Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML060680596 | 28 February 2005 | Hydrothermal Modeling of Browns Ferry with Units 1, 2, and 3 at Extended Power Uprate | Ultimate heat sink |
ML060680599 | 31 March 2001 | Bear Creek Reservoirs Land Management Plan | |
ML060720253 | 23 May 1975 | May 23, 1975 - Final Summary Report Unit 2 Startup | Power change Flow Induced Vibration |
ML060720272 | 9 May 1977 | May 9, 1977 - Final Summary Report Unit 3 Startup | Shutdown Margin Grab sample Stroke time Fuel cladding Power change Flow Induced Vibration |
ML060720273 | 30 November 1992 | a Guide for Environmental and Best Management Practices for Tennessee Valley Authority Transmission Construction and Maintenance Activities | |
ML060720293 | 28 February 2005 | Hydrothermal Modeling of Browns Ferry Nuclear Plant with Units 1, 2, and 3 at Extended Power Uprate | Ultimate heat sink |
ML060720354 | 31 March 2006 | GE-NE-0000-0049-6652-01NP, Rev 0, General Electric Boiling Water Reactor Steam Dryer Scale Model Test Based Fluctuating Load Definition Methodology, March 2006 Benchmark Report | Finite Element Analysis Flow Induced Vibration |
ML060720430 | 1 March 2006 | March 1, 2006 Public Meeting Slides for Proposed Generic Letter Post-Fire Safe-Shutdown Circuit Analysis Spurious Actuations. | Hot Short Safe Shutdown Significance Determination Process Thermoset Exemption Request Fire Protection Program Backfit |
ML060880413 | 21 March 2006 | EPU Containment Overpressure Credit Risk Assessment, Rev. 1 | High winds Mission time Internal Flooding Probabilistic Risk Assessment Coatings Large early release frequency |
ML060880464 | 21 March 2006 | BFN EPU Containment Overpressure (COP) Credit Risk Assessment, Rev. 1 | High winds Mission time Internal Flooding Probabilistic Risk Assessment Coatings Large early release frequency |
ML061070632 | 30 April 2006 | Units 1, 2, & 3 - GENE-0000-0052-3661-01-NP, Test Report #1, Browns Ferry Nuclear Plant; Unit 1, Scale Model Test. | |
ML061300441 | 31 May 2006 | C.D.I. Report 06-11, Rev 1, Hydrodynamic Loads on Browns Ferry, Unit 1 Steam Dryer to 200 Hz. | |
ML061300443 | 31 May 2006 | GE-NE-0000-0053-7413-R0-NP, Browns Ferry, Units 1, 2 & 3 Steam Dryer Stress, Dynamic and Fatigue Analyses for EPU Conditions. | Finite Element Analysis Earthquake Flow Induced Vibration |
ML061450395 | 15 May 2006 | 0043-8325-SRLR, Revision 1, Supplemental Reload Licensing Report for Brown Ferry 1, Reload 6 Cycle 7, Cover Through Page 122 | Shutdown Margin Anticipated operational occurrence MELLLA |
ML061450397 | 15 May 2006 | 0043-8325-SRLR, Revision 1, Supplemental Reload Licensing Report for Brown Ferry 1, Reload 6 Cycle 7, Pages 123 Through End | Safety Limit Minimum Critical Power Ratio Anticipated operational occurrence Feedwater Controller Failure MELLLA |
ML061670151 | 12 June 2006 | Extended Power Uprate (EPU) - Reload Analysis Report | Shutdown Margin Safety Limit Minimum Critical Power Ratio Anticipated operational occurrence Abnormal operational transient Feedwater Controller Failure MELLLA Fuel cladding |
ML062090482 | 10 July 2006 | BFN EPU Containment Overpressure (COP) Credit Risk Assessment, Rev. 2 | High winds Mission time Internal Flooding Probabilistic Risk Assessment Large early release frequency |
ML062130343 | 31 July 2006 | C.D.I. Report No. 06-11, Revision 2, Hydrodynamic Loads on Browns Ferry Nuclear Unit 1 Steam Dryer to 200 Hz. | |
