Line 2: Line 2:
| number = ML18024A335
| number = ML18024A335
| issue date = 10/05/2017
| issue date = 10/05/2017
| title = Browns Ferry Nuclear Plant Updated Final Safety Analysis Report (Ufsar), Amendment 27, 14.4 Table - Approach to Safety Analysis
| title = Updated Final Safety Analysis Report (Ufsar), Amendment 27, 14.4 Table - Approach to Safety Analysis
| author name =  
| author name =  
| author affiliation = Tennessee Valley Authority
| author affiliation = Tennessee Valley Authority
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:BFN-16   TABLE 14.4-1  
{{#Wiki_filter:BFN-16 TABLE 14.4-1 (Sheet 1)
 
PLANT SAFETY ANALYSIS
(Sheet 1)  
 
PLANT SAFETY ANALYSIS  


==SUMMARY==
==SUMMARY==
OF ABNORMAL OPERATIONAL TRANSIENTS  
OF ABNORMAL OPERATIONAL TRANSIENTS Undesired Parameter                             Event Causing Variation                                     Transient                   Scram Caused by Nuclear system pressure                     Generator trip without         Turbine control valve increase                                     bypass                         fast closure Nuclear system pressure                     Turbine trip without           Turbine stop valve increase                                     bypass                         closure Nuclear system pressure                     Main steam line isolation     Main steam line isolation increase                                     valve closure                 valve closure Nuclear system pressure                      Loss of Condenser vacuum      Turbine stop valve closure increase Nuclear system pressure                      Bypass valve malfunction      Reactor vessel high pressure increase Nuclear system pressure                      Pressure regulator            Reactor vessel high pressure increase                                    malfunction Reactor water temperature                    Shutdown cooling malfunction  High Neutron flux decrease                                    decrease temperature Reactor water temperature                    Loss of feedwater heater*      None decrease Reactor Water temperature                    Inadvertent pump start*        None decrease Positive reactivity                          Continuous rod withdrawal      None insertion                                    during power range operation*
 
Positive reactivity                          Continuous rod withdrawal      High neutron flux insertion                                    during reactor startup*
Undesired Parameter     Event Causing       Variation                       Transient         Scram Caused by  
Positive reactivity                          Control rod removal error      High neutron flux insertion                                    during refueling Positive reactivity                          Fuel assembly insertion        High neutron flux insertion                                    error during refueling Coolant inventory decrease                  Pressure regulator            Main steam line isolation failure - open**              valve closure Coolant inventory decrease                  Open main steam relief valve**
 
Coolant inventory decrease                  Loss of feedwater flow        Reactor vessel low water level
Nuclear system pressure Generator trip without Turbine control valve increase bypass fast closure  
*This transient results in no significant change in nuclear system pressure.
 
**This transient results in a depressurization.
Nuclear system pressure Turbine trip without Turbine stop valve   increase bypass closure  
 
Nuclear system pressure Main steam line isolation Main st eam line isolation   increase valve closure valve closure  


Nuclear system pressure Loss of Condenser vacuum Turbine stop valve closure
BFN-16 TABLE 14.4-1 (Sheet 2)
 
PLANT SAFETY ANALYSIS
increase Nuclear system pressure Bypass valve malfunction Reactor vessel high pressure increase
 
Nuclear system pressure Pressure regulator Reactor vessel high pressure  increase malfunction Reactor water temperature Shutdown cooling malfunction High Neutron flux    decrease decrease temperature 
 
Reactor water temperature Loss of feedwater heater* None decrease
 
Reactor Water temperature Inadvertent pump start* None  decrease
 
Positive reactivity  Continuous rod withdrawal None insertion during power range operation*
Positive reactivity Continuous rod withdrawal High neutron flux  insertion during reactor startup*
 
Positive reactivity Control rod removal error High neutron flux    insertion during refueling 
 
Positive reactivity Fuel assembly insertion High neutron flux  insertion error during refueling 
 
Coolant inventory decrease Pressure regulator Main steam line isolation failure - open** valve closure Coolant inventory decrease  Open main steam relief valve**
 
Coolant inventory decrease Loss of feedwater flow Reactor vessel low water level
 
*This transient results in no significant change in nuclear system pressure.
**This transient results in a depressurization.
BFN-16   TABLE 14.4-1 (Sheet 2)
PLANT SAFETY ANALYSIS  


==SUMMARY==
==SUMMARY==
OF ABNORMAL OPERATIONAL TRANSIENTS Undesired Parameter     Event Causing           Variation                     Transient             Scram Caused by Coolant inventory decrease Loss of auxiliary power Loss of power to reactor system protection Core flow decrease Recirculation flow control None failure - decreasing flow**
OF ABNORMAL OPERATIONAL TRANSIENTS Undesired Parameter                         Event Causing Variation                                 Transient                         Scram Caused by Coolant inventory decrease               Loss of auxiliary power             Loss of power to reactor system                             protection Core flow decrease                       Recirculation flow control         None failure - decreasing flow**
Core flow decrease Trip of one recirculation None pump**   Core flow decrease Trip of two recirculation None pumps**   Core flow increase Recirculation pump flow High neutron flux control failure increasing flow*   Core flow increase Startup of idle recirculation pump* None Excess of coolant Feedwater Controller Turbine stop valve closure   inventory failure-maximum demand  
Core flow decrease                       Trip of one recirculation           None pump**
 
