Line 16: Line 16:
| event date = 05/22/2012 PDT
| event date = 05/22/2012 PDT
| last update date = 06/14/2012
| last update date = 06/14/2012
| title = Agreement State Report - Camera Source Fails To Retract
| title = Agreement State Report - Camera Source Fails to Retract
| event text = The agreement State of California reported the following via email:
| event text = The agreement State of California reported the following via email:
On 06/13/12, the RSO at Team Industrial contacted RHB to report a radiography camera incident that occurred on 05/22/12 at the Evergreen refinery in Newalk, CA.  The radiographers were using a QSA 880 camera on the second deck of the unit 1 at this refinery.  The radiographer cranked the 59 Ci source out into the collimator and after the exposure, he couldn't retrieve the source back into the shielded position. He immediately contacted the RSO.  Per  RSO's instructions, the radiographer unscrewed the crank assembly and pulled the cable back to retrieve the source into shielded position. There were no exposures to the radiographers, two assistants, and any member of the public.  The licensee's Instadose dosimetry indicated 8 mR for the radiographer for the period of 5/18 - 5/22 and 7 mR and 0 mR for the two assistants for the same period.  Their pocket dosimeters indicated zero exposure for all three individuals.
On 06/13/12, the RSO at Team Industrial contacted RHB to report a radiography camera incident that occurred on 05/22/12 at the Evergreen refinery in Newalk, CA.  The radiographers were using a QSA 880 camera on the second deck of the unit 1 at this refinery.  The radiographer cranked the 59 Ci source out into the collimator and after the exposure, he couldn't retrieve the source back into the shielded position. He immediately contacted the RSO.  Per  RSO's instructions, the radiographer unscrewed the crank assembly and pulled the cable back to retrieve the source into shielded position. There were no exposures to the radiographers, two assistants, and any member of the public.  The licensee's Instadose dosimetry indicated 8 mR for the radiographer for the period of 5/18 - 5/22 and 7 mR and 0 mR for the two assistants for the same period.  Their pocket dosimeters indicated zero exposure for all three individuals.

Latest revision as of 22:03, 1 March 2018

ENS 48025 +/-
Where
Team Industrial Services
Benicia, California (NRC Region 4)
License number: 6720-48
Organization: California Radiation Control Prgm
Reporting
Agreement State
Time - Person (Reporting Time:+558.07 h23.253 days <br />3.322 weeks <br />0.764 months <br />)
Opened: Kent Prendergast
13:04 Jun 14, 2012
NRC Officer: Pete Snyder
Last Updated: Jun 14, 2012
48025 - NRC Website