ML062200277 | 26 July 2006 | Technical Specifications (TS) Changes TS-431 & TS-418 - Extended Power Uprate (EPU) - Response to Round 7 Requests for Additional Information | VT-2 Finite Element Analysis Flow Induced Vibration |
ML062210102 | 27 June 2006 | Technical Specifications (TS) Change TS-431 & TS-418 Extended Power Uprate (EPU) - Replacement Cooling Tower | License Renewal Power Uprate |
ML062400477 | 30 June 2006 | GENE-0000-0055-2994-R1-NP, Addendum to Browns Ferry Nuclear Plant Units 1, 2, and 3 Steam Dryer Stress, Dynamic, and Fatigue Analyses for EPU Conditions. | |
ML062510385 | 31 May 2006 | Enclosure 3, Browns Ferry, Units 1, 2 & 3 - CDI Report No. 05-28P, Rev 1, Bounding Methodology to Predict Full Scale Steam Dryer Loads from In-Plant Measurements. | |
ML062790232 | 31 August 2006 | Engineering Report, GE-NE-0000-0053-7413-R4-NP, Browns Ferry, Units 1, 2 and 3 - Steam Dryer Stress, Dynamic and Fatigue Analyses for EPU Conditions. | Finite Element Analysis Earthquake Flow Induced Vibration |
ML062920156 | 13 September 2006 | Rev 1 to Technical Specification, NPSH Transient Study RHR and Core Spray Pumps, E12.5.1296 | |
ML063100442 | 1 November 2006 | Supplemental Information - Changes to Instrumentation Surveillance Test Intervals and Allowed Out-of-Service Times | Reactor Vessel Water Level Half scram Stroke time Scram Discharge Volume |
ML063180243 | 2 November 2006 | Gnf Additional Information Regarding the Requested Changes to Technical Specification SLMCPR, Cycle 7 | Anticipated operational occurrence Minimum Critical Power Ratio |
ML063530037 | 14 December 2006 | Core Operating Limits Report for Cycle 7 Operation | Shutdown Margin |
ML071030397 | 13 April 2007 | Status of Unit 1 Restart Issues, Revision 12 | Safe Shutdown High winds Reactor Vessel Water Level Probabilistic Risk Assessment Coatings Operator Manual Action Emergency Lighting License Renewal Hardened vent Fire Protection Program Power Uprate |
ML071150369 | 23 April 2007 | Units 1, 2, & 3 - Submittal of Unit 1 Periodic Inspection Program for License Renewal Procedure in Fulfillment of License Renewal Commitment | |
ML071650168 | 1 April 1999 | NEI Report: RCP Lube Oil Collection System Current Trend Abstract, April 1999 (Revision 1) | Safe Shutdown Safe Shutdown Earthquake Hydrostatic Emergency Lighting Exemption Request Earthquake Fire Protection Program Fire Watch |
ML071720186 | 31 March 2006 | Enclosure 2 Technical Evaluation Report on the Seismic Portion of Browns Ferry Nuclear Plant Unit 1 Individual Plant Examination for External Events | Safe Shutdown High winds Ultimate heat sink Safe Shutdown Earthquake Internal Flooding Probabilistic Risk Assessment Operating Basis Earthquake Emergency Lighting Aging Management Design basis earthquake Earthquake Weak link |
ML071720197 | 31 October 2006 | Enclosure 3 Technical Evaluation Report on the High Winds, Floods, Transportation and Other (Hfo) External Events Portion of Browns Ferry Nuclear Plant Unit 1 Individual Plant Examination for External Events | Safe Shutdown High winds Tornado Generated Missile |
ML072130375 | 31 July 2007 | CDI Report No. 07-05NP, Revision 0, Finite Element Model for Stress Assessment of Browns Ferry, Unit 1, Steam Dryer to 250 Hz | Finite Element Analysis Liquid penetrant |
