ENS 40909: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 07/30/2004 09:45 EDT
| event date = 07/30/2004 09:45 EDT
| last update date = 07/30/2004
| last update date = 07/30/2004
| title = Reactor Core Isolation Cooling (Rcic) Turbine Failed To Achieve Design Pressure And Flow During Surveillance Testing
| title = Reactor Core Isolation Cooling (Rcic) Turbine Failed to Achieve Design Pressure and Flow During Surveillance Testing
| event text = The following information was obtained from the licensee via facsimile:
| event text = The following information was obtained from the licensee via facsimile:
During a surveillance of the Reactor Core Isolation Cooling system (RCIC), the RCIC turbine failed to achieve design pressure and flow.  Other safety systems, including the High Pressure Coolant Injection (HPCI) system, are available.  
During a surveillance of the Reactor Core Isolation Cooling system (RCIC), the RCIC turbine failed to achieve design pressure and flow.  Other safety systems, including the High Pressure Coolant Injection (HPCI) system, are available.  

Latest revision as of 22:23, 1 March 2018

ENS 40909 +/-
Where
Pilgrim
Massachusetts (NRC Region 1)
Reporting
10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident
Time - Person (Reporting Time:+-0.9 h-0.0375 days <br />-0.00536 weeks <br />-0.00123 months <br />)
Opened: John Webers
12:51 Jul 30, 2004
NRC Officer: Howie Crouch
Last Updated: Jul 30, 2004
40909 - NRC Website
Loading map...