ML18348A214: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:* * *
{{#Wiki_filter:consumers
* consumers Power *Company ;-;-:--, , ..........
* 7--,7
r 7--,7 L;ic...,p0**:.;kii.:.::zL General Offices: 212 West Michigan Avenue, .Jackson, Michigan-49201
* Area Code 517 788-0550 October 4, l977 Mr James G Keppler Office of Inspection and Inforcement Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60l37 DOCKET 50-255, LICENSE DPR-20 PALISADES PLANT .,.. CORRECTED ER.,-77-034 AND ER-77-041 Licensee Event Report 77-034 reported an apparent high level in safety injection tank SI-82C. In the "cause description" portion of the report, we stated that testing would be performed.to determine the path of apparent leakage. In August, we determined that the cause of the low level indication was not in leakage, but instead was faulty indication.
Inasmuch as the leakage testing initially*
proposed is no longer applicable, an updated LER is attached to clarify the* record. Licensee Event Report 77-041 did not present a clear sequence of events leading to the low fuel inventory.
A corrected LER is attached to identify the proper cause description.
David P Hoffman ( S.igned) David P Hoffman Assistant Nuclear Licensing Administrator CC: ASchwencer, USNRC ---------------
.. -* u:iarE -PREVIOUS REPOR'l' DATE 08-01-* . *LICENSEE EVENT
* REPORT CORRECTED Palisades eoNTROL BLOCK: I I I I I I I (PLEASE PRINT ALL REQUIRED INFORMATION]
NAME LICENSEE I MI I I Pl A I L I 1 I 7 8 9 14 REPORT TYPE. 1 6 LICENSE NUMBER I o I o 1-1 o I o I o I o I ol-1 o I o I 15 25 REPORT SOURCE DOCKl;T NUMBER LICENSE TYPE 14111111111 26 30 EVENT OATE EVENT TYPE I o I 3 I 31 32 REPORT DATE @TI]coN'T l *I *I 7 8 57 58 lLJ LrJ lolslol-lol2l sl sl I ol 11 ol s1 11 ] lol912l917171 59 so 68 69 74 75 80 EVENT DESCRIPTION
@:lfil I T-82C safety injectiqn tank level was found to be 1% above Technical Specifications 7 8 9 10131 I limits. 7 8 9 The tank was drained to bring indicated level back within Technical lol4l I Specifications limits. (ER-77-034) 7 8 9 I 80 I 80 I 80 7 8 9...._ ____________________________________________________________________________________
__,80 lolsl 7 8 9 SYSTEM CODE @El Isl Fl CAUSE CODE COMPONENT CODE l!J I Al c I cl d MI u I 7 8 s 10 11 12 17 CAUSE DESCRIPTION PRIME COMPONENT SUPPLIER w 43 COMPONENT MANUFACTURER I z I 9 I 9 I 9 I 44 47 80 VIOLATION L1LI 48 I investigation revealed that the cause of the event was faulty indication.
I 7 8 9 80 I The indication has been restored to normal and no further action is contemplated.
I 7 8 9 r. I (Reference LER 77-40) 8 9 FACILITY EE] 7 8 rn STATUS LI_] 9 FORM OF ACTIVITY RELEASED w % PO'NER OTHER STATUS I 1 I 0 I 0 I I N /A I 10 12 13 44 CONTENT OF RELEASE AMOUNT OF ACTIVITY w I N/A. l METHOD OF DISCOVERY 45 46 N/A 7 8 9 10 11 44 45 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION ITEi 10101.01 l.!J I N/A 7 8 9 11 12 13 PERSONNEL INJURIES NUMBER DESCRIPTION tlO I 80 DISCOVERY DESCRIPTION llLA 80 LOCATION OF RELEASE 80 80 rn 1o1 o 1 01. N/A. 7 8 9 11 PROBABLE CONSEQUENCES lill] I N /A 7 8 9 80 LOSS OR DAMAGE TO FACILITY TYPE DESCRIPTION
[]]]_ U_J 7 8 9 10 tlO PUBLICITY ITIZJ I N/A 7 8 9 BO A,..., ADDITIONAL FACTORS 7 8 9 80 GE 7 8 9 80 
-.. .LICENSEE EVENT REPORT
