Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Report dateSiteEvent description
05000000/LER-1950-237, Updated LER 50-237/01L:on 760406,unacceptable Ultrasonic Indication Found on Isolation Condenser safe-end.Caused by Cracks in safe-ends.Cracked safe-end Removed & Sent to Bmcl for Metallographic AnalysisDresden
Surry
05000000
05000280/LER-1975-006, Supplemental LER 75-06/010:on 750215,module S/N D401 Failed Due to Capacitor C-37 Being Open Circuit.Capacitors ReplacedSurry
05000280/LER-1975-008, Supplementary LER 75-08/01L on 750427.Previously Described Event Caused by Apparent Inadequate Implementation of Administrative Controls During Const & Preoperation. Administrative Control of Electrical Wire Changes IncreasedSurry
05000280/LER-1975-011, Suppl to LER 75-11/01T:on 750416,pinhole Leak Developed in Recirculation Line on Charging Pump 2-CH-P-1C Causing Ventilation Vent Sampler RMS-VG-109 to Alarm.Leak Found & IsolatedSurry
05000280/LER-1975-015, Updated LER 75-15/01T:on 750803,leaking Fitting on Overhead Gas Compressor B Resulted in Unplanned Release of Radioctive Matl from Site.Caused by Loose Fitting.Leaking Fitting RepairedSurry
05000280/LER-1975-016, Updated LER 75-16/010:on 750822 & 23,channel II Protection Drifted in Nonconservative Direction.Caused by Moisture Accumulation Between Senson Insulation & Copper Lead Wire. All RTDs Replaced W/Improved VersionsSurry
05000280/LER-1976-002, Updated LER 76-02/01T:on 760313,determined Worst Break LOCA Core Thermal Transient Analysis Inaccurate Since Effects of Steam Generator Tube Plugging on LOCA Not ConsideredSurry
05000280/LER-1976-002, Updated LER 76-02/01T:on 760313,determined Worst Break LOCA Core Thermal Transient Analysis Inaccurate Since Effects of Steam Generator Tube Plugging on LOCA Not Considered. W/760525 LtrSurry
05000280/LER-1977-012, RO S1-77-01 Re Failures of Hydraulic Shock Supports (Snubbers).Extent of Failures Reported in LER 77-12.All Snubbers Operable on 771207 StartupSurry
05000280/LER-1979-045, Updated LER 79-045/01X-1:on 791228,air Would Not Flow Through Filters If Consequence Limiting Safeguards hi-hi Signal Removed from Control Circuit of Safeguards Area Exhaust Ventilation Dampers.Caused by Design DeficiencySurry
05000280/LER-1980-009, Forwards LERs 82-049/03L-0,82-080/03L-0 & Updated LER 80-009/01X-1Surry
05000280/LER-1980-019, Forwards Updated LER 80-019/03X-1 & LERs 82-058/03L-0 & 82-099/03L-0Surry
05000280/LER-1980-059, Updated LER 80-059/01X-1:on 801016,util Informed of Potential for Loss of Auxiliary Feedwater Flow Following Steamline Rupture.Caused by Original Design Allowing Pump Runout & Subsequent Tripping of Sys Pump MotorsSurry
05000280/LER-1981-047, Updated LER 81-047/03X-1:on 810910,following Reactor Trip & While Returning to Power,Specific Activity of RCS Indicated Dose Equivalent I-131 Level Greater than Tech Spec Limit. Caused by Fuel Element Defect in Reactor CoreSurry
05000280/LER-1981-081, /03L-0:on 820121,during Research for LER 81-081/03L-0,found That Original Vacuum Pumps Were Replaced W/Pumps That Failed to Meet Required Seismic Qualifications. Study of Present Pumps Completed.Assistance Request IssuedSurry
05000280/LER-1982-007, Forwards LER 82-007/03L-0Surry
05000280/LER-1982-018, Forwards LER 82-018/03L-0Surry
05000280/LER-1982-024Surry
05000280/LER-1982-025Surry
05000280/LER-1982-026Surry
05000280/LER-1982-027Surry
05000280/LER-1982-028Surry
05000280/LER-1982-029Surry
05000280/LER-1982-032Surry
05000280/LER-1982-035Surry
05000280/LER-1982-036Surry
05000280/LER-1982-049, Updated LER 82-049/03X-1:on 820419,at 100% Power,Charging Pump Svc Water Pump 1-SW-P 10B Found W/Zero Discharge Pressure.Caused by Loss of Suction to Pumps Due to Increased Use of Svc Water by Chillers.Pump Operation RestoredSurry
05000280/LER-1982-055Surry
05000280/LER-1982-057Surry
05000280/LER-1982-058Surry
05000280/LER-1982-059Surry
05000280/LER-1982-060Surry
05000280/LER-1982-061Surry
05000280/LER-1982-062Surry
05000280/LER-1982-063Surry
05000280/LER-1982-065Surry
05000280/LER-1982-066Surry
05000280/LER-1982-067, Forwards LER 82-067/03L-0Surry
05000280/LER-1982-068Surry
05000280/LER-1982-070Surry
05000280/LER-1982-071Surry
05000280/LER-1982-072, Forwards LER 82-072/03L-0 & 82-068/03L-0Surry
05000280/LER-1982-073Surry
05000280/LER-1982-074Surry
05000280/LER-1982-083, Forwards LER 82-083/03L-0 & Updated LER 82-084/01X-1Surry
05000280/LER-1982-084, Updated LER 82-084/01X-1:on 820808,venting of a Charging Pump Resulted in Max Instantaneous Release Rate Being Exceeded.Caused by Failure to Change Radiation Monitor Setpoint Alarms to Reflect New Vent Sys Flow RatesSurry
05000280/LER-1982-086, Forwards LER 82-086/03L-0Surry
05000280/LER-1982-091, Forwards LER 82-091/03L-0Surry
05000280/LER-1982-121, Forwards LER 82-121/03L-0Surry
05000280/LER-1982-126, Updated LER 82-126/03X-1:on 821223,rod Position Indication for Control Rod F-4 Indicated Erratically & Fluctuated Greater than 12 Steps.Cause Unknown.Erroneous Signal Suspected of Being Inside Containment.Testing UnderwaySurry