ML13219A042: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 3: Line 3:
| issue date = 02/24/2012
| issue date = 02/24/2012
| title = Email from G. Cheruvenki to J. Kim, Inspections Steam Dryer - Todays Meeting at 1:00 P.M
| title = Email from G. Cheruvenki to J. Kim, Inspections Steam Dryer - Todays Meeting at 1:00 P.M
| author name = Cheruvenki G S
| author name = Cheruvenki G
| author affiliation = NRC/NRR
| author affiliation = NRC/NRR
| addressee name = Kim J S
| addressee name = Kim J
| addressee affiliation = NRC/NRR/DORL/LPLI-1
| addressee affiliation = NRC/NRR/DORL/LPLI-1
| docket = 05000271
| docket = 05000271

Revision as of 00:38, 22 June 2019

Email from G. Cheruvenki to J. Kim, Inspections Steam Dryer - Todays Meeting at 1:00 P.M
ML13219A042
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 02/24/2012
From: Ganesh Cheruvenki
Office of Nuclear Reactor Regulation
To: James Kim
Plant Licensing Branch 1
References
FOIA/PA-2013-0139
Download: ML13219A042 (1)


Text

Cheruvenki, Ganesh ,,/From: Sent: To:

Subject:

Cheruvenki, Ganesh i -Friday, February 24, 2b(12 8:20 AM Kim, James RE: Inspections--Steam dryer-Today's meeting at 1.00 pm at 09B6.Jim-Can we talk about our future review today?-Ganesh--415-2501 From: .Kim, James "" Sent: Thursday, February 23, 2012 10:32 AM To: Cheruvenki, Ganesh; Basavaraju, Chakrapani; Scarbrough, Thomas; Jessup, William; Sheng, Simon

Subject:

RE: Inspections--Steam dryer--Today's meeting at 1.00 pm at 09B6.Gentlemen, VY has proposed that both GE and VY representatives are willing to bring the inspections reports (approx. 20 GE proprietary inspection reports) to NRC for tech staff to review the steam dryer inspection reports and answer any questions NRC tech staff may have. Please let me know if this approach is acceptable.

Thanks Jim Kim From: Cheruvenki, Ganesh Sent: Tuesday, February 21, 2012 8:59 AM To: Basavaraju, Chakrapanl; Scarbrough, Thomas; Jessup, William; Sheng, Simon Cc: Kim, James

Subject:

Inspections-Steam dryer--Today's meeting at 1.00 pm at 09B6.Importance:

High Pani, Tom, Simon and Billy Here is my draft report on the inspection results (RF-26, 27 and 28) of the steam dryer and it contains status of new indications.

I still think we need to see the GE evaluation report which can provide information on the licensee's justification for using less frequent inspections.

I j3J30