ML18054B102: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| (4 intermediate revisions by the same user not shown) | |||
| Line 3: | Line 3: | ||
| issue date = 11/14/1989 | | issue date = 11/14/1989 | ||
| title = Provides Interpretation of Setpoints Specified in Tech Spec 3.1.8 to Allow +22 Psia for Pressure Instrument Inaccuracy & +/- 4.5 F for Temp Instrument Inaccuracy.Nrc Approval of 890922 Change to Tech Spec Will Obviate Interpretation | | title = Provides Interpretation of Setpoints Specified in Tech Spec 3.1.8 to Allow +22 Psia for Pressure Instrument Inaccuracy & +/- 4.5 F for Temp Instrument Inaccuracy.Nrc Approval of 890922 Change to Tech Spec Will Obviate Interpretation | ||
| author name = | | author name = Berry K | ||
| author affiliation = CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.), | | author affiliation = CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.), | ||
| addressee name = | | addressee name = | ||
| Line 13: | Line 13: | ||
| document type = CORRESPONDENCE-LETTERS, INCOMING CORRESPONDENCE, UTILITY TO NRC | | document type = CORRESPONDENCE-LETTERS, INCOMING CORRESPONDENCE, UTILITY TO NRC | ||
| page count = 2 | | page count = 2 | ||
| project = TAC:72889 | |||
| stage = Other | |||
}} | }} | ||
=Text= | =Text= | ||
{{#Wiki_filter:f. consumers Power POW ERi Nii MICHlliAN'S PROliRESS | {{#Wiki_filter:f. | ||
consumers Power POW ERi Nii MICHlliAN'S PROliRESS General Offices: | |||
-PALISADES PLANT -TECHNICAL SPECIFICATION 3.1.8 -LETTER OF INTERPRETATION | 1945 West Parnall Road, Jackson, Ml 49201 o (517) 788-1636 November 14, 1989 Nuclear Regulatory Connnission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR~20 - PALISADES PLANT - | ||
TECHNICAL SPECIFICATION 3.1.8 - LETTER OF INTERPRETATION Kenneth W Berry Director Nuclear Licensing Technical Specification 3.1.8 specifies that when the PCS temperature is less than or equal to 300°F, two PORVs with a lift setting of less than or equal to 310 psia shall be operable; and, when the PCS temperature is greater than 300°F but less than 430°F, two PORVs with a lift setting of less than or equal to 575 psia will be operable. | |||
that when the PCS temperature is less than or equal to 300°F, two PORVs with a lift setting of less than or equal to 310 psia shall be operable; and, when the PCS temperature is greater than 300°F but less than 430°F, two PORVs with a lift setting of less than or equal to 575 psia will be operable. | |||
Consumers Power Company interprets the 310 psia and 575 psia PORV maximum setpoints specified in Technical Specification 3.1.8 to allow +22 psia for pressure instrument inaccuracy. | Consumers Power Company interprets the 310 psia and 575 psia PORV maximum setpoints specified in Technical Specification 3.1.8 to allow +22 psia for pressure instrument inaccuracy. | ||
Consumers Power Company also interprets the 300°F and 430°F setpoints specified in Technical Specification 3.1.8 to allow +/-4.5°F for temperature instrument inaccuracy. | Consumers Power Company also interprets the 300°F and 430°F setpoints specified in Technical Specification 3.1.8 to allow | ||
These tolerances are technically justifiable because the maximum allowable setpoints specified in the Technical Specifications are at least 32 psi lower than the 10 CFR 50 Appendix G curve, providing ample margin for instrument inaccuracies plus pressure overshoot (Ref. 1). In addition, the required 10 CFR 50 Appendix G pressure/temperature limits as displayed on Figures 3-1 and 3-2 of the Technical Specifications include an additional allowance of 30 psi for pressure measurement errors and 5°F for temperature measurement errors. A proposed change to Technical Specification 3.1.8 that changed the maximum allowable PORV setpoints and addressed the consideration of_allowable setpoint tolerances was submitted September 22, 1989 (Tac No. 72889). NRC approval of that proposed change will obviate this Letter of Interpretation, thus, this letter of interpretation shall be terminated at that time. Meanwhile, Consumers Power Company will not consider it a reportable event if the PORV setpoints are found to deviate from the specified pressure (310 psia or 575 psia) or temperature* | +/-4.5°F for temperature instrument inaccuracy. | ||
(300°F or 430°F) setpoints as long as the deviations are with in the allowable instrument inaccuracy ranges (+/-22 psia and +/-4.5°F). | These tolerances are technically justifiable because the maximum allowable setpoints specified in the Technical Specifications are at least 32 psi lower than the 10 CFR 50 Appendix G curve, providing ample margin for instrument inaccuracies plus pressure overshoot (Ref. 1). | ||
*=*o:::i *L 1- | In addition, the required 10 CFR 50 Appendix G pressure/temperature limits as displayed on Figures 3-1 and 3-2 of the Technical Specifications include an additional allowance of 30 psi for pressure measurement errors and 5°F for temperature measurement errors. | ||
