{{#Wiki_filter:PARAMETER Dissolved Oxygen Chloride Fluoride TABLE 3.4-2 REACTOR COOLANT SYSTEM CHEMISTRY LIMITS STEADY-STATE LIMIT< 0.10 ppm< 0.15 ppm< 0.15 ppm TRANSIENT LIMIT< 1.00 ppm< 1.50 ppm< 1.50 ppm Limit not applicable with Tavg less than or equal to 250'F.I SHEARON HARRIS -UNIT 1 3/4 4-27 Amendment No.
{{#Wiki_filter:TABLE 3.4-2 REACTOR COOLANT SYSTEM CHEMISTRY LIMITS STEADY-STATE     TRANSIENT PARAMETER                              LIMIT            LIMIT Dissolved Oxygen                    < 0.10 ppm       < 1.00 ppm Chloride                            < 0.15 ppm       < 1.50 ppm Fluoride                            < 0.15 ppm       < 1.50 ppm Limit not applicable with Tavg less than or equal to 250'F.               I SHEARON HARRIS - UNIT 1             3/4 4-27                 Amendment No.
TABLE 4.4-3 REACTOR COOLANT SYSTEM CHEMISTRY LIMITS SURVEILLANCE REQUIREMENTS PARAMETER Dissolved Oxygen SAMPLE AND ANALYSIS FREQUENCY At least once per 72 hours Chloride At least once per 72 hours At least once per 72 hours Fluoride Not required with TI, less than or equal to 250 0 F SHEARON HARRIS -UNIT 1 3/4 4-28 Amendment No.}}
 
TABLE 4.4-3 REACTOR COOLANT SYSTEM CHEMISTRY LIMITS SURVEILLANCE REQUIREMENTS SAMPLE AND PARAMETER                                      ANALYSIS FREQUENCY Dissolved Oxygen                                At least once per 72 hours Chloride                                       At least once per 72 hours Fluoride                                        At least once per 72 hours Not required with TI, less than or equal to 2500 F SHEARON HARRIS - UNIT 1             3/4 4-28                 Amendment No.}}

Latest revision as of 22:17, 23 November 2019

Tech Spec Pages for Amendment 120 Regarding Temperature Limit for Dissolved Oxygen in Reactor Coolant System
ML060680312
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 03/08/2006
From:
Plant Licensing Branch III-2
To:
Patel Chandu, NRR/DORL 301-415-3025
Shared Package
ML060580174 List:
References
TAC MC7399
Download: ML060680312 (2)


Text

TABLE 3.4-2 REACTOR COOLANT SYSTEM CHEMISTRY LIMITS STEADY-STATE TRANSIENT PARAMETER LIMIT LIMIT Dissolved Oxygen < 0.10 ppm < 1.00 ppm Chloride < 0.15 ppm < 1.50 ppm Fluoride < 0.15 ppm < 1.50 ppm Limit not applicable with Tavg less than or equal to 250'F. I SHEARON HARRIS - UNIT 1 3/4 4-27 Amendment No.

TABLE 4.4-3 REACTOR COOLANT SYSTEM CHEMISTRY LIMITS SURVEILLANCE REQUIREMENTS SAMPLE AND PARAMETER ANALYSIS FREQUENCY Dissolved Oxygen At least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Chloride At least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Fluoride At least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Not required with TI, less than or equal to 2500 F SHEARON HARRIS - UNIT 1 3/4 4-28 Amendment No.