Safety Evaluation Report Related to the License Renewal of Three Mile Island, Unit 1
ML091320042
Person / Time
Site: Three Mile Island Constellation icon.png
Issue date: 06/30/2009
From: Holian B E
Division of License Renewal
To: Gallagher M P
Exelon Generation Co
Robinson, J NRR/DLR/RPB1 415-2878
Shared Package
ML091320041 List:
References
TAC MD7701
Download: ML091320042 (6)


Text

June 30, 2009 Mr. Michael P. Gallagher Vice President License Renewal Projects Exelon Generation Company, LLC 200 Exelon Way, KSA/2-E Kennett Square, PA 19348

SUBJECT:

SAFETY EVALUATION REPORT RELATED TO THE LICENSE RENEWAL OF THREE MILE ISLAND NUCLEAR STATION, UNIT 1

Dear Mr. Gallagher:

By letter dated January 8, 2008, AmerGen Energy Company, LLC (AmerGen or the applicant), (now Exelon Generation Company, LLC) (Exelon or the applicant), submitted, for the U.S.

Nuclear Regulatory Commission's (NRC or staff) review, an application to renew the Three Mile Island Nuclear Station, Unit 1, (TMI-1) operating license for up to an additional 20 years. The license renewal application (LRA) was submitted pursuant to Title 10 of the Code of Federal Regulations Part 54, "Requirements for Renewal of Operating Licenses for Nuclear Power Plants." The staff determined that the LRA was complete and acceptable for docketing on March 10, 2008.

Since that time, the staff has reviewed the TMI-1 LRA, issued requests for additional information (RAIs), reviewed the applicant's responses to the staff's RAIs, developed a safety evaluation report (SER) with open items, and reviewed the applicant's comments on the SER with open items. The SER with open items was discussed at an Advisory Committee on Reactor Safeguards (ACRS) subcommittee meeting on April 1, 2009. On the basis of this review, the staff has developed the enclosed SER to document its findings associated with the safety review of the LRA and supporting documentation for TMI-1.

This SER is scheduled to be discussed at the ACRS full committee meeting on September 10, 2009.

M. Gallagher If you have any questions regarding this matter, please contact the license renewal project manager, Jay Robinson, at 301-415-2878 or by e-mail at Jay.Robinson@nrc.gov. Sincerely,

/RA/ Brian Holian, Director Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-289

Enclosure:

As stated

cc w/encl: See next page

(PKG.) ML091320041, (LTR.) ML091320042, (ENCLOSURE) ML091660470 OFFICE PM:DLR:RPB1 LA:DLR BC:DLR:RPB1BC:DLR:RER1 BC:DLR:RER2 NAME JRobinson SFigueroa DPelton JDozier RAuluck DATE 05/14/09 05/14/09 05/22/09 05/29/09 06/02/09 OFFICE BC:DE:EMCB BC:DE:EEEB BC:DSS:SRXBBC:DSS:SCVB BC:DSS:SBPB NAME MKhana RMathew GCranston RDennig GPurciarello DATE 05/22/09 05/15/09 05/29/09 05/19/09 06/02/09 OFFICE BC:DCI:CPNB BC:DCI:CSGBBC:DCI:CVIB BC:DRA:AFPB OGC (NLO) NAME TChan MGavrilas MMitchell AKlein BMizuno DATE 05/19/09 05/20/09 05/15/09 05/19/09 06/15/09 OFFICE D:DE D:DSS D:DCI D:DRA D:DLR NAME ABoland WRuland (SBahadur for)MEvans (JLubinski for) MCunningham BHolian DATE 06/11/09 06/10/09 06/10/09 06/03/09 06/30/09 Letter to Michael P. Gallagher from Brian E. Holian, dated June 30, 2009

SUBJECT:

SAFETY EVALUATION REPORT WITH OPEN ITEMS RELATED TO THE LICENSE RENEWAL OF THREE MILE ISLAND NUCLEAR STATION, UNIT 1 DISTRIBUTION

HARD COPY: DLR RF E-MAIL: PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RdsNrrDlrRer1 Resource RidsNrrDlrRer2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsNrrDciCvib Resource RidsNrrDciCpnb Resource RidsNrrDciCsgb Resource RidsNrrDraAfpb Resource RidsNrrDeEmcb Resource RidsNrrDeEeeb Resource RidsNrrDssSrxb Resource RidsNrrDssSbpb Resource RidsNrrDssScvb Resource RidsOgcMailCenter

SLopas MModes, RI DKern JBrand RConte RBellamy PBamford Three Mile Island Nuclear Station, Unit 1 cc: Site Vice President - Three Mile Island Nuclear Station, Unit 1 Exelon Generation Company, LLC P.O. Box 480 Middletown, PA 17057 Senior Vice President - Mid-Atlantic Operations Exelon Generation Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Regional Administrator Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406

Chairman Board of County Commissioners of Dauphin County Dauphin County Courthouse Harrisburg, PA 17120

Chairman Board of Supervisors of Londonderry Township R.D. #1, Geyers Church Road Middletown, PA 17057 Senior Resident Inspector (TMI-1) U.S. Nuclear Regulatory Commission P.O. Box 219 Middletown, PA 17057

Director - Licensing and Regulatory Affairs Exelon Generation Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Director Bureau of Radiation Protection Pennsylvania Department of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469

Plant Manager - Three Mile Island Nuclear Station, Unit 1 Exelon Generation Company, LLC P. O. Box 480 Middletown, PA 17057

Manager, Regulatory Assurance Three Mile Island Nuclear Station, Unit 1 Exelon Generation Company, LLC P.O. Box 480 Middletown, PA 17057 Ronald Bellamy, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Michael A. Schoppman Framatome ANP Suite 705 1911 North Ft. Myer Drive Rosslyn, VA 22209 Dr. Judith Johnsrud National Energy Committee Sierra Club 433 Orlando Avenue State College, PA 16803

Three Mile Island Nuclear Station, Unit 1 cc: Eric Epstein TMI Alert 4100 Hillsdale Road Harrisburg, PA 17112 Correspondence Control Desk Exelon Generation Company, LLC 200 Exelon Way, KSA 1-N-1 Kennett Square, PA 19348 Manager Licensing Exelon Generation Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348

Christopher M. Crane President and Chief Operating Officer, Exelon Corporation Chief Operating Officer Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Mr. Charles G. Pardee Senior Vice President, Exelon Generation Company LLC, President & Chief Nuclear Officer, Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Mr. Michael J. Pacilio Senior Vice President, Exelon Generation Company, LLC Chief Operation Officer, Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 Senior Vice President, Operations Support Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Associate General Counsel Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Frederick W. Polaski Manager License Renewal Exelon Nuclear 200 Exelon Way Kennett Square, PA 19348 Albert A. Fulvio License Renewal Senior Project Manager Exelon Nuclear 200 Exelon Way Kennett Square, PA 19348