A proposed change to Technical Specification 3.1.8 that changed the maximum allowable PORV setpoints and addressed the consideration of_allowable setpoint tolerances was submitted September 22, 1989 (Tac No. 72889). | |||
* PDR ADOCK Ct50<J0255, /\oo f :p "PDC OC1189-0011-NL02 A CMS ENERGY COMPANY | NRC approval of that proposed change will obviate this Letter of Interpretation, thus, this letter of interpretation shall be terminated at that time. | ||
* _r J e ** | Meanwhile, Consumers Power Company will not consider it a reportable event if the PORV setpoints are found to deviate from the specified pressure (310 psia or 575 psia) or temperature* (300°F or 430°F) setpoints as long as the deviations are with in the allowable instrument inaccuracy ranges (+/-22 psia and +/-4.5°F). | ||
rl=:91--1::::*1~C1!*i-c**-:* *=*o:::i *L 1--1---"--~ | |||
Kenneth W Berry Director, Nuclear Licensing CC Administrator, Region III, USNRC NRC Resident Inspector Palisades Reference | * ""1'. | ||
: 1. Engineering Analysis E-PAL-89-015-01, LTOP Setpoint Margins. OC1189-0011-NL02 2}} | * PDR ADOCK Ct50<J0255, | ||
/\\oo f | |||
:p "PDC | |||
~ | |||
OC1189-0011-NL02 A CMS ENERGY COMPANY | |||
* _r J | |||
e ** | |||
-~ | |||
Nµelear Regulatory Commission Palisages Nuclear Plant TS 3.1.8 - Ltr of Interpretation November 14, 1989 This letter supersedes Consumers Power Company {{letter dated|date=July 12, 1989|text=letter dated July 12, 1989}}. | |||
The earlier letter of interpretation for technical sp~cification addressed only the allowable variation of the pressure setpoint. | |||
Kenneth W Berry Director, Nuclear Licensing CC Administrator, Region III, USNRC NRC Resident Inspector ~ Palisades Reference | |||
: 1. | |||
Engineering Analysis E-PAL-89-015-01, LTOP Setpoint Margins. | |||
OC1189-0011-NL02 2}} | |||
Latest revision as of 09:09, 6 January 2025
| ML18054B102 | |
| Person / Time | |
|---|---|
| Site: | Palisades |
| Issue date: | 11/14/1989 |
| From: | Berry K CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| TAC-72889, NUDOCS 8911210082 | |
| Download: ML18054B102 (2) | |
Text
f.
consumers Power POW ERi Nii MICHlliAN'S PROliRESS General Offices:
1945 West Parnall Road, Jackson, Ml 49201 o (517) 788-1636 November 14, 1989 Nuclear Regulatory Connnission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR~20 - PALISADES PLANT -
TECHNICAL SPECIFICATION 3.1.8 - LETTER OF INTERPRETATION Kenneth W Berry Director Nuclear Licensing Technical Specification 3.1.8 specifies that when the PCS temperature is less than or equal to 300°F, two PORVs with a lift setting of less than or equal to 310 psia shall be operable; and, when the PCS temperature is greater than 300°F but less than 430°F, two PORVs with a lift setting of less than or equal to 575 psia will be operable.
Consumers Power Company interprets the 310 psia and 575 psia PORV maximum setpoints specified in Technical Specification 3.1.8 to allow +22 psia for pressure instrument inaccuracy.
Consumers Power Company also interprets the 300°F and 430°F setpoints specified in Technical Specification 3.1.8 to allow
+/-4.5°F for temperature instrument inaccuracy.
These tolerances are technically justifiable because the maximum allowable setpoints specified in the Technical Specifications are at least 32 psi lower than the 10 CFR 50 Appendix G curve, providing ample margin for instrument inaccuracies plus pressure overshoot (Ref. 1).
In addition, the required 10 CFR 50 Appendix G pressure/temperature limits as displayed on Figures 3-1 and 3-2 of the Technical Specifications include an additional allowance of 30 psi for pressure measurement errors and 5°F for temperature measurement errors.
A proposed change to Technical Specification 3.1.8 that changed the maximum allowable PORV setpoints and addressed the consideration of_allowable setpoint tolerances was submitted September 22, 1989 (Tac No. 72889).
NRC approval of that proposed change will obviate this Letter of Interpretation, thus, this letter of interpretation shall be terminated at that time.
Meanwhile, Consumers Power Company will not consider it a reportable event if the PORV setpoints are found to deviate from the specified pressure (310 psia or 575 psia) or temperature* (300°F or 430°F) setpoints as long as the deviations are with in the allowable instrument inaccuracy ranges (+/-22 psia and +/-4.5°F).
rl=:91--1::::*1~C1!*i-c**-:* *=*o:::i *L 1--1---"--~
- ""1'.
- PDR ADOCK Ct50<J0255,
/\\oo f
- p "PDC
~
OC1189-0011-NL02 A CMS ENERGY COMPANY
- _r J
e **
-~
Nµelear Regulatory Commission Palisages Nuclear Plant TS 3.1.8 - Ltr of Interpretation November 14, 1989 This letter supersedes Consumers Power Company letter dated July 12, 1989.
The earlier letter of interpretation for technical sp~cification addressed only the allowable variation of the pressure setpoint.
Kenneth W Berry Director, Nuclear Licensing CC Administrator, Region III, USNRC NRC Resident Inspector ~ Palisades Reference
- 1.
Engineering Analysis E-PAL-89-015-01, LTOP Setpoint Margins.
OC1189-0011-NL02 2