* CORRECTED Palisades
*
*
* caw AOL BLOCK: I 1 I I I I [PLEASE PRINT ALL REQUIRED INFORMATION]
                                                                                        ;-;-:--, .~"""'. ,.......... r Power                                                            L;ic...,p0**:.;kii.:.::zL
6 LICENSE NUMBER lo lo 1-lol ol ol ol ol-lo lo I 15 25 REPORT REPORT TYPE SOURCE OOCKJ;T NUMBER LICENSE TYPE 14111111!11 26 30 EVENT DATE EVENT TYPE Io I 1 I 31 32 REPORT OATE @IT]coN'T r
                      *Company General Offices: 212 West Michigan Avenue, .Jackson, Michigan- 49201
* I
* Area Code 517 788-0550 October 4, l977 Mr James G Keppler Office of Inspection and Inforcement Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60l37 DOCKET 50-255, LICENSE DPR-20 ~
* I 7 8 57 58 L!J 1015 lo I-lo 1215151 I o I 8 I 21 3 I 11 11 lol2lol2l1l1I 59 60 . 61 68 69 74 75 80 EVENT DESCRIPTION  
PALISADES PLANT .,.. CORRECTED ER.,-77-034 AND ER-77-041 Licensee Event Report 77-034 reported an apparent high level in safety injection
@lfil I At 1600 on 8/23/77, during routine start-up operations, the level in the diesel oil 7 8 9 @El I storage tank, T-10, had decreased to 53 percent. 80 This is the level that provides the I 7 8 9 . loj41 I minimum required volume of 16 ,000 gallons as specified in Technical Specifications 7 8 9 @Jfil I 3. 7 .1. i for heatup above 325°F. Plant cooldown commenced immediately.
* tank SI-82C. In the "cause description" portion of the report, we stated that testing would be performed.to determine the path of apparent leakage.
At 1800 oil 7 8 9 . '
In August, we determined that the cause of the low level indication was not in leakage, but instead was faulty indication. Inasmuch as the leakage testing initially* proposed is no longer applicable, an updated LER is attached to clarify the* record.
lfil§] I was delivered and heatup resumed. Problem is not repetit*ive. (ER-77-041) 7 8 9 SYSTEM CAUSE CODE COOE COMPONENT CODE @El I El E I LEJ I x Ix I x I xi xi zj 7 8 9 10 11 12 17 CAUSE DESCRIPTION PRIME COMPONENT SUPPLIER w 43 COMPONENT MANUFACTURER I z I 9 I 9 I 9 I 44 47 VIOLATION w 48 80 I 80 I 80 I 80 ._I _F_u_e_l_h_a_d_b_ee_n_o_r_d_e_r_e_d_o_n_th_e_m_o_r_n_i_n..:;;g'--o_f_8.:.../2_2...;/_7.:...7.:...'=--b_u_t_t_h_e_su  
Licensee Event Report 77-041 did not present a clear sequence of events leading to the low fuel inventory. A corrected LER is attached to identify the proper cause description.
.... p=-p._l_i_*
David P Hoffman ( S.igned)
e_r_f_a_i_l_e_d_t_o_d_e_l_i_* 7 8 9 80 lo191 I that day. Delivery was further delayed on 8/23/77 because of difficulty in obtaining I 7 8 9 80 .. I a delivery vehicle. Correspondence to the supplier stressing the need for (Contd) I 8 9 80 FACILITY METHOD OF STATUS % POWER OTHER STATUS DISCOVERY DISCOVERY DESCRIPTION EEi W . lo I 0 I 0 I I Routine Start-Up I LJJ I N/A. 7 8 9 10 12 13 44 45 46 80 FORM OF ACTIVITY CONTENT RELEASED OF RELEASE AMOUNT OF ACTIVITY w ._I _...N""""/
David P Hoffman Assistant Nuclear Licensing Administrator CC:    ASchwencer, USNRC
A..._, ______ __...,. 9 10 11 44 rn 7 8 LOCATION OF RELEASE 45 N/A 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION lolol
*
________________________________________________
 
