ENS 40608: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 03/24/2004 03:31 EST | | event date = 03/24/2004 03:31 EST | ||
| last update date = 03/24/2004 | | last update date = 03/24/2004 | ||
| title = Automatic Reactor Trip Due | | title = Automatic Reactor Trip Due to Turbine Trip | ||
| event text = At approximately 0331 EST the reactor tripped due to reactor protection system actuation. The Emergency Feedwater System actuated. | | event text = At approximately 0331 EST the reactor tripped due to reactor protection system actuation. The Emergency Feedwater System actuated. | ||
It appears that a main feedwater perturbation [sensed low feedwater flow] occurred which actuated a main turbine trip. The main turbine trip actuated the reactor protection system which tripped the reactor. | It appears that a main feedwater perturbation [sensed low feedwater flow] occurred which actuated a main turbine trip. The main turbine trip actuated the reactor protection system which tripped the reactor. |
Latest revision as of 21:23, 1 March 2018
Where | |
---|---|
Crystal River Florida (NRC Region 2) | |
Reporting | |
10 CFR 50.72(b)(2)(iv)(B), RPS Actuation 10 CFR 50.72(b)(3)(iv)(A), System Actuation | |
LER: | 05000302/LER-2004-001 |
Time - Person (Reporting Time:+-3.87 h-0.161 days <br />-0.023 weeks <br />-0.0053 months <br />) | |
Opened: | Richard Sweeney 04:39 Mar 24, 2004 |
NRC Officer: | Bill Gott |
Last Updated: | Mar 24, 2004 |
40608 - NRC Website
| |