BFN-16 Table 3.3-1 REACTOR VESSEL INTERNALS, DESIGN DATA Core Shroud Jet Pumps Upper Portion,o.d.,in. ................ 220 Number .......................................................... 20 Central Portion,o.d.,in. ............ 207 Throat Diameter,in. ..................................... 8.18 Lower Portion,o.d.,in. ................ 201 Weight,lb. ............................................... 22,700 Central Portion, thickness, in. ...... 2 Steam Dryers Weight, lb. .......................... 116,900 Weight,lb. ............................................... 90,000 Shroud Head-Steam Separator Assembly Feedwater Sparger Head Thickness, in. .............. 2.0 Dimensions,in. .............................. 6 Sched. 40 Number of Separators .......... 211 Cross Section Area,ft2 ............................. 0.2006 Separator,o.d.,in. ................. 12.75 Number ............................................................ 6 Standpipe,i.d.,in. .................. 6.065 Core Spray Sparger Rings Standpipe,o.d.,in. ................. 6.625 Diameter,in. ............................. 4 Sched. 40 S Weight,lb. ........................ 139,600 Cross Section Area,ft2 ............................... 0.088 Core Support Number of Spray Outlets ............................... 260 Weight,lb. .......................... 20,500 Weight,lb. ........................................... 4,317 Top Guide Vessel Head Cooling Spray Nozzle Weight,lb. ............................. 15,200 Pipe Size,in. .................................................... 4 Fuel Support Pieces Schedule ......................................................... 40 Number of Preipheral .................. 24 Differential Pressure & Liquid Control Line Four Lobe Inner Pipe (Liquid Control),in. .............. 1 Sched. 40 Number without Plugs ........... 185 Outer Pipe,in. ............................... 2 Sched. 40 Number with Plugs .................. 0 Incore Flux Monitor Guide Tubes Weight,lb. ............................ 11,300 Number ..................................................... 55 Control Rod Guide Tubes Number ...................................... 185 Weight,lb. ............................ 46,250 Surveillance Sample Holders .................................. 3 Total Weight of Reactor Vessel Internals, pounds (excluding fuel) .......... 477,000