;......J 7 8 9 11 12 13 80 PERSONNEL INJURIES NUMBER DESCRIPTION rn 1 o , a 1 a 1 .__N __ /_A ___________________________
            -
.....,...,..,. 7 8 9 11 12 . 80 PROBABLE CONSEQUENCES lIJfil None 7 8 9 80 LOSS OR DAMAGE TO FACILITY TYPE DESCRIPTION IIfil 7 8 9 10 PUBLICITY
* u:iarE - PREVIOUS REPOR'l' DATE 08-01-*                                  CORRECTED
[ill} N/A 7 8 9 ADDITIONAL FACTORS I Cause Description (Contd) -urgency in making deliveries is expected to forestall 7 8 9 (Tifil I future delivery problems. 7 8 9 80 80 80 I 80}}
                                                      . *LICENSEE EVENT
* REPORT Palisades eoNTROL BLOCK:        I I I I I I I                                          (PLEASE PRINT ALL REQUIRED INFORMATION]
1                        6
~ I MI LICENSEE                                                                              LICENSE                EVENT NAME                                  LICENSE NUMBER                                  TYPE                  TYPE I I Pl A I L    I1    I I o I o 1-1 oI oI oI oI ol-1 o I o I 14111111111 I o I 3 I 7    8 9                            14      15                                              25    26                    30    31    32 REPORT    REPORT TYPE. SOURCE            DOCKl;T NUMBER                          EVENT OATE                      REPORT DATE
    @TI]coN'T      l *I *I          lLJ      LrJ      lolslol-lol2l sl sl I ol 11 ol s1 11 ] lol912l917171 7    8          57        58      59        so      ~                                68    69                        74    75                  80 EVENT DESCRIPTION
  @:lfil I T-82C safety injectiqn tank level was found to be 1% above Technical Specifications                                                          I 7    8 9                                                                                                                                            80 10131 I        limits.          The tank was drained to bring indicated level back within Technical                                                    I 7    8 9                                                                                                                                            80 lol4l I        Specifications limits.                  (ER-77-034)                                                                                    I 7    8 9                                                                                                                                            80 7  8 9...._______________________________________________________________________________________,80
  ~
lolsl 7    8 9                                                                PRIME                                                                        80 SYSTEM        CAUSE                                      COMPONENT            COMPONENT CODE        CODE              COMPONENT CODE            SUPPLIER            MANUFACTURER          VIOLATION 7
  @El Isl Fl 8  s 10 l!J 11 I Al cI cl d MI u I 12                        17 w43 I z I 9 I 9 I 9I 44                47 L1LI 48 CAUSE DESCRIPTION
  ~      I      Subse~uent investigation revealed that the cause of the event was faulty indication.                                                    I 7    8  9                                                                                                                                          80
  ~      I      The indication has been restored to normal and no further action is contemplated.                                                      I r.
7    8  9                                                                                                                                          tlO I      (Reference LER 77-40)                                                                                                                  I 8 9                                                                                                                                            80 FACILITY                                                        METHOD OF STATUS              % PO'NER              OTHER STATUS          DISCOVERY                      DISCOVERY DESCRIPTION EE]            LI_]            I I 0 I 0 I I N /A 1                                          I ~                llLA 7    8        9              10            12 13                        44      45      46                                                      80 FORM OF ACTIVITY        CONTENT 7
rn  8 RELEASED w
9 w
OF RELEASE 10    11 I  N/A.
AMOUNT OF ACTIVITY 44 l        45 N/A LOCATION OF RELEASE 80 PERSONNEL EXPOSURES NUMBER          TYPE      DESCRIPTION ITEi 10101.01 l.!J I                        N/A 7    8 9                11    12    13                                                                                                          80 PERSONNEL INJURIES rn 1o1 o 7    8 9 NUMBER 1  01.
11 DESCRIPTION N/A.
1~2------~--------~-------------------------------------------------"'-------8~0 PROBABLE CONSEQUENCES lill] I        N /A 7    8 9                                                                                                                                            80 LOSS OR DAMAGE TO FACILITY TYPE        DESCRIPTION
[]]]_ U_J            .,,._~N'"'-=A__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,~
7    8 9          10                                                                                                                              tlO PUBLICITY ITIZJ I        N/A 7    8 9                                                                                                                                            BO A,...,    ADDITIONAL FACTORS
~IN/A 7    8 9                                                                                                                                            80 GE8 9 7                                                                                                                                                  80
 