ML072130382 | 31 July 2007 | CDI Report No. 07-06NP, Revision 0, Finite Element Model for Stress Assessment of Browns Ferry, Unit 2 & 2 Steam Dryer to 250 Hz | Finite Element Analysis Liquid penetrant |
ML072130386 | 31 July 2007 | CDI Report No. 07-09NP, Revision 0, Methodology to Predict Full Scale Steam Dryer Loads from In-Plant Measurements, with Inclusion of a Low Frequency Hydrodynamic Contribution | |
ML072130401 | 31 July 2007 | CDI Report No. 07-10NP, Revision 0, Acoustic and Low Frequency Hydrodynamic Loads at CLTP Power Level on Browns Ferry, Unit 2, Steam Dryer to 250 Hz | |
ML072130415 | 31 July 2007 | CDI Report No. 07-11NP, Revision 0, Dynamics of BWR Steam Dryer Components | |
ML072130429 | 31 July 2007 | C.D.I. Technical Memorandum No. 07-26NP, Revision 0, Comparison of Browns Ferry Unit 1 & Unit 2 Main Steam Line Strain Gage / Pressure Readings | |
ML072360262 | 31 August 2007 | 07-30NP, Limit Curve Analysis with ACM Rev. 4 for Power Ascension at Browns Ferry, Unit 1, Revision 0 | Finite Element Analysis |
ML072360263 | 31 August 2007 | 07-31NP, Limit Curve Analysis with ACM Rev. 4 for Power Ascension at Browns Ferry, Unit 2 and 3, Revision 0 | Finite Element Analysis |
ML072750045 | 24 September 2007 | ANP-2631, Revision 0, Browns Ferry Unit 3 Cycle 14 Reload Analysis Report. | Shutdown Margin Safety Limit Minimum Critical Power Ratio Anticipated operational occurrence Abnormal operational transient Feedwater Controller Failure MELLLA Fuel cladding |
ML081010453 | 30 April 2008 | CDI Report No. 08-07NP, Rev. 1, Stress Assessment of Browns Ferry Nuclear Unit 2 Steam Dryer. | Finite Element Analysis Liquid penetrant |
ML081010454 | 31 March 2008 | CDI Report No. 08-05NP, Acoustic and Low Frequency Hydrodynamic Loads at CLTP Power Level on Browns Ferry Nuclear Unit 2 Steam Dryer to 250 Hz with Noise Removed. | Finite Element Analysis |
ML081700294 | 12 June 2008 | Technical Specifications Changes TS-431 and TS-418 - Extended Power Uprate - Response to ACRS Conclusions and Recommendations Regarding Containment Overpressure Credit | Safe Shutdown Ultimate heat sink Probabilistic Risk Assessment Significance Determination Process Earthquake Fire Protection Program |
ML081750081 | 16 June 2008 | Encl. 6, Calculation Package 0006982.301, Extended Power Uprate Main Steam Line Strain Gage Vibration Monitoring, and Encl. 7, Response to Round 15 Group 4 and Round 17 Request for Additional Information | Time of Discovery |
ML081750083 | 30 June 2008 | Enclosure 8, CDI Report No. 08-15NP, Stress Assessment of Browns Ferry Nuclear Unit 1 Steam Dryer and Tie-Bar Modifications, Revision 1 | Finite Element Analysis Liquid penetrant |
ML081750084 | 30 June 2008 | Enclosure 9, CDI Report No. 08-04NP, Acoustic and Low Frequency Hydrodynamic Loads at CLTP Power Level on Browns Ferry Nuclear Unit 1 Steam Dryer to 250 Hz, Revision 1 | |
ML081760256 | 30 June 2008 | CDI Report No. 08-16NP, Stress Assessments of Brown Ferry Nuclear Unit 2 Steam Dryer with Tie Bar and Hood Modifications, Revision 0 | Finite Element Analysis Liquid penetrant |
ML081760260 | 30 June 2008 | CDI Report No. 08-05NP, Acoustic and Low Frequency Hydrodynamic Loads at CLTP Power Level on Browns Ferry Nuclear Unit 2 Steam Dryer to 250 Hz with Noise Removed, Revision 2 | |
ML082190013 | 7 August 2008 | Monthly Operating Reports Second Quarter 2008 | Reserve Station Service Transformer Power change |