ML21286A552
| ML21286A552 | |
| Person / Time | |
|---|---|
| Site: | Browns Ferry (DPR-033, DPR-052, DPR-068) |
| Issue date: | 10/04/2021 |
| From: | Tennessee Valley Authority |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML21286A574 | List:
|
| References | |
| Download: ML21286A552 (82) | |
Text
BFN-19 Figures 14.5-1, 14.5-2, 14.5-3, and 14.5-4 Deleted by Amendment 19
BFN-28 Figure 14.5-5 Deleted by Amendment 28
BFN-28 Figure 14.5-5a EOC LRNB at 100P/105F with TSSS Key Parameters
BFN-28 Figure 14.5-5b EOC LRNB at 100P/105F with TSSS Sensed Water Level
BFN-28 Figure 14.5-5c EOC LRNB at 100P/105F with TSSS Vessel Pressures
BFN-28 Figure 14.5-6 Deleted by Amendment 28
BFN-28 Figure 14.5-6a LRNB with EOC-RPT-OOS at 100P/105F with TSSS Key Parameters
BFN-28 Figure 14.5-6b LRNB with EOC-RPT-OOS at 100P/105F with TSSS Sensed Water Level
BFN-28 Figure 14.5-6c LRNB with EOC-RPT-OOS at 100P/105F with TSSS Vessel Pressures
BFN-28 Figure 14.5-7a Deleted by Amendment 28
BFN-28 Figure 14.5-7b Deleted by Amendment 28
BFN-28 Figure 14.5-8 Deleted by Amendment 28
BFN-28 Figure 14.5-9 Deleted by Amendment 28
BFN-28 Figure 14.5-9a TTNB at 100P/105F with TSSS Key Parameters
BFN-28 Figure 14.5-9b TTNB at 100P/105F with TSSS Sensed Water Level
BFN-28 Figure 14.5-9c TTNB at 100P/105F with TSSS Vessel Pressures
BFN-28 Figure 14.5-10a Deleted by Amendment 28
BFN-28 Figure 14.5-10b Deleted by Amendment 28
BFN-28 Figure 14.5-11 Deleted by Amendment 28
BFN-28 Figure 14.5-11a MSIV Closure Overpressurization Event at 102P/105F with TSSS Key Parameters
BFN-28 Figure 14.5-11b MSIV Closure Overpressurization Event at 102P/105F with TSSS Sensed Water Level
BFN-28 Figure 14.5-11c MSIV Closure Overpressurization Event at 102P/105F with TSSS Vessel Pressures*
The pressure presented in this figure do not include the adjustments associated with NRC concerns with the void-quality correlation, exposure-dependent thermal conductivity, and Doppler efforts.
BFN-28 Figure 14.5-11d MSIV Closure Overpressurization Event at 102P/105F with TSSS Safety/Relief Valve Flow Rates
BFN-28 Figure 14.5-12a One MSIV Closure at 100P/105F with TSSS Key Parameters
BFN-28 Figure 14.5-12b One MSIV Closure at 100P/105F with TSSS Sensed Water Level
BFN-28 Figure 14.5-12c One MSIV Closure at 100P/105F with TSSS Vessel Pressures
BFN-28 Figure 14.5-13a Deleted by Amendment 28
BFN-28 Figure 14.5-13b Deleted by Amendment 28
BFN-28 Figure 14.5-14a Deleted by Amendment 28
BFN-28 Figure 14.5-14b Deleted by Amendment 28
BFN-28 Figure 14.5-15a Pressure Regulator Failure Open 2075 MWt / 35F
BFN-28 Figure 14.5-15b Pressure Regulator Failure Open 2075 MWt / 35F
BFN-28 Figure 14.5-16a Deleted by Amendment 28
BFN-28 Figure 14.5-16b Deleted by Amendment 28
BFN-28 Figure 14.5-17a Deleted by Amendment 28
BFN-28 Figure 14.5-17b Deleted by Amendment 28