-
CORRECTED
                                                              .LICENSEE EVENT REPORT
* Palisades
                        *
* caw AOL       BLOCK:       I I I I                   I                                       [PLEASE PRINT ALL REQUIRED INFORMATION]
1                        6 LICENSE                    EVENT LICENSE NUMBER                                                 TYPE                      TYPE lo lo 1-lol ol ol ol ol-lo lo I 14111111!11 Io I 1 I 15                                                         25     26                          30      31    32 REPORT     REPORT TYPE     SOURCE                 OOCKJ;T NUMBER                                     EVENT DATE                             REPORT OATE 7
    @IT]coN'T 8
r* I *58I L!J 57              59
                                                  ~
60 1015 lo I-lo 1215151 I oI 8 I 21 3 I 11 11 lol2lol2l1l1I
                                                            . 61                                   68           69                               74     75                     80 EVENT DESCRIPTION
    @lfil I       At 1600 on 8/23/77, during routine start-up operations, the level in the diesel oil 7     8 9                                                                                                                                                                       80
    @El I         storage tank, T-10, had decreased to 53 percent.                                                 This is the level that provides the                               I 7     8 9             .                                                                                                                                                         80 loj41 I minimum             required volume of 16 ,000 gallons as specified in Technical Specifications                                                                           I 7     8 9                                                                                                                                                                       80
    @Jfil I 3. 7 .1. i         for heatup above 325°F.                     Plant cooldown commenced immediately.                                             At 1800 oil           I 7   8 9             .           '                                                                                                                                           80 lfil§] I     was delivered and heatup resumed.                             Problem is not repetit*ive.                                     (ER-77-041)                           I 7     8 9                                                                     PRIME                                                                                              80 SYSTEM     CAUSE                                             COMPONENT                    COMPONENT CODE       COOE               COMPONENT CODE                 SUPPLIER                  MANUFACTURER                      VIOLATION 7
    @El I El E I LEJ 8 9      10          11 I x Ix I xI xi xi zj 12                             17 w 43             44 Iz I9 I9 I9 I 47 w 48 CAUSE DESCRIPTION
    ~        ._I                                                                                                                 ....p=-p._l_i_*e_r_f_a_i_l_e_d_t_o_d_e_l_i_*v_e_r_~I
_F_u_e_l_h_a_d_b_ee_n_o_r_d_e_r_e_d_o_n_th_e_m_o_r_n_i_n..:;;g'--o_f_8.:.../2_2...;/_7.:...7.:...'=--b_u_t_t_h_e_su 7     8 9                                                                                                                                                                       80 lo191 I       that day.         Delivery was further delayed on 8/23/77 because of difficulty in obtaining                                                                       I 7     8 9                                                                                                                                                                       80 I a delivery             vehicle.               Correspondence to the supplier stressing the need for (Contd)                                                             I
  . .8 9 FACILITY                                                                       METHOD OF 80 STATUS           % POWER                       OTHER STATUS           DISCOVERY                                       DISCOVERY DESCRIPTION 7
EEi8            W.
9 lo I 0 I 0 I I Routine 10              12 13 Start-Up 44 I     LJJ 45            46 I     N/A.
80 FORM OF ACTIVITY     CONTENT rn w RELEASED     OF RELEASE                 AMOUNT OF ACTIVITY                                                           LOCATION OF RELEASE
                                  ~        ._I_...N""""/
A..._,_ _ _ _ _ ___...,.                           N/A 7    8          9             10     11                                       44           45                                                                               80 PERSONNEL EXPOSURES NUMBER         TYPE       DESCRIPTION
    ~lo            lolol         ~        i-.;.;N~A;.:_________________________________________________;......J 7     8 9               11     12     13                                                                                                                                       80 PERSONNEL INJURIES rn      1o NUMBER
                    , a 1 a1 DESCRIPTION
                                  .__N__/_A_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.....,...,..,.
7     8 9               11   12                                                                                                                                               . 80 PROBABLE CONSEQUENCES lIJfil8 9 7
None 80 LOSS OR DAMAGE TO FACILITY TYPE         DESCRIPTION 7
IIfil8 9~          10
                        .__~N~A"'----------------------------------------------------------------------'                                                                          80 PUBLICITY
[ill}           N/A 7     8 9                                                                                                                                                                       80
  ~        ADDITIONAL FACTORS
  ~        I     Cause Description (Contd) - urgency in making deliveries is expected to forestall 7     8 9                                                                                                                                                                       80 (Tifil I     future delivery problems.
I 7     8 9                                                                                                                                                                       80}}

