ENS 40909
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
13:45 Jul 30, 2004 | |
| Title | Reactor Core Isolation Cooling (Rcic) Turbine Failed to Achieve Design Pressure and Flow During Surveillance Testing |
| Event Description | The following information was obtained from the licensee via facsimile:
During a surveillance of the Reactor Core Isolation Cooling system (RCIC), the RCIC turbine failed to achieve design pressure and flow. Other safety systems, including the High Pressure Coolant Injection (HPCI) system, are available. This failure is believed to be due to a RCIC flow controller problem. Investigation is continuing. Design pressure/flow is 1250 psig/400 gpm. Actual pressure/flow was 1220 psig/350 gpm. The licensee has notified the NRC Resident Inspector. |
| Where | |
|---|---|
| Pilgrim Massachusetts (NRC Region 1) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
| Time - Person (Reporting Time:+-0.9 h-0.0375 days <br />-0.00536 weeks <br />-0.00123 months <br />) | |
| Opened: | John Webers 12:51 Jul 30, 2004 |
| NRC Officer: | Howie Crouch |
| Last Updated: | Jul 30, 2004 |
| 40909 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 40909\u003C/a\u003E - \u003Ca href=\"/Pilgrim\" title=\"Pilgrim\"\u003EPilgrim\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EReactor Core Isolation Cooling (Rcic) Turbine Failed to Achieve Design Pressure and Flow During Surveillance Testing\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 40909 - Pilgrim\n","link":"","lat":41.942861111111114,"lon":-70.57673055555556,"icon":""}],"imageoverlays":null} | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_40909&oldid=428437"