ML18285A609: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
Line 2: Line 2:
| number = ML18285A609
| number = ML18285A609
| issue date = 09/19/2018
| issue date = 09/19/2018
| title = Limerick Generating Station, Units 1 & 2, Revision 19 to Updated Final Safety Analysis Report, Chapter 13, Conduct of Operations
| title = Revision 19 to Updated Final Safety Analysis Report, Chapter 13, Conduct of Operations
| author name =  
| author name =  
| author affiliation = Exelon Generation Co, LLC
| author affiliation = Exelon Generation Co, LLC

Revision as of 22:21, 30 January 2019

Revision 19 to Updated Final Safety Analysis Report, Chapter 13, Conduct of Operations
ML18285A609
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 09/19/2018
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML18285A591 List:
References
Download: ML18285A609 (61)


Text

LGS UFSAR

Figure 13.1-1 Deleted

LGS UFSAR

Figure 13.1-4 Deleted

_J i i . I .-----< ! ..J i_:***-* d UNIT 1 (1) ONLY CONTROL PANELS ASSOCIATED WITH THE OPERATION OF THAT UNIT OR COMMON UNIT PANELS ARE INCLUDED INSIDE THE DEFINED BOUNDARY.

IF, IN THE FUTURE, PANELS ARE ADDED TO THE CONTROL ROOM, THEY ARE NECES* SARIL Y INCLUDED IN THE DEFINITION OF "AT THE CONTROLS" FOR THAT UNIT. (2l NORMAL "AT THE CONTROLS" LOCATIONS DO NOT APPLY DURING ANY CONDITION DURING WHICH THE CONTROL ROOM IS NOT HABITABLE.

IN THAT EVENT, THE "AT THE CONTROL" LOCATION IS THE EMERGENCY SHUTDOWN PANEL FOR THAT UNIT. (3) IN THE EVENT OF AN EMERGENCY AFFECTING THE SAFETY OF OPERATIONS, THE OPERATOR MAY MOMENTARILY BE ABSENT FROM THE DESIGNATED AREA TO VERIFY THE RECEIPT OF AN ANNUNCIATOR ALARM OR INITIATE CORRECTIVE ACTION. PROVIDED THE OPERATOR REMAINS WITHIN THE CONFINES OF THE CONTROL ROOM AND OBTAINS THE PERMIS* SION OF THE CONTROL ROOM SRO AT THE TIME. [.' ;.; ii' iii *I I I : : 1-i ,_j LIMERICK GENERATING STATION UNITS 1ANO2 UPDATED FINAL SAFETY ANALYSIS REPORT DEFINITION OF "AT THE CONTROLS" SHEET 1 OF 2 FIGURE 13.5-1 REV. 13 09/06 UNIT2 NOTES (1) ONLY CONTROL PANELS ASSOCIATED WITH THE OPERATION OF THAT UNIT OR COMMON UNIT PANELS ARE INCLUDED INSIDE THE DEFINED BOUNDARY.

IF, IN THE FUTURE, PANELS ARE ADDED TO THE CONTROL ROOM, THEY ARE SARIL Y INCLUDED IN THE DEFINITION OF ,.AT THE CONTROLS" FOR THAT UNIT. OFFICE, UTILITY, OR REST FACILITIES ARE NOT INCLUDED IN THE DEFINED BOUNDARY WITH THE FOLLOWING EXCEPTION:

THE UNIT 2 OPERATOR MAY OPEN THE SHIFT SUPERINTENDENT OFFICE DOOR, FOR VERBAL COMMUNICATION AS LONG AS HE REMAINS IN THE AREA CIR* CUMSCRIBEO BY THE DOOR ANO THE DOOR IS HELO OPEN. (2) NORMAL "AT THE CONTROLS., LOCATIONS DO NOT APPLY DURING ANY CONDITION DURING WHICH THE CONTROL ROOM IS NOT HABITABLE.

IN THAT EVENT, THE "AT THE CONTROL" LOCATION IS THE EMERGENCY SHUTDOWN PANEL FOR THAT UNIT. 13) IN THE EVENT OF AN EMERGENCY AFFECTING THE SAFETY OF OPERATIONS, THE OPERATOR MAY MOMENTARILY BE ABSENT FROM THE DESIGNATED AREA TO VERIFY THE RECEIPT OF AN ANNUNCIATOR ALARM OR INITIATE CORRECTIVE ACTION, PROVIDED THE OPERATOR REMAINS WITHIN THE CONFINES OF THE CONTROL ROOM ANO OBTAINS THE PERMIS-SION OF THE CONTROL ROOM SRO AT THE TIME. . I I I I J .. . .,, i!* "' 'l* : l;I ., I I LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY .ANALYSIS REPORT DEFINITION OF AT THE CONTROLS" SHEET 2 OF 2 FIGURE. 13.5*1 REV. 13 09{9_6_

I I I Ii 1-1 . *-_:.?

I : *. I ':= atlU_, I ' ; * ., . ., I . ! : I I . -..... ...,.

I I. . I 11) ONLY CONTROL PANELS ASSOCIATED WITH THE OPERATION OF THAT UNIT OR COMMON UNIT PANELS ARE INCLUDED INSIDE THE DEFINED BOUNDARY.

IF. IN THE FUTURE, PANELS ARE ADDED TO THE CONTROL ROOM, THEY ARE SARILY INCLUDED IN THE DEFINITION OF "AT THE CONTROLS" FOR THAT UNIT. OFFICE, UTILITY, OR REST FACILITIES ARE NOT INCLUDED IN THE DEFINED BOUNDARY WITH THE FOLLOWING EXCEPTION

THE SRO MAY OPEN THE SHIFT SUPERINTENDENT OR ADJACENT OFFICE INSTRUMENT LAB, ANO SHOP DOORS FOR VERBAL COMMUNICATION AS LONG AS HE REMAINS IN THE AREA CIRCUMSCRIBED BY THE DOOR ANO THE DOOR IS HELD OPEN. -

i* I .,, ...... ; .: ** I* LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY ANALYSIS REPORT SAO CONTROL ROOM BOUNDARIES FIGURE 13.5-2 REV. 13 09/06