Revision as of 09:50, 20 October 2019

Corrected LER 1977-034-00 to Clarify Leakage Testing & LER 1977-041-00 to Identify Proper Cause Description of Low Fuel Inventory
ML18348A214
Person / Time
Site: Palisades Entergy icon.png
Issue date: 10/04/1977
From: Hoffman D
Consumers Power Co
To: James Keppler
NRC/RGN-III
References
LER 1977-034-00, LER 1977-041-00
Download: ML18348A214 (3)


Text

consumers

  • 7--,7
-;-
--, .~"""'. ,.......... r Power L;ic...,p0**:.;kii.:.::zL
  • Company General Offices: 212 West Michigan Avenue, .Jackson, Michigan- 49201
  • Area Code 517 788-0550 October 4, l977 Mr James G Keppler Office of Inspection and Inforcement Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60l37 DOCKET 50-255, LICENSE DPR-20 ~

PALISADES PLANT .,.. CORRECTED ER.,-77-034 AND ER-77-041 Licensee Event Report 77-034 reported an apparent high level in safety injection

  • tank SI-82C. In the "cause description" portion of the report, we stated that testing would be performed.to determine the path of apparent leakage.

In August, we determined that the cause of the low level indication was not in leakage, but instead was faulty indication. Inasmuch as the leakage testing initially* proposed is no longer applicable, an updated LER is attached to clarify the* record.

Licensee Event Report 77-041 did not present a clear sequence of events leading to the low fuel inventory. A corrected LER is attached to identify the proper cause description.

David P Hoffman ( S.igned)

David P Hoffman Assistant Nuclear Licensing Administrator CC: ASchwencer, USNRC

-

  • u:iarE - PREVIOUS REPOR'l' DATE 08-01-* CORRECTED

. *LICENSEE EVENT

  • REPORT Palisades eoNTROL BLOCK: I I I I I I I (PLEASE PRINT ALL REQUIRED INFORMATION]

1 6

~ I MI LICENSEE LICENSE EVENT NAME LICENSE NUMBER TYPE TYPE I I Pl A I L I1 I I o I o 1-1 oI oI oI oI ol-1 o I o I 14111111111 I o I 3 I 7 8 9 14 15 25 26 30 31 32 REPORT REPORT TYPE. SOURCE DOCKl;T NUMBER EVENT OATE REPORT DATE

@TI]coN'T l *I *I lLJ LrJ lolslol-lol2l sl sl I ol 11 ol s1 11 ] lol912l917171 7 8 57 58 59 so ~ 68 69 74 75 80 EVENT DESCRIPTION

@:lfil I T-82C safety injectiqn tank level was found to be 1% above Technical Specifications I 7 8 9 80 10131 I limits. The tank was drained to bring indicated level back within Technical I 7 8 9 80 lol4l I Specifications limits. (ER-77-034) I 7 8 9 80 7 8 9...._______________________________________________________________________________________,80

~

lolsl 7 8 9 PRIME 80 SYSTEM CAUSE COMPONENT COMPONENT CODE CODE COMPONENT CODE SUPPLIER MANUFACTURER VIOLATION 7

@El Isl Fl 8 s 10 l!J 11 I Al cI cl d MI u I 12 17 w43 I z I 9 I 9 I 9I 44 47 L1LI 48 CAUSE DESCRIPTION

~ I Subse~uent investigation revealed that the cause of the event was faulty indication. I 7 8 9 80

~ I The indication has been restored to normal and no further action is contemplated. I r.

7 8 9 tlO I (Reference LER 77-40) I 8 9 80 FACILITY METHOD OF STATUS  % PO'NER OTHER STATUS DISCOVERY DISCOVERY DESCRIPTION EE] LI_] I I 0 I 0 I I N /A 1 I ~ llLA 7 8 9 10 12 13 44 45 46 80 FORM OF ACTIVITY CONTENT 7

rn 8 RELEASED w

9 w

OF RELEASE 10 11 I N/A.

AMOUNT OF ACTIVITY 44 l 45 N/A LOCATION OF RELEASE 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION ITEi 10101.01 l.!J I N/A 7 8 9 11 12 13 80 PERSONNEL INJURIES rn 1o1 o 7 8 9 NUMBER 1 01.

