05000454/FIN-2011009-03
From kanterella
Revision as of 14:04, 30 September 2017 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Finding | |
---|---|
Title | |
Description | The inspectors identified a finding of very low safety significance and an associated NCV of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the licensees failure to correctly translate applicable design basis (calculations) into specifications. Specifically, the licensee failed to take into account fuel oil consumption at an increased frequency of 61.2 Hz in their EDG loading calculations which resulted in non-conservative Technical Specifications. The licensee entered this finding into their corrective action program as IR 01226844 and implemented actions to evaluate incorporation of the EDG frequency administrative limits into applicable site operating procedures to ensure an adequate supply of fuel was available. The inspectors determined that this finding was more than minor because the finding was associated with the Mitigating Systems cornerstone attribute of design control and affected the cornerstone objective of ensuring the capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). Specifically, the licensee failed to account for the increased fuel oil consumption resulting from operation at a higher EDG frequency variation of 61.2 Hz as allowed by TS 3.8.1 and room temperature of up to 120F in their EDG loading calculations. Therefore, the licensee did not ensure that the minimum fuel oil level in the storage tanks, as required per TS 3.8.3, was adequate to support the EDGs 7-day mission time. This finding had a cross-cutting aspect in the area of Problem Identification and Resolution Corrective Action Program because the licensee did not thoroughly evaluate the EDG fuel oil consumption when considering EDG frequency variation. Specifically, the licensee failed to translate applicable design bases into specifications, which resulted in non-conservative TS. |
Site: | Byron |
---|---|
Report | IR 05000454/2011009 Section 4OA2 |
Date counted | Jun 30, 2011 (2011Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | Z Falevits R Daley R Winter L Jones I Hafeez |
CCA | P.2, Evaluation |
INPO aspect | PI.2 |
' | |
Finding - Byron - IR 05000454/2011009 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Byron) @ 2011Q2
Self-Identified List (Byron)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||