| event date = 10/01/2016 05:12 CDT
| event date = 10/01/2016 05:12 CDT
| last update date = 10/01/2016
| last update date = 10/01/2016
| title = Automatic Reactor Trip Due To Inadvertent Closure Of Main Steam Isolation Valve
| title = Automatic Reactor Trip Due to Inadvertent Closure of Main Steam Isolation Valve
| event text = At 0512 [CDT] on October 1, 2016, Farley Nuclear Plant Unit 1 automatically tripped from 99 percent reactor power due to the inadvertent closure of a main steam isolation valve (MSIV). The closure of the MSIV caused a turbine trip resulting in an automatic reactor trip. Concurrent with the reactor trip, a safety injection (SI) occurred. The plant is stable in Mode 3 (Hot Standby) and auxiliary feedwater (AFW) autostarted as expected. The cause of MSIV closure and SI actuation is under investigation.
| event text = At 0512 [CDT] on October 1, 2016, Farley Nuclear Plant Unit 1 automatically tripped from 99 percent reactor power due to the inadvertent closure of a main steam isolation valve (MSIV). The closure of the MSIV caused a turbine trip resulting in an automatic reactor trip. Concurrent with the reactor trip, a safety injection (SI) occurred. The plant is stable in Mode 3 (Hot Standby) and auxiliary feedwater (AFW) autostarted as expected. The cause of MSIV closure and SI actuation is under investigation.
Cooldown will continue to Mode 5 (Cold Shutdown) as planned for entry into a scheduled refueling outage. Restart is not planned until the completion of the refueling outage. Unit 2 was not affected.
Cooldown will continue to Mode 5 (Cold Shutdown) as planned for entry into a scheduled refueling outage. Restart is not planned until the completion of the refueling outage. Unit 2 was not affected.

Latest revision as of 21:44, 1 March 2018

ENS 52274 +/-
Where
Farley Southern Nuclear icon.png
Alabama (NRC Region 2)
Reporting
10 CFR 50.72(b)(2)(iv)(A), System Actuation - ECCS Discharge

10 CFR 50.72(b)(2)(iv)(B), RPS Actuation

10 CFR 50.72(b)(3)(iv)(A), System Actuation
Time - Person (Reporting Time:+-0.5 h-0.0208 days <br />-0.00298 weeks <br />-6.849e-4 months <br />)
Opened: Douglas Hobson
09:42 Oct 1, 2016
NRC Officer: Dong Park
Last Updated: Oct 1, 2016
52274 - NRC Website