05000409/LER-1979-019, Forwards LER 79-019/01T-026 December 1979Forwards LER 79-019/01T-0
05000409/LER-1982-007, Forwards LER 82-007/03L-0.Detailed Event Analysis Submitted14 June 1982Forwards LER 82-007/03L-0.Detailed Event Analysis Submitted
05000409/LER-1982-008, Forwards LER 82-008/03L-0.Detailed Event Analysis Submitted16 June 1982Forwards LER 82-008/03L-0.Detailed Event Analysis Submitted
05000409/LER-1982-012, Forwards LER 82-012/03L-0.Detailed Event Analysis Submitted18 June 1982Forwards LER 82-012/03L-0.Detailed Event Analysis Submitted
05000409/LER-1982-013, Forwards LER 82-013/03L-0.Detailed Event Analysis Submitted1 July 1982Forwards LER 82-013/03L-0.Detailed Event Analysis Submitted
05000409/LER-1982-014, Forwards LER 82-014/01T-0.Detailed Event Analysis Submitted9 June 1982Forwards LER 82-014/01T-0.Detailed Event Analysis Submitted
05000409/LER-1982-015, Forwards LER 82-015/01T-0.Detailed Event Analysis Submitted17 June 1982Forwards LER 82-015/01T-0.Detailed Event Analysis Submitted
05000409/LER-1982-016, Forwards LER 82-016/03L-0.Detailed Event Analysis Encl29 July 1982Forwards LER 82-016/03L-0.Detailed Event Analysis Encl
05000409/LER-1982-020, Updated LER 82-020/03X-1:on 821119-20,on Three Occasions Vacuum Pump Which Maintains Isokinetic Flow Rate to Stack Activity Monitors Tripped.Caused by Pump & Motor Overheating.Motor Thermal Overload Fuses Upgraded21 April 1983Updated LER 82-020/03X-1:on 821119-20,on Three Occasions Vacuum Pump Which Maintains Isokinetic Flow Rate to Stack Activity Monitors Tripped.Caused by Pump & Motor Overheating.Motor Thermal Overload Fuses Upgraded
05000409/LER-1983-001, Forwards LER 83-001/03L-0 & Updated LER 82-020/03X-1. Detailed Event Analysis Encl21 April 1983Forwards LER 83-001/03L-0 & Updated LER 82-020/03X-1. Detailed Event Analysis Encl
CAC:00008327 June 2018
CAC:L2483314 March 2016
CAC:L530961 June 2016
CAC:L531026 April 2016
CAC:L531341 December 2016
CAC:L5313527 June 2016
CAC:L5313627 June 2016
ENS 42908Unusual Event - High Airborne Particulate in the Reactor Building
ENS 52575Offsite Notification to State of Wisconsin Due to Inadvertent Release of Contaminated Water
ENS 53254Press Release Planned
EPID:L-2017-DTP-0008Lacrossesolutions License Termination Plan Request for Additional Information
EPID:L-2017-FPR-0037Package: Request for Additional Information Regarding Dairyland Power Cooperative'S Decommissioning Funding Plan Update for La Crosse Boiling Water Reactor Independent Spent Fuel Storage Installation
EPID:L-2019-LIT-0000License Transfer Order Third Extension Approval
EPID:L-2020-LLO-0004EA-19-077
EPID:L-2021-LLA-0063
EPID:L-2021-LLO-0003EA-22-024
IA-84-478, Forwards Press Release 84-69 Re NRC Reduction of Fine for 1983 Violation.Pressure Sensing Device Capped.Fine Reduced Due to Short Duration of Violation,Small Size of Reactor & Comparable Enforcement Actions1 June 1984Forwards Press Release 84-69 Re NRC Reduction of Fine for 1983 Violation.Pressure Sensing Device Capped.Fine Reduced Due to Short Duration of Violation,Small Size of Reactor & Comparable Enforcement Actions
IA-85-513, Responds to FOIA Request for 24 Specified Documents & Related Info Re Transportation of Spent Nuclear Reactor Fuel.Forwards App a Documents.App a & B Documents Available in PDR6 August 1985Responds to FOIA Request for 24 Specified Documents & Related Info Re Transportation of Spent Nuclear Reactor Fuel.Forwards App a Documents.App a & B Documents Available in PDR
IA-86-827, Final Response to FOIA Request for Documents.App a Documents Consisting of La Crosse & Big Rock Point Semiannual Effluent Repts & App B Documents Consisting of Encl Turkey Point & St Lucie SALP Repts Available in Pdr.W/O Stated Encls16 December 1986Final Response to FOIA Request for Documents.App a Documents Consisting of La Crosse & Big Rock Point Semiannual Effluent Repts & App B Documents Consisting of Encl Turkey Point & St Lucie SALP Repts Available in Pdr.W/O Stated EnclsSafe Shutdown
Fitness for Duty
High Radiation Area
Fire Barrier
Temporary Modification
Locked High Radiation Area
Missed surveillance
Systematic Assessment of Licensee Performance
Operability Determination
Exemption Request
Control of Heavy Loads
Fuel cladding
Fire Protection Program
Hourly Fire Watch
Substantial potential for overexposure
Overexposure
IA-89-409, Final Response to FOIA Request.App a & B Records Available in PDR & Encl.Portions of App B Record Withheld (Ref FOIA Exemption 6)26 September 1989Final Response to FOIA Request.App a & B Records Available in PDR & Encl.Portions of App B Record Withheld (Ref FOIA Exemption 6)