Core flow decrease                       Trip of two recirculation           None pumps**
    *This transient results in no significant change in nuclear system pressure.  
Core flow increase                       Recirculation pump flow             High neutron flux control failure increasing flow*
  **This transient results in a depressurization.  
Core flow increase                       Startup of idle recirculation pump*                 None Excess of coolant                       Feedwater Controller               Turbine stop valve closure inventory                               failure-maximum demand
 
*This transient results in no significant change in nuclear system pressure.
BFN-17  TABLE 14.4-2 PLANT SAFETY ANALYSIS RESULTS OF DESIGN BASIS ACCIDENTS Percent of Core  Design Basis Reaching Cladding      Peak      Accident  Temperature of 2200
**This transient results in a depressurization.
°F System Pressure 
 
Rod Drop  Not applicable*** <1375 psig  Accident Loss of Coolant  0 Not applicable*  Accident Refueling Accident  0 Not applicable** 


Main Steam Line   0 Not applicable* Break Accident  
BFN-17 TABLE 14.4-2 PLANT SAFETY ANALYSIS RESULTS OF DESIGN BASIS ACCIDENTS Percent of Core Design Basis              Reaching Cladding                Peak Accident                Temperature of 2200&deg;F      System Pressure Rod Drop                  Not applicable***          <1375 psig Accident Loss of Coolant                  0                    Not applicable*
        *This accident results in a depressurization.  
Accident Refueling Accident              0                    Not applicable**
  **This accident occurs wi th the reactor vessel head off.   ***Peak fuel enthalpy is less than 280 cal/gm.}}
Main Steam Line                 0                   Not applicable*
Break Accident
  *This accident results in a depressurization.
  **This accident occurs with the reactor vessel head off.
***Peak fuel enthalpy is less than 280 cal/gm.}}

Latest revision as of 03:11, 22 October 2019

Updated Final Safety Analysis Report (Ufsar), Amendment 27, 14.4 Table - Approach to Safety Analysis
ML18024A335
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 10/05/2017
From:
Tennessee Valley Authority
To:
Office of Nuclear Reactor Regulation
Shared Package
ML18018A778 List: ... further results
References
Download: ML18024A335 (3)


Text

BFN-16 TABLE 14.4-1 (Sheet 1)

PLANT SAFETY ANALYSIS

SUMMARY

OF ABNORMAL OPERATIONAL TRANSIENTS Undesired Parameter Event Causing Variation Transient Scram Caused by Nuclear system pressure Generator trip without Turbine control valve increase bypass fast closure Nuclear system pressure Turbine trip without Turbine stop valve increase bypass closure Nuclear system pressure Main steam line isolation Main steam line isolation increase valve closure valve closure Nuclear system pressure Loss of Condenser vacuum Turbine stop valve closure increase Nuclear system pressure Bypass valve malfunction Reactor vessel high pressure increase Nuclear system pressure Pressure regulator Reactor vessel high pressure increase malfunction Reactor water temperature Shutdown cooling malfunction High Neutron flux decrease decrease temperature Reactor water temperature Loss of feedwater heater* None decrease Reactor Water temperature Inadvertent pump start* None decrease Positive reactivity Continuous rod withdrawal None insertion during power range operation*

Positive reactivity Continuous rod withdrawal High neutron flux insertion during reactor startup*

Positive reactivity Control rod removal error High neutron flux insertion during refueling Positive reactivity Fuel assembly insertion High neutron flux insertion error during refueling Coolant inventory decrease Pressure regulator Main steam line isolation failure - open** valve closure Coolant inventory decrease Open main steam relief valve**

Coolant inventory decrease Loss of feedwater flow Reactor vessel low water level

  • This transient results in no significant change in nuclear system pressure.
    • This transient results in a depressurization.

BFN-16 TABLE 14.4-1 (Sheet 2)

PLANT SAFETY ANALYSIS

SUMMARY

OF ABNORMAL OPERATIONAL TRANSIENTS Undesired Parameter Event Causing Variation Transient Scram Caused by Coolant inventory decrease Loss of auxiliary power Loss of power to reactor system protection Core flow decrease Recirculation flow control None failure - decreasing flow**

Core flow decrease Trip of one recirculation None pump**

Core flow decrease Trip of two recirculation None pumps**

Core flow increase Recirculation pump flow High neutron flux control failure increasing flow*

Core flow increase Startup of idle recirculation pump* None Excess of coolant Feedwater Controller Turbine stop valve closure inventory failure-maximum demand

  • This transient results in no significant change in nuclear system pressure.
    • This transient results in a depressurization.

BFN-17 TABLE 14.4-2 PLANT SAFETY ANALYSIS RESULTS OF DESIGN BASIS ACCIDENTS Percent of Core Design Basis Reaching Cladding Peak Accident Temperature of 2200°F System Pressure Rod Drop Not applicable*** <1375 psig Accident Loss of Coolant 0 Not applicable*

Accident Refueling Accident 0 Not applicable**

Main Steam Line 0 Not applicable*

Break Accident

  • This accident results in a depressurization.
    • This accident occurs with the reactor vessel head off.
      • Peak fuel enthalpy is less than 280 cal/gm.