11 DESCRIPTION N/A.

1~2------~--------~-------------------------------------------------"'-------8~0 PROBABLE CONSEQUENCES lill] I N /A 7 8 9 80 LOSS OR DAMAGE TO FACILITY TYPE DESCRIPTION

[]]]_ U_J .,,._~N'"'-=A__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,__,~

7 8 9 10 tlO PUBLICITY ITIZJ I N/A 7 8 9 BO A,..., ADDITIONAL FACTORS

~IN/A 7 8 9 80 GE8 9 7 80

-

CORRECTED

.LICENSEE EVENT REPORT

  • Palisades
  • caw AOL BLOCK: I I I I I [PLEASE PRINT ALL REQUIRED INFORMATION]

1 6 LICENSE EVENT LICENSE NUMBER TYPE TYPE lo lo 1-lol ol ol ol ol-lo lo I 14111111!11 Io I 1 I 15 25 26 30 31 32 REPORT REPORT TYPE SOURCE OOCKJ;T NUMBER EVENT DATE REPORT OATE 7

@IT]coN'T 8

r* I *58I L!J 57 59

~

60 1015 lo I-lo 1215151 I oI 8 I 21 3 I 11 11 lol2lol2l1l1I

. 61 68 69 74 75 80 EVENT DESCRIPTION

@lfil I At 1600 on 8/23/77, during routine start-up operations, the level in the diesel oil 7 8 9 80

@El I storage tank, T-10, had decreased to 53 percent. This is the level that provides the I 7 8 9 . 80 loj41 I minimum required volume of 16 ,000 gallons as specified in Technical Specifications I 7 8 9 80

@Jfil I 3. 7 .1. i for heatup above 325°F. Plant cooldown commenced immediately. At 1800 oil I 7 8 9 . ' 80 lfil§] I was delivered and heatup resumed. Problem is not repetit*ive. (ER-77-041) I 7 8 9 PRIME 80 SYSTEM CAUSE COMPONENT COMPONENT CODE COOE COMPONENT CODE SUPPLIER MANUFACTURER VIOLATION 7

@El I El E I LEJ 8 9 10 11 I x Ix I xI xi xi zj 12 17 w 43 44 Iz I9 I9 I9 I 47 w 48 CAUSE DESCRIPTION

~ ._I ....p=-p._l_i_*e_r_f_a_i_l_e_d_t_o_d_e_l_i_*v_e_r_~I

_F_u_e_l_h_a_d_b_ee_n_o_r_d_e_r_e_d_o_n_th_e_m_o_r_n_i_n..:;;g'--o_f_8.:.../2_2...;/_7.:...7.:...'=--b_u_t_t_h_e_su 7 8 9 80 lo191 I that day. Delivery was further delayed on 8/23/77 because of difficulty in obtaining I 7 8 9 80 I a delivery vehicle. Correspondence to the supplier stressing the need for (Contd) I

. .8 9 FACILITY METHOD OF 80 STATUS  % POWER OTHER STATUS DISCOVERY DISCOVERY DESCRIPTION 7

EEi8 W.

9 lo I 0 I 0 I I Routine 10 12 13 Start-Up 44 I LJJ 45 46 I N/A.

80 FORM OF ACTIVITY CONTENT rn w RELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE

~ ._I_...N""""/

A..._,_ _ _ _ _ ___...,. N/A 7 8 9 10 11 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION

~lo lolol ~ i-.;.;N~A;.:_________________________________________________;......J 7 8 9 11 12 13 80 PERSONNEL INJURIES rn 1o NUMBER

, a 1 a1 DESCRIPTION

.__N__/_A_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.....,...,..,.

7 8 9 11 12 . 80 PROBABLE CONSEQUENCES lIJfil8 9 7

None 80 LOSS OR DAMAGE TO FACILITY TYPE DESCRIPTION 7

IIfil8 9~ 10

.__~N~A"'----------------------------------------------------------------------' 80 PUBLICITY

[ill} N/A 7 8 9 80

~ ADDITIONAL FACTORS

~ I Cause Description (Contd) - urgency in making deliveries is expected to forestall 7 8 9 80 (Tifil I future delivery problems.

I 7 8 9 80