-3-(3) Pursuant to the Act and 10 CFR Parts 30, 40, and 70, to receive, possess, and use at any time any byproduct, source, and special nuclear material as sealed neutron sources for reactor startup, sealed sources for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required;(4) Pursuant to the Act and 10 CFR Parts 30, 40, and 70, to receive, possess, and use in amounts as required any byproduct, source, or special nuclear material without restriction to chemical or physical form for sample analysis or equipment and instrument calibration or associated with radioactive apparatus or components; (5) Pursuant to the Act and 10 CFR Parts 30 and 70, to possess but not separate, such byproduct and special nuclear materials as may be produced by the operation of the facility.C. This renewed operating license shall be deemed to contain and is subject to the conditions specified in the following Commission regulations in 10 CFR Chapter 1: Part 20, Section 30.34 of Part 30, Section 40.41 of Part 40, Sections 50.54 and 50.59 of Part 50, and Section 70.32 of Part 70; is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below: (1) Maximum Power Level The licensee is authorized to operate the facility at steady state reactor core power levels not in excess of 3293 megawatts thermal.(2) Technical Specification s The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 259, are hereby incorporated in the renewed operating license. The licensee shall operate the facility in accordance with the Technical Specifications.

For Surveillance Requirements (SRs) that are new in Amendment 234 to Facility Operating License DPR-33, the first performance is due at the end of the first surveillance interval that begins at implementation of the Amendment 234. For SRs that existed prior to Amendment 234, including SRs with modified acceptance criteria and SRs whose frequency of performance is being extended, the first performance is due at the end of the first surveillance interval that begins on the date the surveillance was last performed prior to implementation of Amendment 234.Renewed License No. DPR-33 Amendment No. 259 RPS Instrumentation 3.3.1.1 Table 3.3.1.1-1 (page 3 of 3)Reactor Protection System Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED FUNCTION OTHER CHANNELS FROM .SURVEILLANCE ALLOWABLE SPECIFIED PER TRIP REQUIRED REQUIREMENTS VALUE CONDITIONS SYSTEM ACTION D.1 7. Scram Discharge Volume Water Level -High (continued)

b. Float Switch 1,2 2 G SR 3.3.1.1.8 46 gallons SR 3.3.1.1.13 SR 3.3.1.1.14 5 (a) 2. H SR 3.3.1.1.8
5 46 gallons SR 3.3.1.1.13 SR 3.3.1.1.14
8. Turbine Stop Valve -Closure 2!30% RTP 4 E SR 3.3.1.1.8
5 10% dosed SR 3.3.1.1.13 SR 3.3.1.1.14 SR 3.3.1.1.15
9. Turbine Control Valve Fast 30% RTP 2 E SR 3.3.1.1.8 550 psig Closure, Trip Oil Pressure -SR 3.3.1.1.13 Low(d) SR 3.3.1.1.14 SR 3.3.1.1.15
10. Reactor Mode Switch -1.2 1 G SR 3.3.1.1.12 NA Shutdown Position SR 3.3.1.1.14 5 (a) 1 H SR 3.3.1.1.12 NA SR 3.3.1.1.14
11. Manual Scram 1,2 1 G SR 3.3.1.1.8 NA SR 3.3.1.1.14 5 (a) 1 H SR 3.3.1.1.8 NA SR 3.3.1.1.14
12. RPS Channel Test Switches 1,2 2 G SR 3.3.1.1.4 NA 5 (a) 2 H SR 3.3.1.1.4 NA (a) With any control rod withdrawn from a core cell containing one or more fuel assemblies.(d) During Instrument calibrations, If the As Found channel setpoint Is conservative with respect to the Allowable Value but outside its acceptable As Found band as defined by its associated Surveillance Requirement procedure, then there shall be an initial determination to ensure confidence that the channel can perform as required before returning the channel to service in accordance with the Surveillance.

If the As Found instrument channel setpoint is not conservative with respect to the Allowable Value, the channel shall be declared inoperable.

Prior to returning a channel to service, the instrument channel setpoint shall be calibrated to a value that is within the acceptable As Left tolerance of the setpoint; otherwise, the channel shall be declared inoperable.

The nominal Trip Setpoint shall be specified on design output documentation which is incorporated by reference in the Updated Final Safety Analysis Report. The methodology used to determine the nominal Trip Setpoint, the predefined As Found Tolerance, and the As Left Tolerance bend, and a listing of the setpoint design output documentation shall be specified in Chapter 7 of the Updated Final Safety Analysis Report.BFN-UNIT I 3.3-8 BFN-NITI 33-8Amendment No. 234r-,2,W-259