BFN-28 Figure 14.5-17c Deleted by Amendment 28
BFN-28 Figure 14.5-18a Deleted by Amendment 28
BFN-28 Figure 14.5-18b Deleted by Amendment 28
BFN-28 Figure 14.5-19a Deleted by Amendment 28
BFN-28 Figure 14.5-19b Deleted by Amendment 28
BFN-28 Figure 14.5-20a Deleted by Amendment 28
BFN-28 Figure 14.5-20b Deleted by Amendment 28
BFN-28 Figure 14.5-21a Deleted by Amendment 28
BFN-28 Figure 14.5-21b Deleted by Amendment 28
BFN-26 Figure 14.5-22a Deleted by Amendment 26
BFN-26 Figure 14.5-22b Deleted by Amendment 26
BFN-28 Figure 14.5-22c Deleted by Amendment 28
BFN-28 Figure 14.5-22d Deleted by Amendment 28
BFN-28 Figure 14.5-22e Deleted by Amendment 28
BFN-28 Figure 14.5-22f Deleted by Amendment 28
BFN-28 Figure 14.5-23a Deleted by Amendment 28
BFN-28 Figure 14.5-23b Deleted by Amendment 28
BFN-26 Figure 14.5-24a Deleted by Amendment 26
BFN-28 Figure 14.5-24b Deleted by Amendment 28
BFN-28 Figure 14.5-24c Fast Recirculation Pump Runup at 66P/52F Key Parameters
BFN-28 Figure 14.5-24d Fast Recirculation Pump Runup at 66P/52F Sensed Water Level
BFN-28 Figure 14.5-24e Fast Recirculation Pump Runup at 66P/52F Vessel Pressures
BFN-28 Figure 14.5-24f Fast Recirculation Pump Runup at 66P/52F Recirculation Pump Speed
BFN-28 Figure 14.5-25a Deleted by Amendment 28
BFN-26 Figure 14.5-25b Deleted by Amendment 26
BFN-28 Figure 14.5-25c 105% OLTP Idle Loop Startup at 75P/52F Key Parameters
BFN-28 Figure 14.5-25d 105% OLTP Idle Loop Startup at 75P/52F Sensed Water Level
BFN-28 Figure 14.5-25e 105% OLTP Idle Loop Startup at 75P/52F Core Inlet Enthalpy BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT IDLE RECIRCULATION LOOP STARTUP 75P/52F VFD SPEED CONTROL 100FIDLE LOOP 400 RPM MAX. PUMP SPEED FIGURE 14.5-25e
BFN-28 Figure 14.5-25f 105% OLTP Idle Loop Startup at 75P/52F Loop Flows
BFN-28 Figure 14.5-26a Deleted by Amendment 28
BFN-28 Figure 14.5-26b Deleted by Amendment 28
BFN-28 Figure 14.5-27a Deleted by Amendment 28
BFN-28 Figure 14.5-27b Deleted by Amendment 28
BFN-28 Figure 14.5-28 Deleted by Amendment 28
BFN-28 Figure 14.5-28a FWCF at 77.6P/109F with TSSS Key Parameters
BFN-28 Figure 14.5-28b FWCF at 77.6P/109F with TSSS Sensed Water Level
BFN-28 Figure 14.5-28c FWCF at 77.6P/109F with TSSS Vessel Pressures
BFN-28 Figure 14.5-29 Deleted by Amendment 28
BFN-28 Figure 14.5-30 Deleted by Amendment 28
BFN-28 Figure 14.5-30a FWCF with EOC-RPT-OOS at 100P/105F with TSSS Key Parameters
BFN-28 Figure 14.5-30b FWCF with EOC-RPT-OOS at 100P/105F with TSSS Sensed Water Level
BFN-28 Figure 14.5-30c FWCF with EOC-RPT-OOS at 100P/105F with TSSS Vessel Pressures
BFN-28 Figure 14.5-31 Deleted by Amendment 28
BFN-28 Figure 14.5-31a FWCF with TBVOOS at 100P/105F with TSSS Key Parameters
BFN-28 Figure 14.5-31b FWCF with TBVOOS at 100P/105F with TSSS Sensed Water Level
BFN-28 Figure 14.5-31c FWCF with TBVOOS at 100P/105F with TSSS Vessel Pressures