Revisions2024-04-17017 April 2024 Central Emergency Control Center Emergency Plan Implementing Procedure Revisions 2024-09-08
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Joseph W. Shea Vice President, Nuclear Regulatory Affairs and Support Services Tennessee Valley Authority 1101 Market Street, LP 4A Chattanooga, TN 37402-2801 October 3, 2018
SUBJECT:
SEQUOYAH NUCLEAR PLANT, UNITS 1 AND 2 -CORRECTION TO NONAPPLICABLE STATEMENT IN SAFETY EVALUATION TO CHANGE EMERGENCY PLAN (EPID L-2017-LLA-0310)
Dear Mr. Shea:
On August 6, 2018, the Nuclear Regulatory Commission (NRC) issued Amendment Nos. 342 and 335 to Renewed Facility Operating License Nos. DPR-77 and DPR-79 for Sequoyah Nuclear Plant, Units 1 and 2, respectively.
These amendments are in response to your application dated September 29, 2017, as supplemented by letter dated March 14, 2018. These amendments revised the Sequoyah Nuclear Plant's Emergency Plan to change the emergency response organization (ERO) staffing composition and to increase the staff augmentation times from 30 minutes to 60 minutes and from 60 minutes to 90 minutes for certain ERO positions from the time of declaration of an Alert or higher emergency classification level. After issuance of the amendments, the NRC staff was informed that the Safety Evaluation Section 3.2.5, Major Functional Area: Plant System Engineering, Repair and Corrective Actions," under Technical Support (4 1 h paragraph) contains a nonapplicable statement.
Please replace the incorrect page 9 with the corrected Safety Evaluation page 9 enclosed with this letter. This did not change our conclusions and bases.
J. Shea We apologize for any inconvenience this may cause you. If you have any questions regarding this matter, please contact me at (301) 415-8480.
Docket Nos. 50-327 and 50-328,
Enclosure:
Corrected Safety Evaluation Page cc: Listserv Sincerely, Andrew Hon, Project Manager Plant Licensing Branch 11-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation ENCLOSURE 3.2.5 Major Functional Area: Plant System Engineering, Repair, and Corrective Actions This Major Functional Area includes the following tasks: Technical Support: The guidance in NUREG-0654, Table B-1, identifies one on-shift Shift Technical Advisor (STA), one core/thermal hydraulics engineering expert to be available in 30 minutes, and one electrical and one mechanical engineering expert to be available in 60 minutes. The current SON Emergency Plan identifies an on-shift ST A with a Core/Thermal Engineer, a Mechanical Engineer, and an Electrical Engineer augmenting within 60 minutes of the declaration of an Alert or higher ECL. TVA proposes to transfer the Core/Thermal Engineer task to a Core Damage Assessor at the CECC, who will respond in 60 minutes to the CECC after the declaration of an Alert or higher ECL. TVA states that the Core Damage Assessor is specifically identified and is qualified to perform the core/thermal-hydraulic function for all TVA sites. The Mechanical Engineer and the Electrical Engineer will continue to respond within 60 minutes of the declaration of an Alert or higher ECL. TV A will continue to provide augmented staffing within 60 minutes of the declaration of an Alert or higher ECL to perform the Core/Thermal Engineer function, and to provide an Electrical Engineer and a Mechanical Engineer.
The NRC staff finds that changing the location of the 60-minute augmentation Core/Thermal Engineer function from the TSC to the CECC Core Damage Assessor to be acceptable as there is no loss of function or impact on the timing for providing the Core/Thermal Engineer task. Therefore, the proposed SON Emergency Plan continues to meet the standards of 10 CFR 50.47(b) and the requirements of Appendix E to 10 CFR Part 50. Repair and Corrective Actions: The guidance in NUREG-0654, Table B-1, specifies the major task of "Repair and Corrective Actions" to be fulfilled on-shift by a total of two personnel and "[m]ay be provided by shift personnel assigned other functions." One person would perform the function of a mechanic and one person would perform the function of an electrician.
One electrician and one instrument and control (l&C) technician would respond within 30 minutes to augment the ERO. One mechanic, one Rad Waste operator, and one additional electrician would respond within 60 minutes to augment the ERO.
- The current SON Emergency Plan has one l&C technician, one mechanic, and two electricians, who report to the OSC upon entry into the emergency plan with one additional mechanic and one additional electrician responding within 60 minutes of the declaration of an Alert or higher ECL. The proposed SON Emergency Plan would eliminate the on-shift repair team staffing, while maintaining one mechanic and one electrician augmenting within 60 minutes and an l&C technician responding within 90 minutes of the declaration of an Alert or higher ECL.
J. Shea
SUBJECT:
SEQUOYAH NUCLEAR PLANT, UNITS 1 AND 2-CORRECTION TO NONAPPLICABLE STATEMENT IN SAFETY EVALUATION TO CHANGE EMERGENCY PLAN (EPID L-2017-LLA-0310)
DATED OCTOBER 3, 2018 DISTRIBUTION:
PUBLIC PM Reading File RidsNrrDorl Resource RidsDorlLpl2-2 Resource RidsNrrPMSequoyah Resource RidsNrrLABClayton Resource RidsRgn2MailCenter Resource RidsACRS_MailCTR Resource RidsNsirDpr Resource RHoffman, NSIR MNorris, NSIR ADAMS Accession No.: ML 18250A204 OFFICE NRR/DORULPL2-2/PM NRR/DORULPL2-2/LA NAME AHon BClayton DATE 09/28/18 09/26/18 OFFICE NRR/DORULPL2-2/BC NRR/DORULPL2-2/PM NAME UShoop AHon DATE 10/03/18 10/03/18 OFFICIAL RECORD COPY *b email NSIR/DPR/RLB/BC*
JAnderson 08/31/18