IR 05000409/197801023 October 1978IE Inspec Rept 50-409/78-10 on 780920-22 During Which No Items of Noncompliance Were Noted.Major Area Inspected: Environ Protec Prog
IR 05000409/19780111 November 1978IE Inspec Rept 50-409/78-11 on 781004-06 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Incl:Maint,Spent Fuel Packaging & Shipping,Actions Re IE Bulletins,Open Inspec Items,Lers
IR 05000409/197801316 November 1978IE Inspec Rept 50-409/78-13 on 781023-24 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Incl:Insvc Inspec Qa/Qc Prog,Implementing Procedures,Data Review & Eval
IR 05000409/198102326 July 1982IE Insp Rept 50-409/81-23 on 811222-820331.Noncompliance Noted:Failure to Follow Procedures That Resulted in Unintentional Cooldown of 1B Forced Circulation Loop to Below Limits & to Follow Procedure During 820316 Event
IR 05000409/198102422 June 1982IE Mgt Meeting Rept 50-409/81-24 on 811009.No Noncompliance Noted.Major Areas Discussed:Systematic Assessment of Licensee Performance,Jul 1980-June 1981.Overall Regulatory Performance Adequate.Mgt Attention Needed in Listed Areas
IR 05000409/198200829 June 1982IE Insp Rept 50-409/82-08 on 820524-28.No Noncompliance Noted.Major Areas Inspected:Operational Radiation Protection & Refueling Activities Including Effluent Control Instrumentation & Testing of Air Cleaning Sys
IR 05000409/198400910 March 1986Safety Evaluation Supporting Util 850208 Proposed Installation of Two Check Valves in Series in Sample Line to Improve Capability to Isolate Containment Atmosphere from Environ,Per Insp Rept 50-409/84-09
IR 05000409/198500131 July 1985Errata & Corrected Page 10 to SALP 5 Rept 50-409/85-01 for Jul 1983 - Dec 1984
IR 05000409/198500815 July 1985Insp Rept 50-409/85-08 on 850624-26.No Noncompliance or Deviation Noted.Major Areas Inspected:Emergency Preparedness Exercise,Involving Observations of Key Functions & Locations During ExerciseHigh winds
IR 05000409/198500910 July 1985Insp Rept 50-409/85-09 on 850416-17.Violation Noted:Failure to Properly Align Alternate Core Spray Sys Prior to Performing Hydrostatic Test on Reactor Pressure VesselHydrostatic
IR 05000409/19850118 July 1985Insp Rept 50-409/85-11 on 850610-14.No Violation or Deviation Noted.Major Areas Inspected:Surveillance of Core Thermal Power Distribution Limits,Core Thermal Power Evaluation & Control Rod Scram Time TestingShutdown Margin
Power change
IR 05000409/198501318 September 1985Insp Rept 50-409/85-13 on 850708-11,0820 & 30.Violation Noted:Failure to Hydrostatically Test Fire ExtinguishersSafe Shutdown
Reactor Vessel Water Level
Fire Barrier
Safe Shutdown Earthquake
Hydrostatic
Emergency Lighting
Exemption Request
Fire Protection Program
IR 05000409/198501417 October 1985Insp Rept 50-409/85-14 on 850916-1004.No Violation or Deviation Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings,Maint,Qa/Qc Administration,Tests & Experiments,Receipts,Storage,Handling & Procurement
IR 05000409/19850152 October 1985Insp Rept 50-409/85-15 on 850916-20.Violation Noted:Failure to Maintain Whole Body Dose Records Per NRC-5 Instructions
IR 05000409/198501623 October 1985Physical Security Insp Rept 50-409/85-16 on 850930-1004. Violations Noted:Failure to Maintain Clear Isolation Zone & Search Hardware & Some Alarm Zones Failed to Perform as Required.Details Withheld (Ref 10CFR73.21)
IR 05000409/19850175 November 1985Insp Rept 50-409/85-17 on 851023-1101.No Violation or Deviation Noted.Major Areas Inspected:Followup of IE Bulletin 84-03,inservice Testing Program Implementation & Inservice Testing of Pumps,Valves & Test InstrumentsStroke time
Earthquake
Power Operated Valves
IR 05000409/198501919 November 1985Insp Rept 50-409/85-19 on 851023-25.No Violations or Deviations Noted.Major Areas Inspected:Followup on Alert Declared by Licensee & Actions Re Confirmatory Action Ltr on Flux Level Alarm Failing to Scram on 851023Failure to Scram
IR 05000409/19850204 December 1985Insp Rept 50-409/85-20 on 851112-15.No Violation or Deviation Noted.Major Areas Inspected:Gaseous & Liquid Radioactive Program,Including Effluent Release Records,Repts of Effluents & Effluent Control InstrumentationGrab sample
Post Accident Monitoring
Fuel cladding
IR 05000409/198502116 January 1986Insp Rept 50-409/85-21 on 851216-19.No Noncompliance or Deviation Noted.Major Areas Inspected:Confirmatory Measurements Program,Including Sampling,Lab Qc,Followup on Open Items & Regulatory Improvement Items
IR 05000409/198502221 February 1986Insp Rept 50-409/85-22 on 851217-860214.No Violations Noted. Major Areas Inspected:Licensee Actions on Previous Insp Findings,Operational Safety Verification,Monthly Maint Observation,Ler Followups & TMI Action ItemsSystematic Assessment of Licensee Performance
Weak link